XP Power AEL15US48L6 Ac-dc power supply Datasheet

AEL15-80-L6 Series
AC-DC Power Supplies
15-80 Watts
• Energy Efficiency Level VI
• Limited Power Source Approval
• China Compulsory Certification (CCC) Qualified
• +60 °C Operating Temperature
• Compact Dimensions
• 3 Year Warranty
Dimensions:
AEL15:
AEL20:
AEL40:
AEL60:
AEL80:
Models & Ratings
Output Power
12 W
15 W
15 W
20 W
25 W
40 W
57 W
63 W
80 W
Output Voltage(3)
5.0 VDC
12.0 VDC
24.0 VDC
48.0 VDC
5.0 VDC
12.0 VDC
24.0 VDC
48.0 VDC
5.0 VDC
12.0 VDC
24.0 VDC
48.0 VDC
12.0 VDC
24.0 VDC
48.0 VDC
12.0 VDC
24.0 VDC
48.0 VDC
Output Current
2.40 A
1.25 A
0.62 A
0.31 A
3.00 A
1.67 A
0.83 A
0.42 A
5.00 A
3.33 A
1.67 A
0.83 A
4.75 A
2.63 A
1.31 A
6.66 A
3.33 A
1.66 A
Total Regulation(2)
7%
5%
5%
3%
5%
4%
3%
3%
7%
5%
3%
3%
5%
5%
3%
5%
5%
5%
3.58
3.90
4.65
4.65
5.75
x
x
x
x
x
1.50
1.65
2.05
2.05
1.69
Efficiency(4)
82%
85%
84%
86%
79%
86%
87%
88%
79%
87%
88%
89%
87%
88%
90%
85%
87%
88%
x
x
x
x
x
1.42”
1.22”
1.36”
1.36”
2.99”
(91.0 x 38.0 x 36.0 mm)
(99.0 x 42.0 x 31.0 mm)
(118.0 x 52.0 x 34.5 mm)
(118.0 x 52.0 x 34.5 mm)
(146.0 x 76.0 x 43.0 mm)
Model Number(1,6)
AEL15US05L6
AEL15US12L6
AEL15US24L6
AEL15US48L6
AEL20US05-L6
AEL20US12-L6
AEL20US24-L6
AEL20US48-L6
AEL40US05-L6
AEL40US12-L6
AEL40US24-L6
AEL40US48-L6
AEL60US12-L6
AEL60US24-L6
AEL60US48-L6
AEL80US12-L6
AEL80US24-L6
AEL80US48-L6
Notes
1. Standard input connector is IEC320-C14 Inlet. For optional IEC320-C6 Inlet,
add suffix “C6” to model number e.g. AEL15US12L6C6.
2. Total regulation includes line regulation and load regulation.
3. Other output voltages available, contact sales for details.
4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
1
Minimum
90
47
Typical
Maximum
264
63
0.4
0.9
1.6
1.1
15/30
50/100
35/70
45/92
Units
VAC
Hz
Notes & Conditions
AEL15/20, Measured at 115/230 VAC
AEL40, Measured at 115/230 VAC
A
AEL60, Measured at 115/230 VAC
AEL80, Measured at 115/230 VAC
AEL15/20, Measured at 115/230 VAC, cold start at 25 °C
AEL40, Measured at 115/230 VAC, cold start at 25 °C
A
AEL60, Measured at 115/230 VAC, cold start at 25 °C
AEL80, Measured at 115/230 VAC, cold start at 25 °C
0.75
mA
Measured at 240 VAC
EN61000-3-2 Class A
0.1
W
For AEL15, 20 & 40, 0.21 for AEL60 & 80
Internal fuse in line, AEL15020: T1 A, 250 V, AEL40: T2 A, 250 V, AEL60/80: T3.15 A, 250 V
www.xppower.com
AEL15-80-L6 Series
AC-DC Power Supplies
Output
Characteristic
Output Voltage
Minimum Load
Hold Up Time
Min.
5
Typ.
Max.
