Teledyne CR-38SX4C-TD Normally open coaxial switch Datasheet

Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
PART NUMBER
DESCRIPTION
CCR-38S
Commercial Normally Open Multi-throw, DC-18GHz
CR-38S
Elite Normally Open Multi-throw, DC-22GHz
The CCR-38S/CR-38S is a broadband, multi-throw, electromechanical coaxial switch designed to switch
a microwave signal from a common input to any of 3, 4, 5, or 6 outputs. The characteristic impedance
is 50 Ohms. The switches are small using the popular connector spacing on a 1.062” dia. circle. Each
position has an individual actuator mechanism allowing random position selection. This also gives the
minimum switching time.
With the normally open actuator, all paths are open when the switch is de-energized.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Commercial Model, CCR-38S
Elite Model, CR-38S
Form Factor
–40°C to 65°C
–55°C to 85°C
Multi-Throw,
break before make
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
Frequency Range
CCR-38S
CR-38S
DC–18 GHz
DC-22 GHz
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Characteristic Impedance
50 Ohms
Standard Actuator Life
Actuator Life w/ Additional Features
5,000,000 cycles
1,000,000 cycles
Connector Type
SMA
Humidity (Moisture Seal)
Available
Weight
6 oz. (170.1g) (max.)
Operate Time
15 ms (max.)
Release Time
15 ms (max.)
Actuation Voltage Available
12
Actuation Current, max. @ ambient
400 205 170 140 mA
15
24
28 V
PERFORMANCE CHARACTERISTICS
Frequency
DC–4 GHz
4–8 GHz
8–12 GHz
12–16 GHz
16-20 GHz
20-22 GHz
Insertion Loss, dB,
max.
0.1
0.2
0.2
0.3
0.3
0.4
Isolation, dB, min.
80
80
80
80
75
70
1.05:1
1.1:1
1.2:1
1.2:1
1.2:1
1.2:1
VSWR , max.
PART NUMBERING SYSTEM
CCR-38
S
1
6
C
-
T **
Series
Options
Connectors
Actuator Type
Actuator Voltage
Number of Positions
CONNECTOR
ACTUATOR VOLTAGE
NUMBER OF POSITIONS
ACTUATOR TYPE
OPTIONS
S: SMA FEMALE
1: 28 VDC NORMALLY OPEN
3: SP3T
0: NO INDICATOR CONTACTS
T: TTL DRIVERS WITH DIODES
2: 15 VDC NORMALLY OPEN
4: SP4T
C: INDICATOR CONTACTS
D: COIL TRANSIENT SUPPRESSION DIODES
3: 12 VDC NORMALLY OPEN
5: SP5T
S: D-SUB CONNECTOR*
4: 24 VDC NORMALLY OPEN
6: SP6T
TD: DECODERS AND TTL DRIVERS WITH
DIODES
**SEE PARTS LIST ON PAGE 12-13
For additional options, please contact factory.
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
M: MOISTURE SEAL
* D-Sub Connector may be 9 or 15 pin depending on
number of throws. (See Connector Pinout page)
CCR-38S/CR-38S Page 1
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
SCHEMATICS AND MECHANICAL OUTLINE
Analog
Indicators
TTL
SP3T
SP4T
SP5T
H = 1.75 STD & Indicator Model
H = 2.00 D-Sub Model
H = 2.25 Indicator with D-Sub Model
H = 2.50 TTL, TTL with Indicators & TTL with D-Sub Model
SP6T
“-S OPTION” 9-PIN D-SUB OR 15-PIN D-MICRO CONNECTOR (EXAMPLE:
CCR-38S/CR-38S Page 2
CCR-38S160-S)
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
CONNECTOR PINOUT FOR NORMALLY OPEN SP3T MULTI-THROW SWITCHES
EXAMPLE
CR-38S130-S
CR-38S13C-S
INDICATOR
CR-38S130-TS
YES
CR-38S13C-TS
CR-38S130-TDS
YES
TTL
YES
YES
CR-38S13C-TDS
YES
DECODERS & TTL
YES
YES
9-PIN
9-PIN
9-PIN
9-PIN
9-PIN
9-PIN
1
PORT 1
PORT 1
PORT 1
PORT 1
LOGIC 1
LOGIC 1
2
PORT 2
PORT 2
PORT 2
PORT 2
LOGIC 2
LOGIC 2
3
PORT 3
PORT 3
PORT 3
PORT 3
PIN NO.
