Double-throw safety switch Industrial Light Commercial Residential Agricultural An economical means of transferring power Double-throw safety switches Eaton’s double-throw safety switches are used to transfer service from a normal power source to an alternate source, or to switch from one load circuit to another. The manually operated double-throw safety switch provides an economical means of transferring power. Eaton offers a full line of general-duty and heavy-duty double-throw safety switches. Double-throw general-duty non-fusible safety switches Double-throw, 240 Vac general-duty, non-fusible compact design Specifications • 30–100A Specifications • Suitable for service entrance use with neutral kit installed • 30–400A • Horsepower rated • Suitable for service entrance use with neutral kit installed • Suitable for use as a manually operated switch per 2005 NEC Article 702 • UL listed File No. E5239 • Quick-make, quick-break operating mechanism • Suitable for use as a manually operated switch per 2005 NEC� Article 702 • UL� listed File No. E5239 Features General-duty Heavy-duty Eaton’s general-duty doublethrow safety switches are commonly applied in emergency power or generator applications to reduce or eliminate the costly impact of power loss from the typical source in residential, agricultural and light commercial markets. All general-duty double-throw safety switches are non-fusible and are available up to 400A. Eaton’s heavy-duty doublethrow safety switches are designed for commercial and industrial applications. Fusible switches are available through 600A, while non-fusible switches are manufactured up to 800A. The wiring configuration from the factory allows a single load to be supplied by a normal or alternate source; however, where necessary, the wiring can be field modified to allow two loads to be alternately supplied by a single power source. A standby generator connected to a residential wiring system must be installed according to the National Electrical Code.� A double-throw switch must be installed to isolate and disconnect wiring from normal utility lines so that generator-produced electricity is not back-fed onto normal utility lines. Whether normal electrical service is disrupted by severe weather conditions, accidents or other issues, an Eaton generalduty double-throw safety switch is a critical component in your standby generator applications. Heavy-duty double-throw safety switches are designed to accommodate a wide range of accessories that can be factory or field installed. Customized solutions, including key interlocks, viewing windows and receptacles, are also available through Eaton’s Switching Device Flex Center. Double-throw, 240 Vac general-duty, non-fusible, quick-make, quick-break design • Palm-fitting, visible red handle • Tri-lingual nameplate • NEMA� 3R enclosure with side opening door • Visible, embossed ON-OFF indication • Concentric knockouts on bottom endwall and sides • Lockable door hasp • Lockable handle • Three-point mounting • Factory-installed neutral (optional catalog numbers are available without a neutral) • Terminals suitable for 60º or 75ºC Al or Cu wire • Rounded shroud • • • Mechanical door interlock to prevent easy access when the switch is in the ON position Suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes Compact size • Door cannot be opened with the switch ON. Switch cannot be turned ON with door open (without operating interlock defeater) • Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes when protected by Class R or J fuses (30–200A); R, T or J fuses (400A). Short-circuit rating is 10,000 rms symmetrical amperes when protected by any other overcurrent protective device • Double-break visible rotary blades; quick-make, quickbreak operation DT223URH-N Compact Design, 100A, 240V DT224URK-NPS Quick-Make, Quick-Break Design, 200A, 