Online data sheet M20S-081A3A120, M20E-081A3A120 M2000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES M20S-081A3A120, M20E-081A3A120 | M2000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES A B C D E F Ordering information System part Type Part no. Sender M20S-081A3A120 1016440 Receiver M20E-081A3A120 1016441 1.) Concerns installation as a replacement part for previous type 2 device in machine: Regarding Machinery Directive 2006/42/EC, Article 1, Paragraph (2a) this type 2 device may only be used as a replacement part for identical PL d / SIL2 devices within the EU if the machine was put into circulation before 2015-05-10. Keep this note with your machine documentation. If the machine is sold on, this note and the information it contains must be passed on to every subsequent buyer. 2.) Concerns installation on new machines: Due to the amendment to the EN/IEC 61496-1 standard, this type 2 device may only be installed on new machines up to PL c / SIL1 as of 2015-05-10. Other models and accessories www.sick.com/M2000_Standard Detailed technical data Features H I J K L M N O P Q R S T Scanning range 0 m ... 25 m, configurable Low scanning range 0 m ... 6 m Great scanning range 2 m ... 25 m Number of beams 8 Beam separation or resolution 170 mm Response time 8 ms Synchronization Optical synchronisation Safety-related parameters Type Type 2 (IEC 61496) Safety integrity level SIL1 (IEC 61508) SILCL1 (EN 62061) Category Category 2 (EN ISO 13849) Test rate (internal test) 13 /s (EN ISO 13849) 1) Maximum demand rate ≤ 8 min⁻¹ (EN ISO 13849) 2) Performance level PL c (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 6.6 x 10-9 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state. 1) 2) Internal test. The test rate may not be exceeded if an external test is performed. Between two requirements on a safety-related response of the device, at least 100 internal or external tests must be carried out. Functions Functions Delivery status Beam coding ✔ Uncoded Configurable scanning range ✔ 2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-06-14 08:06:28 Subject to change without notice M20S-081A3A120, M20E-081A3A120 | M2000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES Interfaces System connection Connection type Hirschmann plug M26, 7-pin Permitted cable length ≤ 60 m 1) Permitted cross-section ≥ 1 mm² Configuration method Hard wired Display elements LEDs 7-segment display Fieldbus, industrial network Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 2) 1) 2) Depending on load, power supply and wire cross-section. The technical specifications must be observed. For additional information on Flexi Soft -> www.sick.com/Flexi_Soft. Electrical data Sender Protection class III (EN 50178) Supply voltage VS 24 V DC (19.2 V DC ... 28.8 V DC) 1) Power consumption ≤ 3.7 W (DC) Receiver ≤ 5 W (DC) Safety outputs (OSSD) Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 2) Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS) Switching voltage LOW ≤ 1 V DC Switching current ≤ 500 mA 1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK. 2) Applies to the voltage range between –30 V and +30 V. Mechanical data Housing cross-section 48 mm x 40 mm Ambient data Enclosure rating IP65 (EN 60529) Ambient operating temperature 0 °C ... +55 °C Storage temperature –25 °C ... +70 °C Air humidity 15 % ... 95 %, Non-condensing Vibration resistance 5 g, 10 Hz ... 