Keysight M9202A Pxi-express wideband if digitizer Datasheet

Agilent M9202A
PXI-Express
Wideband IF Digitizer
Data Sheet
12-bit, 2 GS/s, 1 GHz
TM
Challenge the Boundaries
Agilent Modular Products
A p p l i c ati o ns
OV ERV IE W
• Aerospace and defense
• Wireless communication
I n tr o du c ti o n
• Radar and Wideband signal capture
The Agilent Technologies M9202A is a very fast PXIe IF digitizer
featuring wide analog bandwidth, making it ideal for Automated
Test Equipment (ATE) in Aerospace & Defense applications such
as Military Mobile Repair Stations, Radar Test or any application
requiring wideband signal capture and at the same time very high
dynamic range. Thanks to its PXI Express backplane connection,
the M9202A supports continuous data streaming to disk.
F eatures
• 2 GS/s sampling rate
• Up to 1 GHz bandwidth
• SFDR = 60 dBc (typical) in basic digitizer mode
• SFDR = 84 dBc (typical) after digital downconversion (with
DDC option)1
Pr o du c t D e s c r i p t i o n
• Dither function2
The M9202A is a one-slot 3U PXIe 12-bit Wideband IF Digitizer
running at 2 GS/s, with up to 1 GHz instantaneous analog
bandwidth and providing a large 512 Mbytes DDR3 memory. The
M9202A features a Xilinx Virtex-6 FPGA that can implement
different functionalities depending on which firmware option you
choose.
• AC-coupled 50 Ω input impedance
The BAS option provides basic digitizer functionality allowing
capture of a signal, storing of data in the memory and/or transferring it through the backplane connectors for example.
• 512 MB DDR3 Memory
• +4 dBm full scale range (dither disabled2)
• Basic digitizer functionality
• Real-time digital Down Conversion algorithm (with DDC option)
• On-board Xilinx Virtex-6 FPGA
• Data streaming through PXI Express backplane
• IVI-C, IVI-COM, LabVIEW and MATLAB drivers
The DDC option, in addition to basic digitizer functionality, implements a Digital Down Conversion (DDC) algorithm in the 300 MHz
to 700 MHz band, improving the analog performance such as the
Spurious Free Dynamic Range (SFDR) or Signal-to-Noise Ratio
(SNR) and reducing data upload time.
C us to mer val ues
• Fast PXIe 12-bit IF Digitizer
• Capture wide bandwidth signals
The M9202A also provides a continuous digitized data streaming
capability through the V05 and V10 options. The V05 option offers
up to 50 MHz analog bandwidth streaming via the back-plane
connector, whereas the V10 option allows an unprecedented gapfree analog bandwidth streaming of up to 100 MHz in PXI format.
• High dynamic range acquisition for better measurement fidelity
• Large on-board memory
• Data decimation for analog performance and data upload time
improvement
• Continuous stream of wideband signals (up to 100 MHz)
When integrated in the Agilent M9392A PXI Vector Signal
Analyzer, and combined with the 89601 software, the M9202A
provides a complete signal analyzer solution enabling analysis of
communications, radar and avionics signals up to 26.5 GHz in a
modular open-system standard.
• Software support including multiple programmatic interfaces
for easy integration into existing test environments
• Reduced development time
1
2
2
Depends on DDC parameters settings (only with DDC firmware option)
Dither only available with DDC option
EASY SET UP ... T ES T ... A N D M A I N T E N A N C E
H a r d w ar e p l a t f o rm
Software applications
In addition, the M9202A includes the Agilent MD1 soft front
panel (SFP) graphical interface. This simple software application
can be used to control, verify the functionality and explore the
capabilities of the Agilent modular high-speed digitizers. The MD1
SFP provides several different measurement and display capabilities, one being a real-time FFT plot of the acquired signal.
Compliance
The M9202A is PXI Express compliant, using either a PXIe or
a PXIe Hybrid slot. Designed to benefit from fast data interfaces,
the products can be integrated with other test and automation
modules in PXIe and Hybrid chassis. The PXI format offers
high performance in a small, rugged package. It is an ideal
deployment platform for many automated test systems. A wide
array of complementary PXI products are currently available,
including multimeters, waveform generators, local oscillators,
digitizers, downconverters and switch multiplexers.
S oftw ar e p l a t f o rm
IO Libraries
Agilent IO Libraries Suite offers FAST and EASY connection to
instruments and the newest version extends that capability to
include modular instruments.
The Agilent IO Libraries Suite helps you by displaying ALL the
modules in your system, whether they are PXI, PXIe, or PCIe.
From here you can view information about the installed software
or launch the modules’ soft front panel directly from Agilent
Connection Expert.
The Agilent MD1 soft front panel software has two main
windows, the acquisition parameters to control the module and
the acquired waveform display.
In addition, the Agilent Connection Expert (ACE) offers an easy
way to find the correct driver for your instrument.
Drivers
The M9202A Wideband IF Digitizer is supplied with a comprehensive portfolio of module drivers, documentation, examples,
and software tools to help you quickly develop test systems
with your software platform of choice. The module comes with
IVI-COM, IVI-C, LabVIEW and MATLAB software drivers that work
in the most popular T&M development environments including,
LabVIEW and LabWindows/CVI from National Instruments,
MATLAB from The MathWorks, Microsoft C/ C++, C#, and
VB.NET.
Agilent MD1 SFP acquired signal FFT display.
Easy software integration
Figure 1. Soft front panel
To help you get started and complete complex tasks quickly,
the module software is provided with context sensitive help,
complete documentation and code examples that allow a quick
module set up and basic acquisition functionalities. These code
examples can be easily modified, so that the card can be quickly
integrated into a measurement system.
Included are application code examples for LabVIEW,
LabWindows/CVI, Visual Studio C, C++, and C#, Visual Basic,
and MATLAB which provide digitizer set up and basic acquisition functionality. These application code examples are easily
modified to quickly integrate the module into your measurement
system.
3
Firmware options
Product configuration
The M9202A provides two main firmware options: BAS (basic
digitizer firmware) and DDC (digital downconversion firmware).
The M9202A is based on a modular architecture allowing
various product configuration options according to customer
requirements. Any configuration must include the product base
(M9202A), a number of channels, the sampling rate, amount of
memory size and one firmware option.
The BAS option features a basic digitizer firmware that allows
digitizing signals up to 1 GHz at 2 GS/s with a resolution of
12-bit. The digitized data can be stored in the on-board memory
and/or transferred through the PXIe backplane.
Calibration intervals
The DDC option, in addition to the basic digitizer functionality,
implements a real-time digital downconversion and decimation on
the digitized data, allowing to fully analyzing signals of up to
250 MHz bandwidth. DDC settings as dithering level, data bandwidth, trigger bandwidth and frequency shift are variable in order
to satisfy customer needs. One can change the center frequency,
set the amount of digital filtering applied to the data and make
dramatic improvements in the ADC’s harmonic distortion performance by changing these parameters settings. In order to get the
best results from the DDC firmware, anti-alias filtering should be
performed on the signal prior to entering the digitizer. A bandpass
filter, with a passband of 375 to 625 MHz with excellent stopband
rejection at the nearest image band centered at 1.5 GHz on the
upper side, and nominal stopband rejection up to the highest subharmonic of an in-band signal (625 / 2 = 312.5 MHz) on the lower
side is recommended. The signal should peak to -2 dBm at the
digitizer input for optimum performance with the DDC algorithm.
The M9202A is factory calibrated and shipped with a calibration
certificate.
Calibration is recommended every year in order to verify product
performance.
In addition, the M9202A also provides the V05 and V10 options,
which feature continuous digitized data streaming capability
through the PXI Express backplane. The V05 option allows to
stream up to 50 MHz analog bandwidth, whereas the V10 option
doubles the data transfer speed in order to reach an unprecedented 100 MHz gap-free analog bandwidth streaming in PXI format.
