TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Highlights & Features – – – – – – – – – – – Full corrosion resistant Aluminium chassis Long minimum buffering time of 250ms @ 24V/20A Can connect in parallel to increase buffering time Charging time of < 30 seconds Conformal coating on PCBA to protect against chemical and dust pollutants Hazardous Locations approval to ATEX and Class I, Div 2 (DRB-24V020ABA) IP20 Compliant Overvoltage / Overcurrent / Short Circuit Protections Meets worldwide safety requirements RoHS Directive 2011/65/EU Compliant Reliable design, with expected life of 10 years Safety Standards CB Certified for worldwide use Model Number: DRB-24V020AB□ Unit Weight: 0.76 kg Dimensions (L x W x D): 121 x 70 x 120.1 mm General Description Delta CliQ II Buffer Module offers the most widely used output voltage of 24V and one of the longest buffering time of 0.25 sec (min) at 20A in wide input range from 22.8Vdc to 28.8Vdc. The Buffer Module utilizes maintenance-free electrolytic capacitors to store energy, thus eliminates the need of periodic replacement as compared to costlier batteries which also have shorter functional life span. Delta CliQ II Buffer Module comes with comprehensive protection features like overcurrent/overload, overvoltage and short circuit protection. Delta CliQ II series of products is IP20 compliant with full corrosion resistant Aluminium chassis and conformal coating on the PCBAs to provide protection against dust and chemical pollutants. Model Information CliQ II Buffer Module Model Number Input Voltage Range Output Voltage Output Current DRB-24V020AB□ 22.8-28.8Vdc 24Vdc 20A Model Numbering 1 DR B– 24V 020A B DIN Rail Buffer Module Output Voltage Output Current CliQ II Series All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) □ A - Metal Case, with Class I, Div 2 N - Metal Case, without Class I, Div 2 TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Specifications Input Ratings / Characteristics Nominal Input Voltage 24Vdc Input Voltage Range 22.8-28.8Vdc Maximum Input Voltage 35Vdc Input Current Charging Moded < 0.6A Discharging Moded 20A Max Input Power (Standby Mode) 2.5W Average Maximum Signal Input (Inhibit) 35V / 10mA Max Inrush Current < 20A Charging Time < 30sec Output Ratings / Characteristics Nominal Output Voltage 24Vdc typ. (depends on Vin) Output Voltage Adjustment Range 22-28Vdc Switch = “Fix 22V” Buffering starts if terminal voltage falls below 22V Maximum Output Voltage Factory Setting, Switch = “Vin-1V” Buffering starts if terminal voltage is decreased by > 1V 35Vdc Output Current 20A Max Buffering Time 250ms Min @ 24V/20A Load,5sec Min @ 24V/1A Load (Refer to Fig. 1) 35V / 10mA Maximum Signal Output Signals Inhibit Signal (I) “Low” = Shuts down Buffer Module Ready Signal (R) “High” = Buffer Module is fully charged or in Standby Mode Buffering Signal (B) “High” = Buffer Module is discharging or in Buffering Mode Supply Voltage (+VS) Common +VS, 35V Max PARD (20MHz) < 200mVpp @ 25°C during Buffering Mode Parallel Connection Yes Series Connection No Protective Device Transient Voltage Suppressor (TVS) for signals Fig.1 Buffering Time (Typical Values at “ Vin – 1V” Mode) Mechanical 2 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Case Cover Aluminium Dimensions (L x W x D) 121 x 70 x 120.1 mm Unit Weight 0.76kg LED Indicators Green LED Off Unit is discharged or Vin < 22Vdc Green LED On Unit is fully charged Green LED Blinking Slowly (1Hz) Green LED Blinking Quickly (10Hz) Cooling System Unit is charging Unit is discharging Convection Terminal Input / Output Wire Input / Output AWG 12-10 Signal AWG 24-10 Signal Mounting Rail M3 x 2 Pins (Rated 300V/30A) M3 x 5 Pins (Rated 300V/30A) Standard TS35 DIN Rail in accordance with EN60715 Environment Surrounding Air Temperature Operating -25°C to +75°C Storage -25°C to +85°C Component De-rating Vin = 22.8-28.8Vdc, Max load - Tambient = 50°C - Tj < 85% of Tjmax Operating Humidity < 95% RH (Non-Condensing) Operating Altitude 2,500 Meters Shock Test (Non-Operating) IEC60068-2-27, 30G (300m/S²) for a duration of 18ms