55 Hz (IEC 60068-2-6) Shock resistance 10 g, 16 ms (IEC 60068-2-29) Other information Wave length 2017-06-14 08:06:28 | Online data sheet Subject to change without notice 950 nm OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3 M20S-081A3A120, M20E-081A3A120 | M2000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES Dimensional drawing (Dimensions in mm (inch)) 1.7 8 (0.31) (1.69) 2 Ø 8.4 48 (1.89) 3 44.4 4 (0.33) (1.75) 75 (2.95) 68 (2.68) 1 11.9 20 (0.47) (0.79) 48 5 (1.89) 40 14 L6 L1 A1 (0.41) S1 3.5 (0.14) 1 10.5 (0.09) 2.2 L5 (1.67) (0.04) 6 (1.57) (0.55) (0.24) 42.3 22.4 25.6 (0.88) 35 22.5 (1.38) 48 (1.89) 76.3 (3.00) (1.01) 42.6 (0.89) H I J K L M N O P Q R S T (0.07) 42.9 L4 L2 L3 A B C D E F (1.68) 6 4 Number of beams Beam separation Resolution L1 L2 L3 L4 L5 L6 2 500 (19.69) - 630 (24.80) 697 (27.44) 588 (23.15) 718 (28.27) 655 (25.79) 675 (26.57) 3 400 (15.75) - 931 (36.65) 998 (39.29) 888 (34.96) 1,019 (40.12) 956 (37.64) 976 (38.43) 4 300 (11.81) - 989 (38.94) 1,119 (44.06) 1,056 (41.57) 1,076 (42.36) 6 - 170 (6.69) 874 (34.41) 1,004 (39.53) 7 - 170 (6.69) 8 - 116 (4.57) 8 - 170 (6.69) 1,231 (48.46) 1,298 (51.10) 1,189 (46.81) 1,319 (51.93) 1,256 (49.45) 1,275 (50.20) 9 - 170 (6.69) 1,388 (54.65) 1,455 (57.28) 1,346 (52.99) 1,476 (58.11) 1,413 (55.63) 1,433 (56.42) OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 1,031 (40.59) 1,098 (43.23) 916 (36.06) 983 (38.70) 941 (37.05) 960 (37.80) 1,073 (42.24) 1,140 (44.88) 1,031 (40.59) 1,161 (45.71) 1,098 (43.23) 1,118 (44.02) 851 (33.50) 919 (36.18) 809 (31.85) 939 (36.97) 877 (34.53) 896 (35.28) Online data sheet | 2017-06-14 08:06:28 Subject to change without notice M20S-081A3A120, M20E-081A3A120 | M2000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES Connection diagram +24 V DC 1) x s r +24 V +24 V GND GND Test OSSD1 4 HRANGE OSSD2 5 Sel1 Sel1 Sel2 Sel2 1 2 3 6 y k1 k2 x 1 y z 2 k1 3 4 k2 5 z 6 Shield Shield S1 M2000 S33 S11 S12 S31 A1 k1 13 23 31 UE48-2OS2D2 S34 S35 S21 S22 A2 14 24 32 k2 2) K1 K2 0V 3) PELV E119932/01/2017-06-12 Task Connection of an M2000 Standard multi-beam photoelectric safety switch to UE48-2OS. Operating mode: with restart interlock and external device monitoring. Function When the light path is clear, the OSSD1 and OSSD2 outputs are live. The system is ready to switch on if K1 and K2 are de-energized. By pressing S1 (button is pressed and released), the UE48-2OS is energized and its 13 - 14 and 23 - 24 contacts activate K1 and K2. On interruption of one of the light beams, the UE48-2OS is de-energized by the OSSD1 and OSSD2 outputs and K1 and K2 are deactivated. Fault analysis OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The incorrect functioning of one of the K1 or K2 contactors will be detected and does not result in the loss of the shutdown function. Jamming of the S1 button will prevent the UE48-2OS from enabling. Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, the integration must be dual-channel (x/y paths). Single-channel integration in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. 2) The external device monitoring is only static. 3) PELV as required in EN 60204-1 / 6.4 The related operating instructions for the integrated devices must be observed. 2017-06-14 08:06:28 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5 M20S-081A3A120, M20E-081A3A120 | M2000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES A B C D E F Recommended accessories Other models and accessories www.sick.com/M2000_Standard Brief description Type Part no. BEF-3WNGBAST4 7021352 4 pieces, Mounting kit 6, side bracket, rotatable, Zinc diecast BEF-1SHABAZN4 2019506 4 pieces, Omega bracket, rotatable, fixable with only one screw, for mounting on the swivel mount BEF-2SMMEAAL4 2044847 4 pieces, Mounting kit 2, rotatable, swivel mount, Polyamide PA6 BEF-2SMMEAKU4 2019659 AR60 1015741 AR60 adapter, 48x40 4032461 AR60 adapter, 48x40, PU3H 4056731 Mounting brackets and plates 4 pieces, Mounting kit 1, mounting bracket, rigid, L-shaped, including fixing screws and washers Terminal and alignment brackets Alignment aids H I J K L M N O P Q R S T Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into the beam! Adapter AR60 for housing cross-section 48 mm x 40 mm Adapter AR60 for housing cross-section 48 mm x 40 mm in PU3H device column 6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-06-14 08:06:28 Subject to change without notice Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG | Waldkirch | Germany | www.sick.com