XP Power JVA401500S24 Dc-dc converter Datasheet

JVA40 Series
DC-DC Converter
40 Watts
xxx Series
• Renewable Energy and Industrial Applications
• Ultrawide Input Range - 200-1500 VDC
• Fully Encapsulated PCB Mount & DIN Rail Versions
• Optional DIN Rail Versions with Built In EMI Filter 1500 VDC Fuse
• -40 °C to +70 °C Operating Temperature
• Remote On/Off
• 3 Year Warranty
Dimensions:
JVA4015005: 4.4 x 2.95 x 1.58” (111.76 x 75.0 x 40.0 mm)
JVA4015005-D: 5.43 x 5.75 x 2.17” (138.0 x 146.0 x 55.0 mm)
JVA4015005-DF: 5.08 x 4.02 x 1.92” (129.0 x 102.0 x 49.0 mm)
Models & Ratings
Output Power
Input Voltage
40 W
200-1500 V
Output Voltage
Overvoltage
Protection
Output Current Input Current(1)
Typical
Efficiency(4)
Maximum
Capacitive Load
Model Number(3,4)
12.0 V
20.0 V
3330 mA
66 mA
76%
2000 µF
JVA401500S12
15.0 V
20.0 V
2670 mA
64 mA
78%
1200 µF
JVA401500S15
24.0 V
30.0 V
1670 mA
63 mA
80%
470 µF
JVA401500S24
Notes
1. At 200 VDC input
2. For DIN rail mount option, add suffix '-D' e.g. JVA401500S12-D
3. For DIN rail with added EMI filter option, add suffix '-DF' e.g. JVA401500S24-DF
4. At 800 VDC Input
Input
Characteristic
Input Voltage Range
Minimum
Typical
200
Maximum
Units
1500
VDC
Notes & Conditions
Input Current
320/80/42
mA
200 VDC/800 VDC/1500 VDC input
Inrush Current
30/80/150
A
200 VDC/800 VDC/1500 VDC input
Input Filter
Pi type
Undervoltage Lockout
On 180-195 V, Off 170-185 V
Input Protection
External 15 A/1500 VDC fuse required
This is already included in the optional -DF version
Output
Characteristic
Minimum
Output Voltage
5
Initial Set Accuracy
Minimum Load
Typical
Maximum
Units
24
V
±2
%
0
A
Start Up Delay
2
±1.0
3
%
Load Regulation
1
3
%
150
300
mV pk-pk
Short Circuit Protection
Overload Protection
1
0 - 100% load
20 MHz bandwidth
Trip & Restart (hiccup mode), auto recovery
120
320
%
0.02
%/ ˚C
Overvoltage Protection
Temperature Coefficient
No minimum load required
s
Line Regulation
Ripple & Noise
Notes & Conditions
See Models and Ratings table
Trip & Restart (hiccup mode)
See Models and Ratings table
www.xppower.com
JVA40 Series
DC-DC Converter
General
Characteristic
Minimum
Typical
Isolation
Maximum
%
See Models and Ratings table
VAC
4000
Switching Frequency
65
m
5000
300
Weight
For 60 s
kHz
Operating Altitude
Mean Time Between Failure
Notes & Conditions
Units
72
Efficiency
0.903 (410)
Derate from 100% load at 2000 m to 80% load at 5000 m
kHrs
MIL-HDBK-217F, +25 °C GB
lb (g)
For PCB mount version
Environmental
Maximum
Units
Notes & Conditions
Operating Temperature
-40
+70
°C
See derating curve
Storage Temperature
-50
+85
°C
95
°C
5
95
%RH
Characteristic
Minimum
Typical
Case Temperature
Humidity
Non-condensing
Cooling
