TDK B41858D5227M Aluminum electrolytic capacitor Datasheet

Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type:
B41858
Date:
October 2015
© EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Single-ended capacitors
B41858
Low impedance 105 °C
Long-life grade capacitors
Applications
Automotive electronics
For use in output circuits of switch-mode power supplies of
compact design
For professional industrial electronics, telecommunications
and data processing equipment
Features
Low impedance at high frequency
High reliability
Low ESR
High ripple current capability
RoHS-compatible
Construction
Radial leads
Charge-discharge proof, polar
Aluminum case with insulating sleeve
Minus pole marking on the insulating sleeve
Case with safety vent
Delivery mode
Terminal configurations and packing:
Bulk
Taped, Ammo pack
Cut
Kinked
PAPR (protection against polarity reversal):
crimped leads, J leads, bent leads
Refer to chapter "Single-ended capacitors Taping, packing
and lead configurations" for further details.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 33
B41858
Low impedance 105 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
10 ... 100 V DC
1.15 VR
Rated capacitance CR
Capacitance tolerance
22 ... 10000 µF
±20% M
Dissipation factor tan δ
(20 °C, 120 Hz)
For capacitance higher than 1000 µF add 0.02 for every increase of
1000 µF.
VR (V DC)
10
16
25
35
50
63
100
tan δ (max.)
0.19
Diameter (mm)
8 ... 12.5
16
18
ESL (nH)
20
26
34
0.16
0.14
0.12
0.10
0.10
0.08
Leakage current Ileak
(20 °C, 5 min)
Self-inductance ESL
Useful life1)
105 °C; VR; IAC,R
Requirements
Voltage endurance test
105 °C; VR
Post test requirements
Vibration resistance test
> 3000 h for d = 8 mm
> 5000 h for d ≥ 10 mm
∆C/C ≤ 40% of initial value
tan δ ≤ 3 times initial specified limit
Ileak
≤ initial specified limit
3000 h for d = 8 mm
5000 h for d ≥ 10 mm
∆C/C ≤ 30% of initial value
tan δ ≤ 2 times initial specified limit
Ileak
≤ initial specified limit
To IEC 60068-2-6, test Fc:
Frequency range 10 Hz ... 2 kHz, displacement amplitude max.
1.5 mm, acceleration max. 20 g, duration 3 × 2 h.
Capacitor rigidly clamped by the aluminum case.
IEC climatic category
To IEC 60068-1:
55/105/56 (55 °C/+105 °C/56 days damp heat test)
Sectional specification
IEC 60384-4, AEC Q200
1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 33
B41858
Low impedance 105 °C
Dimensional drawings
With stand-off rubber seal
Diameters (mm): 10, 12.5, 16, 18
With flat rubber seal
Diameter (mm): 8
Dimensions and weights
Dimensions (mm)
d +0.5
8
10
10
10
12.5
12.5
12.5
12.5
16
16
16
16
18
18
18
18
18
l
11.5 +1.5
12.5 +1.0
16 +1.0
20 +2.0
20 +2.0
25 +2.0
30 +2.0
40 +2.0
20 +2.0
25 +2.0
31.5 +2.0
35.5 +2.0
20 +2.0
25 +2.0
31.5 +2.0
35 +2.0
40 +2.0
Please read Cautions and warnings and
Important notes at the end of this document.
