Teledyne CCR-39S64C-T Latching coaxial switch Datasheet

Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
PART NUMBER
DESCRIPTION
CCR-39S
Commercial Latching Multi-throw, DC-18GHz
CR-39S
Elite Latching Multi-throw, DC-22GHz
The CCR-39S/CR-39S is a broadband, multi-throw, electromechanical coaxial switch designed to switch
a microwave signal from a common input to any of 3, 4, 5, or 6 outputs. The characteristic impedance
is 50 Ohms. The switches are small using the popular connector spacing on a 1.062” dia. circle. Each
position has an individual actuator mechanism allowing random position selection. This also minimizes
switching time.
The CCR-39S/CR-39S comes with a latching actuator. The latching switch remains in the last position
selected when the switch is de-energized. STD dual command requires a reset pulse before a new selected
position. A separate reset circuit allows all positions to be set to an open position. User must provide both
reset (clear) and set (select new position) commands.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Commercial Model, CCR-39S
Elite Model, CR-39S
Form Factor
–40°C to 65°C
–55°C to 85°C
Multi-Throw,
break before make
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
Frequency Range
CCR-39S
CR-39S
DC–18 GHz
DC–22 GHz
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Characteristic Impedance
50 Ohms
Operate Time
20 ms (max.)
Standard Actuator Life
Actuator Life w/ Additional Features
5,000,000 cycles
1,000,000 cycles
Connector Type
SMA
Humidity (Moisture Seal)
Available
Weight
6 oz. (170.1g) (max.)
Actuation Voltage Available
12
Actuation Current
15
24
255 205 130
Reset Current (# of Positions)
28 V
90 mA
3
765 615 390 270 mA
4
1020 820 520 360 mA
5
1275 1025 650 450 mA
6
1530 1230 780 540 mA
PERFORMANCE CHARACTERISTICS
Frequency
DC–4 GHz
4–8 GHz
8–12 GHz
12–16 GHz
16-20 GHz
20-22 GHz
0.1
0.2
0.2
0.3
0.3
0.4
Insertion Loss, dB,
max.
Isolation, dB, min.
VSWR , max.
80
80
80
80
75
70
1.05:1
1.1:1
1.2:1
1.2:1
1.2:1
1.2:1
PART NUMBERING SYSTEM
CCR-39
S
6
6
C
-
T **
Series
Options
Connectors
Actuator Type
Actuator Voltage
Number of Positions
CONNECTOR
ACTUATOR VOLTAGE
NUMBER OF POSITIONS
ACTUATOR TYPE
OPTIONS
S: SMA FEMALE
6: 28 VDC LATCHING
3: SP3T
0: NO INDICATOR CONTACTS
T: TTL DRIVERS WITH DIODES
7: 15 VDC LATCHING
4: SP4T
C: INDICATOR CONTACTS
D: COIL TRANSIENT SUPPRESSION DIODES
8: 12 VDC LATCHING
5: SP5T
R: POSITIVE
9: 24 VDC LATCHING
6: SP6T
TD: DECODERS AND TTL DRIVERS WITH
+ COMMON
DIODES
**SEE PARTS LIST ON PAGE
11-13
M: MOISTURE SEAL
S: D-SUB CONNECTOR*
For additional options, please contact factory.
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
* D-Sub Connector may be 9 or 15 pin depending on
number of throws. (See Connector Pinout page)
CCR-39S/CR-39S Page 1
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
SCHEMATICS AND MECHANICAL OUTLINE
Analog
TTL
Indicators
14X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
SP3T
SP5T
SP6T
SP4T
H = 2.25 STD & Indicator Model
H = 2.50 All OTHER Models
“-S OPTION” 9-PIN D-SUB OR 15-PIN D-MICRO CONNECTOR (EXAMPLE:
CCR-39S/CR-39S Page 2
CCR-39S660-S)
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
CONNECTOR PINOUT FOR LATCHING SP3T MULTI-THROW SWITCHES
EXAMPLE
CR-39S630-S
CR-39S63C-S
INDICATOR
TTL
DECODERS & TTL
PIN NO.
