CD Power Entry Modules with Line Filter www.schurter.com /PG06 IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole (5x20 mm or 6.3x32 mm), Line Switch 1- or 2-pole, Voltage Selector (Step) Standard- or Medical-Filter C14 70° C Description - Panel Mount : Screw-on mounting from front side - 5 Functions : Appliance Inlet , Line Switch , Fuseholder with interchangeable fuse drawer for Fuse-links 5x20 mm or 6.3x32 mm , with or without voltage selector (step switch) , Line filter in standard and medical version - Quick connect terminals 4.8 x 0.8 mm Unique Selling Proposition - Multifunctional Power Entry Module Solid metal flange Various fuse drawers Slim design Characteristics - All single elements are already wired - The fuse drawer "Fingergrip" can be removed by hand - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 References Alternative: version without line filter KD Alternative: Standard version Weblinks pdf-datasheet, html-datasheet, General Product Information, RoHS, CHINA-RoHS, REACH, Distributor-Stock-Check, Accessories, Detailed request for product Approvals - VDE Certificate Number: 40004665 (FKSO, FKSP, FKSU, FKSV) - UL File Number: E72928 (FKSO, FKSP, FKSU, FKSV) Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category IP-Protection Protection Class Terminal Panel Thickness s Material: Housing 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 appliance inlet/-outlet Fuseholder Rated Power Acceptance @ Ta 23 °C Power Acceptance @ Ta > 23°C Line Switch Voltage Selector Line Filter MTBF C14 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm 5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per pole 6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details optional, step, 2-4 digits Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'200'000 h acc. to MIL-HB-217 F EMC Products 1 CD Power Entry Modules with Line Filter www.schurter.com /PG06 Dimension CD 30 55 M3/ø 3.6 2 ø 3.2 R6 +0.3 67.5 0 66.2 83.5 75.5 4.8x0.8 75.5 ±0.15 230 ø 6.3x90° R 4.5 0 R 3 -0.2 56 R 3.1 3 28.5 69 27.2 +0.3 0 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 10 68 2.2 - 2 Standard Version 2x4 68 2.2 - 4 Standard Version 2 x 1.5 68 2.2 - 6 Standard Version 2 x 0.8 68 2.2 - 10 Standard Version 2 x 0.3 68 2.2 - 1 Medical Version (M5) 2 x 10 68 - 1 2 Medical Version (M5) 2x4 68 - 1 4 Medical Version (M5) 2 x 1.5 68 - 1 1 6 Medical Version (M5) 2 x 0.8 68 - 10 Medical Version (M5) 2 x 0.3 68 - 1 2 Medical (M80) 2x4 68 0.47 1 4 Medical (M80) 2 x 1.5 68 0.47 1 10 Medical (M80) 2 x 0.3 68 0.47 1 Diagrams Standard version with voltage selector L Medical version with voltage selector 1a L1 1) Cy PE Cx L2 N Cy 1 F1 L 2) PE’ F2 X) 2 1) Line 2) Load x) External connection to be made by the customer EMC Products 7 N 1a L1 1) PE 2a 2 6 5 4 3 Cx 1 F1 6 5 4 3 2) PE’ R L2 F2 X) 2a 2 1) Line 2) Load x) External connection to be made by the customer 7 CD Power Entry Modules with Line Filter www.schurter.com /PG06 Derating Curves 2.0 I = 1.0 In 1.5 I = 0.7 In I = << In 1.0 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C 2.0 1.5 I = 1.0 In I = 0.7 In 1.0 I = << In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C Fuses 6.3 x 32 mm (2-pole, per pole) 3.15 2.5 I = 1.0 In 2.0 I = 0.7 In 1.5 I = << In 1.0 0.5 0.0 0 20 40 60 80 100 Admissible power acceptance in Watt 2.5 Fuses 6.3 x 32 mm (1-pole) Admissible power acceptance in Watt Fuses 5 x 20 mm (2-pole, per pole) Admissible power acceptance in Watt Admissible power acceptance in Watt Fuses 5 x 20 mm (1-pole) Ambient air temperature Ta °C Attenuation Loss 2.5 2.0 I = 1.0 In 1.5 I = 0.7 In I = << In 1.0 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C - - - - 50Ω differential mode _____ 50Ω common mode Standard version 1A 2A 4A 6A 2A 4A 6A 10 A Medical version (M5) 1A 10 A EMC Products 3 CD Power Entry Modules with Line Filter www.schurter.com /PG06 All Variants Type Rated Current [A] Filter-Type Fuseholder Line Switch Voltage Selector V-Lock Order Number CD 1 Standard Version 1-pole 2-pole - CD11.1501.151 █ CD 2 Standard Version 1-pole 2-pole - CD21.1501.151 █ CD 4 Standard Version 1-pole 2-pole - CD31.1501.151 CD 6 Standard Version 1-pole 2-pole - CD41.1501.151 CD 10 Standard Version 1-pole 2-pole - CD61.1501.151 CD 1 Standard Version 1-pole 2-pole 2-4 digits CD11.4501.151 CD 2 Standard Version 1-pole 2-pole 2-4 digits CD21.4501.151 CD 4 Standard Version 1-pole 2-pole 2-4 digits CD31.4501.151 CD 6 Standard Version 1-pole 2-pole 2-4 digits CD41.4501.151 CD 10 Standard Version 1-pole 2-pole 2-4 digits CD61.4501.151 CD 1 Standard Version 2-pole 2-pole - CD14.1101.151 █ CD 2 Standard Version 2-pole 2-pole - CD24.1101.151 █ CD 4 Standard Version 2-pole 2-pole - CD34.1101.151 █ CD 6 Standard Version 2-pole 2-pole - CD44.1101.151 █ CD 10 Standard Version 2-pole 2-pole - CD64.1101.151 █ CD 1 Standard Version 2-pole 2-pole 2-4 digits CD14.4101.151 █ CD 2 Standard Version 2-pole 2-pole 2-4 digits CD24.4101.151 █ CD 4 Standard Version 2-pole 2-pole 2-4 digits CD34.4101.151 █ CD 6 Standard Version 2-pole 2-pole 2-4 digits CD44.4101.151 █ CD 10 Standard Version 2-pole 2-pole 2-4 digits CD64.4101.151 CD 6 Medical Version (M5) 2-pole 2-pole - CDE4.1101.151 CD 1 Medical Version (M5) 2-pole 2-pole 2-4 digits CDG4.4101.151 CD 2 Medical Version (M5) 2-pole 2-pole 2-4 digits CDA4.4101.151 █ CD 4 Medical Version (M5) 2-pole 2-pole 2-4 digits CDC4.4101.151 █ CD 6 Medical Version (M5) 2-pole 2-pole 2-4 digits CDE4.4101.151 █ CD 6 Medical Version (M5) 2-pole 2-pole 2-4 digits CD 10 Medical Version (M5) 2-pole 2-pole 2-4 digits CDL4.4101.151 CD 2 Medical (M80) 2-pole 2-pole 2-4 digits CDB4.4101.151 CD 4 Medical (M80) 2-pole 2-pole 2-4 digits CDD4.4101.151 CD 10 Medical (M80) 2-pole 2-pole 2-4 digits CDM4.4101.151 CD 10 Medical (M80) 2-pole 2-pole 2-4 digits CDE4.4101.151.21 l CDM4.4101.151.21 l █ Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER Packaging unit 10 Pcs Required Accessory Description Fusedrawer 3 Fusedrawer for Fuse Links 5x20 mm resp. 6.3x32 mm Fingergrip, 5 x 20, 2-pole, Voltage Selector 4303.2014.00 Fingergrip, 5 x 20, 2-pole, Voltage Selector, 100, 120, 220, 240 4303.2014.01 Fingergrip, 5 x 20, 2-pole, Voltage Selector, 110, 150, 220 4303.2014.02 Fingergrip, 5 x 20, 2-pole, Voltage Selector, 110, 220 4303.2014.03 ... 4 EMC Products █ CD Power Entry Modules with Line Filter www.schurter.com /PG06 Accessories Wire Harness Wire harness for SCHURTER products Assorted Covers Rear Cover 0859.0077 Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to CD Connector Overview complete 4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022 4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to CD ... Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS 17.11.2016 Power Cord further types to CD The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 5