a ±0.5
3.5
5.0
5.0
5.0
5.0
5.0
5.0
5.0
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
Page 4 of 33
b
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
Approx. weight
g
1.0
1.6
1.9
2.6
3.6
4.5
5.3
7.4
5.5
7.5
7.8
9.2
8.0
9.0
11.0
13.0
16.0
B41858
Low impedance 105 °C
Overview of available types
VR (V DC)
10
16
25
35
Case dimensions d × l (mm)
CR (µF)
100
8
× 11.5
120
8
× 11.5
8
× 11.5
180
8
× 11.5
10
× 12.5
220
8
× 11.5
10
× 12.5
150
270
8
× 11.5
10
× 12.5
8
× 11.5
10
× 12.5
10
× 16
330
8
× 11.5
390
8
× 11.5
470
8
× 11.5
10
× 12.5
10
× 16
10
× 20
560
10
× 12.5
10
× 16
10
× 16
10
× 20
680
10
× 12.5
10
× 16
10
× 20
12.5 × 20
× 20
820
10
× 16
10
× 20
10
1000
10
× 16
10
× 20
12.5 × 20
1200
10
× 16
10
× 20
1500
10
× 20
12.5 × 20
12.5 × 25
1800
10
× 20
12.5 × 25
16
× 20
16
18
× 25
× 20
2200
12.5 × 20
12.5 × 25
12.5 × 40
16 × 25
18 × 20
18
× 25
2700
12.5 × 25
16
× 20
16
18
× 31.5
× 20
18
× 31.5
3300
12.5 × 25
16 × 20
12.5 × 40
16 × 25
18
× 25
16
18
× 35.5
× 31.5
3900
12.5 × 40
16 × 20
16
18
× 31.5
× 20
16
18
× 35.5
× 31.5
18
× 35
4700
18
× 20
18
× 25
18
× 31.5
18
× 40
5600
12.5 × 40
18
× 35
6800
16
× 31.5
18
× 31.5
18
× 40
8200
18
× 31.5
18
× 35
10000
18
× 35
18
× 40
Please read Cautions and warnings and
Important notes at the end of this document.
12.5 × 25
16 × 20
16
Page 5 of 33
× 20
12.5 × 40
16 × 25
B41858
Low impedance 105 °C
VR (V DC)
50
63
100
Case dimensions d × l (mm)
CR (µF)
× 11.5
22
8
33
10
× 16
47
10
× 20
68
8
× 11.5
100
8
× 11.5
10
× 12.5
12.5 × 20
120
10
× 12.5
10
× 16
12.5 × 25
150
10
× 12.5
10
× 16
180
10
× 16
10
× 20
12.5 × 30
16 × 20
220
10
× 16
10
× 20
16
270
330
10
× 20
390
12.5 × 40
18 × 20
12.5 × 20
16
18
× 31.5
× 25
12.5 × 25
18
× 31.5
12.5 × 25
16 × 20
18
× 35
18
× 35
18
× 40
470
12.5 × 20
560
12.5 × 25
680
12.5 × 30
12.5 × 40
16 × 25
18 × 20
820
12.5 × 40
16 × 20
16
18
× 31.5
× 25
1000
16
18
× 31.5
× 20
16
× 31.5
1200
18
× 20
18
× 31.5
1500
18
× 25
18
× 35
1800
16
18
× 35.5
× 31.5
18
× 40
2200
18
× 35
2700
18
× 40
Other voltage and capacitance ratings are available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
× 25
12.5 × 20
Page 6 of 33
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
VR = 10 V DC
330
8 × 11.5
390
8 × 11.5
470
8 × 11.5
560
10 × 12.5
680
10 × 12.5
820
10 × 16
1000
10 × 16
1200
10 × 16
1500
10 × 20
1800
10 × 20
2200
12.5 × 20
2700
12.5 × 25
3300
12.5 × 25
3300
16 × 20
3900
12.5 × 40
3900
16 × 20
4700
18 × 20
5600
12.5 × 40
6800
16 × 31.5
8200
18 × 31.5
10000
18 × 35
2.195
2.195
2.195
1.035
1.035
0.946
0.946
0.944
0.584
0.584
0.496
0.327
0.327
0.307
0.240
0.307
0.271
0.243
0.192
0.165
0.160
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
Ordering code
(composition see
below)
0.274
0.274
0.274
0.129
0.129
0.118
0.118
0.118
0.073
0.073
0.062
0.041
0.041
0.038
0.030
0.038
0.034
0.030
0.024
0.021
0.020
0.246
0.246
0.246
0.113
0.113
0.105
0.105
0.105
0.062
0.062
0.060
0.034
0.034
0.033
0.025
0.033
0.031
0.025
0.022
0.020
0.018
436
436
436
746
746
846
846
846
1202
1202
1396
2028
2028
2146
2858
2146
2381
2858
3122
3539
3864
B41858C3337M***
B41858C3397M***
B41858C3477M***
B41858C3567M***
B41858C3687M***
B41858C3827M***
B41858C3108M***
B41858C3128M***
B41858C3158M***
B41858C3188M***
B41858C3228M***
B41858C3278M***
B41858C3338M***
B41858D3338M***
B41858C3398M***
B41858D3398M***
B41858C3478M***
B41858C3568M***
B41858C3688M***
B41858C3828M***
B41858C3109M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm)
002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)
003 = for crimped leads, blister (for ∅ 16 ... 18 mm)