CR-39S630-TS
CR-39S63C-TS
YES
YES
YES
YES
CR-39S630-TDS
CR-39S63C-TDS
YES
1
YES
YES
9-PIN
9-PIN
9-PIN
15-PIN
9-PIN
9-PIN
1
PORT 1
PORT 1
TTL 1
TTL 1
LOGIC 1
LOGIC 1
2
PORT 2
PORT 3
PORT 2
PORT 3
TTL 2
TTL 3
TTL 2
TTL 3
LOGIC 2
LOGIC 3
LOGIC 2
LOGIC 3
3
4
5
E INDICATOR
F INDICATOR
6
7
8
9
10
G INDICATOR
COMMON
RESET
COMMON
RESET
COMMON
RESET
COMMON
COMMON
D INDICATOR (COM)
D INDICATOR (COM)
VSW
VSW
VSW
VSW
N/A
N/A
CR-39S640-TDS
CR-39S64C-TDS
YES
1
9
D INDICATOR (COM)
11
12
13
9-PIN D-SUB CONNECTOR
E INDICATOR
F INDICATOR
G INDICATOR
COMMON
RESET
6
E INDICATOR
N/A
N/A
N/A
F INDICATOR
G INDICATOR
15-PIN D-SUB CONNECTOR
14
15
CONNECTOR PINOUT FOR LATCHING SP4T MULTI-THROW SWITCHES
EXAMPLE
INDICATOR
TTL
DECODERS & TTL
CR-39S640-S
CR-39S64C-S
YES
CR-39S640-TS
CR-39S64C-TS
YES
YES
YES
YES
YES
PIN NO.
1
2
3
4
9-PIN
PORT 1
PORT 2
PORT 3
PORT 4
15-PIN
PORT 1
PORT 2
PORT 3
PORT 4
9-PIN
TTL 1
TTL 2
TTL 3
TTL 4
15-PIN
TTL 1
TTL 2
TTL 3
TTL 4
9-PIN
LOGIC 1
LOGIC 2
LOGIC 3
9-PIN
LOGIC 1
LOGIC 2
LOGIC 3
5
6
7
COMMON
COMMON
RESET
COMMON
RESET
COMMON
RESET
COMMON
RESET
COMMON
8
VSW
VSW
VSW
VSW
D INDICATOR (COM)
E INDICATOR
F INDICATOR
9
10
11
12
13
14
15
N/A
D INDICATOR (COM)
E INDICATOR
F INDICATOR
G INDICATOR
H INDICATOR
N/A
D INDICATOR (COM)
E INDICATOR
F INDICATOR
G INDICATOR
H INDICATOR
N/A
G INDICATOR
H INDICATOR
CONNECTOR PINOUT FOR LATCHING SP5T MULTI-THROW SWITCHES
EXAMPLE
CR-39S650-S
CR-39S65C-S
TTL
DECODERS & TTL
PIN NO.
1
2
CR-39S650-TS
CR-39S65C-TS
YES
YES
YES
15-PIN
PORT 1
9-PIN
TTL 1
15-PIN
TTL 1
PORT 2
PORT 3
PORT 4
PORT 5
TTL 2
TTL 3
TTL 4
TTL 5
COMMON
RESET
YES
INDICATOR
9-PIN
PORT 1
PORT 2
3
4
5
6
PORT 3
PORT 4
PORT 5
7
COMMON
8
9
10
11
12
13
14
15
RESET
N/A
D INDICATOR (COM)
E INDICATOR
F INDICATOR
G INDICATOR
H INDICATOR
K INDICATOR
CR-39S650-TDS
CR-39S65C-TDS
YES
YES
9-PIN
LOGIC 1
YES
15-PIN
LOGIC 1
TTL 2
TTL 3
TTL 4
TTL 5
LOGIC 2
LOGIC 3
LOGIC 2
LOGIC 3
COMMON
RESET
COMMON
RESET
COMMON
COMMON
VSW
VSW
D INDICATOR (COM)
E INDICATOR
F INDICATOR
G INDICATOR
H INDICATOR
K INDICATOR
VSW
VSW
D INDICATOR (COM)
E INDICATOR
F INDICATOR
G INDICATOR
H INDICATOR
K INDICATOR
N/A
N/A
CONNECTOR PINOUT FOR LATCHING SP6T MULTI-THROW SWITCHES
EXAMPLE
INDICATOR
TTL
DECODERS & TTL
PIN NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
CR-39S660-S
CR-39S66C-S
YES
CR-39S660-TS
CR-39S66C-TS
CR-39S660-TDS
CR-39S66C-TDS
YES
YES
9-PIN
PORT 1
PORT 2
PORT 3
15-PIN
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
COMMON
PORT 4
PORT 5
PORT 6
COMMON
RESET
RESET
N/A
D INDICATOR (COM)
E INDICATOR
F INDICATOR
G INDICATOR
H INDICATOR
K INDICATOR
L INDICATOR
© 2013 TELEDYNE RELAYS
9-PIN
TTL 1
TTL 2
TTL 3
TTL 4
TTL 5
TTL 6
COMMON
RESET
VSW
N/A
YES
9-PIN
LOGIC 1
LOGIC 2
LOGIC 3
YES
15-PIN
LOGIC 1
LOGIC 2
LOGIC 3
COMMON
COMMON
VSW
D INDICATOR (COM)
E INDICATOR
F INDICATOR
G INDICATOR
H INDICATOR
K INDICATOR
L INDICATOR
CONFIGURATION
NOT AVAILABLE
