New Product Multifunction Counter/Tachometer H7CX-@-N Ultra-compact Counter Provides More Complete Functionality. Basic Features • Short body with depth of only 59 mm (for 12 to 24-VDC Models with Screw Terminals).*1 • Better readability with character height of 12 mm on 4-digit models and 10 mm on 6-digit models. • The present value display characters can be switched between red, green, and orange.*2 Safety and Reliability • New set value limit and counter functions have been added. Other Features • Front Panel can be changed to white or light gray.*3 • Models with two independent tachometer inputs have been added to the series. *1.For 100 to 240-VAC Models with Screw Terminals: 78 mm, Models with Sockets: 63.7 mm (case dimension). *2.The H7CX-A11 and H7CX-R11 have only red characters. *3.The Front Panel can be replaced with an optional Front Panel (except for Tachometer-only Models). Refer to Safety Precautions on page 52. Features Basic Features Safety and Reliability Ultra Short Body Isolated Power Supply and Input Circuits The body depth has been greatly reduced. Helps in making thinner control panels. Power supply circuit and input circuits are isolated inside the Counter/ Tachometer. Previous non-isolated counters had wiring restrictions and could be damaged if wired incorrectly. The H7CX removes these worries. Note: Except 12 to 24-VDC models. 12 to 24-VDC Models with Screw Terminals: 59 mm 100 to 240-VAC Models with Screw Terminals: 78 mm* Models with Sockets: 63.7 mm (case dimension) * Power supply circuit and input circuits are isolated for safety and reliability. Set Value Limit You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mistakes. New models Previous models Easier to Read For better readability, the character height for the present value display is 12 mm on models with 4 digits, the largest class in the industry. The wide viewing angle and brightness provide excellent visibility. The number of display segments has also been increased to make settings easier to understand, and the present value display can be switched between red, green, and orange so that output status can be seen from a distance. Model with 4 Digits Setting the upper limit of the set value enables worry-free operation. For 1,000 pieces No overflow Model with 6 Digits 12 mm (actual size) 10 mm (actual size) (Display example) New Previous models models Output Counter Easy to read from the top, bottom, and sides! The output counter counts the number of times the output turns ON (alarms can be displayed and the count can be monitored in increments of 1,000 operations). This counter is useful in managing the service life of the Counter/Tachometer or the load. Note: The display color can be switched on all models except for the H7CX-A11 and H7CX-R11. The Easiest Operation Operation is simplified by the Up/Down Key for each digit on 4-digit models and Up Key for each digit on 6-digit models. Model with 4 Digits Model with 6 Digits 1 H7CX-@-N Other Features Key Protection The front color can be changed simply by replacing the Front Panel. Select from any of seven protection patterns. Use the best one for the application. The Front Panel can be replaced with an optional Front Panel (sold separately) with a different color to match the installation site. Select from black, white, and light gray (except for models with tachometer function only). New Functions Black (Standard) Light gray White Only the Front Panel can be replaced. Universal NPN/PNP Input Many useful functions have been added, including a Twin Counter Mode and many tachometer functions to handle even more applications. New Tachometer Functions • Control with two independent inputs (independent measurements, differential, absolute ratio, and error ratio) • Peak/bottom hold function • Output hysteresis setting • Output OFF delay • Switching the measurement method (pulse cycle/pulse width) • Startup time • Auto-zero time • Averaging method/Number of averaging times • AMD-compatible Mode DC 2-wire sensors can be connected for a wide range of input devices. Waterproof, Dust-proof Structure (UL508 Type 4X and IP66) Worry-free application is possible in locations subject to water. Note: When the Y92S-29 Waterproof Packing is used. Model Number Structure Model Configuration H7CX Series H7CX-A-series Multifunction Preset Counter H7CX-R-series Digital Tachometer Model Classification Model Function Preset counter Preset counter/tachometer H7CX-A4W@-N H7CX-AW@-N/-AU@-N 1-stage preset counter Yes Yes Yes No 2-stage preset counter No Yes Yes No Total and preset counter Yes Yes Yes No Batch counter No Yes Yes No Dual counter No Yes Yes No Twin counter No Yes Yes No Tachometer No No Yes*1 Yes No Yes 1 input or 2 inputs (independent measurements, differential, absolute ratio value, and error ratio value) Tachometer input Settings External connections Display color of present value Display digits No 1-stage 11-pin socket Red 4 or 6 digits 2-stage Yes 1 input H7CX-R11W@-N Yes 2 inputs (independent measurement) only 11-pin socket Red, green, or orange 4 digits H7CX-R11@-N 1-stage Screw terminals Red 6 digits *1. Set the tachometer input mode from the function setting mode to switch to the tachometer function. 2 Tachometer H7CX-A@-N 6 digits H7CX-@-N Model Number Legend (Not all possible combinations of functions are available.) H7CX-@@@@@@-N 1 2 3 4 5 6 1. Type 2. External connections 3. Digits Symbol Meaning Symbol Meaning Symbol A Standard type None Screw terminals None 6 digits R Tachometer 11 11-pin socket 4 4 digits 4. Settings 5. Output type Symbol Meaning None 1-stage setting U Factory-set to 1-stage setting W Factory-set to 2-stage setting* Meaning 6. Supply voltage Symbol Meaning Symbol Meaning None Contact output or contact output + transistor output None 100 to 240 VAC at 50/60 Hz S Transistor output D 12 to 24 VDC D1 12 to 24 VDC/24 VAC at 50/60 Hz * The H7CX-R11W@ is a 1-stage (2 inputs and outputs) rather than a 2-stage Counter. Ordering Information List of Models Type Classification Configuration External connections Settings Display digits Power supply voltage Outputs Contact output (SPDT) Model H7CX-A114-N 100 to 240 VAC 4 digits Transistor output (SPST) Contact output (SPDT) 11-pin socket H7CX-A114S-N 12 to 24 VDC/24 VAC H7CX-A114D1-N Contact output (SPDT) H7CX-A11-N 100 to 240 VAC Transistor output (SPST) H7CX-A11S-N 6 digits Contact output (SPDT) H7CX-A11D1-N 12 to 24 VDC/24 VAC Transistor output (SPST) • 1-stage preset counter • Total and preset counter 1-stage H7CX-A11SD1-N Contact output (SPDT) H7CX-A4-N 100 to 240 VAC Transistor output (SPST) H7CX-A4S-N Contact output (SPDT) H7CX-A4D-N 4 digits 12 to 24 VDC Preset counter Transistor output (SPST) H7CX-A4SD-N Contact output (SPDT) H7CX-A-N 100 to 240 VAC Transistor output (SPST) H7CX-AS-N Contact output (SPDT) H7CX-AD-N 6 digits 12 to 24 VDC H7CX-A Series • 1-stage preset counter • 2-stage preset counter • Total and preset counter • Batch counter • Dual counter • Twin counter Transistor output (SPST) H7CX-ASD-N Contact output (SPST + SPDT) 100 to 240 VAC H7CX-A4W-N Transistor output (DPST) H7CX-A4WSD-N 4 digits Screw terminals 12 to 24 VDC Contact output (SPST + SPDT) H7CX-AW-N 100 to 240 VAC Preset counter/ Tachometer 2-stage • 1-stage preset counter • 2-stage preset counter • Total and preset counter • Batch counter • Dual counter • Twin counter • Tachometer Transistor output (DPST) H7CX-AWS-N Contact output (SPST + SPDT) H7CX-AWD1-N 12 to 24 VDC/24 VAC H7CX-AWSD1-N Transistor output (DPST) 6 digits Contact output (SPDT) + Transistor output (SPST) Contact output (SPDT) + Transistor output (SPST) 12 to 24 VDC H7CX-AWSD-N 100 to 240 VAC H7CX-AU-N H7CX-AUD1-N 12 to 24 VDC/24 VAC Transistor output (DPST) H7CX-R Series Tachometer • Tachometer 11-pin socket 1-stage (1 input and output) 1-stage (2 inputs and outputs) H7CX-AUSD1-N 100 to 240 VAC H7CX-R11-N Contact output (SPDT) 12 to 24 VDC/24 VAC H7CX-R11D1-N 6 digits 100 to 240 VAC H7CX-R11W-N Contact output (SPDT + SPST) 12 to 24 VDC/24 VAC H7CX-R11WD1-N Note: 1. The functions that are provided depend on the model. Check detailed specifications before ordering. 2. Refer to page page 37 and later for information on H7CX-R Tachometers. 3 H7CX-@-N Accessories (Order Separately) Front Panels (Replacement Part) Model Color Y92P-CXC4G Light gray (5Y7/1) Y92P-CXC4S White (5Y9.2/0.5) Y92P-CXC4B Black (N1.5) Y92P-CXC6G Light gray (5Y7/1) Y92P-CXC6S White (5Y9.2/0.5) Y92P-CXC6B Black (N1.5) Applicable Counters Page 4-digit Counter 12 6-digit Counter Note: 1. You can change the color of the Front Panel when mounting the Counter. The Counter is shipped with a black (N1.5) Front Panel. 2. "COUNTER" is printed on the front of Replacement Front Panels. Soft Cover Model Y92A-48F1 Remarks --- Page 12 Hard Cover Model Y92A-48 Remarks --- Page 12 Flush Mounting Adapter Model Remarks Y92F-30 Included with models with screw terminals. Y92F-45 Use this Adapter to install the Counter/ Tachometer in a cutout previously made for a DIN 72 × 72 mm device (panel cutout: 68 × 68 mm). Page 12 Waterproof Packing Model Y92S-29 Remarks Included with models with screw terminals. Page 12 Connection Sockets Model P2CF-11 P2CF-11-E P3GA-11 Classification Connectable Counter/ Tachometers Remarks Page Front-connecting Socket --- Front-connecting Socket (Finger-safe Type) Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals. 13 H7CX-@11@-N A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction. Back-connecting Sockets Terminal Covers for P3GA-11 Back-connecting Socket Model Y92A-48G 4 Remarks --- Page 13 H7CX-A@-N H7CX-A@-N Multifunction Preset Counter • Easy to check the output status from a long distance with changing display colors*1 (red, green, and orange). • Includes total and preset counter, batch counter, dual counter, twin counter, and tachometer.*2 *1. Not supported by the H7CX-A11@-N. *2. The functions that can be selected depend on the model. Specifications Ratings Item Models Classification Configuration Ratings H7CX-A114@-N H7CX-A11@-N H7CX-A4@-N H7CX-A4W@-N Preset counter 1-stage/2-stage preset counter, total and preset counter*1, batch counter, dual counter, and twin counter (selectable) 1-stage preset counter, 1-stage preset counter with total counter (selectable)*1 • 100 to 240 VAC, 50/60 Hz • 24 VAC, 50/60 Hz or 12 to 24 VDC Operating voltage fluctuation range 85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%) 1-stage/2-stage preset counter, total and preset counter*1, batch counter, dual counter, twin counter, and tachometer (selectable) • 100 to 240 VAC at 50/ 60 Hz • 24 VAC at 50/60 Hz or 12 to 24 VDC • 12 to 24 VDC • 100 to 240 VAC, 50/60 Hz • 12 to 24 VDC Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx. 3.7 W at 12 to 24 VDC Mounting method Flush mounting or surface mounting Flush mounting External connections 11-pin socket Screw terminals Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29 Waterproof Packing is used. Input signals CP1, CP2, reset, and total reset Counter H7CX-AW@-N/-AU@-N Preset counter/ tachometer Power supply voltage*2 Power consumption H7CX-A@-N CP1, CP2, reset 1, and reset 2 Maximum counting speed 30 Hz or 5 kHz (switchable) (ON/OFF ratio 1:1)*3 *Common setting for CP1 and CP2 Input mode Increment, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)) Output mode N, F, C, R, K-1, P, Q, A, K-2, D, and L. One-shot output time 0.01 to 99.99 s Reset system N, F, C, R, K-1, P, Q, A, K-2, D, L, and H. External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation) Tachometer Refer to the separate table for tachometer function ratings. Prescaling function Yes (0.001 to 9.999) Decimal point adjustment Yes (rightmost 3 digits) Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) Input method No-voltage inputs: ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input: High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) No-voltage input/voltage input (switchable) External power supply 12 VDC (±10%), 100 mA (except for H7CX-A@D models) Refer to Precautions for Correct Use on page page 53 for details. Control output • Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) • Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V), Leakage current: 0.1 mA max. Display*4 7-segment, negative transmissive LCD Character height Count value: 12 mm (red) Set value: 6 mm (green) 7-segment, negative transmissive LCD Character height Count value: 10 mm (red) Set value: 6 mm (green) 7-segment, negative transmissive LCD Character height Count value: 12 mm (red, green, or orange selectable) Set value: 6 mm (green) 7-segment, negative transmissive LCD Character height Count value: 10 mm (red, green, or orange selectable) Set value: 6 mm (green) 7-segment, negative transmissive LCD Character height Count value: 12 mm (red, green, or orange selectable) Set value: 6 mm (green) 7-segment, negative transmissive LCD Character height Count value: 10 mm (red, green, or orange selectable) Set value: 6 mm (green) Digits 4 digits −999 to 9999 (−3 digits to +4 digits) 6 digits −99999 to 999999 (−5 digits to +6 digits) 4 digits −999 to 9999 (−3 digits to +4 digits) 6 digits −99999 to 999999 (−5 digits to +6 digits) 4 digits −999 to 9999 (−3 digits to +4 digits) 6 digits −99999 to 999999 (−5 digits to +6 digits), tachometer: 0 to 999999 Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Operating temperature range −10 to 55°C (−10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation) Storage temperature range −25 to 70°C (with no icing or condensation) Operating humidity range 25% to 85% Case color Black (N1.5) (Optional Front Panels are available to change the Front Panel color to light gray or white.) Attachments Yes (0.001 to 99.999) --- Yes (0.001 to 9.999) Yes (0.001 to 99.999) Yes (0.001 to 9.999) Flush mounting adapter, waterproof packing, terminal cover Yes (0.001 to 99.999) Flush mounting adapter, waterproof packing, terminal cover, label for DIP switch settings *1. 1-stage preset counter and total counter functionality. *2. Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power. *3. A response of 10 kHz is possible if the response speed is 5 kHz and the 1-stage preset counter input mode is increment, decrement, or increment/ decrement (command input). *4. The display is lit only when the power is ON. Nothing is displayed when power is OFF. 5 H7CX-A@-N Tachometer Function Ratings Model H7CX-A114@-N H7CX-A11@-N H7CX-A4@-N H7CX-A@-N H7CX-A4W@-N Item H7CX-AW@-N/-AU@-N Input mode Selectable from independent measurements for 1 or 2 inputs, differential input for 2 inputs, absolute ratio for 2 inputs, and error ratio for 2 inputs. Pulse measurement method Periodic measurement Pulse width measurement Maximum counting speed 30 Hz 1-input mode: 10 kHz Other modes: 5 kHz Minimum input signal width --- --- 30 ms*1 1-input mode: 0.2 ms Other modes: 0.4 ms* Measuring ranges 0.01 to 30.00 Hz 1-input mode: 0.01 to 10 kHz, Other modes: 0.01 to 5 kHz 0.030 to 999999 s 1-input mode: 0.0002 to 99999 s Other modes: 0.0004 to 99999 s 200 ms min. 200 ms min. or continuous selectable (minimum interval of 10 ms) Continuous (minimum interval of 10 ms) No tachometer functionality Sampling period 30 Hz 1-input mode: 10 kHz Other modes: 5 kHz Measuring accuracy ±0.1% FS ±1 digit max. (at 23 ±5°C) Output mode Input mode: Not 2-input independent measurement: HI-LO, AREA, HI-HI, LO-LO 2-input independent measurement: HI-HI, LO-LO Auto-zero time 0.1 to 999.9s Startup time 0.0 to 99.9s Averaging Simple averaging/moving averaging selectable, Processing: OFF, 2, 4, 8, or 16 times Hold input Minimum input signal width: 20 ms * An input OFF time of at least 20 ms is required. Characteristics Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and noncurrent-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit for all models except H7CX-@D@ (1,000 VAC for 24 VAC/12 to 24 VDC) 1,000 VAC (for H7CX-@SD@), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC for models other than H7CX-@SD@) 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts 3.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC) Impulse withstand voltage 4.5 kV between current-carrying terminals and exposed non-current-carrying metal parts (1.5 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC) Noise immunity ±1.5 kV between power terminals (±480 V for models with 12 to 24 VDC) ±600 V between input terminals Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Malfunction: 8 kV Destruction: 15 kV Vibration resistance Destruction 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each Malfunction 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each Shock resistance Destruction 300 m/s2 each in three directions Malfunction 100 m/s2 each in three directions Life expectancy Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature condition: 23°C)* Weight Approx. 