48
5
10
16
Units
ms
0.5
2.0
s
Transient Response
2
%
Ripple and Noise
1
% pk-pk
132
150
%
%
Start Up Delay
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature Coefficient
112
110
Trip and restart (hiccup)
0.04
Notes & Conditions
See Models and Ratings table
No minimum load required
AEL15 at full load 110 VAC
AEL20/40 at full load 110 VAC
AEL60/80 at full load 110 VAC
AEL20/40 at full load, 100 VAC
AEL15/60/80 at full load, 100 VAC
Maximum deviation, recovering to less than 1% within
500 µs for 50% step load
Measured with 20 MHz bandwidth and 10 µF electrolytic
capacitor in parallel with a 0.1 µF ceramic capacitor
AEL40/60/80 models only
AEL20/40/60/80 models only
%/°C
Environmental
Characteristic
Operating Temperature
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Minimum
-20
Convection cooled
5
-40
Typical
Maximum
+60
Units
°C
Notes & Conditions
Derate from 100% load at 40 °C to 50% load at +60 °C
95
+85
2000
%RH
°C
m
Non-condensing
Maximum
Units
Notes & Conditions
10 g, 10 ms on 3 axes
General
Characteristic
Minimum
Typical
Efficiency
Isolation: Input to Output
Input to Ground
Output to Ground
Switching Frequency
Mean Time Between Failure
Weight
%
3000
See Models and Ratings table
VAC
1500
VAC*
500
VDC*
63 KHz
kHz
>100
kHrs
0.36 (165)
MIL-HDBK-217F at 25 °C GB
AEL15
0.37 (170)
0.64 (275)
*Not C8 version
AEL20
lb (g)
AEL40
0.79 (340)
AEL60
1.5 (700)
AEL80
www.xppower.com
2
AEL15-80-L6 Series
AC-DC Power Supplies
EMC: Emissions
Phenomenon
Emissions
Harmonic Current
Voltage Flicker
Standard
EN55022
EN61000-3-2
EN61000-3-3
Test Level
Level B
Class A
Notes & Conditions
Conducted & Radiated
EMC: Immunity
Phenomenon
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Dips and Interruptions
EN61000-4-11
Test Level
2
3 V/m
2
Installation Class 3
2
1 A/m
Dip: 30% 10 ms
Dip: 60% 100 ms
Int: 100% 5000 ms
Criteria
A
A
A
A
A
A
A
A/B
B
Notes & Conditions
At 230 VAC/115 VAC
Safety Approvals
Safety Agency
EN
UL
CCC
Safety Standard
EN60950-1
cUL60950-1
Notes & Conditions
Approved as limited power source (LPS), AEL15-60 only
China Compulsory Certification Qualified
www.xppower.com
3
AEL15-80-L6 Series
AC-DC Power Supplies
AEL15-L6
1.42 (36.0)
1.50 (38.0)
3.58 (91.0)
AC INPUT
IEC-320-C6 INLET
AC INPUT
IEC-320-C14 INLET
Notes
1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
2. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter
barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0).
3. Output cable length is 48” (1220mm) approx.
4. Weight: 0.36 lbs (165 g)
5. For European mains lead order part: EU-MAINS-IEC or EU-MAINS-5 for C6
version.
6. For UK mains lead order part: UK-MAINS-IEC or UK-MAINS-5 for C6 version.
7. For US mains lead order part: US-MAINS-IEC or US-MAINS-5 for C6 version.
8. Mains lead length is 78“ (2000 mm) approx
AEL20-L6
0.02 (0.5)
AC INPUT
IEC-320-C8 INLET
(Optional C2 Version)
0.04 (1.0)
1.22 (31.0)
1.65 (42.0)
3.90 (99.0)
AC INPUT
IEC-320-C6 INLET
Notes
1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
2. Output connector: 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter
barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0).
3. Output cable length is 48” (1220mm) approx.
4. Weight: 0.37 lbs (170 g)
5. For European mains lead order part: EU-MAINS-C5 for AEL20, EU-MAINS-8
for AEL20 Class II.
6. For UK mains lead order part: UK-MAINS-5 for AEL20, UK-MAINS-8 for AEL20
Class II.
7. For US mains lead order part: US-MAINS-5 for AEL20, US-MAINS-8 for AEL20
Class II.
8. Mains lead length is 78“ (2000 mm) approx
www.xppower.com
AEL15-80-L6 Series
AC-DC Power Supplies
AEL40-L6
0.04 (1.0)
0.04 (1.0)
1.36 (34.5)
4.65 (118.0)
2.05 (52.0)
0.02 (0.5)
AC INPUT
IEC-320-C14 INLET
Notes
1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
2. Output connector: 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter
barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0).
3. Output cable length is 48” (1220mm) approx.
4. Weight: 0.64 lbs (275 g).
5. For European mains lead order part: EU-MAINS-IEC.
6. For UK mains lead order part: UK-MAINS-IEC.
7. For US mains lead order part: US-MAINS-IEC.
8. Mains lead length is 78“ (2000 mm) approx
AEL60-L6
0.04 (1.0)
0.04 (1.0)
1.36 (34.5)
4.65 (118.0)
2.05 (52.0)
0.02 (0.5)
AC INPUT
IEC-320-C14 INLET
Notes
1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
2. Output connector: 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter
barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0).
3. Output cable length is 48” (1220mm) approx.
4. Weight: 0.79 lbs (340 g).
5. For European mains lead order part: EU-MAINS-IEC.
6. For UK mains lead order part: UK-MAINS-IEC.
7. For US mains lead order part: US-MAINS-IEC.
8. Mains lead length is 78“ (2000 mm) approx
www.xppower.com
5
AEL15-80-L6 Series
AC-DC Power Supplies
AEL80-L6
0.04 (1.0)
0.04 (1.0)
1.69 (43.0)
5.75 (146.0)
3
AC INPUT
IEC-320-C14 INLET
1.41 (36.0)
2.99 (76.0)
0.02 (0.5)
DC Output 5 Pin Plug
5
2
1
4
Notes
1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
2. Output connector: 5 pin 180° DIN
3. Output cable length: 48” (1220mm) approx.
4. Weight: 1.5 lbs (700 g)
5. For European mains lead order part: EU-MAINS-IEC.
6. For UK mains lead order part: UK-MAINS-IEC.
7. For US mains lead order part: US-MAINS-IEC.
8. Mains lead length is 78“ (2000 mm) approx
www.xppower.com
13-Oct-15
Similar pages