CONTACT FACTORY
VSW
N/A
(800) 284-7007 • www.teledynecoax.com
CCR-39S/CR-39S Page 3
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
TRUTH TABLE Latching
CCR-39SX3C-T
Logic
Input
RF Path
1
2
3
R
1
0
0
0
1
0
0
0
1
Indicator
Switches
J1
J2
J3
Reset
E
0
On
Off
0
Off
On
0
Off
Off
On
F
G
Off
Off
Off
Off
C
0
0
0
C
0
Off
0
0
C
TRUTH TABLE Latching
CCR-39SX3C-TD
Logic
Input
RF Path
Indicator
Switches
1
2
3
J1
J2
J3
Reset
E
F
G
0
0
0
On
Off
Off
Off
C
0
0
1
0
0
Off
On
Off
Off
0
C
0
0
1
0
Off
Off
On
Off
0
0
C
0
1
1
Off
Off
Off
Reset
0
0
0
1
1
1
0
0
0
COIL OFF
TRUTH TABLE Latching
CCR-39SX4C-T
Logic Input
1
2
RF Path
3
4
R
J1
J2
J3
Indicator
Switches
J4
Reset
E
F
G
H
1
0
0
0
0
On
Off
Off
Off
Off
C
0
0
0
0
1
0
0
0
Off
On
Off
Off
Off
0
C
0
0
0
0
1
0
0
Off
Off
On
Off
Off
0
0
C
0
0
0
0
1
0
Off
Off
Off
On
Off
0
0
0
C
TRUTH TABLE Latching
CCR-39SX4C-TD
Logic Input
RF Path
Indicator
Switches
1
2
3
J1
J2
J3
J4
Reset
E
F
G
H
0
0
0
On
Off
Off
Off
Off
C
0
0
0
1
0
0
Off
On
Off
Off
Off
0
C
0
0
0
1
0
Off
Off
On
Off
Off
0
0
C
0
1
1
0
Off
Off
Off
On
Off
0
0
0
C
0
1
1
Off
Off
Off
Off
Reset
1
1
1
CCR-39S/CR-39S Page 4
COIL OFF
0
0
0
0
0
0
0
0
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
TRUTH TABLE Latching
CCR-39SX5C-T
Logic Input
RF Path
Indicator Switches
1
2
3
4
5
R
J1
J2
J3
J4
J5
Reset
E
F
G
H
K
1
0
0
0
0
0
On
Off
Off
Off
Off
Off
C
0
0
0
0
0
1
0
0
0
0
Off
On
Off
Off
Off
Off
0
C
0
0
0
0
0
1
0
0
0
Off
Off
On
Off
Off
Off
0
0
C
0
0
0
0
0
1
0
0
Off
Off
Off
On
Off
Off
0
0
0
C
0
0
0
0
0
1
0
Off
Off
Off
Off
On
Off
0
0
0
0
C
TRUTH TABLE Latching
CCR-39SX5C-TD
Logic Input
RF Path
Indicator Switches
1
2
3
J1
J2
J3
J4
J5
Reset
E
F
G
H
K
0
0
0
On
Off
Off
Off
Off
Off
C
0
0
0
0
1
0
0
Off
On
Off
Off
Off
Off
0
C
0
0
0
0
1
0
Off
Off
On
Off
Off
Off
0
0
C
0
0
1
1
0
Off
Off
Off
On
Off
Off
0
0
0
C
0
0
0
1
Off
Off
Off
Off
On
Off
0
0
0
0
C
0
1
1
Off
Off
Off
Off
Off
Reset
1
1
1
COIL OFF
0
0
0
0
0
0
0
0
0
0
TRUTH TABLE Latching
CCR-39SX6C-T
Logic Input
1
2
RF Path
3
4
5
6
R
J1
J2
J3
Indicator Switches
J4
J5
J6
Reset
E
F
G
H
K
L
1
0
0
0
0
0
0
On
Off
Off
Off
Off
Off
Off
C
0
0
0
0
0
0
1
0
0
0
0
0
Off
On
Off
Off
Off
Off
Off
0
C
0
0
0
0
0
0
1
0
0
0
0
Off
Off
On
Off
Off
Off
Off
0
0
C
0
0
0
0
0
0
1
0
0
0
Off
Off
Off
On
Off
Off
Off
0
0
0
C
0
0
0
0
0
0
1
0
0
Off
Off
Off
Off
On
Off
Off
0
0
0
0
C
0
0
0
0
0
0
1
0
Off
Off
Off
Off
Off
On
Off
0
0
0
0
0
C
TRUTH TABLE Latching
CCR-39SX6C-TD
Logic Input
RF Path
Indicator Switches
1
2
3
J1
J2
J3
J4
J5
J6
Reset
E
F
G
H
K
L
0
0
0
On
Off
Off
Off
Off
Off
Off
C
0
0
0
0
0
1
0
0
Off
On
Off
Off
Off
Off
Off
0
C
0
0
0
0
0
1
0
Off
Off
On
Off
Off
Off
Off
0
0
C
0
0
0
1
1
0
Off
Off
Off
On
Off
Off
Off
0
0
0
C
0
0
0
0
1
Off
Off
Off
Off
On
Off
Off
0
0
0
0
C
0
1
0
1
Off
Off
Off
Off
Off
On
Off
0
0
0
0
0
C
0
1
1
Off
Off
Off
Off
Off
Off
Reset
1
1
1
© 2013 TELEDYNE RELAYS
COIL OFF
0
0
0
0
0
0
0
0
0
0
0
0
(800) 284-7007 • www.teledynecoax.com