130 g (Counter only) * Refer to the Life-test Curve. Applicable Standards Approved safety standards cULus (or cURus): UL508/CSA C22.2 No. 14* EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II B300 PILOT DUTY 1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3 A resistive load VDE0106/P100 (finger protection) (EMI) Emission Enclosure: Emission AC mains: (EMS) Immunity ESD: EMC EN61326 EN 55011 Group 1 class A EN 55011 Group 1 class A EN61326 EN 61000-4-2: 4 kV contact discharge; 8 kV air discharge Immunity RF-interference: EN 61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) Immunity Conducted Disturbance: EN 61000-4-6: 10 V (0.15 to 80 MHz) Immunity Burst: EN 61000-4-4: 2 kV power-line; 1 kV I/O signal-line Immunity Surge: EN 61000-4-5: 1 kV line to lines (power and output lines); 2 kV line to ground (power and output lines) Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage) * The following safety standards apply to models with sockets (H7CX-A11@ or H7CX-A114@). cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used. cUR (Recognition): Applicable when any other socket is used. 6 Life-test Curve (Reference Values) Resistive load No. of operations ( ×103) 100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed noncurrent-carrying metal parts, and between non-continuous contacts 1,000 700 500 300 30 VDC (cosφ=1) 250 VAC (cosφ=1) 100 70 50 0 1 2 3 4 Load current (A) Inductive load No. of operations ( ×103) Insulation resistance 1,000 700 500 300 30 VDC (L/R=7 ms) 100 250 VAC (cosφ=1) 70 50 0 1 2 3 4 Load current (A) A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected. H7CX-A@-N I/O Functions Using as a Counter*1 CP1, CP2 (1) In general (except for Dual Counter Mode) • Reads counting signals. • Increment, decrement, command, individual, and quadrature inputs accepted. (2) When used as a dual counter or twin counter • Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input. • Increment signals can be input. Reset/reset 1 (1) In general (except for Dual Counter Mode) • Resets present value and outputs (OUT2 when using the batch counter)*2. • Counting cannot be performed during reset/reset 1 input. • Reset indicator is lit while reset input is ON. (2) When used as a dual counter or twin counter. • Resets the CP1 present value (to 0). • Counting for CP1 input cannot be performed while the reset 1 input is ON. • The reset indicator is lit while the reset 1 input is ON. Total reset or reset 2 The reset function depends on the selected configuration*3. OUT1, OUT2 Outputs signals according to the specified output mode when a set value is reached. Inputs Outputs *1. For information on operation of I/O functions, refer to pages page 22 to page 25. *2. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models. *3. Reset operates as described in the following table. (The reset indicator will not be lit.) Configuration Reset operation 1-stage/2-stage preset counter Does not operate (not used). Total and preset counter • Resets the total count value. • The total count value is held at 0 while the total reset input is ON. Batch counter • Resets the batch count value and batch output (OUT1). • The batch count value is held at 0 while the reset 2 input is ON. Dual counter • Resets the CP2 present value. • Counting for CP2 input cannot be performed while the reset 2 input is ON. Twin counter • Resets the CP2 present value. • The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values) Minimum reset signal width Output delay time 1 ms 0.8 to 1.2 ms 20 ms 15 to 25 ms Operating Procedures (Tachometer Function) Inputs Outputs CP1, CP2 Reads counting signals. (The CP2 input can be used when the input mode is not 1-input mode.) Reset/reset 1 • Holds the measurement value and outputs. (The reset 2 input can be used when the input mode is 2-input independent measurement.) • The reset indicator is lit when the value is being held. OUT1, OUT2 Outputs signals according to the specified output mode when a set value is reached. 7 H7CX-A@-N Connections Terminal Arrangement Confirm that the power supply meets specifications before use. H7CX-AD-N/-A4D-N 9 10 Total reset 8 8 9 10 4 5 7 2 3 0V 6 (−) Sensor CP1 7 0V CP2 CP1 6 Total reset 10 CP2 0V 1-stage Transistor Output Reset CP1 CP2 Total reset 1-stage Contact Output Reset 1-stage Contact Output H7CX-AS-N/-A4S-N Reset H7CX-A-N/-A4-N 7 8 9 6 (−) Sensor (+) (+) 12 VDC 12 VDC 11 11 External power supply External power supply 1 2 3 4 1 5 2 3 4 5 1 OUT OUT (−) OUT (+) Terminals 1 and 6 are connected internally. H7CX-AW-N/-A4W-N/-AWD1-N/-AU-N/-AUD1-N 9 10 10 (+) *1 11 12 13 2 3 4 1 5 2 3 12 VDC 8 9 13 2 3 4 3 4 5 (+) H7CX-A11S-N/-A114S-N/-A11SD1-N Reset CP2 5 6 7 4 8 3 9 10 2 1 11 Total reset 0V (−) Sensor (+) 12 VDC Internal circuit 5 6 7 4 8 3 2 1 11 9 10 12 VDC External power supply OUT (−) OUT2 (−) OUT1 1-stage Transistor Output External power supply 5 13 CP1 (−) Sensor (+) 1 (−) Internal circuit Total reset OUT1 2 * CP1 10 12 OUT2 Reset 0V 12 13 1-stage Contact Output Reset 2 CP1 CP2 Reset 1 7 1 (+) CP2 6 10 11 *1: “-AU@” Models H7CX-A11-N/-A114-N/-A11D1-N/-A114D1-N 2-stage Transistor Output 9 External power supply 12 (−) H7CX-AWSD-N/-A4WSD-N 0V 5 (+) Terminals 1 and 6 are connected internally. 8 (+) OUT1 OUT2 OUT (−) 4 6 (−) Sensor External power supply 1 7 0V 6 12 VDC Reset 2 8 CP1 7 0V (−) Sensor CP2 Reset 2 9 CP1 8 CP2 7 2-stage Transistor Output Reset 1 0V 6 2-stage Contact Output Total reset CP1 CP2 Reset 1-stage Transistor Output H7CX-AWS-N/-AWSD1-N/-AUSD1-N Reset 1 H7CX-ASD-N/-A4SD-N (+) OUT (−) (+) (+) Terminals 1 and 6 are connected internally. Transistor Output • The transistor output of the H7CX is isolated from the internal circuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. NPN Output PNP Output Load + Power for load 8 • The diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the H7CX. Counter + Load + Power for load Power for load Inductive load H7CX-A@-N Block Diagram Input Circuits (Basic insulation) CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input Power supply circuit Output circuit (Basic insulation) (See note.) No-voltage Inputs (NPN Inputs) Display circuit Internal control circuit Input circuits Key switch circuit Voltage Inputs (PNP Inputs) +14V Approx. 4.7 kΩ 1 kΩ Note: All models except for H7CX-@D-N have basic insulation. Internal circuit IN Internal circuit IN Input Connections The inputs of the H7CX-@-N are no-voltage (short-circuit or open) inputs or voltage inputs. No-voltage Inputs (NPN Inputs) Open Collector Voltage Output PLC or sensor DC Two-wire Sensor 6 7 8 9 10 3 7 5 6 4 Note: Operates with transistor ON. 6 7 8 9 10 3 7 5 6 4 H7CX-A@ H7CX-A11@ Note: Operates with transistor ON. 6 7 8 9 10 3 7 5 6 4 Note: Operates with relay ON. H7CX-A@ H7CX-A11@ Total reset/reset 2 input CP1 input CP2 input 0 V for inputs Reset/reset 1 input Total reset/reset 2 input CP1 input CP2 input 0 V for inputs Reset/reset 1 input Total reset/reset 2 input CP1 input CP2 input 0 V for inputs H7CX-A@ H7CX-A11@ Reset/reset 1 input Total reset/reset 2 input CP1 input Reset/reset 1 input CP2 input Sensor 0 V for inputs H7CX-A@ H7CX-A11@ Contact Input 6 7 8 9 10 3 7 5 6 4 Note: Operates with transistor ON. No-voltage Input Signal Levels No-contact input Applicable Two-wire Sensor Short-circuit level (transistor ON) • Residual voltage: 3 V max. • Impedance when ON: 1 kΩ max. • Leakage current: 1.5 mA max. • Switching capacity: 5 mA min. • Residual voltage: 3 VDC max. • Operating voltage: 10 VDC (The leakage current is approx. 12 mA when the impedance is 0 Ω.) Open level (transistor OFF) • Impedance when OFF: 100 kΩ min. Contact input Use contacts which can adequately switch 5 mA at 10 V. Note: The DC voltage must be 30 VDC max. Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) No-contact Input (PNP Transistor) 7 8 9 10 3 7 5 6 4 Note: Operates with transistor OFF. H7CX-A@ H7CX-A11@ Total reset/reset 2 input CP1 input CP2 input 0 V for inputs Reset/reset 1 input CP1 input Total reset/reset 2 input CP2 input 0 V for inputs Total reset/reset 2 input CP1 input CP2 input Reset/reset 1 input 0 V for inputs 6 Reset/reset 1 input Sensor Sensor H7CX-A@ H7CX-A11@ Contact Input 6 7 8 9 10 H7CX-A@ 6 7 8 9 10 3 7 5 6 4 H7CX-A11@ 3 7 5 6 4 Note: Operates with transistor ON. Note: Operates with relay ON. Voltage Input Signal Levels High level (input ON): 4.5 to 30 VDC Low level (input OFF): 0 to 2 VDC Note: 1. The DC voltage must be 30 VDC max. 2. Input resistance: Approx. 4.7 kΩ 9 H7CX-A@-N Nomenclature Display Section Operation Keys 4 1. Key Protect Indicator (orange) 2. Control Output Indicator (orange) OUT: (One-stage) OUT: 1 2 (Two-stage) 3. Reset Indicator (orange) (Lit when the reset input (1) or Reset Key is ON.) Displayed only when the configuration selection mode is not tachometer mode. 7 2 3 5 10 8 11. Reset Key (See note.) 6 12 11 13 12. Up Keys 1 to 4 (6-digit models: 1 to 6 ) 4th digit 1st digit (Front view of 4-digit model) (Lit when the total count value is displayed.) Switches 5. Batch Indicator 14. Key-protect Switch (Lit when the batch count value is displayed.) 1 * Characters on models with screw terminals (H7CX-A11@) can be switched between red, green, and orange. 2 3 9 10 RST ON (Enable) 6 12 11 8. Set value (Sub-display) (Default setting) OFF (Disable) 7 4 5 8 6. Set Value 1, 2 Stage Indicator (Character height: 12 mm (6-digit: 10 mm), red*) (Changes modes and setting items.) 13. Down Keys 1 to 4 4. Total Count Indicator 7. Present Value (Main Display) 10. Mode Key 1 15. DIP Switch (Character height: 6 mm, green) ON 6th digit 9. Hold Display (orange) Displayed only when the configuration selection mode is not tachometer mode. 1st digit (Front view of 6-digit model) OFF 1 2 3 4 5 6 7 8 Note: The reset functions depends on the selected configuration. Model with 4 Digits Character Size for Main Display Configuration Character Size for Sub-display 12 mm 6 mm 14 15 Resets the present value and outputs. Total and preset counter • Resets the present value and outputs. • When the total count value is displayed, resets the present value, the total count value, and outputs. Batch counter • Resets the present value and OUT2. • When the batch count value is displayed, resets the present value, the batch count value, and outputs. Dual counter Resets the CP1 present value, CP2 present value, dual count value, and outputs. Twin counter Resets the CP1 present value and output 1 when the CP1 present value is displayed. Resets the CP2 present value and output 2 when the CP2 present value is displayed. Tachometer Holds the measurement value and outputs (hold function). (When the input mode is 2-input independent measurement, the CP1 measurement value display will hold the CP1 measurement value and output 1 and the CP2 measurement value display will hold the CP2 measurement value and output 2.) Model with 6 Digits Character Size for Main Display Character Size for Sub-display 10 mm 6 mm Reset operation 1-stage/2-stage preset counter Dimensions (Unit: mm) Counters H7CX-A-N/-AS-N/-AW-N/-AWS-N/-AWD1-N/-AWSD1-N/-A4-N/-A4S-N/-A4W-N/-AU-N/-AUD1-N/-AUSD1-N (Flush Mounting Models) 48 × 48 6 78 44.8 × 44.8 Note: M3.5 terminal screw (effective length: 6 mm) 10 H7CX-A@-N H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/-A4SD-N/-A4WSD-N (Flush Mounting Models) 48 × 48 6 59 44.8 × 44.8 Note: M3.5 terminal screw (effective length: 6 mm) H7CX-A11-N/-A11S-N/-A11D1-N/-A11SD1-N/-A114-N/-A114S-N/-A114D1-N (Flush Mounting/Surface Mounting Models) 48 × 48 6 63.7 14.4 44.8 × 44.8 Dimensions with Flush Mounting Adapter H7CX-A-N/-AS-N/-AW-N/-AWS-N/-AWD1-N/-AWSD1-N/-A4-N/-A4S-N/-A4W-N (Provided with Adapter and Waterproof Packing) Y92S-29 (provided) Waterproof Packing Panel Panel Cutouts Panel cutouts are as shown below. (according to DIN43700). Y92F-30 (provided) Flush Mounting Adapter 60 min. 45+0.6 0 45+0.6 0 58 15 min. 60 min. (51) 48 7.5 76.5 H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/-A4SD-N/-A4WSD-N (Provided with Adapter and Waterproof Packing) Y92S-29 (provided) Waterproof Packing 58 Panel Y92F-30 (provided) Flush Mounting Adapter (51) Note: 1. The mounting panel thickness should be 1 to 5 mm. 2. To allow easier operation, it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm (i.e., with the panel cutouts separated by at least 60 mm). 3. It is possible to mount counters side by side, but only in the direction without the hooks. If they are mounted side-by-side, waterresistance will be lost. n Units mounted side by side A A=(48n−2.5) +1 −0 48 7.5 57.5 H7CX-A11-N/-A11S-N/-A11D1-N/-A11SD1-N/-A114-N/-A114S-N/-A114D1-N (Adapter and Waterproof Packing Ordered Separately) Y92S-29 (order separately) Waterproof Packing 58 Panel Y92F-30 (order separately) Flush Mounting Adapter With Y92A-48F1 attached. A={48n−2.5+(n−1)×4} +1 −0 With Y92A-48 attached. A=(51n−5.5) +1 −0 Dimensions with Front Connecting Socket (51) 103.2* 48 7.5 H7CX -A11@ 100.9 89.9 P2CF-11(-E) Front Connecting Socket (order separately) * These dimensions depend on the kind of DIN Track. (Reference value) 11 H7CX-A@-N Accessories (Order Separately) Note: Depending on the operating environment, the condition of resin products may deteriorate, and may shrink or become harder. Therefore, it is recommended that resin products are replaced regularly. Soft Cover Hard Cover Y92A-48F1 Y92A-48 Front Panel (Replacement Part) You can change the color of the Front Panel when mounting the Counter/Tachometer. The Counter/Tachometer is shipped with a black (N1.5) Front Panel. "COUNTER" is printed on the front of Replacement Front Panels. Y92P-CXC4G 4-digit Counter Light gray (5Y7/1) Y92P-CXC4S 4-digit Counter White (5Y9.2/0.5) Y92P-CXT4B The H7CX's panel surface is water-resistive (conforming to IP@6, UL Type 4X) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54F against oil. Do not, however, use the H7CX in locations where it would come in direct contact with oil. Flush Mounting Adapter 4-digit Counter Black (N1.5) Y92P-CXT6G 6-digit Counter Light gray (5Y7/1) Y92F-30 Y92F-45 Order the Flush Mounting Adapter with the following model number separately if it is lost or damaged. Use this Adapter to install the Counter/ Tachometer in a cutout previously made for a DIN 72 × 72 mm device (panel cutout: 68 × 68 mm). Note: The Waterproof Packing is included with models with screw terminals. Y92P-CXT6S 6-digit Counter White (5Y9.2/0.5) Y92P-CXT6B 6-digit Counter Black (N1.5) Waterproof Packing Y92S-29 Replacement Method Tabs Grooves 12 Protecting the Counter/Tachometer in Environments Subject to Oil The Front Panel is attached to the Counter/Tachometer with tabs in four locations. To remove the Front Panel, open the tabs and pull the Front Panel forward. To attach the Front Panel, press it onto the Counter/Tachometer so that all four tabs lodge into the grooves on the body of the Counter/Tachometer. Note: The Waterproof Packing is included with models with screw terminals. Order the Waterproof Packing separately if it is lost or damaged. The Waterproof Packing can be used to achieve IP66 protection. The Waterproof Packing will deteriorate, harden, and shrink depending on the application environment. To ensure maintaining the IP@6, UL Type 4X waterproof level, periodically replace the Waterproof Packing. The periodic replacement period will depend on the application environment. You must confirm the proper replacement period. Use 1 year or less as a guideline. If the Waterproof Packing is not replaced periodically, the waterproof level will not be maintained. It is not necessary to mount the Waterproof Packing if waterproof construction is not required. H7CX-A@-N Connection Sockets Front Connecting Socket Model Dimensions P2CF-11 50 max. Terminal arrangement and internal connections Mounting hole dimensions 31.2 max. Two, 4.5-dia. holes 70 max. 4 8 7 6 5 4 7.8 Eleven, M3.5 × 7.5 sems screws P2CF-11-E (Finger-safe Type) 8 50 max. 31.2 max. 40±0.2 30 7 6 40±0.2 9 3 10 5 3 Two, 4.5-dia. holes Two, M4 or 4.5-dia. holes 4 3 11 1 2 (Top View) P2CF-11-E Note: The Socket can also be mounted to DIN track. 4 70 max. 9 1.2 35.4 3 10A250VAC RESISTIVE 10 11 1 4 2 7.8 Eleven, M3.5 × 7.5 set screws 5 4.5 Note: Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals. Back-connecting Sockets Model Terminal arrangement and internal connections Dimensions P3GA-11 27 dia. 5 6 7 8 2 1 11 10 4 25.6 45 3 4.5 45 16.3 6.2 9 (Bottom View) Note: A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction. Terminal Covers for P3GA-11 Back-connecting Socket Model Dimensions Y92A-48G Twelve, 6.4-dia. holes 34 Y92A-48G UP 47.7 × 47.7 48 × 48 P C 16.5 24.6 27.6 47.4 Note: The Terminal Cover can be used with a Back-mounting Socket (P3GA-11) to create a finger-safe construction. 