Product Data Sheet HU362 Safety Switch , 60A, 600V, Non-Fusible, Heavy Duty, 3-Pole List Price $325.00 USD Availability Stock Item: This item is normally stocked in our distribution facility. Technical Characteristics Depth 6.38 Inches Height 17.50 Inches Width 9.00 Inches Action Single Throw Ampere Rating 60A Approvals UL Listed Catalog Reference Number 3100CT9801 Electrical Interlock None Enclosure Material Steel Enclosure Rating NEMA 1 Enclosure Type General Purpose (Indoor) Factory Installed Neutral No Disconnect Type Non-Fusible Terminal Type Lugs Mounting Type Surface Wire Size #12 to #2 AWG(Al) or #14 to #2 AWG(Cu) Type of Duty Heavy Duty Short Circuit Current Rating 200kA(max) Number of Poles 3-Pole Maximum Voltage Rating 600V Shipping and Ordering Category 00008 - Safety Switch, Heavy Duty, 2 & 3 Pole, 30-200 Amp, Indoor Discount Schedule DE1 Article Number 785901505808 Package Quantity 1 Weight 14.8 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Returnability Y As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 06/17/2009 08:05:13 © 2009 Schneider Electric. All rights reserved. 1 Heavy Duty Safety Switches www.schneider-electric.us Table 3.10: System 600 Volt—Single Throw Non-Fusible Rating (A) NEMA 1 Indoor Cat. No. $ Price NEMA 3R Rainproof (Bolt-on Hubs, page 3-11) Cat. No. $ Price NEMA 4, 4X, 5 a 304 Stainless Steel (for 316 stainless, see page 3-7) Dust tight, Watertight Corrosion Resistant (Watertight Hubs, page 3-11) Cat. No. $ Price NEMA 12K With Knockouts (Watertight Hubs, page 3-11) Cat. No. $ Price NEMA 12, 3Rb Without Knockouts (Watertight Hubs, page 3-11) Cat. No. $ Price 3 SAFETY SWITCHES 2-Wire (2 Blades)—600 Vac, 600 Vdc 30 60 Use three-wire devices for two-wire applications. 100 200 400 HU265 2750.00 HU265R 3764.00 HU265DS 12812.00 — — HU265AWK 600 HU266 4896.00 HU266R 7533.00 HU266DS 18455.00 — — HU266AWK 800 HU267 7467.00 HU267Re 12884.00 — — — — HU267AWK 1200 HU268 10226.00 HU268Re 17393.00 — — — — HU268AWK 3-Wire (3 Blades)—600 Vac, 600 Vdc 30 HU361 279.00 HU361RB 488.00 HU361DS 2520.00 HU361A 689.00 HU361AWK 30 HU361EIf 638.00 HU361RBEIf 846.00 HU361DSEIf 2480.00 HU361AEIf 1047.00 HU361AWKEIf 30 HU3612g 369.00 HU3612RBg 638.00 — — HU3612Ag 710.00 HU3612AWKg 60 HU362 488.00 HU362RB 876.00 HU362DS 2520.00 HU362A 875.00 HU362AWK 60 — — — — HU362DSEIf 2972.00 — — — 100 HU363 783.00 HU363RB 1226.00 HU363DS 5102.00 HU363A 1265.00 HU363AWK 200 HU364 1209.00 HU364RB 1485.00 HU364DS 6960.00 HU364A 1697.00 HU364AWK 400 HU365 2804.00 HU365R 3840.00 HU365DS 14294.00 — — HU365AWK 600 HU366 4992.00 HU366R 7683.00 HU366DS 19062.00 — — HU366AWK 800 HU367 9978.00 HU367Re 13050.00 — — — — HU367AWK 1200 HU368 13421.00 HU368Re 17867.00 — — — — HU368AWK 4-Wire (4 Blades)—600 Vac, 600 Vdc k 30 HU461h 827.00 — — HU461DS 2586.00 — — HU461AWKi 60 HU462h 914.00 — — HU462DS 3027.00 — — HU462AWK 100 HU463h 1647.00 — — HU463DS 7401.00 — — HU463AWK 200 HU464h 2399.00 — — HU464DS 11244.00 — — HU464AWK 400 HU465 5201.00 — — — — — — HU465AWK 600 HU466 9072.00 — — — — — — — 6-Wire (6 Blades)—600 Vack 30 — — — — HU661DS 11903.00 — — HU661AWKl 13254.00 — — HU662AWKl 60 — — — — HU662DS 100 — — — — HU663DS 20643.00 — — HU663AWKl 200 — — — — HU664DS 28316.00 — — HU664AWKl a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c