CCR-39S/CR-39S Page 5
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
Insertion Loss ( 4-8 GHz )
0
0
-0.1
-0.1
Insertion Loss (dB)
Insertion Loss (dB)
Insertion Loss ( DC-4 GHz )
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1
-1
0
1
2
3
4
4
5
Frequency (GHz)
Insertion Loss ( 8-12 GHz )
7
8
15
16
Insertion Loss ( 12-16 GHz )
0
0
-0.1
-0.1
-0.2
-0.2
Insertion Loss (dB)
Insertion Loss (dB)
6
Frequency (GHz)
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1
-1
8
9
10
11
12
12
13
Frequency (GHz)
14
Frequency (GHz)
Insertion Loss ( 16-20 GHz )
Insertion Loss ( 20-22 GHz )
0
0
-0.1
-0.2
-0.2
-0.3
Insertion Loss (dB)
Insertion Loss(dB)
-0.1
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1
16
17
18
19
Frequency (GHz)
20
-1
20
20.5
21
21.5
22
Frequency (GHz)
18GHZ+ ELITE MODEL ONLY
RF NOTES
CCR-39S/CR-39S Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
Isolation ( 4-8 GHz )
0
0
-20
-20
-40
-40
Isolation (dB)
Isolation (dB)
Isolation ( DC-4 GHz )
-60
-80
-100
-120
-60
-80
-100
-120
-140
-140
0
1
2
3
4
4
5
Frequency (GHz)
Isolation ( 8-12 GHz )
7
8
15
16
Isolation ( 12-16 GHz )
0
0
-20
-20
-40
-40
Isolation (dB)
Isolation (dB)
6
Frequency (GHz)
-60
-80
-100
-120
-60
-80
-100
-120
-140
-140
8
9
10
11
12
12
13
Frequency (GHz)
14
Frequency (GHz)
Isolation ( 16-20 GHz )
Isolation ( 20-22 GHz )
0
0
-20
-40
Isolation (dB)
Isolation (dB)
-20
-60
-80
-100
-40
-60
-80
-100
-120
-120
-140
16
17
18
Frequency (GHz)
19
20
-140
20
20.5
21
21.5
22
Frequency (GHz)
18GHZ+ ELITE MODEL ONLY
RF NOTES
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-39S/CR-39S Page 7
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
VSWR ( 4-8 GHz )
2
2
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
VSWR ( DC-4 GHz )
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
1
0
1
2
3
4
4
5
6
Frequency (GHz)
VSWR ( 8-12 GHz )
8
15
16
VSWR ( 12-16 GHz )
2
2
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
7
Frequency (GHz)
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
1
8
9
10
11
12
12
13
14
Frequency (GHz)
Frequency (GHz)
VSWR ( 16-20 GHz )
VSWR ( 20-22 GHz )
2
2
1.9
1.9
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
1.8
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
16
17
18
19
Frequency (GHz)
RF NOTES
CCR-39S/CR-39S Page 8
20
1
20
20.5
18GHZ+ ELITE MODEL ONLY
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
21
21.5
22
Frequency (GHz)
© 2013 TELEDYNE COAX SWITCHES
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
Power (W)
1000
800
600
400 STAN
DAR
DS
300
MA
200
SW
ITC
HES
100
80
60
40
30
20
10
.1
.2
.3 .4 .6 .8 1
2
4
6 8 10
18
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-39S/CR-39S Page 9
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
GLOSSARY
Actuator
An actuator is the electromechanical mechanism that transfers the
RF contacts from one position to another upon DC command.