004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and
18 × 20 ... 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 33
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
VR = 16 V DC
270
8 × 11.5
330
8 × 11.5
470
10 × 12.5
560
10 × 16
680
10 × 16
820
10 × 20
1000
10 × 20
1200
10 × 20
1500
12.5 × 20
1800
12.5 × 25
2200
12.5 × 25
2700
16 × 20
3300
12.5 × 40
3300
16 × 25
3900
16 × 31.5
3900
18 × 20
4700
18 × 25
6800
18 × 31.5
8200
18 × 35
10000
18 × 40
2.192
2.192
1.035
0.944
0.946
0.584
0.584
0.584
0.496
0.327
0.327
0.307
0.243
0.251
0.192
0.271
0.217
0.165
0.160
0.125
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
Ordering code
(composition see
below)
0.274
0.274
0.129
0.118
0.118
0.073
0.073
0.073
0.062
0.041
0.041
0.038
0.030
0.031
0.024
0.034
0.027
0.021
0.020
0.016
0.246
0.246
0.113
0.105
0.105
0.062
0.062
0.062
0.060
0.034
0.034
0.033
0.025
0.029
0.022
0.031
0.024
0.020
0.018
0.015
436
436
746
846
846
1202
1202
1202
1396
2028
2028
2146
2858
2483
3122
2381
2941
3539
3864
4467
B41858D4277M***
B41858D4337M***
B41858C4477M***
B41858C4567M***
B41858C4687M***
B41858C4827M***
B41858C4108M***
B41858C4128M***
B41858C4158M***
B41858C4188M***
B41858C4228M***
B41858C4278M***
B41858D4338M***
B41858C4338M***
B41858D4398M***
B41858C4398M***
B41858C4478M***
B41858C4688M***
B41858C4828M***
B41858C4109M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm)
002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)
003 = for crimped leads, blister (for ∅ 16 ... 18 mm)
004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and
18 × 20 ... 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 33
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
VR = 25 V DC
180
8 × 11.5
220
8 × 11.5
270
10 × 12.5
330
10 × 12.5
470
10 × 16
560
10 × 16
680
10 × 20
820
10 × 20
1000
12.5 × 20
1500
12.5 × 25
1800
16 × 20
2200
12.5 × 40
2200
16 × 25
2200
18 × 20
2700
16 × 31.5
2700
18 × 20
3300
18 × 25
3900
16 × 35.5
3900
18 × 31.5
4700
18 × 31.5
5600
18 × 35
6800
18 × 40
2.192
2.192
1.032
1.035
0.946
0.944
0.584
0.584
0.496
0.327
0.307
0.243
0.251
0.248
0.192
0.271
0.217
0.168
0.165
0.165
0.160
0.128
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
Ordering code
(composition see
below)
0.274
0.274
0.129
0.129
0.118
0.118
0.073
0.073
0.062
0.041
0.038
0.030
0.031
0.031
0.024
0.034
0.027
0.021
0.021
0.021
0.020
0.016
0.246
0.246
0.113
0.113
0.105
0.105
0.062
0.062
0.060
0.034
0.033
0.025
0.029
0.031
0.022
0.031
0.024
0.019
0.020
0.020
0.018
0.015
436
436
746
746
846
846
1202
1202
1396
2028
2146
2858
2483
2381
3122
2381
2941
3408
3539
3539
3864
4467
B41858D5187M***
B41858D5227M***
B41858C5277M***
B41858C5337M***
B41858C5477M***
B41858C5567M***
B41858C5687M***
B41858C5827M***
B41858C5108M***
B41858C5158M***
B41858C5188M***
B41858D5228M***
B41858C5228M***
B41858E5228M***
B41858D5278M***
B41858C5278M***
B41858C5338M***
B41858D5398M***
B41858C5398M***
B41858D5478M***
B41858D5568M***
B41858C5688M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm)
002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)
003 = for crimped leads, blister (for ∅ 16 ... 18 mm)
004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and
18 × 20 ... 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 33
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
VR = 35 V DC
100
8 × 11.5
120
8 × 11.5
150
8 × 11.5
180
10 × 12.5
220
10 × 12.5
330
10 × 16
470
10 × 20
560
10 × 20
680
12.5 × 20
1000
12.5 × 25
1000
16 × 20
1200
16 × 20
1500
12.5 × 40
1500
16 × 25
1800
16 × 25
1800
18 × 20
2200
18 × 25
2700