4
E INDICATOR
E INDICATOR
5
F INDICATOR
F INDICATOR
F INDICATOR
6
G INDICATOR
G INDICATOR
G INDICATOR
7
COMMON
COMMON
COMMON
8
VSW
9
D INDICATOR (COM)
E INDICATOR
COMMON
COMMON
VSW
VSW
D INDICATOR (COM)
COMMON
VSW
D INDICATOR (COM)
CONNECTOR PINOUT FOR NORMALLY OPEN SP4T MULTI-THROW SWITCHES
EXAMPLE
CR-38S140-S
CR-38S14C-S
CR-38S140-TS
YES
INDICATOR
TTL
CR-38S14C-TS
CR-38S140-TDS
YES
YES
YES
CR-38S14C-TDS
YES
DECODERS & TTL
YES
YES
9-PIN
15-PIN
9-PIN
15-PIN
9-PIN
15-PIN
1
PORT 1
PORT 1
TTL 1
TTL 1
LOGIC 1
LOGIC 1
2
PORT 2
PORT 2
TTL 2
TTL 2
LOGIC 2
LOGIC 2
3
PORT 3
PORT 3
TTL 3
TTL 3
LOGIC 3
LOGIC 3
4
PORT 4
PORT 4
TTL 4
TTL 4
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
VSW
VSW
VSW
PIN NO.
5
6
7
8
VSW
9
D INDICATOR (COM)
D INDICATOR (COM)
D INDICATOR (COM)
10
E INDICATOR
E INDICATOR
E INDICATOR
11
F INDICATOR
F INDICATOR
F INDICATOR
12
G INDICATOR
G INDICATOR
G INDICATOR
N/A
N/A
13
H INDICATOR
N/A
H INDICATOR
H INDICATOR
14
15
1
6
15-PIN D-MICRO CONNECTOR
9-PIN D-SUB CONNECTOR
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-38S/CR-38S Page 3
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
CONNECTOR PINOUT FOR NORMALLY OPEN SP5T MULTI-THROW SWITCHES
EXAMPLE
CR-38S150-S
CR-38S15C-S
CR-38S150-TS
YES
INDICATOR
TTL
CR-38S15C-TS
CR-38S150-TDS
YES
YES
YES
CR-38S15C-TDS
YES
DECODERS & TTL
YES
YES
9-PIN
15-PIN
9-PIN
15-PIN
9-PIN
15-PIN
1
PORT 1
PORT 1
TTL 1
TTL 1
LOGIC 1
LOGIC 1
2
PORT 2
PORT 2
TTL 2
TTL 2
LOGIC 2
LOGIC 2
3
PORT 3
PORT 3
TTL 3
TTL 3
LOGIC 3
LOGIC 3
4
PORT 4
PORT 4
TTL 4
TTL 4
5
PORT 5
PORT 5
TTL 5
TTL 5
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
VSW
VSW
VSW
PIN NO.
6
7
8
VSW
9
D INDICATOR (COM)
D INDICATOR (COM)
D INDICATOR (COM)
10
E INDICATOR
E INDICATOR
E INDICATOR
11
F INDICATOR
F INDICATOR
F INDICATOR
12
G INDICATOR
G INDICATOR
G INDICATOR
N/A
N/A
N/A
13
H INDICATOR
H INDICATOR
H INDICATOR
14
K INDICATOR
K INDICATOR
K INDICATOR
15
CONNECTOR PINOUT FOR NORMALLY OPEN SP6T MULTI-THROW SWITCHES
EXAMPLE
CR-38S160-S
CR-38S16C-S
CR-38S160-TS
YES
INDICATOR
TTL
CR-38S16C-TS
CR-38S160-TDS
YES
YES
YES
DECODERS & TTL
CR-38S16C-TDS
YES
YES
YES
9-PIN
15-PIN
9-PIN
15-PIN
9-PIN
15-PIN
1
PORT 1
PORT 1
TTL 1
TTL 1
LOGIC 1
LOGIC 1
2
PORT 2
PORT 2
TTL 2
TTL 2
LOGIC 2
LOGIC 2
3
PORT 3
PORT 3
TTL 3
TTL 3
LOGIC 3
LOGIC 3
4
PORT 4
PORT 4
TTL 4
TTL 4
5
PORT 5
PORT 5
TTL 5
TTL 5
6
PORT 6
PORT 6
TTL 6
TTL 6
7
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
VSW
VSW
VSW
PIN NO.