240V. Features • Palm-fitting, visible red handle Double-Throw Compact Design NEMA 3R Enclosure Rainproof Ampere Rating Main and Standby ON • Tri-lingual nameplate • NEMA 3R enclosure with side opening door • Visible, embossed red ON-OFF indication 30 60 100 Tangential knockouts (30–100A) on bottom endwall; concentric knockouts on higher ratings, and sides and rear of 30–100A Non-Fusible Two-Pole, Three-Wire—240 Vac—Solid Neutral 30 DT221URH-N ON 60 DT222URH-N OFF 100 DT223URH-N ON • • Lockable door hasp • Lockable handle • Factory-installed neutral (optional catalog numbers are available without a neutral) • Three-point mounting (30–100A) • Four-point mounting (200–400A) • Terminals suitable for 60º or 75ºC Al or Cu wire on 30–100A; 75ºC Al or Cu wire on higher ratings • Rounded shroud OFF Catalog Number S/N ON DT221URH DT222URH DT223URH ON Non-Fusible Two-Pole—240 Vac Non-Fusible Two-Pole OFF ON S/N Double-Throw Quick-Make, Quick-Break Design Ampere Rating Main and Standby Maximum Horsepower Ratings Non-Fusible Two-Pole with Neutral Two Sources or Two Loads ON OFF ON Single-Phase NEMA 3R Enclosure Rainproof 240 Vac Catalog Number 250 Vdc Two Sources or Two Loads ON S/N OFF ON Non-Fusible Two-Pole—240 Vac—250 Vdc 30 3 5 DT221URKPS Non-Fusible ON 60 10 10 DT222URKPS Two-Pole OFF 100 20 20 DT223URKPS Two Sources or ON 200 15 40 DT224URKPS Two Loads 400 — 50 DT225URKPS Non-Fusible Two-Pole, Three-Wire—240 Vac—250 Vdc—Solid Neutral 30 3 5 DT221URK-NPS 60 10 10 DT222URK-NPS 100 20 20 DT223URK-NPS Non-Fusible ON 200 15 40 DT224URK-NPS Two-Pole with OFF Neutral 400 — 50 DT225URK-NPS S/N ON Two Sources or Two Loads ON OFF 2 EATON CORPORATION Double-throw safety switch EATON CORPORATION Double-throw safety switch ON 3 Double-throw heavy-duty fusible safety switches Double-throw heavy-duty non-fusible safety switches DT363URK Double-throw Heavy-Duty NonFusible Safety Switch, 100A, 600V DT363FGK Double-throw Heavy-Duty Fusible Safety Switch, 100A, 600V Double-throw 240 and 600 Vac heavy-duty, fusible Features Specifications 30–600A • Horsepower rated • • Palm-fitting, visible red handle • Tri-lingual nameplate • Side opening doors on all enclosures • Suitable for service entrance use with neutral or ground lug kit installed • Suitable for use as a manually operated switch per 2005 NEC Article 702 • • UL listed File No E5239 • • • Clear line shield to prevent accidental contact with energized parts; probe holes enable line side testing without removing the shield Wiring configuration from factory allows a single load to be supplied by a normal or alternate source; can be modified to allow two loads to be alternately supplied by a single power source Visible, embossed red ON-OFF indication Tangential knockouts (30–100A) on top and bottom endwall (bottom only on NEMA 3R); concentric knockouts on higher ratings, and sides and rear of 30–100A • Lockable door hasp • Lockable handle • Three-point mounting (30–100A) • • • • Four-point mounting (200–600A) Terminals suitable for 60º or 75ºC Al or Cu wire on 30–100A; 75ºC Al or Cu wire on higher ratings • Rounded shroud • Full range of accessories • Door cannot be opened with the switch ON. Switch cannot be turned ON with door open (without operating interlock defeater) Double-throw 240 and 600 Vac heavy-duty, non-fusible Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes when protected by Class R or J fuses (30–200A); R, T or J fuses (400–600A). Short-circuit rating is 10,000 rms symmetrical amperes when protected by any other overcurrent protective device Specifications • Suitable for use as a manually operated switch per 2005 NEC Article 702 Double-break visible rotary blades; quick-make, quickbreak operation • UL listed File No. E5239 • 30–800A • Horsepower rated • Suitable for service entrance use with neutral or ground lug kit installed Fuse Class Provision Maximum