Arc Suppression Diode
A diode is connected in parallel with the coil. This diode limits the
“reverse EMF spike” generated when the coil de-energizes to 0.7
volts. The diode cathode is connected to the positive side of the
coil and the anode is connected to the negative side.
Date Code
All switches are marked with either a unique serial number or a
date code. Date codes are in accordance with MIL-STD-1285
Paragraph 5.2.5 and consist of four digits. The first two digits
define the year and the last two digits define the week of the year
(YYWW). Thus, 1032 identifies switches that passed through final
inspection during the 32nd week of 2010.
Indicator
Indicators tell the system which position the switch is in. Other
names for indicators are telemetry contacts or tellback circuit.
Indicators are usually a set of internally mounted DC contacts linked
to the actuator. They can be wired to digital input lines, status lights,
or interlocks. Unless otherwise specified, the maximum indicator
contact rating is 30 Vdc, 50 mA, or 1.5 Watts into a resistive load.
Isolation
Isolation is the measure of the power level at the output connector
of an unconnected RF channel as referenced to the power at the
input connector. It is specified in dB below the input power level.
Multi-Throw Latching Switch
A multi-throw switch is a switch with one input and three or more
output ports. The CCR-39 can switch a microwave signal to any of
2,3,4,5 or 6 output from a single common input.
Switching Time
Switching time is the total interval beginning with the arrival of the
leading edge of the command pulse at the switch DC input and
ending with the completion of the switch transfer, including contact
bounce. It consists of three parts: (1) inductive delay in the coil, (2)
transfer time of the physical movement of the contacts, and (3) the
bounce time of the RF contacts.
TTL Switch Driver Option
As a special option, switch drivers can be provided for both failsafe
and latching switches, which are compatible with industry-standard
low-power Schottky TTL circuits.
TD-Option
This option includes a decoder. The 3-bit parallel command is
decoded to internally select the appropriate position. See the logic
tables. The TD-Option increases the Vsw supply current demand
by 50mA max at 28Vdc and +20°C.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches is
frequency dependent. With increasing frequency, VSWR and
insertion loss increase while isolation decreases. All data sheets
specify these three parameters as “worst case” at the highest
operating frequency. If the switch is to be used over a narrow
frequency band, better performance can be achieved.
Actuator Current vs Temperature
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
operating temperature of the switch and the actuator drive current.
For switches operating at 28 VDC, the approximate actuator drive
current at temperature, T, can be calculated using the equation:
IT =
DUAL PULSE SWITCHING COMMAND CHARACTERISTICS:
1. APPLIES FOR SINGLE-POLE MULTI-THROW LATCHING
SWITCH ONLY.
2. MUST APPLY RESET PULSE FIRST
(BREAK-BEFORE-MAKE).
3. RESET AND SET DEFINITIONS
RESET: OPEN ALL RF PATHS (POSITIONS).
SET: CLOSE THE SELECTED RF PATH (POSITION).
4. COMMAND PULSE TIMING:
RESET
PULSE
IT = Actuator current at temperature, T
IA = Room temperature actuator current –
see data sheet
T = Temperature of interest in °C
V
VOLTAGE PULSE
(SEE NOTE 5)
O
T1
T3
T2
T1 AND T2 = 30 mSEC
MIN. T3 = 10 mSEC MIN.
I2 CURRENT PULSE
(SEE NOTE 6)
ON
SWITCHING TIME
(MONITOR RF
CONTACT): T4
AND T5 = 20
mSEC MAX
OFF
T4
T5
5. COMMAND SWITCHING VOLTAGE:
V = 26-32 VDC PULSE
6. SWITCHING CURRENT:
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous materials
and external magnetic fields. Neighboring ferrous materials should
be permitted no closer than 0.5 inches and adjacent external
magnetic fields should be limited to a flux density of less than 5
Gauss.
SPECIAL FEATURE
Switching High-Power or Highly Sensitive Signals
Ensure the most linear response with the best galvanically
matched contact system in the industry. Extremely low
passive intermodulation is standard on all of our switches.
Carrier
Frequency 1
Carrier
Frequency 2
PIM 3rd Order
Frequency
PIM 5th Order
Frequency
870 MHz
893 MHz
847 MHz
824 MHz
SWITCHING CURRENT
AT 28 VDC AND 20°C
NO. OF POS.