4
T E CHNIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S
Analog Input (INPUT 1 SMA connector)
Number of channels
1 (one)
Impedance
50 Ω (nominal)
Coupling
AC
VSWR
< 1.5, (nominal) @ 500 MHz
Full scale (FS) ranges
+4 dBm (1 V pk-pk in 50 Ω)
Maximum input level
+30 dBm (continuous without damage)
-3dB Bandwidth (no filters)
30 MHz (nominal) to 1 GHz
Frequency response flatness
± 1 dB, typical for a frequency range of 100 MHz to 800 MHz
No digital processing (Digitizer mode)
Spurious-Free Dynamic Range (SFDR) 1
@ 125 MHz
54 dBc (60 dBc, typical)
@ 410 MHz
54 dBc (60 dBc, typical)
@ 925 MHz
49 dBc (55 dBc, typical)
Total Harmonic Distortion (THD) 1
@ 125 MHz
–59 dBc (–65 dBc, typical)
@ 410 MHz
–57 dBc (–63 dBc, typical)
@ 925 MHz
Signal to Noise Ratio
–49 dBc (–55 dBc, typical)
2
@ 125 MHz
52 dBc (56 dBc, typical)
@ 410 MHz
51 dBc (55 dBc, typical)
@ 925 MHz
48 dBc (52 dBc, typical)
@ 125 MHz
9 bits (typical)
@ 410 MHz
8.8 bits (typical)
@ 925 MHz
8.2 bits (typical)
ENOB 2
With Digital Downconversion (DDC mode) 3
Spurious-Free Dynamic Range (SFDR) 4
1
2
3
4
@ 300 MHz (frequency shift = 187.5 MHz)
78 dBc (84 dBc, typical)
@ 410 MHz (frequency shift = 93.75 MHz)
78 dBc (84 dBc, typical)
@ 650 MHz (frequency shift = –156.25 MHz)
77 dBc (83 dBc, typical)
Measured for a –1 dBFS input signal in internal clock mode.
Measured for a –1 dBFS input signal in internal clock mode, considering the 2nd through 6th harmonics.
Only with DDC option
Average of 20 measurements on 16384 complex points for a -1 dBFS input signal in internal clock mode. Data Bandwidth = 50 MHz and Dither level = 12 as DDC parameters.
5
T E CHNIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S , CONTINUED
Digital Conversion
Digitizer modes
Basic digitizer or DDC digitizer 1
Resolution
12 bits
Acquisition memory
512 MB (256 MSamples real, 128 MSamples complex)
Sample clock sources
Internal or external
Internal clock source
Internal or external reference
Real-time sampling rates
2 GS/s
Sampling jitter (internal reference)
200 fs RMS (nominal)
Clock accuracy
± 2 ppm
External clock source (CLK 1 IN SMA connector)
Impedance
50 Ω (nominal)
Modes
Continuous
Frequency range
1 GHz
Signal power level
+7 dBm (1.4 V pk-pk in 50 Ω) ± 3 dB
Coupling
AC
External Reference clock (REF IN MMCX connector)
Impedance
50 Ω (nominal)
Frequency range
100 MHz ± 1% (nominal)
Signal power level
+2 dBm ± 5 dB (nominal)
Coupling
AC
Maximum power level
+7 dBm
Time stamps
Records trigger time differences with 250 ps (nominal) resolution
Acquisition modes
Single shot
Digital Downconversion (DDC option only)
1
Digitizer modes
Basic digitizer or DDC digitizer
Recommended input signal peak level
–2 dBm
Flip band
Enabled or disabled
IF Frequency
500 MHz
Usable data bandwidth (DBW)
250 MHz and 200 MHz/2n (n = 0, 1, 2, …, 18)
Trigger bandwidth
250 MHz and 200 MHz/2n (n = 0, 1, 2, …, 18)
Frequency shift
[0, ±Y] + [0, ±2Y] + [0, ±4Y] + … + [0, ±125 MHz], where
Y = 2.5xDBW/4 for DBW ≤ 200 MHz
Dither levels
0, 1, 2, …, 31, where 31 = FS/2 (recommended: 14)
Only with DDC option
6
T E CHNIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S , CONTINUED
Trigger
Trigger modes
Edge (positive, negative)
Trigger sources
External (TRG 1, TRG 2, TRG 3), Software and Magnitude (only with DDC option)
Trigger delay
Pre-trigger
Adjustable to 100% of acquisition window
Post-trigger
Adjustable up to 231-1 samples
External trigger (TRG 1, TRG 2, TRG 3 MMCX connectors)
Coupling
DC
Impedance
50 Ω
Level range
± 5 V (nominal)
Maximum overload protection
±5V
Amplitude range
0.5 V pk-pk
Environmental and physical
Temperature range
1
Operating
Non-Operating
0 °C to 50 °C
-40 °C to +70 °C
Relative humidity
Type tested at 95%, +40°C (non-condensing)
Safety
Complies with EN61010-1
EMC
Complies with European EMC Directive 2004/108/EC
• IEC/EN 61326-1 or IEC/EN 61326-2-1
• CISPR Pub 11 Group 1, class A
• AS/NZS CISPR 11
• ICES/NMB-001
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme a la norme NMB-001 du Canada.