Horsepower Ratings with Time-Delay Fuses NEMA 1 Enclosure Indoor NEMA 3R Enclosure Rainproof Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc Catalog Number Catalog Number — DT224FGK DT224FRK Two-Pole—240 Vac—250 Vdc 200 H 15 40 Ampere Rating Main and Standby OFF ON 7-1/2 15 30 60 125 50 DT321FGK DT322FGK DT323FGK DT324FGK DT325FGK DT326FGK 5 10 20 40 50 50 DT321FRK DT322FRK DT323FRK DT324FRK DT325FRK DT326FRK Palm-fitting, visible red handle • Tri-lingual nameplate • Side opening doors on all enclosures • Visible, embossed red ON-OFF indication • Tangential knockouts (30–100A) on top and bottom endwall (bottom only on NEMA 3R); concentric knockouts on higher ratings, and sides and rear of 30–100A • Lockable door hasp • Lockable handle Maximum Horsepower Ratings ON Three-Pole—240 Vac—250 Vdc 30 H 3 60 H 10 100 H 15 200 H 15 400 H — 600 1 T — • ON OFF ON Fusible Two-Pole Two Sources Fusible Three-Pole Two Sources ON OFF ON ON OFF ON Fusible Two-Pole Two Loads Fusible Three-Pole Two Loads A Only available for use with fast-acting fuses. Standard hp rating is shown. • Three-point mounting (30–100A) • Four-point mounting (200–800A) • Terminals suitable for 60º or 75ºC Al or Cu wire on 30–100A; 75ºC Al or Cu wire on higher ratings • Rounded shroud • Full range of accessories • Door cannot be opened with the switch ON; switch cannot be turned ON with door open (without operating interlock defeater) • Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes when protected by Class R or J fuses (30–200A); R, T or J fuses (400–800A). Short-circuit rating is 10,000 rms symmetrical amperes when protected by any other overcurrent protective device • Double-break visible rotary blades; quick-make, quickbreak operation Double-Throw 240 Vac Heavy-Duty, Non-Fusible Double-Throw 240 Vac Heavy-Duty, Fusible Ampere Rating Main and Standby Features SinglePhase Three-Phase NEMA 1 Enclosure Indoor NEMA 3R Enclosure Rainproof 240 Vac 240 Vac Catalog Number Catalog Number DT221UGK DT222UGK DT223UGK DT224UGK DT225UGK DT226UGK — — — DT224URK DT225URK — DT321UGK DT322UGK DT323UGK DT324UGK DT325UGK DT326UGK DT327UGK 1 2 DT327UGK-N — — DT323URK DT324URK DT325URK — — — 250 Vdc Non-Fusible Two-Pole—240 Vac—250 Vdc 30 3 — 5 60 10 — 10 100 20 — 20 200 15 — 40 400 — — 50 600 — — — Non Fusible Three-Pole—240 Vac—250 Vdc 30 3 10 5 60 10 20 10 100 20 40 20 200 15 60 40 400 — 125 50 600 — 125 50 800 — 125 50 800 — 125 50 ON OFF ON ON OFF ON Non-Fusible 2-Pole Two Sources or Two Loads ON Non-Fusible 3-Pole Two Sources or Two Loads OFF S/N ON Non-Fusible 3-Pole with Neutral Two Sources or Two Loads A Warning: Switch is not approved for service entrance. B Field-installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with “N” suffix. Double-Throw 600 Vac Heavy-Duty, Fusible Ampere Rating Main and Standby Maximum Horsepower Ratings with Time-Delay Fuses Fuse Class Provision Single-Phase Three-Phase 480 Vac 600 Vac 480 Vac 600 Vac 10 25 40 50 — 15 30 60 125 250 20 50 75 150 350 Three-Pole—600 Vac—250 Vdc 30 H 7-1/2 60 H 20 100 H 30 200 H 50 400 T — 4 EATON CORPORATION Double-throw safety switch NEMA 1 Enclosure Indoor NEMA 3R Enclosure Rainproof NEMA 4X Enclosure, Corrosion-Resistant Stainless Steel 250 Vdc Catalog Number Catalog Number Catalog Number — — — 40 50 DT361FGK DT362FGK DT363FGK DT364FGK DT365FGK — — DT363FRK DT364FRK DT365FRK DT361FWK DT362FWK DT363FWK DT364FWK DT365FWK Fusible Three-Pole Two Sources ON OFF ON Fusible Three-Pole Two Loads EATON CORPORATION Double-throw safety switch 5 Double-throw heavy-duty non-fusible safety switches Double-throw heavy-duty switching neutral safety switches Double-Throw 600 Vac Heavy-Duty, Non-Fusible Maximum Horsepower Ratings Ampere Rating Main and Standby Single-Phase NEMA 3R Enclosure Rainproof NEMA 12 Enclosure Industrial, Dust-Tight NEMA 4X Enclosure, Corrosion-Resistant, Stainless