Natural convection
Shock
±3 shocks in each plane, total 18 shocks of 30 g : 11 ms halfsine. Conforms to EN60068-2-27 & EN60068-2-47
Vibration
10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55032
Level A
Radiated
EN55032
Level A
Notes & Conditions
See application notes. Not required for ‘-DF’
versions
EMC: Immunity
Phenomenon
Standard
Immunity
EN55024
Test Level
Criteria
ESD Immunity
EN61000-4-2
±6 kV Contact, ±8 kV Air
A
Radiated Immunity
EN61000-4-3
10 V/m
A
A
EFT/Burst
EN61000-4-4
3
Surges
EN61000-4-5
3
A
Conducted Immunity
EN61000-4-6
10 Vm
A
Magnetic Fields
EN61000-4-8
30 A/m
A
Notes & Conditions
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
EN
EN62109
Photovoltaic Power System
UL
UL1741/CSA-C22.2 No.107-1
Distributed Energy Resources
www.xppower.com
2
JVA40 Series
DC-DC Converter
Application Notes
Input Voltage 300-1500 VDC
Thermal Derating Curve
100
90
Output Power (%)
80
70
60
50
40
Input voltage 200-300 VDC
0
-40
Input Derating Curve
0
Ambient Temperature (°C)
50
70
100
90
Output Power (%)
80
70
60
50
40
30
20
10
0
200
0
0
Input Voltage (VDC)
1200
1500
EMI Filter for Conducted Emissions
+Input
L1
Fuse
C7
C8
C9
-Input
C10
Model
L2
+
+
+
+
C3
C4
C5
C6
R1
+Vo
+Vin
R2
R4
C2
TVS RL
JVA401500S15
Element Model
C7/C8/C9/C10
C3/C4/C5/C6
-Vin
-Vo
R1/R2/R3/R4
L1
L2
Fuse
3
www.xppower.com
C1 (µF)
JVA401500S12
JVA401500S24
+
JVA40
R3
C1
1
C2 (µF)
120
120
68
TVS
SMBJ20A
SMBJ20A
SMBJ30A
Recommended Value
104K/275 VAC
47 µF/450 VDC
1 MΩ/2 W
330 µH/1 A
7 mH/1 A
15 A/1500 VDC
JVA40 Series
DC-DC Converter
Mechanical Details
Standard PCB Mount
1.57
(40.0)
Front View
0.23
(6.0)
4 ø 0.138 (ø 3.50)
4.92 (125.0)
4.54 (115.5)
Third Angle Projection
5 ø 0.067 (ø 1.70)
5 ø 0.047 (ø 1.20)
2.95
(75.0)
2
3
2.57
(65.5)
1
5
4
Bottom View
0.40
(10.16)
1.6
(40.6)
Pin
1
2
3
4
5
Pin Connections
Function
-Vin
+Vin
No Connection
-Vo
+Vo
4
1
5
3
2
4-M3 (0.118)
4.40 (111.76)
Note:Grid 2.54*2.54mm
Optional DIN rail mount, -D
5.07 (129.0)
9
7
8
6
Right
View
Front View
4.01
(102.0)
1
2
3
4
Pin
1
2
3
4
5
6
7
8
9
Pin Connections
Function
+Vo
-Vo
No Connection
No Connection
No Connection
+Vin
+Vin
-Vin
-Vin
5
LED
1.92 (49.0)
Optional DIN rail mount with filter, -DF
5.78 (146.0)
LED
9
8
7
6
5
2 x M3 Screws
Unscrew two scres to
replace the fuse from
shell
5.43
(138.0)
5.43
(138.0)
Front View
1
2
3
Bottom View
Pin
1
2
3
4
5
6
7
8
9
Pin Connections
Function
-Vin
-Vin
+Vin
+Vin
+Vo
-Vo
No Connection
No Connection
No Connection
4
Notes
1. All dimensions are in inches (mm)
2. Weight: Standard PCB mount: 0.903 lbs (410 g) approx
Optional DIN rail mount, -D: 1.04 lbs (470 g) approx
Optional DIN rail mount with filter, -DF: 1.59 lbs (720 g) approx
www.xppower.com
05 Jan 18