18 × 31.5
3300
16 × 35.5
3300
18 × 31.5
3900
18 × 35
4700
18 × 40
2.192
2.192
2.192
1.035
1.035
0.946
0.584
0.584
0.496
0.327
0.304
0.307
0.243
0.251
0.248
0.271
0.217
0.165
0.168
0.165
0.160
0.125
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
Ordering code
(composition see
below)
0.274
0.274
0.274
0.129
0.129
0.118
0.073
0.073
0.062
0.041
0.038
0.038
0.030
0.031
0.031
0.034
0.027
0.021
0.021
0.021
0.020
0.016
0.246
0.246
0.246
0.113
0.113
0.105
0.062
0.062
0.060
0.034
0.033
0.033
0.025
0.029
0.029
0.031
0.024
0.020
0.019
0.020
0.018
0.015
436
436
436
746
746
846
1202
1202
1396
2028
2146
2146
2858
2483
2483
2381
2941
3539
3408
3539
3864
4467
B41858C7107M***
B41858D7127M***
B41858C7157M***
B41858C7187M***
B41858C7227M***
B41858C7337M***
B41858C7477M***
B41858C7567M***
B41858C7687M***
B41858C7108M***
B41858D7108M***
B41858C7128M***
B41858D7158M***
B41858C7158M***
B41858E7188M***
B41858C7188M***
B41858C7228M***
B41858C7278M***
B41858E7338M***
B41858D7338M***
B41858C7398M***
B41858C7478M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm)
002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)
003 = for crimped leads, blister (for ∅ 16 ... 18 mm)
004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and
18 × 20 ... 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 33
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
VR = 50 V DC
100
8 × 11.5
120
10 × 12.5
150
10 × 12.5
180
10 × 16
220
10 × 16
330
10 × 20
470
12.5 × 20
560
12.5 × 25
680
12.5 × 30
820
12.5 × 40
820
16 × 20
1000
16 × 31.5
1000
18 × 20
1200
18 × 20
1500
18 × 25
1800
16 × 35.5
1800
18 × 31.5
2200
18 × 35
2700
18 × 40
5.168
2.984
2.984
1.400
1.400
1.000
0.880
0.712
0.360
0.269
0.401
0.260
0.477
0.384
0.382
0.232
0.300
0.268
0.210
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
Ordering code
(composition see
below)
0.646
0.373
0.373
0.175
0.175
0.125
0.110
0.089
0.045
0.034
0.050
0.032
0.048
0.048
0.038
0.029
0.030
0.027
0.021
0.573
0.336
0.336
0.160
0.160
0.118
0.104
0.082
0.043
0.032
0.046
0.030
0.044
0.044
0.036
0.026
0.028
0.024
0.020
340
555
555
778
778
1030
1300
1490
2140
2799
1820
2653
1997
1997
2417
2896
2989
3320
3871
B41858C6107M***
B41858C6127M***
B41858C6157M***
B41858C6187M***
B41858C6227M***
B41858C6337M***
B41858C6477M***
B41858C6567M***
B41858C6687M***
B41858C6827M***
B41858D6827M***
B41858C6108M***
B41858D6108M***
B41858C6128M***
B41858C6158M***
B41858D6188M***
B41858C6188M***
B41858C6228M***
B41858C6278M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm)
002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)
003 = for crimped leads, blister (for ∅ 16 ... 18 mm)
004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and
18 × 20 ... 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 11 of 33
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
VR = 63 V DC
68
8 × 11.5
100
10 × 12.5
120
10 × 16
150
10 × 16
180
10 × 20
220
10 × 20
270
12.5 × 20
330
12.5 × 20
390
12.5 × 25
470
12.5 × 25
470
16 × 20
680
12.5 × 40
680
16 × 25
680
18 × 20
820
16 × 31.5
820
18 × 25
1000
16 × 31.5
1200
18 × 31.5
1500
18 × 35
1800
18 × 40
4.328
4.616
3.075
2.464
1.986
1.592
1.688
1.688
1.236
0.992
1.037
0.717
0.772
0.960
0.541
0.761
0.540
0.518
0.441
0.375
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
Ordering code
(composition see
below)
0.541
0.577
0.308
0.308
0.199
0.199
0.169
0.169
0.124
0.124
0.104
0.072
0.077
0.096
0.054
0.076
0.054
0.052
0.044
0.038
0.488
0.500
0.279
0.279
0.180
0.180
0.153
0.153
0.112
0.112
0.094
0.065
0.070
0.087
0.049
0.069
0.049
0.047
0.040
0.034
310