13 H7CX-A@-N Optional Products for Track Mounting Mounting Track PFP-100N PFP-50N 7.3±0.15 4.5 35±0.3 15 25 10 25 1,000 (500)* 25 10 15 (5)* 25 1 * The values shown in parentheses are for the PFP-50N. Mounting Track PFP-100N2 16 4.5 35±0.3 27 15 25 10 25 1,000 25 PFP-M 10 25 6.2 M4 × 8 pan head screw 50 1.8 1 35.5 35.3 1.8 11.5 10 M4 spring washer Spacer 1.3 4.8 16 12 5 PFP-S 34.8 44.3 16.5 Note: Order Spacers in increments of 10. 29.2 24 1 15 10 End Plate 14 27±0.15 1.5 H7CX-A@-N Counter Operating Procedures Setting Procedure Guide Setting for Counter Operation * Use the following settings. Setting for Tachometer Operation * Refer to page page 27. * At the time of delivery, the H7CX is set to the 1-stage preset counter configuration. (2-stage models are set to the 2-stage preset counter configuration.) Refer to page page 35 for information on switching models. I/O Functions for Counter Operation Step1 Set the basic parameters. (If the desired I/O mode is not listed below or to set all parameters using the front panel keys, perform Step3 , below.) Key-protect switch Be sure to set pin 1 to ON. ON OFF Item 1 DIP switch settings 2 Counting speed 3 Input mode 4 5 1 2 3 4 5 6 7 8 OFF ON Disabled Enabled 30 Hz 5 kHz UP DOWN Refer to the table on the right. Output mode 6 Output time 0.5 s 0.05 s 7 Minimum reset signal 20 ms 1 ms 8 Input selection NPN PNP Pin 4 Pin 5 Output mode OFF OFF N ON OFF F OFF ON C ON ON K-1 Note: All pins are factory-set to OFF. • When setting functions using the DIP switch, be sure to set pin 1 of the DIP switch to ON. • DIP switch settings are effective when the power is turned ON again. (Perform DIP switch settings while the power is OFF.) Step2 The H7CX-A@-N is a Counter that contains more than one functional counter. When using the Counter in any mode other than the default mode*, use the following chart to enter Configuration Selection Mode and set the functions that are suitable to the application. * The default mode is 1-stage preset counter configuration (2-stage preset counter configuration for 2-stage models). Note: Step2 can be performed first, followed by Step1 . Configuration selection mode Power ON 1 + Hold down for 1 s min. Select the function from Table 1 using the U (D) Key. Run mode 1 + Hold down for 1 s min. twn (1-stage preset counter) (2-stage preset counter) (Total and (Batch preset counter) counter) (Dual counter) (Twin counter) (Tachometer) Note: The configuration that can be selected depends on the model. After making DIP switch settings for basic operations, advanced functions can be added using the operation keys. For details, refer to page page 16. 15 H7CX-A@-N Counter Step3 Parameters that cannot be set with the DIP switch are set with the operation keys on the front panel. Change to Function Setting Mode. Power ON For details on operations and display in run mode, refer to page page 20. The display depends on the selected configuration. 3 s min.*1 Function setting mode Run mode 3 s min.*2 *1 If the mode is switched to the function setting mode during operation, operation will continue. *2 Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode. *3 Input mode (CNTM) The characters displayed in reverse video are the default settings. When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed. For 6-digit models, only U Keys are provided. *3 When Using Dual Counter Operation Displays for 6-digit models are given in parentheses. Dual count calculating mode (ADD) • Set the dual count calculating mode using the UD Keys. • Set the input mode using the U (D) Keys. *5 *5 down up ud-a ud-b ud-c (DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C) (UP) Note: Displayed only when Twin Counter Mode is not selected. *5 Displayed for output modes other than K-2, D, L, and H only. Output mode (OUTM) n (N) *7 add • Set the output mode using the U (D) Keys. f (F) c (C) r (R) k-1 (K-1) p (P) *4 sub (Addition) (Subtraction) q a (Q) (A) *6 k-2 (K-2) *6 Displayed only when the input mode is ud-a, ud-b, or ud-c. (Not displayed when the function is set to twn.) *6 d (D) *6 l (L) *4 Displayed only when the output mode is K-2, D, L, or H. *6 h (H) *7 Set each digit using the individual U (D) Keys. When using as a 2-stage preset counter Output time (OTIM) • Set each digit using the individual U (D) Keys. One-shot output 2 time (OTM2) 0.01 0.50 99.99 (0.01 s) (0.50 s) (99.99 s) Function Setting Mode Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. Counting speed (CNTS) 0.50 99.99 One-shot output 1 hold 0.01 99.99 time (Outputs held) (0.01 s) (99.99 s) (OTM1) If the output time is 0.00, hold is displayed. • Set the counting speed using the U (D) Keys. Note: Displayed for output modes other than D, L, and H. HOLD cannot be set when the output mode is K-2. 30hz (30 Hz) 0.01 (0.01 s) (0.50 s) (99.99 s) Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. (5 kHz) When using as a batch counter Reset input signal width (IFLT) Decimal point position (DP) 20ms 1ms (20 ms) (1 ms) NPN/PNP input mode (IMOD) output mode is C, R, K-1, P, Q, A, or K-2. • Set the decimal point position using the U (D) Keys. (No decimal point) Prescale value (PSCL) One-shot 0.01 0.50 99.99 output 2 (0.01 s) (0.50 s) (99.99 s) time (OTM2) Note: Displayed only when the • Set the Reset input signal width using the U (D) Keys. (One digit after decimal point) (Two digits after decimal point) *7 Set each digit using the individual U (D) Keys. • Set each digit using the individual U (D) Keys. 0.001 1.000 9.999 99.999 (0.001) (1.000) (9.999) (99.999) (Three digits after decimal point) Twin Counter Output 2 output time (OTM2) • Set the NPN/PNP input mode using the U (D) Keys. npn 0.01 0.50 99.99 (0.01 s) (0.50 s) (99.99 s) Note: Displayed only when the output mode is C, R, K-1, P, Q, or A. Output 1 0.01 0.50 99.99 output (0.01 s) (0.50 s) (99.99 s) time (OTM1) Note: Displayed only when the pnp (NPN input) (PNP input) output mode is C, R, K-1, P, Q, or A. Display color (COLR) • Set the display color using the U (D) Keys. red (Red) grn org r-g g-r r-o o-r Note: Displayed for terminal-block models (except H7CX-A11@) only. From next page To next page 16 g-o o-g (Green) (Orange) (Red-green) (Green-red) (Red-orange) (Orange-red) (Green-orange) (Orange-green) H7CX-A@-N Counter To previous From previous page page Absolute value setting/forecast value setting (SETM) • Make the absolute value setting and forecast setting using the U (D) Keys. abs ofst (ABS) (OFST) Note: Displayed only when the configuration selection mode is set to the 2-stage function 2cnt. Set value upper limit (SL-H) • Set each digit using the individual U (D) Keys. 1 9999 (1) (9999) Function Setting Mode Note: 1 to 999999 for 6-digit models Forecast setting upper limit (PL-H) • Set each digit using the individual U (D) Keys. 1 9999 (1) (9999) Note: 1 to 999999 for 6-digit models. Note: Displayed only when the configuration selection mode is set to the 2-stage function 2cnt and a forecast value is set. • Set each digit using the individual U (D) Keys. Batch count upper limit (BL-H) 1 9999 (1) (9999) Note: 1 to 999999 for 6-digit models. Note: Displayed only when the output mode is set to bcnt. Output allocation change off on (OFF) (ON) Note: Displayed only for "-AU@" models. off: Output 1 = 12, 13, Output 2 = 3, 4, 5 on: Output 1 = 3, 4, 5, Output 2 = 12, 13 The numbers are the terminals numbers. Key protect level (KYPT) • Set the key protect level using the U (D) Keys. kp-1 kp-2 kp-3 kp-4 kp-5 kp-6 kp-7 (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) (KP-6) (KP-7) *8 Output ON count alarm set value/monitor value *8 Set each digit using the individual U (D) Keys. Procedure for Models Other than “-@W@” Models Output ON count alarm set value Output ON count monitor value 0 9999 (0 × 1000 times) (9999 × 1000 times) Note: The monitor value is only displayed. It cannot be set. Procedure for “-@W@” Models Output 1 (OUT1) ON count alarm set value Output 2 (OUT2) ON count alarm set value 0 9999 0 9999 (0 × 1000 times) (9999 × 1000 times) (0 × 1000 times) (9999 × 1000 times) Output 1 (OUT1) ON count monitor value Note: The monitor value is only displayed. It cannot be set. Output 2 (OUT2) ON count monitor value Note: The monitor value is only displayed. It cannot be set. 17 H7CX-A@-N Counter Explanation of Functions Items marked with stars ★ can be set using the DIP switch. Input Mode (cntm)★ Prescale Value (pscl) Set increment mode (UP), decrement mode (DOWN), or one of the increment/decrement modes (UP/DOWN A, UP/DOWN B, or UP/ DOWN C) as the input mode. Input modes other than UP or DOWN modes cannot be set using the DIP switch and so use the operation keys if other modes are required. (For details on the operation of the input modes, refer to Input Modes and Present Value on page page 21.) Pulses input to the counter are converted according to the specified prescale value. (Setting range: 0.001 to 99.999 for 6-digit models and 0.001 to 9.999 for 4-digit models.) Example: To display the feed distance for systems that output 25 pulses for a feed length of 0.5 m in the form @@.@@ m: 1. Set the decimal point position to 2 decimal places. 2. Set the prescale value to 0.02 (0.5 ÷ 25). Dual Count Calculating Mode ( calm) When using as a dual counter, select either ADD (addition) or SUB (subtraction) as the calculation method for the dual count value. ADD: Dual count value = CP1 PV + CP2 PV SUB: Dual count value = CP1 PV − CP2 PV 0.5 m Output Mode (outm)★ Set the way that control output for the present value is output. The possible settings are N, F, C, R, K-1, P, Q, A, K-2, D, L, and H. Output modes other than N, F, C, or K-1 cannot be set using the DIP switch and so use the operation keys if other modes are required. The output modes that can be set vary with the model. (For details on the operation of the output modes, refer to Input/ Output Mode Settings on page page 22.) One-shot Output Time (otim)★ Set the one-shot output time (0.01 to 99.99 s) for control output. One-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is selected as the output mode. Output times other than 0.5 s or 0.05 s cannot be set with the DIP switch and so use the operation keys if other settings are required. One-shot Output 2 Time (otm2)★ Set the one-shot output time (0.01 to 99.99 s) for control output (OUT2). One-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is selected as the output mode. Output times other than 0.5 s or 0.05 s cannot be set with the DIP switch and so use the operation keys if other settings are required. One-shot Output 1 Time (otm1) Set the one-shot output time (0.01 to 99.99 s) for control output (OUT1). One-shot output can be used only when D, L, or H is selected as the output mode. If the output time is set to 0.00, hold is displayed, and outputs are held. Counting Speed (cnts)★ 25 pulses Encoder • Observe the following points when setting a prescale value. Set the set value to a value less than {Maximum countable value − Prescale value}. Example: If the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 − 1.25). If the set value is set to a value greater than this, output will not turn ON. • Output will turn ON, however, if a present value overflow occurs (FFFFFF or FFFF). Note: If the prescale value setting is incorrect, a counting error will occur. Check that the settings are correct before using this function. NPN/PNP Input Mode (imod) Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. When using a two-wire sensor, select NPN input. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page page 9. Display Color (colr) (Displayed for terminal block models (except H7CX-A11@) only.) Set the color used for the present value. Set the maximum counting speed (30 Hz/5 kHz) for CP1 and CP2 inputs together. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. red Red (fixed) grn Green (fixed) Reset Input Signal Width (iflt)★ org Set the reset input signal width (20 ms/1 ms) for reset/reset 1 and total reset/reset 2 inputs together. If contacts are used for the input signal, set the input signal width to 20 ms. Processing to eliminate chattering is performed for this setting. r-g Red g-r Green Red r-o Red Orange o-r Orange Red g-o Green Orange o-g Orange Green Decimal Point Position (dp) Decide the decimal point position for the present value, CP1/CP2 present values, set value (SV1, SV2), total count value, and dual count set value. Output OFF* Output ON* Orange (fixed) Green * Output 2 for 2-stage models. With the twin counter, output 1 and output 2 will both turn OFF when the output status is OFF. Either output 1 or output 2 will turn ON when the output status is ON. 18 H7CX-A@-N Counter Absolute Value Setting/Forecast Value Setting (setm) Output ON Count Alarm Set Value (on-a) For the 2 count output mode, an absolute value setting (abs) or forecast value setting (ofst) can be set for set value 1. When a forecast value is set, specify the forecast value set value (i.e., the deviation for the set value). The forecast output (output 1) turns ON when the present value reaches the forecast value. If the forecast set value is greater than or equal to the set value, the forecast output (output 1) will turn ON as soon as counting starts. Set the alarm value for the output ON count. The limit can be set to between 0 × 1000 (0 times) and 9999 × 1000 (9,999,000 times). Only the underlined values are set. The alarm will be disabled if 0 is set. If the total ON count of the output exceeds the alarm set value, e3 will be displayed on the Timer to indicate that the output ON count alarm value was exceeded. Refer to Self-diagnostic Function on page page 36 for information on the e3 display. Example: F Mode Count value Set value 2 Set value 1 0 Control output 1 (OUT1) Control output 2 (OUT2) If the forecast value setting is used, specify the set value 2 minus the forecast value setting for set value 1. Example: F Mode Count value Set value ON Count Alarm Set Values for Outputs 1 and 2 (OUT1 and OUT2) (on1a and on2a) Set the ON count alarm values for the outputs 1 and 2. The limit can be set to between 0 × 1000 (0 times) and 9999 × 1000 (9,999,000 times). Only the underlined values are set. The alarm will be disabled if 0 is set. If the total ON count of instantaneous output 1 or 2 exceeds the alarm set value, e3 will be displayed on the Timer to indicate that the output ON count alarm value was exceeded. Refer to Self-diagnostic Function on page page 36 for information on the e3 display. Output ON Count Monitor Value (on-c) The monitor value is only displayed. It cannot be set. The output ON count will be 1,000 times the displayed value. Forecast set value ON Count Monitor Values for Outputs 1 and 2 (OUT1 and OUT2) (on1c and on2c) Forecast value 0 The monitor value for output 1 or 2 is only displayed. It cannot be set. The output ON count will be 1,000 times the displayed value. Forecast output (OUT1) Control output (OUT 2) Set Value Upper Limit (sl-h) Set the upper limit for the set value when it is set in run mode. The setting can be made from 1 to 9999 for 4-digit models and from 1 to 999999 for 6-digit models. Forecast Set Upper Limit (pl-h) Set the upper limit for the forecast set value. The setting can be made from 1 to 9999 for 4-digit models and from 1 to 999999 for 6-digit models. Batch Count Upper Limit (bl-h) Set the upper limit for the batch count value. The setting can be made from 1 to 9999 for 4-digit models and from 1 to 999999 for 6-digit models. Output Allocation (otst) When using an H7CX-AU@-N model as a 2-stage counter, the output can be flexibly allocated to either stage 1 or 2. The transistor output can be allocated to SV1 and the contact output to SV2 or vice verse, as in the following tables. H7CX-AU-N/-AUD1-N Output 1 Output 2 off Transistor (12-13) Contact (3, 4, 5) on Contact (3, 4, 5) Transistor (12-13) H7CX-AUSD1-N Output 1 Output 2 off Transistor (12-13) Transistor with diode (3, 4, 5) on Transistor with diode (3, 4, 5) Transistor (12-13) Key Protect Level (kypt) Set the key protect level. Refer to Key Protect Level on page page 36. 19 H7CX-A@-N Counter Operation in Run Mode I/O Functions for Counter Operation • Set values for each digit as required using the U (D) Keys. (U Key only for 6-digit models.) 1-stage Preset Counter Total and Preset Counter Dual Counter Present value Set value Present value Dual count value Set value Dual count set value Total count value CP1 present value 2-stage Preset Counter with Absolute Value Setting Present value CP2 present value Set value 1 • Present Value/Set Value Same as 1-stage preset counter. Present value Set value 2 • Total Count Value Shows the present total count value. • Present Value Shows the present count value. • Set Values (Set Value 1 and Set Value 2) Set the set values. When the present value reaches the set value (set value 1 or set value 2), a signal is output according to the specified output mode. • Dual Count Value Shows the sum of the CP1 present value and CP2 present value when the dual count calculating mode is ADD and shows the value obtained by subtracting the CP2 present value from the CP1 present value when the dual count calculating mode is SUB. • Dual Count Set Value Set the dual count set value. When the dual count value reaches the dual count set value, signals are output according to the specified output mode. Batch Counter Present value Set value • CP1/CP2 Present Value Show the present count values for CP1 and CP2 present values respectively. 