3 POS.
4 POS.
5 POS.
6 POS.
CCR-39S/CR-39S Page 10
RESET (I 1)
270 mA
360 mA
450 mA
540 mA
SET (12)
90 mA
90 mA
90 mA
90 mA
[1 + .00385 (T-20)]
Where:
SET
PULSE
I1
IA
Multiple
Positions
3rd Order
Intermodulation
5th Order
Intermodulation
–96 dBm
–115 dBm
–139 dBc
–158 dBc
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
LATCHING CCR-39S/CR-39S PART NUMBER LIST
PART NO.
*
PART NO.
PART NO.
PART NO.
1
CCR-39SX3C
43
CCR-39SX30-TMS
85
CCR-39SX40-TDS
127
CCR-39SX50-TDM
2
CCR-39SX3C-D
44
CCR-39SX30-TS
86
CCR-39SX40-TM
128
CCR-39SX50-TDMS
3
CCR-39SX3C-DM
45
CCR-39SX4C
87
CCR-39SX40-TMS
129
CCR-39SX50-TDS
4
CCR-39SX3C-DR
46
CCR-39SX4C-D
88
CCR-39SX40-TS
130
CCR-39SX50-TM
5
CCR-39SX3C-DRM
47
CCR-39SX4C-DM
89
CCR-39SX5C
131
CCR-39SX50-TMS
6
CCR-39SX3C-DRS
48
CCR-39SX4C-DR
90
CCR-39SX5C-D
132
CCR-39SX50-TS
7
CCR-39SX3C-DS
49
CCR-39SX4C-DRM
91
CCR-39SX5C-DM
133
CCR-39SX6C
8
CCR-39SX3C-M
50
CCR-39SX4C-DRS
92
CCR-39SX5C-DR
134
CCR-39SX6C-D
9
CCR-39SX3C-MS
51
CCR-39SX4C-DS
93
CCR-39SX5C-DRM
135
CCR-39SX6C-DM
10
CCR-39SX3C-R
52
CCR-39SX4C-M
94
CCR-39SX5C-DRS
136
CCR-39SX6C-DR
11
CCR-39SX3C-RM
53
CCR-39SX4C-MS
95
CCR-39SX5C-DS
137
CCR-39SX6C-DRM
12
CCR-39SX3C-RMS
54
CCR-39SX4C-R
96
CCR-39SX5C-M
138
CCR-39SX6C-DRS
13
CCR-39SX3C-RS
55
CCR-39SX4C-RM
97
CCR-39SX5C-MS
139
CCR-39SX6C-DS
14
CCR-39SX3C-S
56
CCR-39SX4C-RMS
98
CCR-39SX5C-R
140
CCR-39SX6C-M
15
CCR-39SX3C-T
57
CCR-39SX4C-RS
99
CCR-39SX5C-RM
141
CCR-39SX6C-MS
16
CCR-39SX3C-TD
58
CCR-39SX4C-S
100
CCR-39SX5C-RMS
142
CCR-39SX6C-R
17
CCR-39SX3C-TDM
39
CCR-39SX4C-T
101
CCR-39SX5C-RS
143
CCR-39SX6C-RM
18
CCR-39SX3C-TDMS
60
CCR-39SX4C-TD
102
CCR-39SX5C-S
144
CCR-39SX6C-RMS
19
CCR-39SX3C-TDS
61
CCR-39SX4C-TDM
103
CCR-39SX5C-T
145
CCR-39SX6C-RS
20
CCR-39SX3C-TM
62
CCR-39SX4C-TDMS
104
CCR-39SX5C-TD
146
CCR-39SX6C-S
21
CCR-39SX3C-TMS
63
CCR-39SX4C-TDS
105
CCR-39SX5C-TDM
147
CCR-39SX6C-T
22
CCR-39SX3C-TS
64
CCR-39SX4C-TM
106
CCR-39SX5C-TDMS
148
CCR-39SX6C-TD
23
CCR-39SX30
65
CCR-39SX4C-TMS
107
CCR-39SX5C-TDS
149
CCR-39SX6C-TDM
24
CCR-39SX30-D
66
CCR-39SX4C-TS
108
CCR-39SX5C-TM
150
CCR-39SX6C-TDMS
25
CCR-39SX30-DM
67
CCR-39SX40
109
CCR-39SX5C-TMS
151
CCR-39SX6C-TDS
26
CCR-39SX30-DR
68
CCR-39SX40-D
110
CCR-39SX5C-TS
152
CCR-39SX6C-TM
27
CCR-39SX30-DRM
69
CCR-39SX40-DM
111
CCR-39SX50
153
CCR-39SX6C-TMS
28
CCR-39SX30-DRS
70
CCR-39SX40-DR
112
CCR-39SX50-D
154
CCR-39SX6C-TS
29
CCR-39SX30-DS
71
CCR-39SX40-DRM
113
CCR-39SX50-DM