354
519
519
705
705
876
876
1118
1118
1272
1785
1600
1427
2092
1735
2092
2294
2592
2967
B41858C8686M***
B41858C8107M***
B41858C8127M***
B41858C8157M***
B41858C8187M***
B41858C8227M***
B41858C8277M***
B41858C8337M***
B41858C8397M***
B41858E8477M***
B41858C8477M***
B41858C8687M***
B41858D8687M***
B41858E8687M***
B41858C8827M***
B41858D8827M***
B41858C8108M***
B41858C8128M***
B41858C8158M***
B41858C8188M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm)
002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)
003 = for crimped leads, blister (for ∅ 16 ... 18 mm)
004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and
18 × 20 ... 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 33
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
Ordering code
(composition see
below)
VR = 100 V DC
22
8 × 11.5
33
10 × 16
47
10 × 20
100
12.5 × 20
120
12.5 × 25
180
12.5 × 30
180
16 × 20
220
16 × 25
270
12.5 × 40
270
18 × 20
330
16 × 31.5
330
18 × 25
390
18 × 31.5
470
18 × 35
560
18 × 35
680
18 × 40
12.219
6.542
3.688
3.048
2.038
1.732
1.313
0.985
1.314
1.260
0.973
1.008
0.720
0.679
0.679
0.438
1.222
0.654
0.461
0.305
0.204
0.173
0.131
0.099
0.131
0.126
0.097
0.101
0.072
0.068
0.068
0.044
1.114
0.589
0.423
0.281
0.188
0.159
0.122
0.091
0.121
0.119
0.090
0.095
0.068
0.063
0.063
0.042
205
357
460
647
864
1009
1119
1402
1309
1220
1546
1477
1907
2061
2061
2683
B41858C9226M***
B41858C9336M***
B41858C9476M***
B41858C9107M***
B41858C9127M***
B41858C9187M***
B41858D9187M***
B41858C9227M***
B41858C9277M***
B41858D9277M***
B41858C9337M***
B41858D9337M***
B41858C9397M***
B41858C9477M***
B41858C9567M***
B41858C9687M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm)
002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm)
003 = for crimped leads, blister (for ∅ 16 ... 18 mm)
004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and
18 × 20 ... 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 33
B41858
Low impedance 105 °C
Useful life1)
depending on ambient temperature TA under ripple current operating conditions
d = 8 mm
Useful life1)
depending on ambient temperature TA under ripple current operating conditions
d ≥ 10 mm
1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 33
B41858
Low impedance 105 °C
Frequency factor of permissible ripple current IAC versus frequency f
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 33
B41858
Low impedance 105 °C
Taping, packing and lead configurations
Taping
Single-ended capacitors are available taped in Ammo pack from diameter 8 to 18 mm as follows:
Lead spacing F = 3.5 mm (∅ d = 8 mm)
Lead spacing F = 5.0 mm (∅ d = 8 … 12.5 mm)
Lead spacing F = 7.5 mm (∅ d = 16 ... 18 mm).
The dimensions for F, P1 and 1 max. are specified with reference to the center of the terminal
wires.
Lead spacing 3.5 mm (∅ d = 8 mm)
Last 3 digits of ordering code: 006
Dimensions in mm
∅d
8
F
3.5
H
18.5
W
18.0
W0
9.5
W1
9.0
W2
3.0
P
12.7
P0
12.7
P1
4.6
I1
1.0
Toler- +0.8
±1.0
ance 0.2
±0.5
min.
±0.5
max. ±1.0
±0.3
±0.6
max. ±0.2
Leads can also run straight through the taping area.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 33
t
0.7
∆h
1.0
D0
4.0
max. ±0.2
B41858
Low impedance 105 °C
Lead spacing 5.0 mm (∅ d = 8 mm)
Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (∅ d = 10 ... 12.5 mm)
Last 3 digits of ordering code: 008
Dimensions in mm
∅d
8
H0
16.0
P
12.7
P0
12.7
P1
3.85
I1
t
∆h
D0
5.0
19.0 18.0 9.5 9.0 1.5
12.5
11.5
19.0
Toler- +0.8
±0.75 ±0.5 min. ±0.5 max. ±0.5
ance 0.2
12.7
12.7
3.85
1.0
0.6
1.0
4.0
15.0
15.0
5.0
±1.0
±0.2
±0.5
max.