Steel 480 Vdc Catalog Number Catalog Number Catalog Number Catalog Number Three-Phase 480 Vac 600 Vac 480 Vac 600 Vac Two-Pole—600 Vac—250 Vdc 30 7-1/2 10 60 20 25 100 40 50 200 50 50 400 — — 600 — — Three-Pole—600 Vac—250 Vdc 30 7-1/2 10 60 20 25 100 40 50 200 50 50 400 — — 600 — — 800 — — 800 — — NEMA 1 Enclosure Indoor — — — — — — — — — — — — 5 10 20 40 50 50 DT261UGK DT262UGK DT263UGK DT264UGK 1 DT265UGK DT266UGK — — — DT264URK 1 DT265URK DT266URK — — — — — — — — — — — — 20 50 75 125 250 250 250 250 30 60 100 150 350 350 350 350 5 10 20 40 50 50 50 50 DT361UGK DT362UGK DT363UGK DT364UGK DT365UGK DT366UGK DT367UGK 2 3 DT367UGK-N DT361URK DT362URK DT363URK DT364URK DT365URK DT366URK DT367URK 2 3 DT367URK-N DT361UDK 4 DT362UDK 4 DT363UDK 4 DT364UDK 4 DT365UDK 4 5 —4 —4 —4 DT361UWK DT362UWK DT363UWK DT364UWK DT365UWK — — — 30 60 100 150 350 350 350 5 10 20 40 50 50 50 — — — DT464UGK DT465UGK DT466UGK DT467UGK DT461URK DT462URK DT463URK DT464URK DT465URK DT466URK DT467URK — — — — — — — — — — — — — — 30 60 100 5 10 20 — — — DT661URK DT662URK DT663URK — — — — — — Two-Pole OFF Two Sources or Two Loads ON S/N Four-Pole—600 Vac—250 Vdc 2 30 7-1/2 10 20 60 20 25 50 100 40 50 75 200 — 50 125 400 — — 250 600 — — 250 800 — — 250 Six-Pole—600 Vac—250 Vdc 2 30 7-1/2 10 15 60 20 25 50 100 40 50 75 Non-Fusible ON Non-Fusible ON Three-Pole OFF Two Sources or Two Loads ON Non-Fusible ON Three-Pole with Neutral OFF Two Sources or Two Loads ON Non-Fusible ON OFF ON Four-Pole Two Sources or Two Loads ON OFF ON A Rated 600 Vdc, 50 hp in addition to ratings shown in table. B Warning: Switch is not approved for service entrance. C Field-installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with “N” suffix. D NEMA 12 enclosures (30–800A) can be field modified to meet NEMA 3R rainproof requirements when a factory-provided drain hole is opened. E Also available in 240 Vac, catalog number DT325UDK. Non-Fusible Six-Pole Two Sources or Two Loads Double-throw safety switches applied in emergency power or generator applications may require a switched neutral in lieu of a solid neutral. If the neutral of the generator is bonded to a grounding system at the generator, then a separately derived system (reference NEC 250-20[D] and Exhibit 250.7) has been created and a switched neutral in the double-throw safety switch is required. The switching neutral is required to avoid the potential for backfeeding of the power that might occur if the safety switch neutral is also bonded. If the generator neutral is brought to the service where it is bonded and grounded, then a non-separately derived system has been created and a solid neutral must be used in the double-throw safety switch. Most double-throw safety switches in today’s market are provided with solid neutrals and are not UL listed for switching neutral application. The market, some utilities and local codes are requiring the ability to break or switch the neutral on threeand four-pole double-throw switches with a UL listing for that capability. Three-pole switches are used for single-phase switching neutral applications, while four-pole switches are used for three-phase switching neutral applications. In many cases, threeand four-pole double-throw safety switches are being installed in the field with the left-most pole being used as the switching neutral, but the switch is not UL listed for that application. Eaton non-fusible three-pole and four-pole double-throw safety switches 30–800A are UL listed for switching neutral application with the proper installation of the applicable switching neutral bonding kit shown in the Accessories section of this brochure. Each bonding kit comes with applicable materials, hardware, instruction sheet and adhesive-backed wiring schematic. The bonding kits can only be used on non-fusible double-throw safety switches. When a bonding kit is applied