Minmax MGWI06-48D05 Dc/dc converter 6w, dip package Datasheet

®
MGWI06 SERIES
DC/DC CONVERTER 6W, DIP Package
FEATURES
►Industrial DIP-16 Package
►Ultra-wide 4:1 Input Voltage Range
►Fully Regulated Output Voltage
►I/O Isolation 1500 VDC
►Operating Ambient Temp. Range -40°C to +85°C
►Overload and Short Circuit Protection
►Remote On/Off Control
►Designed-in Conducted EMI meets EN55022 Class A & FCC Level A
►UL/cUL/IEC/EN 60950-1 Safety Approval
PRODUCT OVERVIEW
The MINMAX MGWI06 series is a new range of isolated 6W DC/DC converter modules featuring fully regulated output voltages and ultra-wide 4:1 input
voltage ranges. These products are with a very small footprint occupying just 4.5cm2 (0.7 square in.) on PCB. An excellent efficiency allows an operating
temperature range of –40° to +85°C. Further features include remote On/Off control and over load protection.
The very compact dimensions of these DC/DC converters make them an ideal solution for many space critical applications in battery-powered equipment
and instrumentation.
Model Selection Guide
Model
Input
Output
Output
Number
Voltage
Voltage
Current
(Range)
VDC
MGWI06-24S033
MGWI06-24S05
MGWI06-24S12
MGWI06-24S15
MGWI06-24S24
MGWI06-24D05
MGWI06-24D12
MGWI06-24D15
MGWI06-48S033
MGWI06-48S05
MGWI06-48S12
MGWI06-48S15
MGWI06-48S24
MGWI06-48D05
MGWI06-48D12
MGWI06-48D15
24
(9 ~ 36)
48
(18 ~ 75)
VDC
3.3
5
12
15
24
±5
±12
±15
3.3
5
12
15
24
±5
±12
±15
Input Current
Max. capacitive
Load
Max.
Min.
@Max. Load
@No Load
mA
1450
1200
500
400
250
±600
±250
±200
1450
1200
500
400
250
±600
±250
±200
mA
218
180
75
60
38
±90
±38
±30
218
180
75
60
38
±90
±38
±30
mA(typ.)
262
316
301
301
301
301
301
301
131
158
151
151
151
151
151
151
mA(typ.)
Efficiency
(typ.)
@Max. Load
μF
%
76
79
83
83
83
82
83
83
76
79
83
83
83
82
83
83
330
100
30
100#
330
100
20
100#
# For each output
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Under Voltage Shutdown
Model
Min.
Typ.
Max.
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
24V Input Models
---
---
9
48V Input Models
---
---
18
24V Input Models
---
---
8.5
48V Input Models
---
---
17
All Models
---
---
Input Filter
VDC
Internal Pi Type
Short Circuit Input Power
Conducted EMI
3000
mW
Compliance to EN 55022,class A and FCC part 15,class A
E-mail:[email protected]
2015/07/31 REV:10
Unit
Tel:886-6-2923150
Page 1 of 4
®
MGWI06 SERIES
DC/DC CONVERTER 6W, DIP Package
Remote On/Off Control
Parameter
Converter On
Converter Off
Control Input Current (on)
Control Input Current (off)
Control Common
Standby Input Current
Conditions
Vin-RC=5V
Vin-RC=0V
Min.
Typ.
2.5V ~ 50VDC or Open Circuit
-0.7V ~ 0.8V
--------Referenced to Negative Input
-----
Max.
Unit
500
-500
μA
μA
10
mA
Typ.
±1.0
±1.0
±0.5
Max.
±2.0
--±1.0
--±0.5
--60
--300
--±3
--±0.01
110
150
Continuous, Automatic Recovery
±1.2
100
600
--±0.02
---
Unit
%Vnom.
%
%
%
mV P-P
μsec
%
%/℃
%
Output Specifications
Parameter
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Conditions
Dual Output, Balanced Loads
Vin=Min. to Max. @Full Load
Io=15% to 100%
0-20 MHz Bandwidth
25% Load Step Change
Foldback
Min.
-------
General Specifications
Parameter
Conditions
60 Seconds
1 Seconds
500 VDC
100KHz, 1V
Typ.
Max.
------------1200
1500
330
--MIL-HDBK-217F@25℃, Ground Benign
350,000
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-report)
I/O Isolation Voltage
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Safety Approvals
Min.
1500
1800
1000
-----
Unit
VDC
VDC
MΩ
pF
KHz
Hours
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature
(1.5mm from case for 10Sec.)
Conditions
Natural Convection
2015/07/31 REV:10
Max.
+85
Unit
℃
---50
---
+105
+125
95
℃
℃
% rel. H
260
℃
Natural convection
---
Power Derating Curve
E-mail:[email protected]
Min.
-40
Tel:886-6-2923150
Page 2 of 4
®
MGWI06 SERIES
DC/DC CONVERTER 6W, DIP Package
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
4
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
5
We recommend to protect the converter by a slow blow fuse in the input supply line.
6
Other input and output voltage may be available, please contact factory.
7
Specifications are subject to change without notice.
however, they may not meet all specifications listed.
Package Specifications
4.1
[0.16]
0.50 [0.02]
2.54
[0.10]
10.2 [0.40]
Pin Connections
Pin
Single Output
0.5 [0.02]
Mechanical Dimensions
10.16 [0.40]
11
2
-Vin
-Vin
6
NC
Common
NC
-Vout
9
+Vout
+Vout
11
-Vout
Common
16
+Vin
+Vin
NC: No Connection
9
►All
5.08
[0.20]
21.6 [0.85]
12.7 [0.50]
1.9
[0.08]
Physical Characteristics
Case Size
:
Case Material
:
21.6x20.3x10.2 mm (0.85x0.8x0.4 inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Subplate
Weight
:
9.1g
E-mail:[email protected]
2015/07/31 REV:10
Tel:886-6-2923150
Page 3 of 4
Remote On/Off
8
8
Bottom View
16
Remote On/Off
20.3 [0.80]
6
15.22 [0.60]
1 2
Dual Output
1
dimensions in mm (inches)
►Tolerance: X.X±0.25
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
diameter  0.5 ±0.05 (0.02±0.002)
®
MGWI06 SERIES
DC/DC CONVERTER 6W, DIP Package
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Resistive
Load
Cout
Scope
Copper Strip
Technical Notes
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent.
A logic low is -0.7V to 0.8V. A logic high is 2.5V to 50V. The maximum sink current of the switch at on/off terminal during a logic low is -500 μA.
The maximum sink current of the switch at on/off terminal during a logic high is 500μA or open.
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 4.7μF for the 24V input devices and a 2.2μF for the 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3μF capacitors at the output.
+
+Vin
-
+Out
Single Output
DC / DC
Converter
DC Power
Source
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC
Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MGWI06 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2015/07/31
REV:10
Page 4 of 4