+0.3
max. ±0.2
0.2
F
H
20.0
W
W0
9.5
10
W1
W2
Taping is available up to dimensions d × l = 12.5 × 25 mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 17 of 33
B41858
Low impedance 105 °C
Lead spacing 7.5 mm (∅ d = 16 ...18 mm)
Last 3 digits of ordering code: 009
Dimensions in mm
∅d
16
F
H
W
7.5 18.5 18.0
18
Toler0.5
±0.8
±0.5
ance
+0.75
W0
W1
W2
P
P0
P1
I1
t
∆P
∆h
D0
12.5
9.0
1.5
30.0
15.0
3.75
1.0
0.7
0
0
4.0
min.
±0.5
max. ±1.0
±0.2
±0.5
max. ±0.2 ±1.0 ±1.0 ±0.2
Taping is available up to dimensions d × l = 16 × 31.5 mm and 18 × 31.5 mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 18 of 33
B41858
Low impedance 105 °C
Cut or kinked leads
Single-ended capacitors are available with cut or kinked leads. Other lead configurations also
available upon request.
Cut leads
Last 3 digits of ordering code: 002
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 19 of 33
Dimensions (mm)
a ±0.5
10 × 12.5
5.0
10 × 16
5.0
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
16 × 35.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
B41858
Low impedance 105 °C
Kinked leads
Last 3 digits of ordering code: 001
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 20 of 33
Dimensions (mm)
a ±0.5
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
16 × 35.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
B41858
Low impedance 105 °C
PAPR leads (Protection Against Polarity Reversal)
These lead configurations ensure correct placement of the capacitor on the PCB with regard to
polarity. PAPR leads are available for diameters from 10 mm up to 18 mm (excluding
d × l = 12.5 × 30/35/40 mm).
There are three configurations available: Crimped leads, J leads, bent 90° leads.
Crimped leads
Last 3 digits of ordering code: 003
With stand-off rubber seal
With flat rubber seal
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
B ±0.2
C ±0.5
D ±0.1
E ±0.1
16 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 35.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
18 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 35
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 40
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 21 of 33
a ±0.5
∅b
B41858
Low impedance 105 °C
J leads
Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
J ±0.2
10 × 12.5
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 16
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 25
3.2
0.7
1.2
5.0
0.6 ±0.05
16 × 20
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 25
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 35.5
3.5
0.7
1.6
7.5
0.8 ±0.05
18 × 20
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 25
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 35
3.5
0.7
1.6
7.5
0.8 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 22 of 33
a ±0.5
∅b
B41858
Low impedance 105 °C
Bent 90° leads for horizontal mounting pinning
Last 3 digits of ordering code: 012
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
F ±0.5
a ±0.5
∅b
16 × 20
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 25
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 31.5
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 35.5
4.0
4.0
12.0
7.5
0.8 ±0.05
18 × 20
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 25
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 31.5
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 35
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 40
4.0
4.0
13.0
7.5
0.8 ±0.1
Bent leads for diameter 12.5 mm available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 23 of 33
B41858
Low impedance 105 °C
Packing units and box dimensions
Ammo pack
Please read Cautions and warnings and
Important notes at the end of this document.
Case size
d×l
mm
Dimensions (mm)
Amax
Bmax
Cmax
Packing
units
pcs.
8 × 11.5
345
60
240
1000
10 × 12.5
345
60
280
750
10 × 16
345
65
200
500
10 × 20
345
65
200
500
12.5 × 20
345
65
260
500
12.5 × 25
345
65
260
500
16 × 20
320
65
285
300
16 × 25
320
65
285
300
16 × 31.5
320
75
275
300
18 × 20
320
65
285
250
18 × 25
320
65
285
250
18 × 31.5
320
75
275
250
Page 24 of 33
B41858
Low impedance 105 °C
Overview of packing units and code numbers for case sizes 8 × 11.5 ... 16 × 35.5
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
leads,
bulk
pcs.
Crimped J leads,
leads,
blister
blister
pcs.
pcs.