2-stage Preset Counter with Forecast Value Setting Batch count value Present value Batch count set value Set value • Present Value/Set Value Same as 1-stage preset counter. Present value Forecast Set Value • Present Value Shows the present count value. 20 Twin Counter Present value 1 Set value 1 • Batch Count Value Shows the number of times the count has been completed for the present value. • Batch Count Set Value Set the batch count set value. When the batch count value reaches the batch count set value, batch output (OUT1) turns ON. Present value 2 Set value 2 • Set Values Set the set values. • Present Values 1 and 2 Shows the present count value 1 or 2. • Forecast Set Value Set the deviation for the set value. • Set Values 1 and 2 Setting for present value 1 or 2. H7CX-A@-N Counter Input Modes and Present Value (See note 1.) I/O Functions for Counter Operation UP (Increment) Mode DOWN (Decrement) Mode CP1: Count input; CP2: Prohibit (gate) input CP1: Count input; CP2: Prohibit (gate) input H H CP1 CP1 L L A A A H A Prohibit Prohibit H CP2 CP2 L L n 5 n−1 4 Present value n−2 Present value 3 n−3 2 n−4 1 0 n−5 0 0 A must be greater than the minimum signal width. (See note 2.) A must be greater than the minimum signal width. (See note 2.) CP1: Prohibit (gate) input; CP2: Count input CP1: Prohibit (gate) input; CP2: Count input H H *CP1 *CP1 L L A A A Prohibit H CP2 A Prohibit H CP2 L L n 5 n−1 n−2 4 Present value Present value 3 n−3 2 n−4 1 n−5 0 0 0 A must be greater than the minimum signal width. (See note 2.) A must be greater than the minimum signal width. (See note 2.) * Counting starts when the CP1 is turned ON after turning ON the power. UP/DOWN A Command Input Mode UP/DOWN B Individual Input Mode H H CP1 CP1 L L A A H H CP2 CP2 L L 3 Present value Present value 2 2 1 0 3 3 2 2 3 1 1 0 0 2 2 1 1 0 A must be greater than the minimum signal width. (See note 2.) Note: 1. If the configuration selection is set to dual counter, CP1 and CP2 input will operate in the same way as the count input (CP1) of UP (increment) mode. 2. A must be greater than the minimum signal width and B must be at least 1/2 the minimum signal width. If they are less, a count error of ±1 may occur. UP/DOWN C Quadrature Input Mode H CP1 L B B B B H CP2 L 3 Present value 2 1 0 3 2 2 1 0 B must be at least 1/2 the minimum signal width. (See note 2.) Minimum signal width: 16.7 ms (when maximum counting speed = 30 Hz) 100 µs (when maximum counting speed = 5 kHz) 3. The meaning of the H and L symbols in the tables is explained below. Symbol Input method No-voltage input (NPN input) Voltage input (PNP input) H Short-circuit 4.5 to 30 VDC L Open 0 to 2 VDC 21 H7CX-A@-N Counter Input/Output Mode Settings I/O Functions for Counter Operation If a 1-stage model or 2-stage model is incorrectly used as twin counter, the operation for output 2 will be performed. When using a 2-stage model as a 1-stage preset counter, total and preset counter, or dual counter, OUT1 and OUT2 turn ON and OFF simultaneously. One-shot output from OUT1 (The one-shot output time can be set in the range 0.01 to 99.99s.) Self-holding output Self-holding One-shot output output from OUT2 Input mode UP DOWN UP/DOWN A, B, C Operation after count completion Reset/ reset 1 999999 Set value 2 N Set value 1 0 The outputs and present value display are held until reset/reset 1 is input. OUT1 OUT2 Reset/ reset 1 999999 Set value 2 Set value 1 F 0 The present value display continues to increase/decrease. The outputs are held until reset/reset 1 is input. OUT1 OUT2 Reset/ reset 1 999999 Set value 2 Output mode setting Set value 1 C 0 OUT1 OUT2 Reset/ reset 1 999999 Set value 2 Set value 1 R 0 OUT1 OUT2 Reset/ reset 1 999999 Set value 2 K-1 Set value 1 0 OUT1 OUT2 22 As soon as the count reaches SV, the present value display returns to the reset start status. The present value display does not show the present value upon countup. The outputs repeat oneshot operation. OUT1 self-holding output turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output time is independent of OUT2. The present value display returns to the reset start status after the one-shot output time. The outputs repeat oneshot operation. OUT1 self-holding output turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output time is independent of OUT2. The present value display continues to increase/decrease. OUT1 self-holding output turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output time is independent of OUT2. H7CX-A@-N Counter One-shot output from OUT1 (The one-shot output time ca set in the range 0.01 to 99.9 Self-holding output Self-holding One-shot output output from OUT2 Input mode UP Reset/ reset 1 999999 Set value 2 Set value 1 0 P OUT1 OUT2 Reset/ reset 1 999999 Set value 2 Output mode setting Set value 1 0 Q OUT1 OUT2 DOWN UP/DOWN A, B, C Operation after count completion The present value display does not change during the one-shot output time period, but the actual count returns to the reset start status. The output will return to one-shot mode. The outputs repeat one-shot operation. OUT1 self-holding output turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output time is independent of OUT2. The present value continues to increase/ decrease for the oneshot output time, but returns to the reset start status after the one-shot output time has elapsed. The outputs repeat one-shot operation. OUT1 self-holding output turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output time is independent of OUT2. Reset/ reset 1 999999 Set value 2 Set value 1 A 0 OUT1 The present value display and OUT1 self-holding output is held until reset/reset 1 is input. OUT1 and OUT2 are independent. OUT2 Note: 1. 2. 3. 4. 5. The full scale (FS) for H7CX 4-digit models is 9999. When the present value reaches 999999, it returns to 0. Counting cannot be performed during reset/reset 1 input. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered. 6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON. 7. The setting range is 0 to 999,999 (0 to 9,999 for 4-digit models). 23 H7CX-A@-N Counter (The one-shot output time can be set in the range 0.01 to 99.99s.) Self-holding Instantaneous One-shot output (equals) output output Input mode Operation after count completion UP/DOWN A, B, C Reset/ reset 1 999999 Set value 2 Set value 1 0 K-2 −99999 The display continues to increase/ decrease until the overflow or underflow value is reached. One-shot output only. OUT1 OUT2 Reset/ reset 1 999999 Set value 2 Set value 1 0 D −99999 The display continues to increase/ decrease until the overflow or underflow value is reached. The outputs are ON while the count is equal. OUT1 OUT2 Output mode setting Reset/ reset 1 999999 Set value 2 Set value 1 L 0 −99999 The display continues to increase/ decrease until the overflow or underflow value is reached. OUT1 is held while the present value is less than or equal to set value 1. OUT2 is held while the present value is greater than or equal to set value 2. OUT1 OUT2 Reset/ reset 1 999999 Set value 2 Set value 1 H 0 −99999 OUT1 The display continues to increase/ decrease until the overflow or underflow value is reached. OUT1 is held while the present value is greater than or equal to set value 1. OUT2 is held while the present value is greater than or equal to set value 2. * H mode is available only when using a 6digit model as a 2-stage counter. OUT2 Note: 1. Counting cannot be performed during reset/reset 1 input. 2. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF. 3. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered. 4. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON. 5. The set value is from −99999 to 999999. 24 H7CX-A@-N Counter Total and Preset Counter Operation The H7CX has a total counter, separate from the 1-stage preset counter, for counting the total accumulated value. • The total counter continues to count the total accumulated value when the present value is reset using reset/reset 1 input (Reset Key). • The total count value is reset when the total reset/reset 2 input is turned ON. If the Reset Key is pressed while the total count value is displayed, the total count value is reset. The present value is also reset at this time. • The counting range of the total counter is −99,999 to 999,999 (−999 to 9,999). The total count value returns to 0 when it reaches the full scale limit. Reset/reset 1 Total Reset or Reset 2 Present value 0 999999 Total count value 0 Note: The full scale (FS) for H7CX 4-digit models is 9999. Batch Counter Operation The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed. • The batch counter continues after count completion. • Batch output is held until batch counter reset is input. • When the batch counter reset input is turned ON, the batch count value is reset, and batch output turns OFF. • If the Reset Key is pressed while the batch count value is displayed, the batch count value is reset and batch output turns OFF. The present value is also reset at this time. • The count value can be incremented and decremented. The batch count is only incremented. • The maximum counting speed for batch counter operation is 5 kHz. The batch counter counts the number of times the count reaches the set value. Reset 1 Reset 2 (batch counter reset) Set value Present value 0 OUT2 Batch count set value Sub-display 2 Batch count value (Main display) 0 OUT1 (batch output) Note: 1. 2. 3. 4. 5. 6. 1 Note: The above is for when the output mode is C. The batch count value is held at 0 during batch counter reset input. If the batch count set value is 0, batch count will be performed but there will be no batch output. The batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models). Once batch input has been turned ON, it will return to the ON state after power interruptions. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count value. Dual Counter Operation Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set value for which output turns ON when the set value matches the added or subtracted result. (1) Dual Count Calculating Mode = ADD Dual count value = CP1 PV + CP2 PV Reset 1 (CP1 reset) Reset 2 (CP2 reset) (2) Dual Count Calculating Mode = SUB Dual count value = CP1 PV − CP2 PV Reset 1 (CP1 reset) Reset 2 (CP2 reset) Dual count set value Dual count set value Dual count value Dual count value 0 0 CP1 present value CP1 present value 0 0 CP2 present value CP2 present value 0 0 OUT1, OUT2 Note: The above is for when the output mode is N. • The operation after count completion for the dual counter value is determined by the output mode. • The CP1 present value is reset when reset 1 input is turned ON. The CP2 present value is reset when reset 2 input is turned ON. • If the Reset Key is pressed while the dual count value, CP1 present value, or CP2 present value is displayed, all of the present values are reset and outputs turn OFF. At this time, counting is not possible for CP1 or CP2 inputs. OUT1, OUT2 Note: The above is for when the output mode is K-2. SUB mode can be used only when K-2, D, L, or H is selected as the output mode with 6-digit models. Note: 1. Counting is not possible for CP1 during reset 1 input. CP2 will not be affected. The dual count value will be calculated based on a CP1 present value of 0. 2. Counting is not possible for CP2 during reset 2 input. CP1 will not be affected. The dual count value will be calculated based on a CP2 present value of 0. 3. The counting range for the dual count value is −99,999 to 999,999 (0 to 9,999 for 4-digit models). The counting ranges for the CP1 present value and CP2 present value are 0 to 999,999 (0 to 9,999 for 4-digit models). If a present value exceeds 999,999 (9,999 for 4-digit models), FFFFFF (FFFF for 4-digit models) will be displayed to indicate an overflow, and all counting will stop. 25 H7CX-A@-N Counter Twin Counter Operation Two independent counters are built in. Counter 1 Counter input Reset input Counter 2 CP1 CP2 Reset 1 Reset 2 Counter 1 display Counter 2 display Counter 1 present value Counter 2 present value Present value display and setting Switched with the Key. Counter 1 set value Reset Key Counter 2 set value Only counters appearing on the display will be reset. Note: 1. Only 2-stage models 2. Increment mode only for counters 1 and 2. 3. The settings for prescaling and the decimal point are used by both counter 1 and 2. Reset Function List I/O Functions for Counter Operation Function 1-stage/2stage preset counter Total and preset counter Batch count value/batch count set value Dual count value/dual count set value Twin counter CP1 present value/CP2 present value Present value/ set value (1, 2) Reset/reset 1 Present value and output reset. Present value and output reset. Present value and output reset. Only the CP1 present value is reset. Only the CP1 present value is reset. Total reset or reset 2 No effect Only the total count value is reset. Batch count value and batch output reset. Only the CP2 present value is reset. Only the CP2 present value is reset. Reset Key Present value and output reset. Present value/set value Dual counter Screen displayed in run mode Present value and output reset. Present value/set value Batch counter Total count value Present value, total count value, and output reset. Present value and output reset. Present value, batch count value, output and batch output reset. Present value 1/Set value 1 CP1 present value, CP2 present value, dual count value, and output reset. • The following table shows the delay from when the present value passes the set value until the output is produced. Actual measurements in N and K-2 modes (Reference values) Control output type Contact output Transistor output Max. counting speed Output delay time 30 Hz 16.5 to 24.0 ms 5 kHz 3.7 to 5.6 ms 30 Hz 12.0 to 20.0 ms 5 kHz 0.2 to 0.55 ms Note: The above times may vary slightly depending on the mode or operating conditions. 26 CP1 present value reset Present value 2/Set value 2 CP2 present value reset H7CX-A@-N Tachometer Setting Procedure Guide Tachometer Operation Step1 The H7CX is factory-set to the 2-stage counter configuration (1-stage counter configuration for H7CX-AU@-N models). Enter configuration selection mode using the following chart and set the tachometer mode. Note: Step2 can be performed first, followed by Step1 . Configuration selection mode Power ON 1 + Hold down for 1 s min. Switch from 2cnt (2-stage preset counter mode) to taco (tachometer mode) using the U Key. Run mode 1 + Hold down for 1 s min. Step2 Set the basic parameters. (If the desired I/O mode is not listed below or to set all parameters using the front panel keys, perform Step3 , below.) Key-protect switch Be sure to set pin 1 to ON. ON OFF Item 1 DIP switch settings 2 Counting speed 3 4 5 6 7 8 OFF ON Pin 3 Pin 4 Tachometer output mode Disabled Enabled OFF OFF Upper/lower limit output 30 Hz 10 kHz ON OFF Range output OFF ON Upper limit output ON ON Lower limit output Average processing Tachometer output mode Refer to the table on the right. Average processing Refer to the table on the right. --Input selection Note: All pins are factory-set to OFF. 1 2 3 4 5 6 7 8 Pin 5 Pin 6 --- --- OFF OFF OFF NPN PNP ON OFF 2 times OFF ON 4 times ON ON 8 times • When setting functions using the DIP switch, be sure to set pin 1 of the DIP switch to ON. • DIP switch settings are effective when the power is turned ON again. (Perform DIP switch settings while the power is OFF.) After making DIP switch settings for basic operations, advanced functions can be added using the operation keys. For details, refer to page page 28. 27 H7CX-A@-N Tachometer Step3 Parameters that cannot be set with the DIP switch are set with the operation keys on the front panel. Change to Function Setting Mode. For details on operations and display in run mode, refer to page page 33. Power ON 3 s min.*1 Function setting mode Run mode 3 s min.