Vibration (Non-Operating) IEC60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction Pollution Degree 2 Protections Overvoltage 32V +10% Overload / Overcurrent Short Circuit Penetration Protection 30A Max No Damage > 3.5mm (eg. screws, small parts) Reverse Polarity Protection Yes Degree of Protection IP20 Protection Against Shock Class I without PE* connection *PE: Primary Earth 3 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Reliability Data MTBF(at Vin-1V Mode) > 800,000 hrs. as per Telcordia SR-332 at Standby Mode (Buffer Module in Ready State) 10 years (Standby Mode @ 40°C) Expected Cap Life Time Safety Standards / Directives Electronic Equipment in Power Installations EN50718 / IEC62103 Electrical Safety (Information Technology Equipment) SIQ to EN60950-1, UL/cUL recognized to UL60950-1, CSA C22.2 No. 60950-1, CB scheme to IEC60950-1 Industrial Control Equipment UL/cUL listed to UL508 and CSA C22.2 No. 107.1-01, CSA to CSA C22.2 No. 107.1-01 (File No. 181564) Hazardous Location / ATEX CSA to CSA C22.2 No. 213-M1987, ANSI / ISA 12.12.01:2007 (Class I, Division 2, Group A, B, C, D, T4) EN60079-0:2009, EN60079-15:2010 ( II 3G Ex nA nC IIc T4 Gc) Certificate No. ESP 12 ATEX 1 491 X For IEC60079-0, IEC60079-15 II 3G ATEX 94/9/EC; IECEX Test Report CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input & Output to Ground 1.5KVac Signal to Ground 1.5KVac EMC EMC / Emissions CISPR22, EN55022, EN55011, FCC Title 47: Class B Component Power Supply for General Use EN61204-3 Immunity to EN55024, EN61000-6-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge: 8kV 1) Level 3 Criteria A 80MHz–1GHz, 10V/M with 1kHz tone / 80% modulation Electrostatic Discharge EN61000-4-2 Radiated Field EN61000-4-3 Electrical Fast Transient / Burst EN61000-4-4 Level 3 Criteria A1) 2kV Surge IEC6100-4-5 Level 3 Criteria A1) 2) Common Mode : 2kV 3) Differential Mode : 1kV Conducted EN61000-4-6 Level 3 Criteria A 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields EN61000-4-8 Level 3 Criteria A1) 10A/Meter 1) 1) Voltage Dips EN61000-4-11 Level 3 Criteria A Additional 100% dip; 1 cycle (20ms); No Damage Low Energy Pulse Test (Ring Wave) IEC61000-4-12 Level 3 Criteria A1) 2) Common Mode : 2kV 3) Differential Mode : 1kV Note: Product intended to be used as Apparatus with AC-DC Power Supply, EMC compliance to be verified in correspondence to the connected units. 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) 4 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Block Diagram Device Description 1) 2) 3) 5 Input / Output terminal block connector Signal terminal block connector Select switch (operation mode) 4) 5) LED display status Universal mounting rail system All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Dimensions L x W x D: 121 x 70 x 120.1 mm Engineering Data De-rating Note 1. 2. 3. 4. Fig. 2 6 De-rating for Vertical Mounting Orientation > 70°C de-rate power by 5% / °C All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) Components may degrade, or be damaged, when the buffer module is continuously used outside the shaded region, refer to the graph shown in Fig. 2. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. Depending on the surrounding air temperature and output load delivered by the buffer module, the device housing can be very hot! If the device has to be mounted in any other orientation, please do not hesitate to contact [email protected] for more details. TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Assembly & Installation The buffer module can be mounted on 35mm DIN rails in accordance with EN60715. The device should be installed with input / output terminal block at the top. Each device is delivered ready to install. Mounting Dismounting Fig. 3.1 Mounting Fig. 3.2 Dismounting Snap on the DIN rail as shown in Fig. 3.1: 1. Tilt the unit upwards and insert it onto the DIN rail. 2. Push downwards until stopped. 3. Press against the bottom front side for locking. 