Refer to page 7-32 for additional motor application data. d For switching dc, use two switching poles. e Suitable for NEMA 5 applications with drain screw installed. f Switches with EI suffix are stocked with factory-installed electrical interlocks with one normally-open and one normally-closed contact. g Use 60 A enclosure accessories, including electrical interlocks. h No knockouts are provided. i Check series number on switch for correct accessory. See page 3-15. j HU461AWK (Series E1) is rated 5 hp@250 Vdc, 10 hp@600 Vdc. k Not suitable for use as service equipment. l One enclosure for NEMA 1, 3, 3R or 12 applications. UL Listed. 3212.00 5408.00 12957.00 17522.00 647.00 1007.00 666.00 833.00 — 1194.00 1604.00 4023.00 6711.00 13097.00 17940.00 Horsepower Ratings (Max.) c Volts ac 240 480 600 dcd 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 250 600 — — — — — — 50 50 — — — — — — 50 50 — — — — — — — — 915.00 1008.00 1791.00 2832.00 5672.00 — 5 5 5 10 10 20 15 — — 50 50 2Ø 10 20 30 50 — — 3357.00 3884.00 4793.00 10538.00 — — — — — — — — — — — — — — — — — — 50 — — — — — — — — — — — — — 50 50 — 50 — — — — 50 50 50 50 10 7-1/2 20 10 30 5 15 10 7-1/2 20 10 30 5 15 10 7-1/2 20 10 30 5 15 20 25 50 30 60 10 30 20 25 50 30 60 10 30 40 40 75 40 100 20 50 60 50 125 50 150 40 50 125 — 250 — 350 50 50 200 — 400 — 500 50 50 250 50 500 50 500 50 50 250 50 500 50 500 50 50 3Ø 2Ø 3Ø 2Ø 3Ø 10 20 20 25 30 10j 15j 20 40 50 50 60 10 30 40 50 75 50 75 20 30 60 50 125 50 150 40 50 125 — 250 — 350 50 50 200 — 400 — 500 50 50 3Ø 3Ø 3Ø 10 — 20 — 30 — — 20 — 50 — 60 — — 40 — 75 — 75 — — 60 — 125 — 150 — — UL Listed Maximum Short Circuit Current Ratings—AC only Non-Fusible Safety Switches NOTE: Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. Table 3.11: Fusible Safety Switches For the short circuit current rating, refer to the table below. Heavy Duty Safety Switch Type m 3-6 UL Listed UL Listed Short Circuit Fuse Class Current Ratings H, K 10 kA Fusible R, J, L 200 kAm On 600 V, 200 A switches, 100,000 A max. on corner grounded delta when protected by Class J or R fuses. DE1 Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used in conjunction with an non-fusible safety switch when there is up to 10 kA short circuit current available (see table below). Above 10 kA—When applied on systems with greater than 10 kA short circuit current available, the UL Listed short circuit current rating for Square D non-fusible switches is based upon the switch being used in conjunction with fuses or Square D circuit breakers or Mag-Gard motor circuit protectors. Table 3.12: Non-Fusible Safety Switches Heavy Duty Switch Rating Safety Switch Type (A) n Fuse or Circuit Breaker Typeo 3-Phase 480 Vac 600 Vac Any brand circuit breaker Up to 10 kA All H, K R,T,J.L 200 kA 200 kA 200 kA 30–100 Hp 65 kA 35 kA 25 kA 30–100 FA 14 kA 14 kA 14 kA Non-Fusible 30–100 FH 18 kA 18 kA 18 kA Switches 200 H, J p 65 kA 35 kA 25 kA 200 KA 400 LA 22 kA 22 kA 22 kA 600 MA 200 KH 400 LH 25 kA 25 kA 25 kA 600 MH n Applies to NEMA 1, 3R, 4X stainless, 12 switches. o Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. p All H and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Ratings. Discount Schedule 240 Vac © 2009 Schneider Electric All Rights Reserved