8
VSW
9
D INDICATOR (COM)
D INDICATOR (COM)
D INDICATOR (COM)
10
E INDICATOR
E INDICATOR
E INDICATOR
11
F INDICATOR
F INDICATOR
F INDICATOR
12
G INDICATOR
G INDICATOR
G INDICATOR
N/A
N/A
N/A
13
H INDICATOR
H INDICATOR
H INDICATOR
14
K INDICATOR
K INDICATOR
K INDICATOR
15
L INDICATOR
L INDICATOR
L INDICATOR
CCR-38S/CR-38S Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
TRUTH TABLE Normally Open
CCR-38SX3C-T
Logic
Input
1
2
RF Path
3
J1
J2
Indicator
Switches
J3
E
F
G
1
0
0
On
Off
Off
C
0
0
0
1
0
Off
On
Off
0
C
0
0
0
1
Off
Off
On
0
0
C
TRUTH TABLE Normally Open
CCR-38SX3C-TD
Logic
Input
1
RF Path
2
J1
J2
Indicator
Switches
J3
E
F
G
0
0
On
Off
Off
C
0
0
1
0
Off
On
Off
0
C
0
0
1
Off
Off
On
0
0
C
1
1
Off
Off
Off
0
0
0
TRUTH TABLE Normally Open
CCR-38SX4C-T
Logic Input
RF Path
Indicator
Switches
1
2
3
4
J1
J2
J3
J4
E
F
G
H
1
0
0
0
On
Off
Off
Off
C
0
0
0
0
1
0
0
Off
On
Off
Off
0
C
0
0
0
0
1
0
Off
Off
On
Off
0
0
C
0
0
0
0
1
Off
Off
Off
On
0
0
0
C
TRUTH TABLE Normally Open
CCR-38SX4C-TD
Logic Input
RF Path
Indicator
Switches
1
2
3
J1
J2
J3
J4
E
F
G
H
0
0
0
On
Off
Off
Off
C
0
0
0
1
0
0
Off
On
Off
Off
0
C
0
0
0
1
0
Off
Off
On
Off
0
0
C
0
1
1
0
Off
Off
Off
On
0
0
0
C
1
1
1
Off
Off
Off
Off
0
0
0
0
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-38S/CR-38S Page 5
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
TRUTH TABLE Normally Open
CCR-38SX5C-T
Logic Input
RF Path
Indicator Switches
1
2
3
4
5
J1
J2
J3
J4
J5
E
F
G
H
K
1
0
0
0
0
On
Off
Off
Off
Off
C
0
0
0
0
0
1
0
0
0
Off
On
Off
Off
Off
0
C
0
0
0
0
0
1
0
0
Off
Off
On
Off
Off
0
0
C
0
0
0
0
0
1
0
Off
Off
Off
On
Off
0
0
0
C
0
0
0
0
0
1
Off
Off
Off
Off
On
0
0
0
0
C
TRUTH TABLE Normally Open
CCR-38SX5C-TD
Logic Input
RF Path
Indicator Switches
1
2
3
J1
J2
J3
J4
J5
E
F
G
H
K
0
0
0
On
Off
Off
Off
Off
C
0
0
0
0
1
0
0
Off
On
Off
Off
Off
0
C
0
0
0
0
1
0
Off
Off
On
Off
Off
0
0
C
0
0
1
1
0
Off
Off
Off
On
Off
0
0
0
C
0
0
0
1
Off
Off
Off
Off
On
0
0
0
0
C
1
1
1
Off
Off
Off
Off
Off
0
0
0
0
0
TRUTH TABLE Normally Open
CCR-38SX6C-T
Logic Input
RF Path
1
2
3
4
5
6
1
0
0
0
0
0
1
0
0
0
0
0
1
0
0
0
Off
0
0
0
1
0
0
Off
0
0
0
0
1
0
Off
0
0
0
0
0
1
Off
J3
J4
Indicator Switches
J1
J2
J5
J6
E
F
G
H
K
L
0
On
Off
Off
Off
0
Off
On
Off
Off
Off
Off
Off
Off
C
0
0
0
0
0
0
C
0
0
0
0
Off
On
Off
Off
Off
Off
Off
On
Off
Off
0
0
C
0
0
0
0
0
0
C
0
0
Off
Off
Off
On
Off
0
0
Off
Off
Off
Off
On
0
0
0
0
C
0
0
0
0
C
TRUTH TABLE Normally Open
CCR-38SX6C-TD
Logic Input
RF Path
Indicator Switches
1
2
3
J1
J2
J3
J4
J5
J6
E
F
G
H
K
L
0
0
0
On
Off
Off
Off
Off
Off
C
0
0
0
0
0
1
0
0
Off
On
Off
Off
Off
Off
0
C
0
0
0
0
0
1
0
Off
Off
On
Off
Off
Off
0
0
C
0
0
0
1
1
0
Off
Off
Off
On
Off
Off
0
0
0
C
0
0
0
0
1
Off
Off
Off
Off
On
Off
0
0
0
0
C
0
1
0
1
Off
Off
Off
Off
Off
On
0
0
0
0
0
C
1
1
1
Off
Off
Off
Off
Off
Off
0
0
0
0
0
0
CCR-38S/CR-38S Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
