AIMTEC AMLD-6030-RZ Led driver Datasheet

Click on Series name for product info on aimtec.com
Series AMLD-RZ
Up to 1000mA | LED Driver
FEATURES:
• Step Down DC/DC LED driver
• Constant current output
• Ultra Wide (7:1) input voltage range
• High efficiency up to 97%
• Operating Temperature range -40ºC to +85ºC
• Open and Short LED Protection
• PWM / Digital Voltage dimming
• Output power up to 56 Watts
Models
Single output
Input Voltage
(V)
Model
Output Voltage
(V)
Maximum Rated
Current (mA)
Max
Capacitive
Load (uF)
Efficiency
(%)
Ripple &
Noise
(mV p-p)
AMLD-6030-RZ
9-60
2-56
300
2.2
97
250
AMLD-6035-RZ
9-60
2-56
350
2.2
97
300
AMLD-6050-RZ
9-60
2-56
500
2.2
97
350
AMLD-6060-RZ
9-60
2-56
600
2.2
97
400
AMLD-6070-RZ
9-60
2-56
700
2.2
97
400
AMLD-60100-RZ
9-60
2-56
1000
2.2
97
450
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Absolute Maximum Rating
Peak Input Voltage time
DC/DC ON (Leave open if not used)
DC/DC OFF (or short pins 2,3,4)
Maximum Remote pin drive current
Quiescent Current in Shutdown mode
On/Off Control (Digital Control)
Output current adjustment
Output Specifications
Parameters
Current accuracy
Output Voltage range
Output current
Short Circuit protection
Temperature coefficient
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Thermal Impedance
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum Soldering Temperature
NOTES:
Nominal
Typical
48
9-60
Capacitor
ON –Open or 2.5V< Vadj <5V
OFF(shutdown) – Vadj <0.8
Vadj = 0 - 5V
Vin = 60V
Max PWM Frequency 1KHz
1 to 100
Conditions
Typical
±5
2-56
Maximum
Units
65
500
VDC
ms
<1
3
mA
mA
%
Maximum
V input = 60V
Vin – Vout > 4V
Regulated at the rated current for each model
±0.03
Conditions
100% load
Typical
40-1000
See derating chart -40 to +85
-40 to +125
Free air convection
+30
Free air convection
VDC
Maximum
105
95
Non-Conductive Black Plastic (UL94V-0 rated)
17.7
1.25 x 0.80 x 0.49 inches
31.75 x 20.32 x 12.45 mm
> 2 000 000hrs (MIL-HDBK-217 F at +25 oC)
1.5 mm from case for 10sec.
260
Units
%
VDC
o
%/ C
Units
KHz
o
C
o
C
o
C
o
C/W
% RH
g
o
C
1. Reversed polarity at the input power will damage the driver. The input ground must not be connected to the negative output.
2. Maximum output open voltage is equal to input voltage.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMLD-RZ
Up to 1000mA | LED Driver
Safety Specifications
Parameters
Standards
CE
EN 55015 : 2006+A1 : 2007+A2 : 2009
EN 61547 : 2009
(Designed to meet EN 60950-1)
Pin Out Specifications
Pin
2
3
4
9
11
14
16
22
23
Single
- V Input
- V Input
Vadj
- V Output
- V Output
+ V Output
+ V Output
+ V Input
+ V Input
- DC Supply
- DC Supply
PWM/ON/OFF or not used
LED Cathode connection
LED Cathode connection
LED Anode connection
LED Anode connection
+ DC Supply
+ DC Supply
Dimensions
31.75
(1.25)
22.86
(0.90)
2
3
20.32
(0.80)
4
9
11
15.24
(0.60)
Bottom View
23 22
16
2.54
(0.1)
12.45
(0.49)
14
5.08
(0.2)
Mechanical Tolerances
3.00
(0.12
Case tolerance ± 0.25mm or ± 0.01 inches
Pin tolerance ± 0.05 or ± 0.002
0.50
(0.02)
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMLD-RZ
Up to 1000mA | LED Driver
Derating
Free Air Convection
Output Power (%)
100
AMLD-6030-RZ
AMLD-6035-RZ
80
60
AMLD-6050-RZ
AMLD-6060-RZ
AMLD-6070-RZ
AMLD-60100-RZ
Safe Operating Area
40
20
0
- 40
- 20
0
20
40
60
71
80
85
100
Ambient Temperature º C
Typical Application Circuits
Vout+
+
Vin- (or GND)
PWM
22
23
2
3
14
16
AIMTEC
AMLD-60xx-RZ
4
LED Strings
Vin+
9
11
Vout-
5V
0V
Vadj (PWM / Dim / On / Off)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at
www.aimtec.com.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC