ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Values
Unit
VR
Maximum D.C. Reverse Voltage
700
V
VRRM
Maximum Repetitive Reverse Voltage
700
V
TC=90°C, Per Diode
100
A
TC=90°C, Per Moudle
200
A
TC=90°C, 20KHz, Per Moudle
150
A
RMS Forward Current
TC=90°C, Per Diode
150
A
Non-Repetitive Surge
TJ=45°C, t=10ms, 50Hz, Sine
1100
A
Forward Current
TJ=45°C, t=8.3ms, 60Hz, Sine
1200
A
TJ=45°C, t=10ms, 50Hz, Sine
6050
A2s
TJ=45°C, t=8.3ms, 60Hz, Sine
7200
A2s
370
W
IF(AV)
IF(RMS)
IFSM
Average Forward Current
I2t
I2t (For Fusing)
PD
Power Dissipation
TJ
Junction Temperature
-40 to +150
°C
TSTG
Storage Temperature Range
-40 to +125
°C
Visol
Insulation Test Voltage
AC, t=1min
3000
V
Torque
Module-to-Sink
Recommended(M5)
2.5~4
N·m
Torque
Module Electrodes
Recommended(M5)
2.5~4
N·m
RθJC
Thermal Resistance
Junction-to-Case
0.34
°C /W
100
g
Weight
MIMMF200N070DA
MIMMF200N070DK
ELECTRICAL CHARACTERISTICS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Min.
Typ.
Max.
Unit
VR=700V
--
--
1
mA
VR=700V, TJ=125°C
--
--
2
mA
IF=100A
--
1.55
1.9
V
IF=100A, TJ=125°C
--
--
1.6
V
Reverse Leakage Current
VF
Forward Voltage
trr
Reverse Recovery Time
IF=1A, VR=30V, diF/dt=-200A/μs
--
38
--
ns
trr
Reverse Recovery Time
VR=350V, IF=100A
--
85
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=25°C
--
10
--
A
trr
Reverse Recovery Time
VR=350V, IF=100A
--
180
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=125°C
--
22
--
A
250
500
200
400
150
300
trr (ns)
IF (A)
IRM
TJ =125°C
VR=350V
TJ =125°C
200
100
TJ =25°C
50
100 IF=200A
IF=100A
0
0
0
1
1.5
2.5
2
0.5
VF(V)
Figure1. Forward Voltage Drop vs Forward Current
100
IF=50A
0
400
600
800
1000
diF/dt(A/μs)
Figure2. Reverse Recovery Time vs diF/dt
5
VR=350V
TJ =125°C
80
200
VR=350V
TJ =125°C
4
IF=100A
IF=50A
Qrr (μc)
IRRM (A)
IF=200A
60
3
IF=200A
40
2
20
1
0
0
400
600
1000
800
diF/dt(A/μs)
Figure3. Reverse Recovery Current vs diF/dt
200
0
IF=100A
IF=50A
0
200
400
600
800
1000
diF/dt(A/μs)
Figure4. Reverse Recovery Charge vs diF/dt
MIMMF200N070DA
MIMMF200N070DK
1.2
1
1.0
10-1
ZthJC (K/W)
Kf
0.8
0.6
trr
0.4 IRRM
10-2
Duty
0.5
0.2
0.1
0.05
Single Pulse
10-3
0.2
0.0
Qrr
0
25
50
100 125 150
75
TJ (°C)
Figure5. Dynamic Parameters vs Junction Temperature
-4
10
-1
10-4
10-3
10-2
10
1
Rectangular Pulse Duration (seconds)
Figure6. Transient Thermal Impedance
Dimensions (mm)
Figure7. Package Outline
Similar pages