4. Shake the unit slightly to ensure that it is secured. To uninstall, pull or slide down the latch with screw driver as shown in Fig 3.2. Then slide the unit in the opposite direction, release the latch and pull out the unit from the rail. Safety Instructions – – – – – – – – 7 ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not turned OFF, there is risk of explosion / severe damage. To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral distance of 20mm to other units. Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. Risk of burns! Only plug in and unplug connectors when power is turned off! DO NOT insert any objects into the unit. Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during this time. The power supplies unit must be installed in an IP54 enclosure. The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants. All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Functions Buffering, Ready, and Inhibit Signal Buffering Signal (B) Maximum Signal Voltage Maximum Signal Current Isolation (Signal Port to Power Port) Ready Signal (R) “High” = Buffer Module is discharging or in Buffering 35Vdc 10mA 1.5KVac “High” = Buffer Module is fully charged or in Standby Mode Maximum Signal Voltage 35Vdc Maximum Signal Current 10mA Isolation (Signal Port to Power Port) Inhibit Signal (I) 1.5KVac “Low” = Shuts down Buffer Module Maximum Signal Voltage 35Vdc Maximum Signal Current 10mA Shut-down Threshold 6Vdc Min / 10Vdc Max Isolation (Signal Port to Power Port) 1.5KVac Operating Diagram Wiring Schematics Typical Application Notes can be found on Page 9. 8 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Typical Application Notes Fig. 4.1 General Connection/Wiring Diagram Fig. 4.2 Paralleling of Buffer Units Fig. 4.3 Decoupling of Buffered Branches Fig. 4.4 General Signals Wiring Fig. 4.5 Signals Supplied from an External Voltage Fig. 4.6 Connection Diagram with Redundant Operation 9 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Connectable Power Supplies The buffer module is recommended to be connected with the following power supplies: CliQ Series CliQ II Series - DRP024V060W1AZ - DRP024V060W1AA - DRP024V120W1AA - DRP024V240W1AA - DRP024V480W1AA - DRP024V060W3AA - DRP024V120W3AA - DRP024V240W3AA - DRP024V480W3AA – DRP024V060W1BA – DRP024V120W1BA – DRP024V240W1BA – DRP024V480W1BA More new products can be found at www.DeltaPSU.com Inrush Current Inrush current is the peak, instantaneous, input current measured and occurs when input voltage is first applied. For DC input voltage the maximum peak value of inrush will occur during the first applied DC voltage. Overload & Overcurrent Protections When the output current exceeds 120% of IO (Max load) buffer module will shut down and latch. Normal operation of buffer module can be resumed upon removal of fault and power supply input is recycled (ON/OFF) or input to buffer module is recycled. Short Circuit Protection Overvoltage Protection The buffer module’s overvoltage protection will be activated when DC input to the module exceeds the maximum specifed input voltage. The overvoltage limits are same as power supply limits, 32V ± 10%. Buffer module will shut down and latch during overvoltage mode, and will return to normal operation upon removal of fault and power supply input is recycled (ON/OFF) or input to buffer module is recycled. 10 Buffer module is protected by short circuit during buffering mode, in the event of short circuit the module will shut down and latch. Operation can be resumed upon removal of fault and power supply input is recycled (ON/OFF) or input to buffer module is recycled. All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01) TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020AB□ Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EC limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. Conformal Coating The Protective Coating Technology Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. The conformal coating dipping can be applied to PCBs or circuit board. The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem especially in highly conversing atmosphere. 11 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (October 2013, Rev. 01)