1000
8 × 11.5
1000
10 × 12.5
1000
750
10 × 16
1000
500
1000
10 × 20
500
500
500
500
12.5 × 20
350
500
350
350
12.5 × 25
250
500
500
500
12.5 × 30
200
12.5 × 35
175
12.5 × 40
175
16 × 20
250
300
200
200
200
200
120
16 × 25
250
300
200
200
200
200
216
16 × 31.5
200
300
250
250
344
344
180
16 × 35.5
100
100
100
150
150
150
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code F (mm) d (mm)
001
002
003
004
012
006
008
009
3.5
5
7.5
8
8...12.5
16...18
1) Available upon request
Please read Cautions and warnings and
Important notes at the end of this document.
Page 25 of 33
1000
Bent 90°
leads,
blister
pcs.
675
675
500
300
1)
225
1)
B41858
Low impedance 105 °C
Overview of packing units and code numbers for case sizes 18 × 20 ... 18 × 40
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
leads,
bulk
pcs.
Crimped J leads,
leads,
blister
blister
pcs.
pcs.
Bent 90°
leads,
blister
pcs.
18 × 20
175
18 × 25
150
250
175
175
200
200
120
250
150
150
200
200
18 × 31.5
120
100
250
100
100
150
150
120
18 × 35
100
100
100
150
150
150
18 × 40
125
100
100
120
72
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code F (mm) d (mm)
001
002
003
004
012
009
Please read Cautions and warnings and
Important notes at the end of this document.
7.5
16...18
Page 26 of 33
B41858
Low impedance 105 °C
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have been optimized both with a view to the intended
application and with regard to health and environmental compatibility. They do not contain any
solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, some of the high-voltage electrolytes used by EPCOS are self-extinguishing.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no alternative materials are currently
known. However, the amount of dangerous materials used in our products is limited to an
absolute minimum.
Materials and chemicals used in EPCOS aluminum electrolytic capacitors are continuously
adapted in compliance with the EPCOS Corporate Environmental Policy and the latest EU
regulations and guidelines such as RoHS, REACH/SVHC, GADSL, and ELV.
MDS (Material Data Sheets) are available on the EPCOS website for all types listed in the data
book. MDS for customer specific capacitors are available upon request.
MSDS (Material Safety Data Sheets) are available for all of our electrolytes upon request.
Nevertheless, the following rules should be observed when handling aluminum electrolytic
capacitors: No electrolyte should come into contact with eyes or skin. If electrolyte does come
into contact with the skin, wash the affected areas immediately with running water. If the eyes are
affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical
treatment. Avoid inhaling electrolyte vapor or mists. Workplaces and other affected areas should
be well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 27 of 33
B41858
Low impedance 105 °C
Product safety
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic
Polarity
Reverse voltage
Mounting
position of screwterminal capacitors
Robustness of
terminals
Mounting of
single-ended
capacitors
Soldering
Soldering,
cleaning agents
Upper category
temperature
Passive
flammability
Safety information
Reference
chapter "General
technical information"
Make sure that polar capacitors are connected
1
with the right polarity.
"Basic construction of
aluminum electrolytic
capacitors"
Voltages of opposite polarity should be prevented 3.1.6
by connecting a diode.
"Reverse voltage"
Screw terminal capacitors must not be mounted
11.1.
with terminals facing down unless otherwise
"Mounting positions of
specified.
capacitors with screw
terminals"
The following maximum tightening torques must
11.3
not be exceeded when connecting screw
"Mounting torques"
terminals:
M5: 2.5 Nm
M6: 4.0 Nm
The internal structure of single-ended capacitors 11.4
might be damaged if excessive force is applied to "Mounting
the lead wires.
considerations for
Avoid any compressive, tensile or flexural stress. single-ended capacitors"
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
Do not exceed the specified time or temperature 11.5
limits during soldering.
"Soldering"
Do not allow halogenated hydrocarbons to come 11.6
into contact with aluminum electrolytic capacitors. "Cleaning agents"
Do not exceed the upper category temperature.
7.2
"Maximum permissible
operating temperature"
Avoid external energy, e.g. fire.
8.1
"Passive flammability"
Please read Cautions and warnings and
Important notes at the end of this document.
Page 28 of 33
B41858
Low impedance 105 °C
Topic
Safety information
Active
flammability
Maintenance
Avoid overload of the capacitors.