Insertion Loss ( 4-8 GHz )
0
0
-0.1
-0.1
Insertion Loss (dB)
Insertion Loss (dB)
Insertion Loss ( DC-4 GHz )
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1
-1
0
1
2
3
4
4
5
Frequency (GHz)
Insertion Loss ( 8-12 GHz )
7
8
15
16
Insertion Loss ( 12-16 GHz )
0
0
-0.1
-0.1
-0.2
-0.2
Insertion Loss (dB)
Insertion Loss (dB)
6
Frequency (GHz)
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1
-1
8
9
10
11
12
12
13
Frequency (GHz)
14
Frequency (GHz)
Insertion Loss ( 16-20 GHz )
Insertion Loss ( 20-22 GHz )
0
0
-0.1
-0.2
-0.2
-0.3
Insertion Loss (dB)
Insertion Loss(dB)
-0.1
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1
16
17
18
Frequency (GHz)
19
20
-1
20
20.5
21
21.5
22
Frequency (GHz)
18GHZ+ ELITE MODEL ONLY
RF NOTES
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-38S/CR-38S Page 7
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
Isolation ( 4-8 GHz )
0
0
-20
-20
-40
-40
Isolation (dB)
Isolation (dB)
Isolation ( DC-4 GHz )
-60
-80
-100
-120
-60
-80
-100
-120
-140
-140
0
1
2
3
4
4
5
6
Frequency (GHz)
Isolation ( 8-12 GHz )
8
15
16
Isolation ( 12-16 GHz )
0
0
-20
-20
-40
-40
Isolation (dB)
Isolation (dB)
7
Frequency (GHz)
-60
-80
-100
-120
-60
-80
-100
-120
-140
-140
8
9
10
11
12
12
13
14
Frequency (GHz)
Frequency (GHz)
Isolation ( 16-20 GHz )
Isolation ( 20-22 GHz )
0
0
-20
-40
Isolation (dB)
Isolation (dB)
-20
-60
-80
-100
-40
-60
-80
-100
-120
-120
-140
16
17
18
19
Frequency (GHz)
20
-140
20
20.5
21
21.5
22
Frequency (GHz)
18GHZ+ ELITE MODEL ONLY
RF NOTES
CCR-38S/CR-38S Page 8
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
VSWR ( 4-8 GHz )
2
2
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
VSWR ( DC-4 GHz )
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
1
0
1
2
3
4
4
5
Frequency (GHz)
VSWR ( 8-12 GHz )
7
8
15
16
VSWR ( 12-16 GHz )
2
2
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
6
Frequency (GHz)
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
1
8
9
10
11
12
12
13
Frequency (GHz)
14
Frequency (GHz)
VSWR ( 16-20 GHz )
VSWR ( 20-22 GHz )
2
2
1.9
1.9
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
1.8
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
16
17
18
Frequency (GHz)
19
20
1
20
20.5
21
21.5
22
Frequency (GHz)
18GHZ+ ELITE MODEL ONLY
RF NOTES
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-38S/CR-38S Page 9
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
Power (W)
1000
800
600
400 STAN
DAR
DS
300
MA
200
SW
ITC
HES
100
80
60
40
30
20
10
.1
.2
.3 .4 .6 .8 1
2
4
6 8 10
18
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
CCR-38S/CR-38S Page 10
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
GLOSSARY
Actuator
An actuator is the electromechanical mechanism that
transfers the RF contacts from one position to another upon
DC command.