Warm-up time
15 minutes, max
Power dissipation
+3.3 V
+12 V
Total power
2.1 A (nominal)
1.8 A (nominal)
28.5 W (nominal)
Dimensions
• 3U/1-slot PXI-Express
• Chassis slot compatibility: PXIe Hybrid, PXIe
• Front panel complies with IEEE1101.10 certification
Weight
0.8 lb/0.4 kg
System requirements
1
2
Operating Systems
Windows XP, Service Pack 3 or later
(32-bit)
Windows Vista, SP1 and SP2 (32-bit and
64-bit), Business, Ultimate, Enterprise,
Home Basic, and Home Premium
Windows 7 (32-bit and 64-bit)
Starter, Home Basic, Home Premium,
Professional, Ultimate, and Enterprise
Processor speed
600 MHz or higher required 800 MHz
recommended
1 GHz 32-bit (x86), 1 GHz 64-bit (x64),
no support for Itanium 64
1 GHz 32-bit (x86), 1 GHz 64-bit (x64), no
support for Itanium 64
Available
Memory
256 MB minimum
(1 GB or greater recommended)
1 GB minimum
1 GB minimum
Available
Disk Space 1
1.5 GB available hard disk space,
includes:
• 1 GB available for
Microsoft .NET Framework 3.5 SP1 2
• 100 MB for Agilent IO Libraries Suite
1.5 GB available hard disk space,
includes:
• 1 GB available for
Microsoft .NET Framework 3.5 SP1 2
• 100 MB for Agilent IO Libraries Suite
1.5 GB available hard disk space,
includes:
• 1 GB available for
Microsoft .NET Framework 3.5 SP1 2
• 100 MB for Agilent IO Libraries Suite
Video
Super VGA (800x600) 256 colors or
more
Support for DirectX 9 graphics with
128 MB graphics memory recommended
(Super VGA graphics is supported)
Support for DirectX 9 graphics with 128
MB graphics memory recommended
(Super VGA graphics is supported)
Browser
Microsoft Internet Explorer 6.0 or
greater
Microsoft Internet Explorer 7 or greater
Microsoft Internet Explorer 7 or greater
Samples of this product have been type tested in accordance with the Agilent Environmental Test Manual and verified to be robust against the environmental stresses of Storage, Transportationand
End-use; those stresses include but are not limited to temperature, humidity, shock, vibration, altitude and power line conditions. Test Methods are aligned with IEC 60068-2 and levels are similar
to MIL-PRF-28800F Class 3.
NET Framework Runtime Components are installed by default with Windows Vista and Windows 7. Therefore, you may not need this amount of available disk space.
7
CONF IGURA T ION
H a r d w ar e
Model 1
●
●
●
Description
Base
M9202A
PXIe IF Digitizer: 12-bit, 1 GHz
Channels
M9202A-C01
Single channel
Frequency range/Sampling rate
M9202A-F02
●
●
Memory
M9202A-M05
Firmware
M9202A-DDC
M9202A-BAS
Streaming
M9202A-V05
M9202A-V10
●
R el ated p ro d uc ts
Frequency range: 2 GS/s
Standard memory: 512 MB
Digital down-conversion firmware
Basic Digitizer firmware
Streaming, 50 MHz bandwidth
Streaming, 100 MHz bandwidth
Model
Description
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
M9361A
PXI Downconverter: 2.75 GHz to 26.5 GHz
M9362A-D01
PXIe Microwave Quad Downconverter:
10 MHz to 26.5 GHz
M9360A
PXI Attenuator/Preselector: 100 kHz to 26.5 GHz
M9392A
PXI Vector Signal Analyzer
M9211A
PXI-H UWB IF Digitizer: 10-bit, 4 GS/s, 3 GHz
M9018A
18-slot PXIe Chassis
M9021A
PCIe Cable Interface
89601
VSA software
Required options: at least one option has to be selected in each of
these groups.
Recommended configuration
1
For the M9202A to work properly, at least one PXI Express chassis and one PXI controller
type must be available.
A c c es s or i e s
So ftw are
Description
Software and product information on CD (included)
Cables (included)
M9202A PXIe IF Digitizer
CLK 1 IN
ADC
REF IN
TRG 1
TRG 2
TRG 3
TRG OUT
DDR 3
Memory
DDC
PCIe bus
INPUT 1
Time
base
FPGA
Figure 2. Simplified block diagram of the M9202A PXIe IF Digitizer.