*2 *1 If the mode is switched to the function setting mode during operation, operation will continue. *2 Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is reset (measured value initialized and outputs turned OFF) on returning to run mode. The characters displayed in reverse video are the default settings. When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed. Tachometer input mode (TINM) • Set the tachometer input mode using the U Key. f1 f2 f3 f4 *1 Set tachometer output modes 1 and 2 using the U Key. f5 (1 input) (2 inputs) (Error) (Absolute ratio) (Error ratio) * Displayed only when the tachometer input mode is F2 (2 inputs). *1 Tachometer output mode (TOTM) Counting speed (CNTS) Tachometer output mode 1 (TO1M) • Set the tachometer output mode using the U Key. hilo area hihi lolo (HI-LO) (AREA) (HI-HI) (LO-LO) Tachometer output mode 2 (TO2M) • Set the counting speed using the U Key. 30hz (30 Hz) hi lo (HI) (LO) hi lo (HI) (LO) (10 kHz) Note: Even if 10 kHz is selected when the tachometer input mode is F2 to F5, the counting speed will be 5 kHz. Function Setting Mode Decimal point position (DP) • Set the decimal point position using the U Key. --.---(No decimal point) (One digit after decimal point) (Two digits after (Three digits after (Four digits after decimal point) decimal point) decimal point) Note: “--.----“ will be displayed when pulse width measurement is set or when the display unit is set to seconds. Prescale value (PSCL) Averaging method (AVGT) • Set each digit using the individual U Key. 0.001 1.000 99.999 (0.001) (1.000) (99.999) • Set the averaging method using the U Key. smp mv (Simple (Moving averaging) average) Average processing (AVGN) • Set the number of averaging times using the U Key. off 2 4 8 16 (No average (Average of 2 (Average of 4 (Average of 8 (Average of 16 processing) measurements) measurements) measurements) measurements) Auto-zero time (AUT00) Startup time (STMR) From next page To next page 28 • Set each digit using the individual U Key. 0.1 999.9 (0.1 s) (999.9 s) • Set each digit using the individual U Key. 0.0 99.9 (0.0 s) (99.9 s) H7CX-A@-N Tachometer To previous page From previous page NPN/PNP input mode (IMOD) • Set the NPN/PNP input mode using the U Key. npn pnp (NPN input) (PNP input) Display color (COLR) • Set the display color using the U Key. red (Red) Peak/bottom hold enabled (DHLD) grn org r-g g-r r-o o-r g-o o-g (Green) (Orange) (Red-green) (Green-red) (Red-orange) (Orange-red) (Green-orange) (Orange-green) • Enable or disable the peak/bottom hold using the U Key. off on (Disabled) (Enabled) Output hysteresis (HYS) • Set the output hysteresis using the U Key. 0 99999 (0) (99999) Note: The measurement value after prescaling is set. Function Setting Mode Output OFF delay (OFFD) • Set each digit using the individual U Key. 0.00 (0.00 s) Set value upper limit (SL-H) Output allocation change 19.99 (19.99 s) • Set each digit using the individual U Key. 1 999999 (1) (999999) off on (OFF) (ON) Note: Displayed only for "-AU@" models. off: Output 1 = 12, 13, Output 2 = 3, 4, 5 on: Output 1 = 3, 4, 5, Output 2 = 12, 13 The numbers are the terminals numbers. Key protect level (KYPT) Pulse cycle measurement/ pulse width measurement (CALM) Display unit (UNIT) • Set the key protect level using the U Key. kp-1 kp-2 kp-3 kp-4 kp-5 kp-6 kp-7 (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) (KP-6) (KP-7) • Set pulse cycle measurement or pulse width measurement using the U Key. phas (Pulse cycle (Pulse width measurement) measurement) • Set the display unit using the U Key. hz s *2 Set each digit using the individual U Keys. Output 1 (OUT1) ON count alarm set value 0 9999 0 9999 (0 × 1000 times) (9999 × 1000 times) (Hz) (s) Note: Displayed only when pulse cycle measurement is used. Measurement interval (INTV) • Set each digit using the individual U Key. 200ms Output 2 (OUT2) ON count alarm set value cont (0 × 1000 times) (9999 × 1000 times) (200 ms) (Cont (10 ms min.)) Note: Displayed only if the measurement speed is 10 kHz when pulse cycle measurement is used. *2 Output ON count alarm set value/monitor value Output 1 (OUT1) ON count monitor value Note: The monitor value is only displayed. It cannot be set. Output 2 (OUT2) ON Note: The monitor value is only count displayed. It cannot be set. monitor value 29 H7CX-A@-N Tachometer Explanation of Functions Tachometer Operation Items marked with stars ★ can be set using the DIP switch. Tachometer Input Mode (tinm) Set the count input mode to one of the following: 1 input (F1), 2 inputs (F2), error (F3), absolute ratio (F4), or error ratio (F5). Input mode Internal processing Input Application 1 input Count 1 None Operation with only one input. 2 inputs Counts 1 and 2 None Error Counts 1 and 2 Count 1 input − Count 2 input Measuring the difference between two inputs (error in number of revolutions). Absolute ratio Counts 1 and 2 Count 1 input ÷ Count 2 input Measuring the ratio of two inputs (ratio of number of revolutions). Operation with two independent inputs. Measuring the ratio of error for two inputs (measuring the error ratio of number of revolutions). (Count 1 input − Error ratio Counts 1 and 2 Count 2 input) ÷ Count 2 input Tachometer Output Mode (totm)★ Set the output method for control output based on the comparison value. Upper and lower limit (HI-LO), area (AREA), upper limit (HI-HI), and lower limit (LO-LO) can be set. (For details on the output modes, refer to Output Mode Settings and Operation on page page 34.) N: Number of pulses per revolution d: Diameter of rotating body (m) πd: Circumference (m) d: Diameter of rotating body (m) • Observe the following points when setting a prescale value. Set the set value to a value less than {Maximum countable value − Prescale value}. Example: If the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 − 1.25). If the set value is set to a value greater than this, output will not turn ON. * Output will turn ON, however, if a present value overflow occurs (FFFFFF or FFFF}. Note: If the prescale value setting is incorrect, a counting error will occur. Check that the settings are correct before using this function. Averaging Method (avgt) (Only for Tachometer Operation) A simple average or moving average can be selected for the averaging. With the moving average method, the average of the measurement values is displayed each sampling cycle, in contrast to a simple average, with which the the average of the set number of samples is displayed. Number of Averaging Times (avgn)★ Decide the decimal point position for the measurement value, OUT1 set value, and OUT2 set value. Flickering display and output chattering can be prevented using average processing. Average processing can be set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 times, 8 times, or 16 times. The measurement cycle will be equal to the sampling cycle multiplied by the average processing setting (i.e., the number of times). Average processing enables stable displays even for fluctuating input signals. Set the optimum number of times for the application. Prescale Value (pscl) Auto-zero Time (auto0) Counting Speed (cnts)★ Set the maximum counting speed (30 Hz/10 kHz) for CP1 input. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. Decimal Point Position (dp) It is possible to display the rate of rotation or the speed of a device or machine to which the H7CX is mounted by converting input pulses to a desired unit. If this prescaling function is not used, the input frequency (Hz) will be displayed. It is also possible to specify time (seconds) as the display value. Refer to Display Unit on page page 31 for details. The relationship between display and input is determined by the following equation. Set the prescale value according to the unit to be displayed. Displayed value = f × α f: Input pulse frequency (number of pulses in 1 second) α: Prescale value (1) Displaying Rotation Rate Display unit Prescale value (α) rpm 1/N × 60 rps 1/N The display can be force-set to 0 if there is no pulse for a certain period of time. This time is called the auto-zero time. Set the auto-zero time to a time slightly longer than the estimated interval between input pulses. Accurate measurement is not possible if the auto-zero time is set to a time shorter than the input pulse cycle. Setting a time that is too long may also result in problems, such as a time-lag between rotation stopping and the alarm turning ON. The auto-zero time is not applied to pulse width measurements. Startup Time (stmr) To prevent undesired outputs resulting from unstable inputs immediately after the power supply is turned ON, it is possible to prohibit measurement for a set period of time, the startup time. It can also be used to stop measurements and disable outputs until the rotating body reaches the normal rate of rotation, after the power supply to the H7CX and rotating body are turned ON at the same time. Display Startup time Comparison value (lower limit) N: Number of pulses per revolution Example: To display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@.@ rpm: 1. Set the decimal point position to 1 decimal places. 2. Using the formula, set the prescale value (α) to 1/N × 60 = 60/5 = 12. (2) Displaying Speed 30 Display unit Prescale value (α) m/min πd × 1/N × 60 m/s πd × 1/N Time Power supply Output (lower limit) H7CX-A@-N Tachometer NPN/PNP Input Mode (imod)★ Output Hysteresis (hys) Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. When using a two-wire sensor, select NPN input. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page page 9. This setting can be used to prevent output chattering if the measurement value fluctuates slightly near the set value. The measurement value after prescaling is set. Comparison value 2 Hysteresis Display value Display Color (colr) Control output OFF Hysteresis Comparison value 1 Set the color used for the measurement value. Control output ON OUTX1 red Red (fixed) grn Green (fixed) org Orange (fixed) r-g *1 Measured value is displayed in red when both control outputs 1 and 2 are OFF. Measured value is displayed in green when either control output 1 or control output 2 is ON. g-r *2 Measured value is displayed in green when both control outputs 1 and 2 are OFF. Measured value is displayed in red when either control output 1 or control output 2 is ON. r-o *3 Measured value is displayed in red when both control outputs 1 and 2 are OFF. Measured value is displayed in orange when both control outputs 1 and 2 are OFF. o-r *4 Measured value is displayed in orange when both control outputs 1 and 2 are OFF. Measured value is displayed in red when both control outputs 1 and 2 are OFF. g-o *5 Measured value is displayed in green when both control outputs 1 and 2 are OFF. Measured value is displayed in orange when both control outputs 1 and 2 are OFF. o-g *6 Measured value is displayed in orange when both control outputs 1 and 2 are OFF. Measured value is displayed in green when both control outputs 1 and 2 are OFF. *1. If the tachometer output mode is set to AREA, however, the measured value is displayed in red when control output 1 is OFF and in green when control output 1 is ON. *2. If the tachometer output mode is set to AREA, however, the measured value is displayed in green when control output 1 is OFF and in red when control output 1 is ON. *3. If the tachometer output mode is set to AREA, however, the measured value is displayed in red when control output 1 is OFF and in orange when control output 1 is ON. *4. If the tachometer output mode is set to AREA, however, the measured value is displayed in orange when control output 1 is OFF and in red when control output 1 is ON. *5. If the tachometer output mode is set to AREA, however, the measured value is displayed in green when control output 1 is OFF and in orange when control output 1 is ON. *6. If the tachometer output mode is set to AREA, however, the measured value is displayed in orange when control output 1 is OFF and in green when control output 1 is ON. Peak/bottom Hold Enabled (dhld) This function records the peak and bottom (i.e., minimum) after counting starts (after turning ON the power supply or changing the configuration selection mode or function setting). The peak value is also held when the power supply is interrupted. OUTY2 Set the hysteresis for when the output turns OFF. Output OFF Delay (offd) This function delays the timing for turning OFF comparative output by a certain time. The ON time can be held for the set time if the comparative result changes in a short time. Operation will continue and outputs will not change when holding the value. Set Value Upper Limit (pl-h) Set the upper limit for the set value when it is set in run mode. The limit can be set to between 1 and 999999. Output Allocation (otst) When using an H7CX-AU@-N model as 2-stage counter, each output can be flexibly allocated to either stage 1 or 2. The transistor output can be allocated to SV1 and the contact output to SV2 or vice verse, as in the following tables. H7CX-AU-N/-AUD1-N Output 1 Output 2 off Transistor (12-13) Contact (3, 4, 5) on Contact (3, 4, 5) Transistor (12-13) H7CX-AUSD1-N Output 1 Output 2 off Transistor (12-13) Transistor with diode (3, 4, 5) on Transistor with diode (3, 4, 5) Transistor (12-13) Key Protect Level (kypt) Set the key protect level. Refer to Key Protect Level on page page 36. Pulse Cycle Measurement/Pulse Width Measurement (calm) Set the measurement mode to pulse cycle measurement or pulse width measurement. With pulse cycle measurement, the number of pulse cycles that occur in 1 s is measured. With pulse width measurement, the ON time for one pulse is measured. An input OFF period of at least 20 ms is required for pulse width measurement. If there is no input pulse during pulse width measurement, the previously measured value will be held. Display Unit (unit) When pulse cycle measurement is used, set the display unit to Hz (hertz) or s (seconds). Counting Interval (intv) If the measurement speed is 10 kHz when pulse cycle measurement is used, set the measurement interval to 200 ms or Cont (10 ms min.). 31 H7CX-A@-N Tachometer ON Count Alarm Set Values for Outputs 1 and 2 (OUT1 and OUT2) (on1a and on2a) Set the ON count alarm values for the outputs 1 and 2. The limit can be set to between 0 × 1000 (0 times) and 9999 × 1000 (9,999,000 times). Only the underlined values are set. The alarm will be disabled if 0 is set. If the total ON count of instantaneous output 1 or 2 exceeds the alarm set value, e3 will be displayed on the Timer to indicate that the output ON count alarm value was exceeded. Refer to Self-diagnostic Function on page page 36 for information on the e3 display. ON Count Monitor Values for Outputs 1 and 2 (OUT1 and OUT2) (on1c and on2c) The monitor value for output 1 or 2 is only displayed. It cannot be set. The output ON count will be 1,000 times the displayed value. 32 H7CX-A@-N Tachometer Operation in Run Mode Tachometer Operation • Set each digit using the individual U Keys. Measurement value • Measurement value Displays the currently measured value. • Comparison value 1/Comparison value 2 Set comparison value 1 and comparison value 2. Measurement value 1 The measurement value is compared to comparison value 1 and comparison value 2 and Comparison value 1 output is made according to the selected output mode. *1 *2 Measurement value 2 Comparison value 2 *3 *1 Measurement value 1 for the 2-input input mode. *2 Measurement value 2 for the 2-input input mode. *3 Peak/bottom hold enabled Displayed when the input mode is not 2 inputs. Peak hold value Bottom hold value Displayed for the 2-input input mode. Peak hold value 1 Bottom hold value 1 Peak hold value 2 • Peak/bottom hold value The peak (maximum) and bottom (minimum) values are displayed after counting starts. • Peak/bottom hold value 2 Peaks (maximums) 1 and 2 and bottoms (minimums) 1 and 2 are displayed after counting starts. Note: The held values will be initialized when the Reset Key (Hold Key) or reset 1 input is turned OFF while peak/bottom hold values 1 and 2 are being displayed. (The reset 2 input operates in the same way if the input mode is set to 2-input mode.) Bottom hold value 2 33 H7CX-A@-N Output Mode Setting and Operation Tachometer Operation Input mode setting Output mode setting Operation (Upper-limit) Comparison value 2 Measurement value Upper and lower limit (HI-LO) (Lower-limit) Comparison value 1 ON condition for OUT1: Measurement value ≤ Comparison value 1 ON condition for OUT2: Measurement value ≥ Comparison value 2 OUT1 OUT2 Comparison value 2 Measurement value Area (AREA) Comparison value 1 OUT1 1 input Error Absolute ratio Error ratio Comparison value 1 ≤ Comparison value 2 Condition Measurement value 1 > Comparison value 2 ON condition for OUT1 Comparison value 1 ≤ Measurement value ≤ Comparison value 2 Comparison value 2 ≤ Measurement value ≤ Comparison value 1 ON condition for OUT2 Measurement value < Comparison value 1 or Measurement value > Comparison value 2 Measurement value < Comparison value 2 or Measurement value > Comparison value 1 OUT2 (Upper-limit) Comparison value 2 Measurement value Upper limit (HI-HI) (Lower-limit) Comparison value 1 ON condition for OUT1: Measurement value ≥ Comparison value 1 ON condition for OUT2: Measurement value ≥ Comparison value 2 OUT1 OUT2 (Upper-limit) Comparison value 2 Measurement value Lower limit (LO-LO) (Lower-limit) Comparison value 1 ON condition for OUT1: Measurement value ≤ Comparison value 1 ON condition for OUT2: Measurement value ≤ Comparison value 2 OUT1 OUT2 Output 1 Output 2 Comparison value 1 Comparison value 2 CP1 display value CP2 display value Upper limit (HI) OUT1 OUT2 ON condition for output 1: CP1 present value (display value) ≥ Comparison value 1 ON condition for output 2: CP2 present value (display value) ≥ Comparison value 2 2 inputs Output 1 Output 2 CP1 display value Lower limit (LO) CP2 display value Comparison value 1 Comparison value 2 OUT1 OUT2 ON condition for output 1: CP1 present value (display value) ≤ Comparison value 1 ON condition for output 2: CP2 present value (display value) ≤ Comparison value 2 34 H7CX-A@-N Switching between Preset Counter, Total and Preset Counter, Batch Counter, Dual Counter, Twin Counter, and Tachometer Operation Select which H7CX configuration is used (i.e., preset counter, total and preset counter, batch counter, dual counter, twin counter, or tachometer) in configuration selection mode. The H7CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the display on the front of the H7CX. Power ON Run mode RST 1 Key Key Key 1 Key Note Configuration Selection Mode *2 To change the mode to configuration selection mode, hold down the Key held down. 1 Key for 1 s min. with the 1 Key is pressed first. The mode will not change if the + 1 *1 Press the key for 1 s min. Configuration selection Select the configuration using the UD Key. 1cnt (1-stage preset counter) 2cnt tcnt bcnt (Batch (Total and preset counter) counter) (2-stage preset counter) dcnt (Dual counter) twn (Twin counter) taco (Tachometer) *The configurations that can be selected depend on the model. Note: By default, the H7CX is set to the 1-stage preset counter configuration. (Two-stage models are set to the 2-stage preset counter configuration.) nt ie ven Con DIP switch monitor (DIP) Confirm the status of DIP switch pins 1 to 8 using the UD Key. *This display is possible only when DIP switch pin 1 (DIP switch settings enable/disable) is set to ON (enable). Example ON OFF 1 2 3 4 5 6 7 8 …Indicates that DIP switch pin 8 is ON. …Indicates that DIP switch pin 7 is OFF. …Indicates that DIP switch pin 6 is ON. …Indicates that DIP switch pin 5 is OFF. …Indicates that DIP switch pin 4 is ON. …Indicates that DIP switch pin 3 is OFF. …Indicates that DIP switch pin 2 is ON. …Indicates that DIP switch pin 1 is ON. *1 When the mode is changed to configuration selection mode, the present value is reset, outputs turn OFF, and counting (measuring) stops. *2 Setting changes made in configuration selection mode are enabled when the mode is changed to run mode. If the configuration is changed, the set value (or set value 1 and set value 2), comparison value 1 and comparison value 2 are initialized. Hold Function The measurement value (display value) and output are sustained while the hold input is ON. Note: The output will maintain the current status when the hold key is pressed. Example: Output mode setting Operation Hold input* (Reset Key) Actual input Display value Lower limit Comparison value (lower limit) Sustained display value Sustained output OUT 35 H7CX-A@-N Key Protect Level It is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-7) when the key-protect switch is set to ON. The key protect level is set in the function setting mode. The key protect indicator is lit when the key-protect switch is ON. * OFF (Disable) ON (Enable) *Factory-set to OFF Key protect indicator Details Level Description Changing modes* Switching display during operation Reset Key Up/Down Keys KP-1 (default setting) Invalid Valid Valid Valid KP-2 Invalid Valid Invalid Valid KP-3 Invalid Valid Valid Invalid KP-4 Invalid Valid Invalid Invalid KP-5 Invalid Invalid Invalid Invalid KP-6 Invalid Invalid Valid Valid KP-7 Invalid Invalid Invalid Valid * Changing mode to configuration selection mode or function setting mode. Self-diagnostic Function The following displays will appear if an error occurs. Main display Sub-display Output status Correction method Set value after reset ----- (----)*1*5 No change Present value underflow*3 Description No change Either press the Reset Key or turn ON reset input. No change fffff (ffff)*1*5 No change Present value overflow*4 No change Either press the Reset Key or turn ON reset input.*6 No change e1 Not lit Either press the Reset Key or reset the power supply. No change e2 Not lit e2 sum e3*8 No change CPU error Memory error (RAM) OFF Turn ON the power again. Memory error (EEPROM)*2 OFF Reset Key Output Counter Overflow *1. Displays for 4-digit models are given in parentheses. *2. This includes times when the life of the EEPROM has expired. *3. This occurs if the present value or total count value falls below −99999 (−999 for 4-digit models). *4. This occurs in the following conditions if the present value (i.e., measurement value) exceeds 999999 (9999 for 4-digit models). • For Output Modes K-2, D, L, or H • Dual counter or tachometer operation is used. *5. Display flashes.(1-second cycles) *6. This does not apply when tachometer operation is used. 36 OFF No change Reset Key*7 No change Factory setting No change *7. This is displayed if the alarm value setting for either of the two outputs is exceeded if a model with two outputs is used.The total ON count will not be cleared by using the Reset Key. *8. The normal display and e3 will appear alternately. When the Reset Key is pressed, e3 will not be displayed even if the alarm set value is exceeded. (Monitoring is possible, however, because the counter will continue without the output ON count being cleared.) H7CX-R@-N H7CX-R@-N Tachometer • Tachometer-only model (DIN 48 × 48) for the H7CX (Supports display and alarm outputs for numbers of rotations, speed, and flow rate.) • Socket design allows either flush or surface mounting. • “-W” models added for control with two independent measurements. • Operation in any of the four following modes is possible with the same Unit: Upper and lower limit, upper limit, lower limit, and area. • Equipped with auto-zero time, average processing, and startup time functions. Specifications Ratings Item Input mode Classification Model Power supply voltage*1 Operating voltRatings age fluctuation range Power consumption Mounting method External connections Degree of protection Input signals Tachometer H7CX-R11@-N 1 input only • 100 to 240 VAC, 50/60 Hz • 12 to 24 VDC or 24 VAC, 50/60 Hz H7CX-R11W@-N 2 inputs only 85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC) Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx. 3.7 W at 12 to 24 VDC Flush mounting or surface mounting 11-pin socket IEC IP66, UL508 Type 4 (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used Count and hold Count 1 and count 2 AMD-compatible mode (continuous Pulse measurement method Tachometer mode (cycle measurement) Tachometer mode (cycle measurement) measurement) Maximum counting speed 30 Hz 10 kHz --5 kHz Minimum input signal width --10 ms 1 ms --Measuring ranges 0.01 Hz to 30.00Hz 0.01 Hz to 10 kHz 0.026 to 999999 s 0.003 to 999999 s 0.01 to 5k Hz Continuous measurement (minimum Sampling cycle 200 ms min. 200 ms min. interval of 10 ms) • Input pulse of 5 Hz min. Averaging not used: 200 ms Averaging used: 200 multiplied by the averaging setting (ms) Display refresh cycle • Input pulse of less than 5 Hz Using averaging: Two times the maximum input pulse cycle Using averaging: Two times the maximum of the input pulse cycle multiplied by the averaging setting. Measuring accuracy ±0.1% FS ±1 digit max. (at 23 ±5°C) Output mode HI-LO, AREA, HI-HI, LO-LO HI-HI, LO-LO Auto-zero time 0.1 to 999.9 s (in Tachometer Mode) Startup time 0.0 to 99.9 s Averaging Simple averaging/moving averaging selectable, Number of times: OFF, 2, 4, or 8 times Prescaling function 0.001 to 99.999 (in Tachometer Mode) Decimal point adjustment Rightmost 3 digits --Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) No-voltage Input Impedance when ON: 1 kΩ max. (Leakage current: 12 mA when 0 Ω) ON residual voltage: 3 V max. Impedance when OFF: 100 kΩ min. Input method Voltage Input Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) No-voltage input/voltage input (switchable) Hold input Minimum input signal width: 20 ms --12 VDC (±10%), 100 mA External power supply * Refer to Safety Precautions (Common) on page page 52 for details. Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Control output Minimum applied load:10 mA at 5 VDC (failure level: P, reference value) 7-segment, negative transmissive LCD Display*2 Character height Present value: 10 mm (red), comparison value: 6 mm (green) Digits 6 digits (0 to 999999) Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Operating temperature range −10 to 55°C (−10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation) Storage temperature range −25 to 70°C (with no icing or condensation) Operating humidity range 25% to 85% Case color Black (N1.5) *1. Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for CC power. *2. The display is lit only when the power is ON. Nothing is displayed when power is OFF. 37 H7CX-R@-N Characteristics * See Life-test Curve (Reference Values) on the right. Life-test Curve (Reference Values) No. of operations ( ×103) Resistive Load 1,000 700 500 300 30 VDC (cosφ=1) 250 VAC (cosφ=1) 100 70 50 0 1 2 3 4 Load current (A) Inductive Load No. of operations ( ×103) 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed noncurrent-carrying metal parts, and between non-continuous contacts 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-currentcarrying metal parts 2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input Dielectric strength circuit (1,000 VAC for 24 VAC/12 to 24 VDC) 2,000 VAC 50/60 Hz for 1 min between control output, power supply, and input circuit 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts 3.0 kV (between power terminals) for 100 to 240 VAC, 1.0 kV for 24 VAC/12 to 24 VDC Impulse withstand voltage 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 1.5 kV for 24 VAC/12 to 24 VDC ±1.5 kV (between power terminals) Noise immunity ±600 V (between input terminals) Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Destruction: 15 kV, Malfunction: 8 kV Destruction 10 to 55 Hz with 0.75-mm single amplitude, each in three directions for 2 hours Vibration resistance Malfunction 10 to 55 Hz with 0.35-mm single amplitude, each in three directions for 10 min Destruction 300m/s2 each in three directions, three cycles Shock resistance Malfunction 100m/s2 each in three directions, three cycles Mechanical: 10,000,000 operations min. Life expectancy Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature condition: 23°C) * Weight Approx. 110 g (Tachometer only) Insulation resistance 1,000 700 500 300 30 VDC (L/R=7 ms) Applicable Standards Approved safety standards EMC cULus (or cURus): UL508/CSA C22.2 No. 14* Conforms to EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II, B300 PILOT DUTY, 1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3-A resistive load EN61326 (EMI) EN55011 Group 1 classA Emission Enclosure: EN55011 Group 1 classA Emission AC mains: EN61326 (EMS) EN61000-4-2: 4 kV contact discharge (level 2); Immunity ESD: 8 kV air discharge (level 3) EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) Immunity RF-interference: (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) EN61000-4-4: 2 kV power-line (level 3); Immunity Burst: 1 kV I/O signal-line (level 4) EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); Immunity Surge: 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) * The following safety standards apply to the H7CX-R11@. cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used. cUR (Recognition): Applicable when any other socket is used. I/O Functions Inputs Count, count 1, count 2 Hold Outputs OUT Reads counting signals. • Holds the measurement value and outputs. • The hold indicator is lit during hold.* Outputs signals according to the specified output mode when a comparison value is reached. * Refer to page page 50 for details on the hold function. • The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values) 38 Minimum reset signal width Output delay time 1 ms 0.8 to 1.2 ms 20 ms 15 to 25 ms 100 250 VAC (cosφ=1) 70 50 0 1 2 3 4 Load current (A) A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) (Life expectancy: 100,000 operations) A current of 0.1 A max. can be switched if L/R=7 ms. (Life expectancy: 100,000 operations) H7CX-R@-N Connections Terminal Arrangement Block Diagram H7CX-R11-N H7CX-R11D1-N (Basic insulation) Output circuit * Hold Power supply circuit (Basic insulation) (Basic insulation) Count * * Hold Hold 0V (−) Sensor (+) Display circuit Internal circuit 6 5 4 8 3 9 10 2 1 11 12 VDC External power supply OUT (+) (−) * The hold function is the same whichever terminal is connected. Terminals are not connected internally, and so do not use them for cross-over wiring. H7CX-R11W-N H7CX-R11WD1-N Count and Hold Inputs No-voltage Inputs (NPN Inputs) Count 2 Internal circuit 5 6 7 4 0V (+) Approx. 4.7 kΩ 1 kΩ IN IN Internal circuit Internal circuit 8 3 2 12 VDC Voltage Inputs (PNP Inputs) +14V OUT2 Count 1 Key switch circuit Input Circuits Internal circuit (−) Sensor Internal control circuit Input circuits 7 1 11 9 10 External power supply OUT1 (−) (+) Transistor Output • The transistor output of the H7CX is isolated from the internal circuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. NPN Output PNP Output Load Load + + Power for load Power for load • The diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the H7CX. Counter + Inductive load Power for load 39 H7CX-R@-N Input Connections The inputs of the H7CX-R are no-voltage (short-circuit or open) inputs or voltage inputs. They are set for use as voltage inputs at the time of delivery. No-voltage Inputs (NPN Inputs) Count Hold Hold Count 0 V for inputs DC Two-wire Sensor 0 V for inputs Hold Count Hold Contact Input Count Sensor, etc. 0 V for inputs Voltage Output PLC or sensor 0 V for inputs Open Collector H7CX-R11@ 3 4 5 7 6 H7CX-R11@ 3 4 5 7 6 H7CX-R11@ 3 4 5 7 6 H7CX-R11@ 3 4 5 7 6 H7CX-R11W@ 3 --- 6 H7CX-R11W@ 3 --- 6 H7CX-R11W@ 3 --- 6 H7CX-R11W@ 3 --- 6 Note: Operates when the transistor turns ON. Note: Operate when the contact turns ON. Note: Operates when the transistor turns ON. Note: Operates when the transistor turns ON. No-voltage Input Signal Levels No-contact input Short-circuit level (Transistor ON) • Residual voltage: 3 V max. • Impedance when ON: 1 kΩ max. Applicable Two-wire Sensor • • • • (The leakage current is approx. 12 mA when the impedance is 0 Ω.) Open level (Transistor OFF) • Impedance when OFF: 100 kΩ min. Contact input Leakage current: 1.5 mA max. Switching capacity: 5 mA min. Residual voltage: 3 VDC max. Operating voltage: 10 VDC Use contacts which can adequately switch 5 mA at 10 V. Note: The DC voltage must be 30 VDC max. Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) Sensor, etc. 3 6 H7CX-R11@ 3 4 5 7 6 H7CX-R11W@ 3 --- 6 Note: Operate when the transistor turns ON. Voltage Input Signal Levels High level (Input ON): 4.5 to 30 VDC Low level (Input OFF): 0 to 2 VDC Note: 1. The DC voltage must be 30 VDC max. 2. Input resistance: Approx. 4.7 kΩ H7CX-R11@ 3 Count Hold 0 V for inputs Count Hold 0 V for inputs Count Hold 4 5 7 3 --6 H7CX-R11W@ Note: Operate when the transistor turns OFF. 40 Contact Input Sensor, etc. 0 V for inputs H7CX-R11@ No-contact Input (PNP Transistor) 4 5 7 6 3 --6 H7CX-R11W@ Note: Operate when the contact turns ON. H7CX-R@-N Nomenclature Display Section Operation Keys 1. Hold Indicator (orange) 7. Mode Key (Lit when the hold input or hold key is ON. ) (Used to switch mode and setting items.) 5 2 2. Key Protect Indicator (orange) 3 1 Lit when the key protect switch is ON. 6 8. Hold Key (Used to sustain the measurement value and output.) 4 3. Control Output Indicator (orange) OUT 1 9. Up Keys 1 to 6 7 OUT (1-output models) 9 8 2 (2-output models) Switches 4. Comparison Value 1, 2 Stage Indicator 6th digit 1st digit 10. Key-protect Switch 5. Present Value (Main Display) (Factory setting) OFF (Disable) Character height: 10 mm (red) 10 ON (Enable) 11 6. Comparison Value (Sub-display) Character height: 6 mm (green) Character Size for Main Display 11. DIP Switch Character Size for Sub-display ON 6 mm 10 mm OFF 1 2 3 4 5 6 7 8 (Factory setting) Dimensions (Unit: mm) Tachometers Dimensions without Flush Mounting Adapter Panel Cutouts Panel cutouts are as shown below (according to DIN43700). H7CX-R@-N 60 min. 45 +0.6 −0 48 × 48 6 63.7 14.4 45 +0.6 −0 15 min. 60 min. 44.8 × 44.8 Note: Dimensions with Flush Mounting Adapter (Adapter and Waterproof Packing Ordered Separately) Y92S-29 (order separately) Waterproof Packing Panel H7CX-R@-N 1. 