Storage
Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply excessive mechanical stress to the
capacitor terminals when mounting.
Do not store capacitors at high temperatures or
high humidity. Capacitors should be stored at
+5 to +35 °C and a relative humidity of ≤ 75%.
Breakdown strength Do not damage the insulating sleeve, especially
of insulating
when ring clips are used for mounting.
sleeves
Reference
chapter "General
technical information"
8.2
"Active flammability"
10
"Maintenance"
7.3
"Shelf life and storage
conditions"
Reference
chapter "Capacitors with
screw terminals"
"Screw terminals accessories"
Display of ordering codes for EPCOS products
The ordering code for one and the same product can be represented differently in data sheets,
data books, other publications and the website of EPCOS, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the specifications of the
respective products. Detailed information can be found on the Internet under
www.epcos.com/orderingcodes.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 29 of 33
B41858
Low impedance 105 °C
Symbols and terms
Symbol
English
German
C
CR
CS
CS,T
Cf
d
dmax
ESL
ESR
ESRf
Capacitance
Rated capacitance
Series capacitance
Series capacitance at temperature T
Capacitance at frequency f
Case diameter, nominal dimension
Maximum case diameter
Self-inductance
Equivalent series resistance
Equivalent series resistance at
frequency f
Equivalent series resistance at
temperature T
Frequency
Current
Alternating current (ripple current)
Root-mean-square value of alternating
current
Ripple current at frequency f
Maximum permissible ripple current
Rated ripple current
Leakage current
Operating leakage current
Case length, nominal dimension
Maximum case length (without
terminals and mounting stud)
Resistance
Insulation resistance
Balancing resistance
Temperature
Temperature difference
Ambient temperature
Case temperature
Capacitor base temperature
Time
Period
Service life (operating hours)
Kapazität
Nennkapazität
Serienkapazität
Serienkapazität bei Temperatur T
Kapazität bei Frequenz f
Gehäusedurchmesser, Nennmaß
Maximaler Gehäusedurchmesser
Eigeninduktivität
Ersatzserienwiderstand
Ersatzserienwiderstand bei Frequenz f
ESRT
f
I
IAC
IAC,RMS
IAC,f
IAC,max
IAC,R
Ileak
Ileak,op
l
lmax
R
Rins
Rsymm
T
∆T
TA
TC
TB
t
∆t
tb
Please read Cautions and warnings and
Important notes at the end of this document.
Ersatzserienwiderstand bei Temperatur T
Frequenz
Strom
Wechselstrom
Wechselstrom, Effektivwert
Wechselstrom bei Frequenz f
Maximal zulässiger Wechselstrom
Nennwechselstrom
Reststrom
Betriebsreststrom
Gehäuselänge, Nennmaß
Maximale Gehäuselänge (ohne Anschlüsse
und Gewindebolzen)
Widerstand
Isolationswiderstand
Symmetrierwiderstand
Temperatur
Temperaturdifferenz
Umgebungstemperatur
Gehäusetemperatur
Temperatur des Gehäusebodens
Zeit
Zeitraum
Brauchbarkeitsdauer (Betriebszeit)
Page 30 of 33
B41858
Low impedance 105 °C
Symbol
V
VF
Vop
VR
VS
XC
XL
Z
ZT
tan δ
λ
ε0
εr
ω
English
Voltage
Forming voltage
Operating voltage
Rated voltage, DC voltage
Surge voltage
Capacitive reactance
Inductive reactance
Impedance
Impedance at temperature T
Dissipation factor
Failure rate
Absolute permittivity
Relative permittivity
Angular velocity; 2 π f
German
Spannung
Formierspannung
Betriebsspannung
Nennspannung, Gleichspannung
Spitzenspannung
Kapazitiver Blindwiderstand
Induktiver Blindwiderstand
Scheinwiderstand
Scheinwiderstand bei Temperatur T
Verlustfaktor
Ausfallrate
Elektrische Feldkonstante
Dielektrizitätszahl
Kreisfrequenz; 2 π f
Note
All dimensions are given in mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 31 of 33
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
Page 32 of 33
Important notes
7. The trade names EPCOS, Alu-X, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP,
CTVS, DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue,
MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine,
SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D,
SIP5K, TFAP, ThermoFuse, WindCap are trademarks registered or pending in Europe and
in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.
Page 33 of 33
Similar pages