155
CCR-39SX60
30
CCR-39SX30-M
72
CCR-39SX40-DRS
114
CCR-39SX50-DR
156
CCR-39SX60-D
31
CCR-39SX30-MS
73
CCR-39SX40-DS
115
CCR-39SX50-DRM
157
CCR-39SX60-DM
32
CCR-39SX30-R
74
CCR-39SX40-M
116
CCR-39SX50-DRS
158
CCR-39SX60-DR
33
CCR-39SX30-RM
75
CCR-39SX40-MS
117
CCR-39SX50-DS
139
CCR-39SX60-DRM
34
CCR-39SX30-RMS
76
CCR-39SX40-R
118
CCR-39SX50-M
160
CCR-39SX60-DRS
35
CCR-39SX30-RS
77
CCR-39SX40-RM
119
CCR-39SX50-MS
161
CCR-39SX60-DS
36
CCR-39SX30-S
78
CCR-39SX40-RMS
120
CCR-39SX50-R
162
CCR-39SX60-M
37
CCR-39SX30-T
79
CCR-39SX40-RS
121
CCR-39SX50-RM
163
CCR-39SX60-MS
38
CCR-39SX30-TD
80
CCR-39SX40-S
122
CCR-39SX50-RMS
164
CCR-39SX60-R
39
CCR-39SX30-TDM
81
CCR-39SX40-T
123
CCR-39SX50-RS
165
CCR-39SX60-RM
40
CCR-39SX30-TDMS
82
CCR-39SX40-TD
124
CCR-39SX50-S
166
CCR-39SX60-RMS
41
CCR-39SX30-TDS
83
CCR-39SX40-TDM
125
CCR-39SX50-T
167
CCR-39SX60-RS
42
CCR-39SX30-TM
84
CCR-39SX40-TDMS
126
CCR-39SX50-TD
168
CCR-39SX60-S
X = 6 (28Vdc), 7 (15Vdc), 8 (12Vdc) and 9 (24Vdc)
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-39S/CR-39S Page 11
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
LATCHING CCR-39S/CR-39S PART NUMBER LIST
PART NO.
*
PART NO.
PART NO.
PART NO.
169
CCR-39SX60-T
211
CR-39SX30-RS
253
CR-39SX40-RM
295
CR-39SX50-MS
170
CCR-39SX60-TD
212
CR-39SX30-S
254
CR-39SX40-RMS
296
CR-39SX50-R
171
CCR-39SX60-TDM
213
CR-39SX30-T
255
CR-39SX40-RS
297
CR-39SX50-RM
172
CCR-39SX60-TDMS
214
CR-39SX30-TD
256
CR-39SX40-S
298
CR-39SX50-RMS
173
CCR-39SX60-TDS
215
CR-39SX30-TDM
257
CR-39SX40-T
299
CR-39SX50-RS
174
CCR-39SX60-TM
216
CR-39SX30-TDMS
258
CR-39SX40-TD
300
CR-39SX50-S
175
CCR-39SX60-TMS
217
CR-39SX30-TDS
239
CR-39SX40-TDM
301
CR-39SX50-T
176
CCR-39SX60-TS
218
CR-39SX30-TM
260
CR-39SX40-TDMS
302
CR-39SX50-TD
177
CR-39SX3C
219
CR-39SX30-TMS
261
CR-39SX40-TDS
303
CR-39SX50-TDM
178
CR-39SX3C-D
220
CR-39SX30-TS
262
CR-39SX40-TM
304
CR-39SX50-TDMS
179
CR-39SX3C-DM
221
CR-39SX4C
263
CR-39SX40-TMS
305
CR-39SX50-TDS
180
CR-39SX3C-DR
222
CR-39SX4C-D
264
CR-39SX40-TS
306
CR-39SX50-TM
181
CR-39SX3C-DRM
223
CR-39SX4C-DM
265
CR-39SX5C
307
CR-39SX50-TMS
182
CR-39SX3C-DRS
224
CR-39SX4C-DR
266
CR-39SX5C-D
308
CR-39SX50-TS
183
CR-39SX3C-DS
225
CR-39SX4C-DRM
267
CR-39SX5C-DM
309
CR-39SX6C
184
CR-39SX3C-M
226
CR-39SX4C-DRS
268
CR-39SX5C-DR
310
CR-39SX6C-D
185
CR-39SX3C-MS
227
CR-39SX4C-DS
269
CR-39SX5C-DRM
311
CR-39SX6C-DM
186
CR-39SX3C-R
228
CR-39SX4C-M
270