Arc Suppression Diode
A diode is connected in parallel with the coil. This diode
limits the “reverse EMF spike” generated when the coil deenergizes to 0.7 volts. The diode cathode is connected to
the positive side of the coil and the anode is connected to
the negative side.
Date Code
All switches are marked with either a unique serial number
or a date code. Date codes are in accordance with MILSTD-1285 Paragraph 5.2.5 and consist of four digits.
The first two digits define the year and the last two digits
define the week of the year (YYWW). Thus, 1032 identifies
switches that passed through final inspection during the
32nd week of 2010.
Indicator
Indicators tell the system which position the switch is in.
Other names for indicators are telemetry contacts or tellback
circuit. Indicators are usually a set of internally mounted DC
contacts linked to the actuator. They can be wired to digital
input lines, status lights, or interlocks. Unless otherwise
specified, the maximum indicator contact rating is 30 Vdc,
50 mA, or 1.5 Watts into a resistive load.
Isolation
Isolation is the measure of the power level at the output
connector of an unconnected RF channel as referenced to
the power at the input connector. It is specified in dB below
the input power level.
Multi-Throw Switch
A multi-throw switch is a switch with one input and three or
more output ports. The CCR-38 can switch a microwave
signal to any of 2,3,4,5 or 6 output from a single common
input.
Switching Time
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending with the completion of the switch transfer,
including contact bounce. It consists of three parts: (1)
inductive delay in the coil, (2) transfer time of the physical
movement of the contacts, and (3) the bounce time of the
RF contacts.
TTL Switch Driver Option
As a special option, switch drivers can be provided for both
failsafe and latching switches, which are compatible with
industry-standard low-power Schottky TTL circuits.
TD-Option
This option includes a decoder. The 3-bit parallel command
is decoded to internally select the appropriate position. See
the logic tables. The TD-Option increases the Vsw supply
current demand by 50mA max at 28Vdc and +20°C.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches
is frequency dependent. With increasing frequency, VSWR
and insertion loss increase while isolation decreases. All
data sheets specify these three parameters as “worst case”
at the highest operating frequency. If the switch is to be
used over a narrow frequency band, better performance
can be achieved.
Actuator Current vs Temperature
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
operating temperature of the switch and the actuator drive
current. For switches operating at 28 VDC, the approximate
actuator drive current at temperature, T, can be calculated
using the equation:
IT =
[1 + .00385 (T-20)]
Where:
IT = Actuator current at temperature, T
IA = Room temperature actuator current –
see data sheet
T = Temperature of interest in °C
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous
materials and external magnetic fields. Neighboring ferrous
materials should be permitted no closer than 0.5 inches and
adjacent external magnetic fields should be limited to a flux
density of less than 5 Gauss.
SPECIAL FEATURE
Switching High-Power or Highly Sensitive Signals
Ensure the most linear response with the best galvanically
matched contact system in the industry. Extremely low
passive intermodulation is standard on all of our switches.
Carrier
Frequency 1
Carrier
Frequency 2
PIM 3rd Order
Frequency
PIM 5th
Order Frequency
870 MHz
893 MHz
847 MHz
824 MHz
Multiple
Positions
© 2013 TELEDYNE RELAYS
IA
(800) 284-7007 • www.teledynecoax.com
3rd Order
Intermodulation
5th Order
Intermodulation
–96 dBm
–115 dBm
–139 dBc
–158 dBc
CCR-38S/CR-38S Page 11
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
NORMALLY OPEN CCR-38S/CR-38S PART NUMBER LIST
PART NO.
