Schurter CD21.4501.151 Iec appliance inlet c14 with filter, fuseholder 1- or 2-pole (5x20 mm or 6.3x32 mm), line switch 1- or 2-pole, voltage selector (step) Datasheet

CD
Power Entry Modules with Line Filter
www.schurter.com /PG06
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole (5x20 mm or 6.3x32 mm), Line Switch 1- or
2-pole, Voltage Selector (Step)
Standard- or Medical-Filter
C14
70° C
Description
- Panel Mount :
Screw-on mounting from front side
- 5 Functions :
Appliance Inlet , Line Switch , Fuseholder with interchangeable fuse
drawer for Fuse-links 5x20 mm or 6.3x32 mm , with or without voltage
selector (step switch) , Line filter in standard and medical version
- Quick connect terminals 4.8 x 0.8 mm
Unique Selling Proposition
-
Multifunctional Power Entry Module
Solid metal flange
Various fuse drawers
Slim design
Characteristics
- All single elements are already wired
- The fuse drawer "Fingergrip" can be removed by hand
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
References
Alternative: version without line filter KD
Alternative: Standard version
Weblinks
pdf-datasheet, html-datasheet, General Product Information, RoHS,
CHINA-RoHS, REACH, Distributor-Stock-Check, Accessories, Detailed
request for product
Approvals
- VDE Certificate Number: 40004665 (FKSO, FKSP, FKSU, FKSV)
- UL File Number: E72928 (FKSO, FKSP, FKSU, FKSV)
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Voltage Selector
Line Filter
MTBF
C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32 mm
5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per
pole
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole)
per pole
Admissible power acceptance at higher
ambient temperature see derating curves
2-pole, non-illuminated, acc. to IEC
61058-1
Technical Details
optional, step, 2-4 digits
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 1'200'000 h acc. to MIL-HB-217 F
EMC Products
1
CD
Power Entry Modules with Line Filter
www.schurter.com /PG06
Dimension
CD
30
55
M3/ø 3.6
2
ø 3.2
R6
+0.3
67.5 0
66.2
83.5
75.5
4.8x0.8
75.5 ±0.15
230
ø 6.3x90°
R 4.5
0
R 3 -0.2
56
R 3.1
3
28.5
69
27.2
+0.3
0
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
1
Standard Version
2 x 10
68
2.2
-
2
Standard Version
2x4
68
2.2
-
4
Standard Version
2 x 1.5
68
2.2
-
6
Standard Version
2 x 0.8
68
2.2
-
10
Standard Version
2 x 0.3
68
2.2
-
1
Medical Version (M5)
2 x 10
68
-
1
2
Medical Version (M5)
2x4
68
-
1
4
Medical Version (M5)
2 x 1.5
68
-
1
1
6
Medical Version (M5)
2 x 0.8
68
-
10
Medical Version (M5)
2 x 0.3
68
-
1
2
Medical (M80)
2x4
68
0.47
1
4
Medical (M80)
2 x 1.5
68
0.47
1
10
Medical (M80)
2 x 0.3
68
0.47
1
Diagrams
Standard version
with voltage selector
L
Medical version
with voltage selector
1a
L1
1)
Cy
PE
Cx
L2
N
Cy
1
F1
L
2)
PE’
F2
X)
2
1) Line
2) Load
x) External connection to be made by the customer
EMC Products
7
N
1a
L1
1)
PE
2a
2
6
5
4
3
Cx
1
F1
6
5
4
3
2)
PE’
R
L2
F2
X)
2a
2
1) Line
2) Load
x) External connection to be made by the customer
7
CD
Power Entry Modules with Line Filter
www.schurter.com /PG06
Derating Curves
2.0
I = 1.0 In
1.5
I = 0.7 In
I = << In
1.0
0.5
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
2.0
1.5
I = 1.0 In
I = 0.7 In
1.0
I = << In
0.5
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
Fuses
6.3 x 32 mm (2-pole, per pole)
3.15
2.5
I = 1.0 In
2.0
I = 0.7 In
1.5
I = << In
1.0
0.5
0.0
0
20
40
60
80
100
Admissible power
acceptance in Watt
2.5
Fuses
6.3 x 32 mm (1-pole)
Admissible power
acceptance in Watt
Fuses