CR-39SX5C-DRS
312
CR-39SX6C-DR
187
CR-39SX3C-RM
229
CR-39SX4C-MS
271
CR-39SX5C-DS
313
CR-39SX6C-DRM
188
CR-39SX3C-RMS
230
CR-39SX4C-R
272
CR-39SX5C-M
314
CR-39SX6C-DRS
189
CR-39SX3C-RS
231
CR-39SX4C-RM
273
CR-39SX5C-MS
315
CR-39SX6C-DS
190
CR-39SX3C-S
232
CR-39SX4C-RMS
274
CR-39SX5C-R
316
CR-39SX6C-M
191
CR-39SX3C-T
233
CR-39SX4C-RS
275
CR-39SX5C-RM
317
CR-39SX6C-MS
192
CR-39SX3C-TD
234
CR-39SX4C-S
276
CR-39SX5C-RMS
318
CR-39SX6C-R
193
CR-39SX3C-TDM
235
CR-39SX4C-T
277
CR-39SX5C-RS
319
CR-39SX6C-RM
194
CR-39SX3C-TDMS
236
CR-39SX4C-TD
278
CR-39SX5C-S
320
CR-39SX6C-RMS
195
CR-39SX3C-TDS
237
CR-39SX4C-TDM
279
CR-39SX5C-T
321
CR-39SX6C-RS
196
CR-39SX3C-TM
238
CR-39SX4C-TDMS
280
CR-39SX5C-TD
322
CR-39SX6C-S
197
CR-39SX3C-TMS
239
CR-39SX4C-TDS
281
CR-39SX5C-TDM
323
CR-39SX6C-T
198
CR-39SX3C-TS
240
CR-39SX4C-TM
282
CR-39SX5C-TDMS
324
CR-39SX6C-TD
199
CR-39SX30
241
CR-39SX4C-TMS
283
CR-39SX5C-TDS
325
CR-39SX6C-TDM
200
CR-39SX30-D
242
CR-39SX4C-TS
284
CR-39SX5C-TM
326
CR-39SX6C-TDMS
201
CR-39SX30-DM
243
CR-39SX40
285
CR-39SX5C-TMS
327
CR-39SX6C-TDS
202
CR-39SX30-DR
244
CR-39SX40-D
286
CR-39SX5C-TS
328
CR-39SX6C-TM
203
CR-39SX30-DRM
245
CR-39SX40-DM
287
CR-39SX50
329
CR-39SX6C-TMS
204
CR-39SX30-DRS
246
CR-39SX40-DR
288
CR-39SX50-D
330
CR-39SX6C-TS
205
CR-39SX30-DS
247
CR-39SX40-DRM
289
CR-39SX50-DM
331
CR-39SX60
206
CR-39SX30-M
248
CR-39SX40-DRS
290
CR-39SX50-DR
332
CR-39SX60-D
207
CR-39SX30-MS
249
CR-39SX40-DS
291
CR-39SX50-DRM
333
CR-39SX60-DM
208
CR-39SX30-R
250
CR-39SX40-M
292
CR-39SX50-DRS
334
CR-39SX60-DR
209
CR-39SX30-RM
251
CR-39SX40-MS
293
CR-39SX50-DS
335
CR-39SX60-DRM
210
CR-39SX30-RMS
252
CR-39SX40-R
294
CR-39SX50-M
336
CR-39SX60-DRS
X = 6 (28Vdc), 7 (15Vdc), 8 (12Vdc) and 9 (24Vdc)
CCR-39S/CR-39S Page 12
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-39S\CR-39S\072013\Q3
Series CCR-39S/CR-39S
COAX SWITCHES
Multi-Throw DC-18 GHz/DC-22 GHz
Latching Coaxial Switch
LATCHING CCR-39S/CR-39S PART NUMBER LIST
PART NO.
*
337
CR-39SX60-DS
338
CR-39SX60-M
339
CR-39SX60-MS
340
CR-39SX60-R
341
CR-39SX60-RM
342
CR-39SX60-RMS
343
CR-39SX60-RS
344
CR-39SX60-S
345
CR-39SX60-T
346
CR-39SX60-TD
347
CR-39SX60-TDM
348
CR-39SX60-TDMS
349
CR-39SX60-TDS
350
CR-39SX60-TM
351
CR-39SX60-TMS
352
CR-39SX60-TS
X = 6 (28Vdc), 7 (15Vdc), 8 (12Vdc) and 9 (24Vdc)
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-39S/CR-39S Page 13
CCR-39S\CR-39S\072013\Q3
Similar pages