*
PART NO.
PART NO.
PART NO.
1
CCR-38SX3C
43
CR-38SX30
85
CR-38SX4C
127
CCR-38SX50
2
CCR-38SX3C-D
44
CR-38SX30-D
86
CR-38SX4C-D
128
CCR-38SX50-D
3
CCR-38SX3C-DM
45
CR-38SX30-DM
87
CR-38SX4C-DM
129
CCR-38SX50-DM
4
CCR-38SX3C-M
46
CR-38SX30-M
88
CR-38SX4C-M
130
CCR-38SX50-M
5
CCR-38SX3C-MS
47
CR-38SX30-MS
89
CR-38SX4C-MS
131
CCR-38SX50-MS
6
CCR-38SX3C-S
48
CR-38SX30-S
90
CR-38SX4C-S
132
CCR-38SX50-S
7
CCR-38SX3C-T
49
CR-38SX30-T
91
CR-38SX4C-T
133
CCR-38SX50-T
8
CCR-38SX3C-TD
50
CR-38SX30-TD
92
CR-38SX4C-TD
134
CCR-38SX50-TD
9
CCR-38SX3C-TDM
51
CR-38SX30-TDM
93
CR-38SX4C-TDM
135
CCR-38SX50-TDM
10
CCR-38SX3C-TDMS
52
CR-38SX30-TDMS
94
CR-38SX4C-TDMS
136
CCR-38SX50-TDMS
11
CCR-38SX3C-TDS
53
CR-38SX30-TDS
95
CR-38SX4C-TDS
137
CCR-38SX50-TDS
12
CCR-38SX3C-TM
54
CR-38SX30-TM
96
CR-38SX4C-TM
138
CCR-38SX50-TM
13
CCR-38SX3C-TMS
55
CR-38SX30-TMS
97
CR-38SX4C-TMS
139
CCR-38SX50-TMS
14
CCR-38SX3C-TS
56
CR-38SX30-TS
98
CR-38SX4C-TS
140
CCR-38SX50-TS
15
CCR-38SX30
57
CCR-38SX4C
99
CR-38SX40
141
CR-38SX5C
16
CCR-38SX30-D
58
CCR-38SX4C-D
100
CR-38SX40-D
142
CR-38SX5C-D
17
CCR-38SX30-DM
59
CCR-38SX4C-DM
101
CR-38SX40-DM
143
CR-38SX5C-DM
18
CCR-38SX30-M
60
CCR-38SX4C-M
102
CR-38SX40-M
144
CR-38SX5C-M
19
CCR-38SX30-MS
61
CCR-38SX4C-MS
103
CR-38SX40-MS
145
CR-38SX5C-MS
20
CCR-38SX30-S
62
CCR-38SX4C-S
104
CR-38SX40-S
146
CR-38SX5C-S
21
CCR-38SX30-T
63
CCR-38SX4C-T
105
CR-38SX40-T
147
CR-38SX5C-T
22
CCR-38SX30-TD
64
CCR-38SX4C-TD
106
CR-38SX40-TD
148
CR-38SX5C-TD
23
CCR-38SX30-TDM
65
CCR-38SX4C-TDM
107
CR-38SX40-TDM
149
CR-38SX5C-TDM
24
CCR-38SX30-TDMS
66
CCR-38SX4C-TDMS
108
CR-38SX40-TDMS
150
CR-38SX5C-TDMS
25
CCR-38SX30-TDS
67
CCR-38SX4C-TDS
109
CR-38SX40-TDS
151
CR-38SX5C-TDS
26
CCR-38SX30-TM
68
CCR-38SX4C-TM
110
CR-38SX40-TM
152
CR-38SX5C-TM
27
CCR-38SX30-TMS
69
CCR-38SX4C-TMS
111
CR-38SX40-TMS
153
CR-38SX5C-TMS
28
CCR-38SX30-TS
70
CCR-38SX4C-TS
112
CR-38SX40-TS
154
CR-38SX5C-TS
29
CR-38SX3C
71
CCR-38SX40
113
CCR-38SX5C
155
CR-38SX50
30
CR-38SX3C-D
72
CCR-38SX40-D
114
CCR-38SX5C-D
156
CR-38SX50-D
31
CR-38SX3C-DM
73
CCR-38SX40-DM
115
CCR-38SX5C-DM
157
CR-38SX50-DM
32
CR-38SX3C-M
74
CCR-38SX40-M
116