5 x 20 mm (2-pole, per pole)
Admissible power
acceptance in Watt
Admissible power
acceptance in Watt
Fuses
5 x 20 mm (1-pole)
Ambient air temperature Ta °C
Attenuation Loss
2.5
2.0
I = 1.0 In
1.5
I = 0.7 In
I = << In
1.0
0.5
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
- - - - 50Ω differential mode _____ 50Ω common mode
Standard version
1A
2A
4A
6A
2A
4A
6A
10 A
Medical version (M5)
1A
10 A
EMC Products
3
CD
Power Entry Modules with Line Filter
www.schurter.com /PG06
All Variants
Type
Rated Current
[A]
Filter-Type
Fuseholder
Line Switch
Voltage Selector
V-Lock
Order Number
CD
1
Standard Version
1-pole
2-pole
-
CD11.1501.151
█
CD
2
Standard Version
1-pole
2-pole
-
CD21.1501.151
█
CD
4
Standard Version
1-pole
2-pole
-
CD31.1501.151
CD
6
Standard Version
1-pole
2-pole
-
CD41.1501.151
CD
10
Standard Version
1-pole
2-pole
-
CD61.1501.151
CD
1
Standard Version
1-pole
2-pole
2-4 digits
CD11.4501.151
CD
2
Standard Version
1-pole
2-pole
2-4 digits
CD21.4501.151
CD
4
Standard Version
1-pole
2-pole
2-4 digits
CD31.4501.151
CD
6
Standard Version
1-pole
2-pole
2-4 digits
CD41.4501.151
CD
10
Standard Version
1-pole
2-pole
2-4 digits
CD61.4501.151
CD
1
Standard Version
2-pole
2-pole
-
CD14.1101.151
█
CD
2
Standard Version
2-pole
2-pole
-
CD24.1101.151
█
CD
4
Standard Version
2-pole
2-pole
-
CD34.1101.151
█
CD
6
Standard Version
2-pole
2-pole
-
CD44.1101.151
█
CD
10
Standard Version
2-pole
2-pole
-
CD64.1101.151
█
CD
1
Standard Version
2-pole
2-pole
2-4 digits
CD14.4101.151
█
CD
2
Standard Version
2-pole
2-pole
2-4 digits
CD24.4101.151
█
CD
4
Standard Version
2-pole
2-pole
2-4 digits
CD34.4101.151
█
CD
6
Standard Version
2-pole
2-pole
2-4 digits
CD44.4101.151
█
CD
10
Standard Version
2-pole
2-pole
2-4 digits
CD64.4101.151
CD
6
Medical Version (M5)
2-pole
2-pole
-
CDE4.1101.151
CD
1
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDG4.4101.151
CD
2
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDA4.4101.151
█
CD
4
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDC4.4101.151
█
CD
6
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDE4.4101.151
█
CD
6
Medical Version (M5)
2-pole
2-pole
2-4 digits
CD
10
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDL4.4101.151
CD
2
Medical (M80)
2-pole
2-pole
2-4 digits
CDB4.4101.151
CD
4
Medical (M80)
2-pole
2-pole
2-4 digits
CDD4.4101.151
CD
10
Medical (M80)
2-pole
2-pole
2-4 digits
CDM4.4101.151
CD
10
Medical (M80)
2-pole
2-pole
2-4 digits
CDE4.4101.151.21
l
CDM4.4101.151.21
l
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER
Packaging unit
10 Pcs
Required Accessory
Description
Fusedrawer 3
Fusedrawer for Fuse Links 5x20 mm resp. 6.3x32 mm
Fingergrip, 5 x 20, 2-pole, Voltage Selector
4303.2014.00
Fingergrip, 5 x 20, 2-pole, Voltage Selector, 100, 120, 220, 240
4303.2014.01
Fingergrip, 5 x 20, 2-pole, Voltage Selector, 110, 150, 220
4303.2014.02
Fingergrip, 5 x 20, 2-pole, Voltage Selector, 110, 220
4303.2014.03
...
4
EMC Products
█
CD
Power Entry Modules with Line Filter
www.schurter.com /PG06
Accessories
Wire Harness
Wire harness for SCHURTER products
Assorted Covers
Rear Cover
0859.0077
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Appliance Outlet further types to CD
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4012
Connector further types to CD
...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC13KS, Overview, diverse Connector IEC C13, cord end:
VAC13KS
17.11.2016
Power Cord further types to CD
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
EMC Products
5
Similar pages