8
Model
Description
Supported operating
systems
Microsoft Windows XP (32-bit),
Microsoft Windows Vista (32/64-bit),
Microsoft Windows 7 (32/64-bit)
Standard compliant
drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported
application
development
environments (ADE)
VisualStudio (VB.NET, C#, C/C++), LabVIEW,
LabWindows/CVI, MATLAB
Agilent IO Libraries
Includes: VISA Libraries, Agilent Connection
Expert, IO Monitor
O RD ERING
1
WARRANTY AND CALIBRATION
Model 1
Description
Advantage Services: Calibration and Warranty
M9202A
PXIe IF Digitizer: 12-bit, 1 GHz
M9202A-C01
Single channel
Agilent Advantage Services is committed to your success
throughout your equipment’s lifetime.
M9202A-F02
Frequency range: 2 GS/s
Included
3-year warranty (return to Agilent), standard
M9202A-M05
Standard memory: 512 MB
R-51B-001-5Z
5-year return to Agilent warranty assurance plan
M9202A-BAS
Basic Digitizer firmware
M9202A-DDC
Digital down-conversion firmware
M9202A-V05
Streaming, 50 MHz bandwidth
M9202A-V10
Streaming, 100 MHz bandwidth
For the M9202A to work properly, at least one PXI Express chassis and one PXI controller
type must be available.
Defin ition s f o r s p e c i f i c a t i o ns
Specifications describe the warranted performance of calibrated instruments that have been stored for a minimum of 2 hours within
the operating temperature range of 0 to 50 °C, unless otherwise stated, and after a 45 minute warm-up period. Data represented in this
document are specifications unless otherwise noted.
Characteristics describe product performance that is useful in the application of the product, but that is not covered by the product
warranty. Characteristics are often referred to as Typical or Nominal values.
• Typical describes characteristic performance, which 80% of instruments will meet when operated over a 20 to 30 °C temperature
range. Typical performance is not warranted.
• Nominal describes representative performance that is useful in the application of the product when operated over a 20 to 30 °C
temperature range. Nominal performance is not warranted.
Note: All graphs contain measured data from several units at room temperature unless otherwise noted.
9
T h e Mo d u l ar Tang r am
The four-sided geometric symbol that appears in this document is
called a tangram. The goal of this seven-piece puzzle is to create
identifiable shapes—from simple to complex. As with a tangram,
the possibilities may seem infinite as you begin to create a new
test system. With a set of clearly defined elements—hardware,
software—Agilent can help you create the system you need,
from simple to complex.
www.agilent.com
www.agilent.com/find/modular
www.agilent.com/find/m9202a
For more information on Agilent Technologies’ products,
applications or services, please contact your local Agilent office.
The complete list is available at: www.agilent.com/find/contactus
Americas
Challenge the Boundaries
Agilent Modular Products
TM
www.pxisa.org
myAgilent
myAgilent
www.agilent.com/find/myagilent
Canada
Brazil
Mexico
United States
(877) 894 4414
(11) 4197 3600
01800 5064 800
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 375 8100
Europe & Middle East
Three-Year Warranty
www.agilent.com/find/ThreeYearWarranty
Agilent Advantage Services
www.agilent.com/find/AdvantageServices
www.agilent.com/quality
Belgium
Denmark
Finland
France
Germany
Ireland
Israel
Italy
Netherlands
Spain
Sweden
United Kingdom
32 (0) 2 404 93 40
45 45 80 12 15
358 (0) 10 855 2100
0825 010 700*
*0.125 €/minute
49 (0) 7031 464 6333
1890 924 204
972-3-9288-504/544
39 02 92 60 8484
31 (0) 20 547 2111
34 (91) 631 3300
0200-88 22 55
44 (0) 118 927 6201
For other unlisted countries: www.agilent.com/find/contactus
(BP-10-02-13)
PICMG and the PICMG logo, CompactPCI and the CompactPCI logo, AdvancedTCA and the
AdvancedTCA logo are US registered trademarks of the PCI Industrial Computers Manufacturers Group.“PCIe” and “PCI EXPRESS” are registered trademarks and/or service marks of
PCI-SIG.
Product specifications and descriptions in this document subject to
change without notice.
© Agilent Technologies, Inc. 2010-2013
Published in USA, November 30, 2013
5990-6461EN