to a three-pole switch, the switch becomes a single-phase switch with singlephase horsepower ratings. A double-throw safety switch with the appropriate bonding kit installed is suitable for service entrance use. Typically, a four-pole double-throw safety switch is not suitable for service entrance use; however, with the appropriate bonding kit installed, the fourpole switch is suitable for service entrance use as noted on the device publication of the product. Switching neutral bonding kits can also be factory installed by Eaton’s unique Switching Device Flex Center. See the end of this brochure for additional information on the Flex Center. Bonding kit schematic Single-phase applications requiring a neutral pole bonding kit Bonding kit schematic Three-phase applications requiring a neutral pole bonding kit NNotes: NEC 702 application, separately derived system and service equipment. Two sources with switched neutral, generator is a separately derived system. Proper installation is governed by interpretation of the NEC, applicable local codes and local utility requirements. Applicable sections of these codes and requirements should be referenced prior to installation. Double-Throw Switching Neutral Safety Switch (upper switch base assembly is shown) 6 EATON CORPORATION Double-throw safety switch EATON CORPORATION Double-throw safety switch 7 Accessories, hubs and standard lug capacities 1. DT200NK 200A Neutral/Ground Kit 2. DS250H2 Plate Type Hub 3. DS26FK 60A 600V R Fuse Adapter Kit Accessories Hubs Neutral, ground lug, control pole and auxiliary contact kits contain materials for one switch base. Copper lug, 60A J fuse and R fuse kits contain materials for one three-pole switch base. Switching neutral bonding and 400A J fuse kit contents are for one complete double-throw switch. Applicable accessories for a specific safety switch can also be found on the inside door publication of the switch Catalog Number DS900AP Adapter Kit permits installation of Group 1 hubs on 200A double-throw switches. Description Catalog Number Neutral Kits/Ground Kits 1 30–100A 200A 400A Non-Fusible 600A Non-Fusible 400–600A Fusible Ground Lug Kits 1 30–100A 2 200A 400–800A Switching Neutral Bonding Kits 3 30–100A, Three-Pole, Four-Pole Non-Fusible 200A, Three-Pole, Four-Pole Non-Fusible 400A, Three-Pole, Four-Pole Non-Fusible 600A, Three-Pole, Four-Pole Non-Fusible 800A, Three-Pole, Four-Pole Non-Fusible Control Pole Kit 1 30–800A Auxiliary Contact Kits 1 1NO/1NC 2NO/2NC Copper Lug Kits 1 30–60A 100A J Fuse Adapter Kits 4 60A 400A 600V R Fuse Adapter Kits 4 30A, 240V 30A, 600V; 60A, 240V 60A, 600V 100A, 240–600V 200A, 240–600V 400A, 240V Lubricating Grease for Safety Switch Blades and Contacts Each kit contains three 30 cc tubes of lubricating grease. DT100NK DT200NK DT400NK DT600NK DS800NK DS100GK DS200GK DS468GK DT100BK DT200BK DT400BK DT600BK DT800BK DS16CP 7. DS200EK1 Auxiliary Contact Kit 1NO/1NC 5. DS468GK 400–800A Ground Lug Kit 8. DS16CP Control Pole Kit 6. DS050MH Myers Hub 9. DS26JK 60A J Fuse Adapter Kit 10. DS16CL 30–60A Copper Lug Kit 1 2 3 4 5 6 7 8 9 10 Plate Type Hubs For NEMA 3R Enclosures (Up to 200A) Group 1 General-Duty, Heavy-Duty, Double-Throw through 100A Group 2 General-Duty, Heavy-Duty, Double-Throw through 200A Conduit Size in Inches (mm) Catalog Number Conduit Size in Inches (mm) Catalog Number 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) DS075H1 DS100H1 DS125H1 DS150H1 DS200H1 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) — — — — DS200H2 DS250H2 DS300H2 — — Myers Type Hubs NEMA 3R (400A and Above) NEMA 4X (Stainless Steel) and 12 Conduit Size in Inches (mm) Catalog Number 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) 3.50 (88.9) 4.00 (101.6) 5.00 (127.0) DS050MH DS075MH DS100MH DS125MH DS150MH DS200MH DS250MH DS300MH DS350MH DS400MH DS500MH DS200EK1 DS200EK2 Standard lug capacities DS16CL DS36CL DS26JK DT400JK DS12FK DS16FK DS26FK DS36FK DS46FK DS56FK DSLUBEKIT A For heavy-duty and general-duty quick-make, quick-break. B Ground bar kit is not listed on device publications. C For heavy-duty non-fusible. D For heavy-duty fusible. 8 4. DT100BK 100A Switching Neutral Bonding Kit EATON CORPORATION Double-throw safety switch Although certain lug capacities are larger than required, only minimum wire bending space is provided per the requirements noted in NEC Tables 373-6 (a) and (b) for respective ampere ratings. Description 30A 60A 100A 200A 400A 600A Fusible 600A Non-Fusible 800A Copper-Bodied Lugs 30A 60A 100A 200A 400A 600A Minimum Wire Size Maximum Wire Size Wire Type #14 #14 #14 #6 (2) #1/0 (1) #1/0 (1) #2 (1) #1/0 (2) #250 (3) #250 #2 #2 #1/0 250 kcmil (2) 300 kcmil (1) 750 kcmil (1) 600 kcmil (1) 750 kcmil (2) 500 kcmil (3) 500 kcmil Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al #14 #14 #6 #6 #1/0 (2) #1/0 #6 #4 #1/0 250 kcmil 500 kcmil (2) 500 kcmil Cu Cu Cu Cu Cu Cu EATON CORPORATION Double-throw safety switch 9 Dimensions and weights 1 2 W W H 2. Heavy-Duty NEMA 1, 3R 30–800A H CL 3. Heavy-Duty NEMA 12, 4X 30–400A H Note Contact your Eaton sales office for outline drawings and mounting dimensions. D2 NEMA 3R Dimensions in Inches (mm) Short-Circuit Ratings Using Class R, T or J Fusing Where Applicable Class H fuse clips supplied as standard for 30–600A except Class T for 400A at 600V, and 600A at 240V. Rated at 10,000 rms symmetrical when using Class H fuses. D2 Double-Throw General-Duty, Non-Fusible, 240V, Two-Pole Solid Neutral, Quick-Make, Quick-Break Design 30 60 100 200 400 D W D D2 Ampere Rating 1. General-Duty NEMA 3R 30–400A 3 D CL Short-circuit ratings Double-Throw General-Duty, Non-Fusible, 240V, Two-Pole Solid Neutral, Compact Design Height (H) Width (W) Depth (D) Depth (D2) Weight Lbs (kg) Ampere Rating 24.63 (625.6) 24.63 (625.6) 24.63 (625.6) 37.38 (949.5) 53.81 (1366.8) 11.94 (303.3) 11.94 (303.3) 11.94 (303.3) 19.56 (496.8) 23.13 (587.5) 9.88 (251.0) 9.88 (251.0) 9.88 (251.0) 11.25 (285.8) 12.50 (317.5) 5.38 (136.7) 5.38 (136.7) 5.38 (136.7) 6.10 (154.9) 8.88 (225.6) 34 (15.4) 34 (15.4) 34 (15.4) 80 (36.3) 140 (63.6) 30 60 100 NEMA 3R Dimensions in Inches (mm) Height (H) Width (W) Depth (D) Depth (D2) Weight Lbs (kg) 14.69 (373.1) 14.69 (373.1) 14.69 (373.1) 9.63 (244.6) 9.63 (244.6) 9.63 (244.6) 10.81 (274.6) 10.81 (274.6) 10.81 (274.6) 5.23 (132.8) 5.23 (132.8) 5.23 (132.8) 12 (5.4) 12 (5.4) 12 (5.4) Not applicable to the Compact Design. The Compact Design is suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes. Ampere Rating Voltage Ratings Type 1 Type 3R Type 12 Type 4X 30 60 100 200 400 600 800 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 — 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 — Double-Throw Heavy-Duty, Non-Fusible, 240V and 600V, Three-Pole NEMA 1, 3R Dimensions in Inches (mm) NEMA 12, 4X Stainless Steel Dimensions in Inches (mm) Ampere Rating Width (W) Height (H) Depth (D) Depth (D2) Weight Lbs (kg) Width (W) Height (H) Depth (D) Depth (D2) Weight Lbs (kg) 30 11.94 (303.3) 11.94 (303.3) 11.94 (303.3) 19.56 (496.8) 23.13 (587.5) 24.13 (612.9) 24.13 (612.9) 24.63 (625.6) 24.63 (625.6) 24.63 (625.6) 37.38 (949.5) 53.81 (1366.8) 63.31 (1608.1) 63.31 (1608.1) 9.88 (251.0) 9.88 (251.0) 9.88 (251.0) 11.25 (285.8) 12.50 (317.5) 14.13 (358.9) 14.13 (358.9) 5.38 (136.7) 5.38 (136.7) 5.38 (136.7) 6.10 (154.9) 7.25 (184.2) 8.88 (225.6) 8.88 (225.6) 34 (15.4) 34 (15.4) 34 (15.4) 80 (36.3) 140 (63.6) 175 (79.4) 175 (79.4) 12.00 (304.8) 12.00 (304.8) 12.00 (304.8) 19.50 (495.3) 23.00 (584.2) — 25.88 (657.4) 25.88 (657.4) 25.88 (657.4) 41.00 (1041.4) 57.50 (1460.5) — 10.25 (260.4) 10.25 (260.4) 10.25 (260.4) 11.63 (295.4) 12.50 (317.5) — 5.50 (139.7) 5.50 (139.7) 5.50 (139.7) 6.48 (164.6) 7.25 (184.2) — 60 (27.2) 60 (27.2) 60 (27.2) 105 (47.6) 185 (83.9) — — — — — — 60 100 200 400 600 800 Double-Throw Heavy-Duty, Fusible, 240V and 600V, Three-Pole NEMA 1, 3R Dimensions in Inches (mm) NEMA 12, 4X Stainless Steel Dimensions in Inches (mm) Ampere Rating Width (W) Height (H) Depth (D) Depth (D2) Weight Lbs (kg) Width (W) Height (H) Depth (D) Depth (D2) Weight Lbs (kg) 30 11.94 (303.3) 11.94 (303.3) 11.94 (303.3) 19.56 (496.8) 25.38 (644.7) 27.44 (697.0) 36.63 (930.4) 36.63 (930.4) 36.63 (930.4) 50.88 (1292.4) 74.75 (1898.7) 86.13 (2187.7) 9.88 (251.0) 9.88 (251.0) 9.88 (251.0) 11.25 (285.8) 14.13 (358.9) 14.13 (358.9) 5.38 (136.7) 5.38 (136.7) 5.38 (136.7) 6.10 (154.9) 8.88 (225.6) 8.88 (225.6) 44 (20.0) 44 (20.0) 44 (20.0) 95 (43.1) 230 (104.3) 320 (145.1) 12.00 (304.8) 12.00 (304.8) 12.00 (304.8) 19.56 (496.8) 25.38 (644.7) — 39.81 (1011.2) 39.81 (1011.2) 39.81 (1011.2) 55.63 (1413.0) 74.75 (1898.7) — 10.25 (260.4) 10.25 (260.4) 10.25 (260.4) 11.63 (295.4) 14.13 (358.9) — 5.50 (139.7) 5.50 (139.7) 5.50 (139.7) 6.46 (164.1) 8.92 (226.6) — 45 (20.4) 45 (20.4) 45 (20.4) 100 (45.4) 260 (117.9) — 60 100 200 400 600 10 EATON CORPORATION Double-throw safety switch Non-fusible switches Renewal parts The UL listed short-circuit ratings for Eaton non-fusible switches are based on the switches being properly protected by overcurrent protective devices. For applications that require a UL listed short-circuit rating of 10,000 rms symmetrical amperes or less, an Eaton nonfusible switch must be properly protected by any overcurrent protective device rated no greater than the ampere rating of the switch. For applications that require a UL listed short-circuit rating of greater than 10,000 rms symmetrical amperes, an Eaton non-fusible switch must be properly protected by the appropriate class and size fusing noted on the switch publication. Otherwise, this non-fusible switch must be replaced with an Eaton fusible switch that uses the appropriate fusing required. Replacement parts for a specific catalog number are shown on the inside door label (publication) of the switch. Switch bases, fuse bases, line shields (fusible switches) and operating handles (400A and above) are typically available as applicable. For additional information, refer to Renewal Parts Catalog RP00801001E. Safety switch short circuit ratings are applicable to AC only. Flex center Our Cleveland, TN, Switching Devices Flex Center is a solutions center that designs and modifies safety switches, enclosed circuit breakers and rotary disconnects for unique customer needs that are not met by standard products. The Flex Center is a one-of-a-kind operation that is capable of solving our customers’ issues, while our competition is content to offer their customers only catalog items. The Flex Center staff has over 120 years of design, manufacturing and industry experience, and has been providing solutions to our customers since 1998. While you may think that your power switching needs are unlike any other, chances are, the Flex Center staff has already “been there, done that.” For further information on our customized solutions for harsh environments, safety and convenience, please refer to our Flex Center brochure SA00801002E or contact the Flex Center at 1-888-329-9272. Safety switch I2t and Ip values are identical to UL maximum acceptable I2t and Ip values for the corresponding class fuse. EATON CORPORATION Double-throw safety switch 11 Eaton’s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton’s full-scale engineering services, these products provide customerdriven PowerChainE solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. PowerChain solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com © 2010 Eaton Corporation All Rights Reserved Printed in USA Publication No. BR00801002E / Z10432 November 2010 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.