CCR-38SX5C-M
158
CR-38SX50-M
33
CR-38SX3C-MS
75
CCR-38SX40-MS
117
CCR-38SX5C-MS
159
CR-38SX50-MS
34
CR-38SX3C-S
76
CCR-38SX40-S
118
CCR-38SX5C-S
160
CR-38SX50-S
35
CR-38SX3C-T
77
CCR-38SX40-T
119
CCR-38SX5C-T
161
CR-38SX50-T
36
CR-38SX3C-TD
78
CCR-38SX40-TD
120
CCR-38SX5C-TD
162
CR-38SX50-TD
37
CR-38SX3C-TDM
79
CCR-38SX40-TDM
121
CCR-38SX5C-TDM
163
CR-38SX50-TDM
38
CR-38SX3C-TDMS
80
CCR-38SX40-TDMS
122
CCR-38SX5C-TDMS
164
CR-38SX50-TDMS
39
CR-38SX3C-TDS
81
CCR-38SX40-TDS
123
CCR-38SX5C-TDS
165
CR-38SX50-TDS
40
CR-38SX3C-TM
82
CCR-38SX40-TM
124
CCR-38SX5C-TM
166
CR-38SX50-TM
41
CR-38SX3C-TMS
83
CCR-38SX40-TMS
125
CCR-38SX5C-TMS
167
CR-38SX50-TMS
42
CR-38SX3C-TS
84
CCR-38SX40-TS
126
CCR-38SX5C-TS
168
CR-38SX50-TS
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
CCR-38S/CR-38S Page 12
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCR-38S\CR-38S\072013\Q3
Series CCR-38S/CR-38S
COAX SWITCHES
Multi-Throw DC–18 GHz/DC-22 GHz
Normally Open Coaxial Switch
NORMALLY OPEN CCR-38S/CR-38S PART NUMBER LIST
PART NO.
*
PART NO.
169
CCR-38SX6C
211
CR-38SX60
170
CCR-38SX6C-D
212
CR-38SX60-D
171
CCR-38SX6C-DM
213
CR-38SX60-DM
172
CCR-38SX6C-M
214
CR-38SX60-M
173
CCR-38SX6C-MS
215
CR-38SX60-MS
174
CCR-38SX6C-S
216
CR-38SX60-S
175
CCR-38SX6C-T
217
CR-38SX60-T
176
CCR-38SX6C-TD
218
CR-38SX60-TD
177
CCR-38SX6C-TDM
219
CR-38SX60-TDM
178
CCR-38SX6C-TDMS
220
CR-38SX60-TDMS
179
CCR-38SX6C-TDS
221
CR-38SX60-TDS
180
CCR-38SX6C-TM
222
CR-38SX60-TM
181
CCR-38SX6C-TMS
223
CR-38SX60-TMS
182
CCR-38SX6C-TS
224
CR-38SX60-TS
183
CCR-38SX60
184
CCR-38SX60-D
185
CCR-38SX60-DM
186
CCR-38SX60-M
187
CCR-38SX60-MS
188
CCR-38SX60-S
189
CCR-38SX60-T
190
CCR-38SX60-TD
191
CCR-38SX60-TDM
192
CCR-38SX60-TDMS
193
CCR-38SX60-TDS
194
CCR-38SX60-TM
195
CCR-38SX60-TMS
196
CCR-38SX60-TS
197
CR-38SX6C
198
CR-38SX6C-D
199
CR-38SX6C-DM
200
CR-38SX6C-M
201
CR-38SX6C-MS
202
CR-38SX6C-S
203
CR-38SX6C-T
204
CR-38SX6C-TD
205
CR-38SX6C-TDM
206
CR-38SX6C-TDMS
207
CR-38SX6C-TDS
208
CR-38SX6C-TM
209
CR-38SX6C-TMS
210
CR-38SX6C-TS
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-38S/CR-38S Page 13
CCR-38S\CR-38S\072013\Q3
Similar pages