2. 3. Y92F-30 (order separately) Flush Mounting Adapter The mounting panel thickness should be 1 to 5 mm. To allow easier operation, it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm (i.e., with the panel cutouts separated by at least 60 mm). It is possible to mount counters side by side, but only in the direction without the hooks. If Counters/ Tachometers are mounted side by side, however, water resistance will be lost. n side by side mounting P3GA-11 (order separately) Rear Surface Connection Socket (51) 58 48 7.5 A A=(48n−2.5) +1 −0 With Y92A-48F1 attached. A={48n−2.5+(n−1)×4} +1 −0 With Y92A-48 attached. A=(51n−5.5) +1 −0 89.9 Dimensions with Front Connecting Socket P2CF-11(-E) (order separately) Front Connecting Socket H7CX-R@-N H7CX-R@-N 100.9 103.2* * These dimensions vary with the kind of DIN track (reference value). 41 H7CX-R@-N Accessories (Order Separately) Note: Depending on the operating environment, the condition of resin or rubber products may deteriorate, or they may shrink or become harder. Therefore, it is recommended that resin products be replaced regularly. Flush Mounting Adapter Y92F-30 Order a Flush Mounting Adapter separately if the product is to be flush-mounted. Y92F-45 Use this Adapter to install the Counter/Tachometer in a cutout previously made for a DIN 72 × 72 mm device (panel cutout: 68 × 68 mm). Soft Cover Y92A-48F1 Waterproof Packing Y92S-29 Protecting the Timer in Environments Subject to Oil The H7CX's panel surface is water-resistive (conforming to IP@6, UL Type 4X) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54 against oil. Do not, however, use the H7CX in locations where it would come in direct contact with oil. Hard Cover Y92A-48 Connection Sockets Refer to Connection Sockets on page page 13 for details. Optional Products for Track Mounting Refer to Optional Products for Track Mounting on page page 14 for details. 42 Order the Waterproof Packing separately if it is lost or damaged. The Waterproof Packing can be used to achieve protection equivalent to IP66. (The Waterproof Packing will deteriorate, harden, and shrink depending on the application environment. To ensure maintaining the NEMA4 waterproof level, periodically replace the Waterproof Packing. The periodic replacement period will depend on the application environment. You must confirm the proper replacement period. Use 1 year or less as a guideline. If the Waterproof Packing is not replaced periodically, the waterproof level will not be maintained.) It is not necessary to mount the Waterproof Packing if waterproof construction is not required. H7CX-R@-N Operating Procedures Parameters must be set using both the DIP switch and the operation keys on the front panel. Refer to the following for the detailed procedure. Step1 Set the basic parameters. ON OFF 1 2 3 4 5 6 7 8 (Factory setting) Item OFF ON 1 Input mode*1 2 Counting speed/ Minimum input signal width Refer to the table on the right. Output mode*2 Refer to the table on the right. Average processing Refer to the table on the right. 3 4 5 6 7 8 --NPN/PNP input mode --- --- NPN PNP Note: The characters displayed in reverse video are the default settings. The settings made using the DIP switch can be checked in the DIP switch monitor mode. *1. The setting is disabled (OFF) for the H7CX-R11W@. *2. For the H7CX-R11W@. Item OFF ON Input mode Counting speed/ minimum input signal width Pin 1 Pin 2 OFF OFF Tachometer 30 Hz ON OFF AMD compatible 10 ms OFF ON Tachometer 10 kHz*3 ON ON AMD compatible 1 ms Pin 6 Pin 4 Output mode OFF OFF Upper and lower limit ON OFF Area OFF ON Upper limit ON ON Lower limit Pin 5 Pin 6 Average processing OFF OFF OFF (no average processing) ON OFF 2 times OFF ON 4 times ON ON 8 times Pin 3 Output mode 3 Output mode Refer to the table on the right. OFF Upper limit 4 Output mode Refer to the table on the right. ON Lower limit Pin 4 OFF Output mode Upper limit ON Lower limit Note: The characters displayed in reverse video are the default settings. *3. For the H7CX-R11W@, the counting speed will be 5 kHz even if 10 kHz is selected. 43 H7CX-R@-N Step2 For details on operations in run mode, refer to page page 47. Change to Function Setting Mode. Power ON 3 s min.*1 Function setting mode Run mode *1 If the mode is switched to the function setting mode during operation, operation will continue. *2 Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is reset (measured values initialized and output turned OFF) on returning to run mode. 3 s min.*2 The characters displayed in reverse video are the default settings. Decimal point position (DP) • Set the decimal point position using the U Key. (No decimal point) (One digit after (Two digits after (Three digits after decimal point) decimal point) decimal point) Prescale value (PSCL) • Set each digit using the individual U Key. (0.001) (1.000) (99.999) Note: Not displayed in AMD-compatible mode. Averaging method (AUGT) • Set the averaging method using the U Key. Auto-zero time (AUTO0) smp mv (SMP) (MV) *1 Set each digit using the individual U Key. • Set each digit using the individual U Key. Procedure for Models Other than “-R11W@” Models (0.1 s) Output ON count alarm set value (999.9 s) Function Setting Mode Note: Not displayed in AMD-compatible mode. Startup time (STMR) 9999 • Set each digit using the individual U Key. (0.0 s) Peak/bottom hold enabled (DHLD) Output ON count monitor value (99.9 s) Note: The monitor value is only displayed. It cannot be set. • Enable or disable peak/bottom hold using the U Key. Procedure for “-R11W@” Models off Output 1 (OUT1) ON 0 9999 count alarm set value (0 × 1000 times) (9999 × 1000 times) on (Disabled) (Enabled) • Set the output hysteresis using the U Key. Output hysteresis (HYS) 0 (0) Output 2 (OUT2) ON 0 9999 count alarm set value (0 × 1000 times) (9999 × 1000 times) 99999 (99999) Note: The measurement value after prescaling is set. Output OFF delay (OFFD) Set value upper limit (SL-H) • Set each digit using the individual U Key. 0.00 19.99 (0.00 s) (19.99 s) Output 1 (OUT1) ON count Note: The monitor value is only displayed. It cannot be set. monitor value Output 2 (OUT2) ON Note: The monitor value is only count displayed. It cannot be set. monitor value • Set each digit using the individual U Key. 1 (1) Key protect level (KYPT) 999999 (999999) • Set the key protect level using the U Key. kp-1 (KP-1) *1 Output ON count alarm set value/monitor value 44 0 (0 × 1000 times) (9999 × 1000 times) kp-2 (KP-2) kp-3 (KP-3) kp-4 (KP-4) kp-5 (KP-5) kp-6 (KP-6) kp-7 (KP-7) H7CX-R@-N Explanation of Functions Advanced Functions Basic Functions Decimal Point Position (dp) Input Mode The mode can be switched between tachometer mode and AMDcompatible mode. Tachometer Mode Use this mode to measure the pulse frequency (Hz). AMD-compatible Mode Use this mode to measure the pulse cycle (s). Cycle (s) Counting Speed Set the maximum counting speed (30 Hz/10 kHz) for input. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. Output Mode Set the output method for control output based on the comparison value. Upper and lower limit (HI-LO), area (AREA), upper limit (HI), and lower limit (LO) can be set. For the H7CX-RW@, the upper limit (HIHI) and lower limit (LO-LO) can be set. (For details on the operation of the output modes, refer to Output Mode Settings on page page 49.) Averaging Method (avgt) Simple averaging or a moving average can be selected for the averaging method. With a moving average, the average measurement value is displayed every sampling cycle or pulse cycle, in contrast to simple averaging, for which the average value is displayed for the set number of samples. Number of Averaging Times Flickering display and output chattering can be prevented using average processing. Average processing can be set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 times, or 8 times. For a measurement frequency of 5 Hz or higher using a tachometer, the average will be equal to the sampling cycle (200 ms) multiplied by the averaging setting (i.e., the number of times). For less than 5 Hz, the frequency will be measured when the input pulse comes. Average processing produces a stable display even for fluctuating input signals. Set the optimum number of times for the application. If AMD-compatible mode is used, the measurement cycle will be measured when the input pulse is received. The output will change, however, when the comparison value is exceeded even if averaging is enabled. NPN/PNP Input Mode Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. When using a two-wire sensor, select NPN input. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page page 40. Decide the decimal point position for the measurement value and comparison value. Prescale Value (pscl) It is possible to display the rate of rotation or the speed of a device or machine to which the H7CX is mounted by converting input pulses to a desired unit. If the default prescaling value (1,000) is used, the input frequency (Hz) will be displayed. The relationship between display and input is determined by the following equation. Set the prescale value according to the unit to be displayed. Displayed value = f × α f: Input pulse frequency (number of pulses in 1 second) α: Prescale value (1) Displaying Rotation Rate Display unit Prescale value (α) rpm 1/N × 60 rps 1/N N: Number of pulses per revolution Example: In order to display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@.@ rpm: 1. Set the decimal point position to 1 decimal places. 2. Using the formula, set the prescale value (α) to 1/N × 60 = 60/5 = 12. (2) Displaying Speed Display unit Prescale value (α) m/min πd × 1/N × 60 m/s πd × 1/N N: Number of pulses per revolution d: Diameter of rotating body (m) πd: Circumference (m) d: Diameter of rotating body (m) • Observe the following points when setting a prescale value. Set the set value to a value less than {Maximum countable value − Prescale value}. Example: If the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 − 1.25). If the set value is set to a value greater than this, output will not turn ON. Note: If the prescale value setting is incorrect, a counting error will occur. Check that the settings are correct before using this function. Auto-zero Time (auto0) It is possible to make the settings so that the frequency will be forceset to 0 if there is no pulse for a specified period of time. This time is called the auto-zero time. Note: Set the auto-zero time to a time slightly longer than the estimated interval between input pulses. It will not be possible to make accurate measurements if the auto-zero time is set to a time shorter than the input pulse cycle. Setting a time that is too long may also result in problems, such as a time-lag between rotation stopping and the alarm turning ON. 45 H7CX-R@-N Startup Time (stmr) Key Protect Level (ypt) In order to prevent undesired output resulting from unstable input immediately after the power supply is turned ON, measurement can be prohibited for a set time at startup. It can also be used to stop measurement and disable output until the rotating body reaches the normal rate of rotation, after the power supply to the H7CX and rotating body are turned ON at the same time. Set the key protect level. Refer to Key Protect Level on page page 48. Display Startup time Comparison value (lower limit) Output ON Count Alarm Set Value (on-a) Set the alarm value for the output ON count. The limit can be set to between 0 × 1000 (0 times) and 9999 × 1000 (9,999,000 times). Only the underlined values are set. The alarm will be disabled if 0 is set. If the total ON count of the output exceeds the alarm set value, e3 will be displayed on the Timer to indicate that the output ON count alarm value was exceeded. Refer to Self-diagnostic Function on page page 48 for information on the e3 display. Time ON Count Alarm Set Values for Outputs 1 and 2 (OUT1 and OUT2) (on1a and on2a) Power supply This function records the peak and bottom (i.e., minimum) values after counting starts (after turning ON the power supply or changing the configuration selection mode or function setting). The peak value is also held when the power supply is interrupted. Set the ON count alarm values for the outputs 1 and 2. The limit can be set to between 0 × 1000 (0 times) and 9999 × 1000 (9,999,000 times). Only the underlined values are set. The alarm will be disabled if 0 is set. If the total ON count of instantaneous output 1 or 2 exceeds the alarm set value, e3 will be displayed on the Timer to indicate that the output ON count alarm value was exceeded. Refer to Self-diagnostic Function on page page 48 for information on the e3 display. Output Hysteresis (hys) Output ON Count Monitor Value (on-c) This setting can be used to prevent output chattering if the measurement value fluctuates slightly near the set value. In Thachometer Mode, the measurement value after prescaling is set. The monitor value is only displayed. It cannot be set. The output ON count will be 1,000 times the displayed value. Output (lower limit) Peak/bottom Hold Enabled (dhld) Comparison value 2 ON Count Monitor Values for Outputs 1 and 2 (OUT1 and OUT2) (on1c and on2c) Hysteresis The monitor value for output 1 or 2 is only displayed. It cannot be set. The output ON count will be 1,000 times the displayed value. Display value Hysteresis Comparison value 1 OUTX1 OUTY2 Set the hysteresis for when the output turns OFF. Output OFF Delay (offd) This function delays the timing for turning OFF comparative output by a certain time. The ON time can be held for the set time if the comparative result changes in a short time. Operation will continue and outputs will not change while holding the value. Set Value Upper Limit (sl-h) Set the upper limit for the set value when it is set in run mode. 46 H7CX-R@-N Operation in Run Mode • Set each digit using the individual U Keys. H7CX-R11@-N Output Mode: HI-LO or AREA Output Mode: HI or LO Measurement value Measurement value Measurement value Measurement value Comparison value Comparison value 1 *1 Measurement value • Measurement Value Displays the currently measured value. • Comparison Value, Comparison Value 1, and Comparison Value 2 Set the comparison value, comparison value 1, and comparison value 2. The measurement value is compared to comparison value, comparison value 1, and comparison value 2 and an output is made according to the selected output mode. Comparison value 2 *1 H7CX-R11W@-N Measurement value 1 Comparison value 1 Measurement value 2 Comparison value 2 *1 Peak/bottom hold enabled Displayed for Models Other Than “-W” Models Peak hold value Bottom hold value Displayed for “-W” Models Peak hold value 1 Bottom hold value 1 Peak hold value 2 • Peak/bottom hold value The peak (maximum) and bottom (minimum) values are displayed after counting starts. • Peak/bottom hold value 2 Peaks (maximums) 1 and 2 and bottoms (minimums) 1 and 2 are displayed after counting starts. Note: The held values will be initialized when the Hold Key or reset 1 input is turned OFF while peak/bottom hold values 1 and 2 are being displayed.(The reset 2 input operates in the same way if the input mode is set to 2-input mode.) Bottom hold value 2 47 H7CX-R@-N Key Protect Level When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-7). The key protect level is set in the function setting mode. The key protect indicator is lit when the key-protect switch is ON. * OFF (Disable) ON (Enable) *Factory-set to OFF Key protect indicator Details Level Meaning Changing mode* Switching display during operation Hold Key Up Key KP-1 (default setting) Invalid Valid Valid Valid KP-2 Invalid Valid Invalid Valid KP-3 Invalid Valid Valid Invalid KP-4 Invalid Valid Invalid Invalid KP-5 Invalid Invalid Invalid Invalid KP-6 Invalid Invalid Valid Valid KP-7 Invalid Invalid Invalid Valid * Changing mode to DIP switch monitor mode or function setting mode. Self-diagnostic Function The following displays will appear if an error occurs. *1. *2. *3. *4. 48 Main display Sub-display ffffff *3 No change Error Measurement value overflow*2 Output status No change Correction method Set value after reset Measurement value ≤ 999999 No change No change No change e1 Not lit CPU OFF Either press the hold key or reset the power supply. e2 Not lit Memory error (RAM) OFF Turn ON the power again. e2 sum Memory error (EEP)*1 OFF Hold Key Factory setting e3 *4 No change No change Hold Key No change Output Counter Overflow This includes times when the life of the EEPROM has expired. Occurs when the measurement value reaches 999,999. Display flashes (1-second cycles). The normal display and e3 will appear alternately. When the Hold Key is pressed, e3 will not be displayed even if the alarm set value is exceeded. (Monitoring is possible, however, because the counter will continue without clearing the output ON count.) H7CX-R@-N Output Mode Settings Models Other Than H7CX-R11W@ in Tachometer Mode Output mode setting Models Other Than H7CX-R11W@ in AMD-compatible Mode Output mode setting Operation Operation Measurement value Measurement value Upper and lower limit a Comparison value 2 (Upper-limit) Comparison value 2 (Upper-limit) Upper and lower limit Comparison value 1 (Lower-limit) Comparison value 1 (Lower-limit) OUT ON condition: Measurement value < Comparison value 1 or Measurement value ≥ Comparison value 2 Note: When comparison value 1 ≥ comparison value 2, the output isalways ON regardless of the comparison value. OUT ON condition: Measurement value ≤ Comparison value 1 or Measurement value ≥ Comparison value 2 Note: When comparison value 1 ≥ Comparison value 2, the output isalways ON regardless of the comparison value. Comparison value 2 Comparison value 2 b Measurement value Comparison value 1 Measurement value Comparison value 1 Area Area OUT OUT Condition Comparison value 1 ≤ Comparison value 2 Comparison value 1 > Comparison value 2 ON condition Comparison value 1 ≤ measurement value ≤ Comparison value 2 Comparison value 2 ≤ measurement value ≤ Comparison value 1 Comparison value 1 ≤ Comparison value 2 Comparison value 1 > Comparison value 2 ON condition Comparison value 1 ≤ measurement value < Comparison value 2 Comparison value 2 ≤ measurement value < Comparison value 1 Comparison value (Upper-limit) Comparison value (Upper-limit) Measurement value Condition a Measurement value Upper limit Upper limit OUT OUT ON condition: Measurement value ≥ Comparison value ON condition: Measurement value ≥ Comparison value Measurement value Measurement value Lower limit Lower limit Comparison value (Lower-limit) Comparison value (Lower-limit) b OUT OUT ON condition: Measurement value < Comparison value ON condition: Measurement value ≤ Comparison value Note: If time “a” is exceeded during operation, the output will turn ON. If time “b” is exceeded during operation, the output will turn OFF. (If average processing is enabled, the output operation will be performed when the time is exceeded once.) H7CX-R11W@ Output mode setting Operation Output 1 Output 2 Comparison value 1 Upper limit (HI) CP1 display value OUT1 Comparison value 2 CP2 display value OUT2 ON condition for output 1: CP1 present value (display value) ≥ Comparison value 1 ON condition for output 2: CP2 present value (display value) ≥ Comparison value 2 Output 1 Lower limit (LO) Output 2 CP1 display value CP2 display value Comparison value 1 Comparison value 2 OUT1 OUT2 ON condition for output 1: CP1 present value (display value) ≤ Comparison value 1 ON condition for output 2: CP2 present value (display value) ≤ Comparison value 2 49 H7CX-R@-N Precautions for the H7CX-R In upper and lower limit output mode, if the comparison value setting is such that comparison value 1 ≥ comparison value 2, the output will always be ON. Hold Function The measurement value (display value) and output are sustained while the hold input is ON. Note: The output will maintain the current status when the hold key is pressed. Example: Output mode setting Operation Hold input* (Hold Key) Actual input Display value Lower limit Comparison value (lower limit) Sustained display value Sustained output OUT * The H7CX-R11W@-N does not have a hold input. Operation in DIP Switch Monitor Mode The H7CX-R is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display. : Measurement stopped Note: To change the mode to DIP switch monitor mode, press the Power ON 1 Key for 1 s min. with the Key held down. The mode will not change if the 1 Key is pressed first. : Measurement possible The status of the DIP switch pins (1 to 8) can be confirmed using the U Key. Run Mode Example ON + 1 1 s min. DIP Switch Monitor Mode * nt ie ven Con OFF 1 2 3 4 5 6 7 8 …Indicates that DIP switch pin 8 is ON. DIP switch monitor …Indicates that DIP switch pin 7 is OFF. …Indicates that DIP switch pin 6 is ON. …Indicates that DIP switch pin 5 is OFF. …Indicates that DIP switch pin 4 is ON. …Indicates that DIP switch pin 3 is OFF. …Indicates that DIP switch pin 2 is ON. …Indicates that DIP switch pin 1 is OFF. Key 1 Key 50 * When the mode is changed to DIP switch monitor, the measurement value is reset, outputs turns OFF, and measuring stops. H7CX-R@-N Precautions on Replacing the AMD-S The H7CX-R11-N is the recommended model for replacing the AMD-S-series Motion Detector. Refer to the following precautions before replacing the AMD-S. Terminal Arrangement and Wiring Connections AMD-S • Connection Sockets: 8PFA H7CX-R11-N • Connection Sockets: P2CF-11 Black (white) Sensor HOLD Brown (red) HOLD Black (white) Blue (black) 6 5 4 8 3 7 6 5 4 P2CF-11 8PFA Sensor 9 7 8 1 3 10 2 11 1 Blue (black) 2 Brown (red) Tc 100/110 VAC (200/220 VAC) Ta Tb Tb Ta Tc 100 to 240 VAC Relay output Relay output Note: 1. Wiring must be changed from an 8-pin socket to an 11-pin socket. 2. Take into consideration the length of the wires and the terminal numbers. 3. Order the P2CF-11Connecting Socket separately. Setting Procedure Operation Key Settings Perform the following settings to achieve the functions of the AMD-S using the H7CX-R11-N. Model H7CX-R11-N AMD-S Item Parameter s DIP Switch Settings Model Item Startup time H7CX-R11-N AMD-S DIP switch pin status * Set value ON Measuring ranges 0.01 to 0.1 s (AMD-S@1), 0.1 to 1 s (AMDS@2), 1 to 10 s (AMD-S@3) OFF ON ON Output mode Average processing Input mode Rotation increase detection (AMD-SU@) Rotation decrease detection (AMD-SL@) None ON 1 ms 10 ms Model Upper limit (99.9 s) H7CX-R11-N Supply voltage −100 to 110 VAC −200 to 220 VAC −100 to 240 VAC Input method Voltage input (high: 4 to 14 V, low: 0 to 1 V) No-voltage input/voltage input (high: 4.5 to 30 V, low: 0 to 2 V) External power supply 12 VDC ±1 V, 12 mA 12 VDC (±10%), 100 mA Relay output 5 A at 200 VAC (resistive load) 3 A at 250 VAC/30 VDC (resistive load) Output mode Rotation increase (AMDSU@) Rotation decrease (AMDSL@) HI-LO, AREA, HI-HI, LO-LO (Set using DIP switch.) Setting method Input pulse interval (s) Input pulse interval (s) * 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF AMD-S Item Lower limit 1 2 3 4 5 6 7 8 ON OFF (0.0 s) Characteristics Input Counting Speed / mode Minimum input signal width 10 ms OFF AMD compatible 1 ms ON AMD compatible OFF Voltage Input (STMR) Note: The characters displayed in reverse video are the default settings. Pin 2 OFF stmr Set value 1 2 3 4 5 6 7 8 Set DIP switch pin 1 to ON for AMD-compatible mode. Pin 1 Fixed (0.1 to 10 s) Setting range PNP 1 2 3 4 5 6 7 8 Note: The characters displayed in reverse video are the default settings. Detection rota- 6 to 6,000 rpm tion rate range (for 1 pulse/rotation) 0.00006 to 20,000 rpm * (for 1 pulse/rotation) Startup time Always from 0.1 to 10 s (Always 10 s if not specified.) Setting range: 0.0 to 99.9 s Life expectancy Output relay electrical operations of 500,000 min. Output relay electrical operations of 100,000 min. Memory backup None EEPROM (overwrites: 100,000 times min.) * Refer to page page 43 for information on DIP switch settings. * When set to AMD mode. 51 H7CX-@-N Safety Precautions for All H7CX Series (Common) CAUTION Do not allow pieces of metal, wire clippings, or fine metallic shavings or fillings from installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction. Minor injury due to explosion may occasionally occur. Do not use the Counter where subject to flammable or explosive gas. Fire may occasionally occur. Tighten the terminal screws to the rated torque. H7CX terminals: 6.55 to 7.97 lb-in (0.74 to 0.90 N·m) P2CF Socket terminals: 4.4 lb-in (0.5 N·m) Minor injury due to electric shock may occasionally occur. Do not touch any of the terminals while power is being supplied. Be sure to mount the terminal cover after wiring. The life expectancy of the output relay varies considerably according to its usage. Use the output relay within its rated load and electrical life expectancy. If the output relay is used beyond its life expectancy, its contacts may become fused or there may be a risk of fire. Also, be sure that the load current does not exceed the rated load current and when using a heater, be sure to use a thermal switch in the load circuit. Minor electric shock, fire, or malfunction may occasionally occur. Do not disassemble, modify, or repair the Counter or touch internal components. Precautions for Safe Use • The panel surface of the H7CX-A/-R is water-resistant (conforming to NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the internal circuits from water penetration through the space between the H7CX and operating panel, waterproof packing is included. Attach the Y92F-30 Adapter with sufficient pressure with the reinforcing screws so that water does not penetrate the panel. 0.5 to 1 mm It is recommended that the space between the screw head and the Adapter be 0.5 to 1 mm. • When mounting the Counter to a panel, tighten the two mounting screws alternately, a little at a time, so as to keep them at an equal tightness. If the panel screws are tightened unequally, water may enter the panel. • Store the Counter at the specified temperature. If the Counter has been stored at a temperature of less than −10°C, allow the Counter to stand at room temperature for at least 3 hours before use. • Mounting the Counter side-by-side may reduce the life expectancies of internal components. • Use the Counter within the specified ranges for the ambient operating temperature and humidity. • Do not use in the following locations: • Locations subject to sudden or extreme changes in temperature. • Locations where high humidity may result in condensation. • Do not use the Counter outside of the rated ranges for vibration, shock, water exposure, and oil exposure. • Do not use this Counter in dusty environments, in locations where corrosive gasses are present, or in locations subject to direct sunlight. • Install the Counter well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. 52 • Internal elements may be destroyed if a voltage outside the rated voltage range is applied. • Be sure that polarity is correct when wiring the terminals. • Separate the Counter from sources of noise, such as devices with input signals from power lines carrying noise, and wiring for I/O signals. • Do not connect more than two crimp terminals to the same terminal. • Up to two wires of the same size and type can be inserted into a single terminals. • Use the specified wires for wiring. Applicable Wires: AWG 18 to AWG 22, solid or twisted, copper • Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. • When the Counter is operated with no-voltage input (NPN input), approximately 14 V is output from the input terminals. Use a sensor that contains a diode. Sensor Diode 0V Input • Use a switch, relay, or other contact so that the rated power supply voltage will be reached within 0.1 seconds. If the power supply voltage is not reached quickly enough, the Counter may malfunction or outputs may be unstable. • Use a switch, relay, or other contact to turn the power supply OFF instantaneously. Outputs may malfunction and memory errors may occur if the power supply voltage is decreased gradually. • When changing the set value during operation, because the H7CX uses a constant read-in system, output will turn ON if the set value is equal to the present value. • When changing the comparison value during operation, because the H7CX uses a constant read-in system, the output status will change if the comparison value is changed to a value on the other side of the present value. • If the set value and present value are both 0, the output will turn ON for the default setting. The output will turn OFF during a reset operation. • When the power is turned ON using the factory settings, the output will turn ON after 999.9 s if no pulses are received as count input. • Do not use organic solvents (such as paint thinners or benzine), strong alkali, or strong acids. They will damage the external finish. • Confirm that indications are working normally, including the backlight LED, and LCD. The indicator LEDs, LCD, and resin parts may deteriorate more quickly depending on the application environment, preventing normal indications. Periodic inspection and replacement are required. • The waterproof packing may deteriorate, shrink, or harden depending on the application environment. Periodic inspection and replacement are required. H7CX-@-N Precautions for Correct Use • H7CX models with a 12 to 24-VDC power supply use a transformer-free power supply method in which the power supply terminals are not isolated from the signal input terminals. If a nonisolating DC power supply is used, unwanted current paths may occasionally burn or destroy internal components depending on the wiring. Always check the wiring sufficiently before use. • An inrush current of approx. 10 A will flow for a short time when the power supply is turned ON. If the capacity of the power supply is not sufficient, the Counter may not start. Be sure to use a power supply with sufficient capacity. • Maintain voltage fluctuations in the power supply within the specified operating voltage range. • When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below. Power ON supply OFF 200 ms 0 to 90 ms Input Impossible Unstable 5 ms Possible 0 to 1 s Unstable Impossible Load current (mA) • Inrush current generated by turning ON or OFF the power supply may deteriorate contacts on the power supply circuit. Turn ON or OFF to a device with the rated current of more than 10 A. • The capacity of the external power supply is 100 mA at 12 V. When using a 24 VAC/12 to 24 VDC power supply, reduce the load with the power supply voltage, as shown in the following diagram (DC power supplies only). 100 • Attach the front panel when using the Counter. The tabs in the middle of each of four sides secure the front panel to the main body. To remove the panel, widen the four tabs and pull the panel toward you. To mount the panel, fit all four tabs correctly into the grooves on the main body. Tabs Grooves Conformance to EN/IEC Standards • When conforming to EMC standards, refer to the information provided in this datasheet for cable selection and other conditions. • This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference. • H7CX-A@-N: Basic insulation is provided between power supply and input terminals, between power supply and output terminals, and between input and output terminals. (However, no insulation is provided between the power supply and input terminals for the H7CX-A@D-N.) • H7CX-R@-N: Basic insulation is provided between power supply and input terminals and between input and output terminals. • When double insulation or reinforced insulation is required, apply double insulation or reinforced insulation as defined in IEC 60664 that is suitable for the maximum operating voltage with clearances or solid insulation. • Connect the input and output terminals to devices that do not have any exposed charged parts. 20 10.8 15 Power supply voltage (VDC) • If the prescale value setting is incorrect, a counting error will occur. Check that the settings are correct before using this function. • Make sure that all settings are appropriate for the application. Unexpected operation resulting in property damage or accidents may occur if the settings are not appropriate. • Do not leave the Counter for long periods at a high temperature with output current in the ON state. Doing so may result in the premature deterioration of internal components (e.g., electrolytic capacitors). • EEPROM is used as backup memory when the power is interrupted. The write life of the EEPROM is 100,000 writes. The EEPROM is written at the following times: • When the power supply is turned OFF • When switching from Configuration Selection Mode or Function Setting Mode to Run Mode • Dispose of the product according to local ordinances as they apply. 53 MEMO 54 Warranty and Application Considerations Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON Corporation Industrial Automation Company Control Devices Division H.Q. Environment Business Department 2-2-1 Nishikusatsu, Kusatsu-shi, Shiga, 525-0035 Japan Tel: (81) 77-565-6501/Fax: (81) 77-565-7146 Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 Authorized Distributor: OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 OMRON Industrial Automation Global: www.ia.omron.com © OMRON Corporation 2009 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan Cat. No. M079-E1-01 0709