Bourns MF-R05590U Mf-r/90 series - ptc resettable fus Datasheet

T
PL
IA
N
M
Applications
■ Radial leaded devices
Almost anywhere there is a load to be
protected with a voltage supply of up to
90 V, including:
■ Broadband cable power passing taps
■ Set-top boxes
■ Cured, flame retardant epoxy polymer
CO
*R
oH
S
Features
insulating material meets UL 94V-0
requirements
■ RoHS compliant*
■ Agency recognition:
R0
12255
0S
MF-R/90 Series - PTC Resettable Fuses
Electrical Characteristics
Ihold
Model
V max.
Volts
Itrip
I max.
Amps
Amperes
at 23 °C
MF-R055/90
MF-R055/90U
MF-R075/90
90
90
90
10
10
10
Hold
0.55
0.55
0.75
Trip
1.1
1.1
1.5
Initial
Resistance
Values
One Hour
Post-Trip
Resistance
Standard
Trip
Ohms
at 23 °C
Ohms
at 23 °C
Amperes
at 23 °C
Seconds
at 23 °C
Watts
at 23 °C
Max.
2.0
2.0
1.65
1.6
1.6
2.0
60
28
60
Typ.
2.0
2.0
2.5
Min.
0.45
0.45
0.37
Max.
0.9
0.9
0.75
Max. Time
to Trip
Nominal
Tripped
Power
Dissipation
“U” suffix indicates product without insulation coating.
Environmental Characteristics
Operating/Storage Temperature ...................... -40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State ............................................ 125 °C
Passive Aging .................................................. +85 °C, 1000 hours...........................................±5 % typical resistance change
Humidity Aging................................................. +85 °C, 85 % R.H. 1000 hours .........................±5 % typical resistance change
Thermal Shock ................................................ +125 °C to -55 °C, 10 times ..............................±10 % typical resistance change
Solvent Resistance .......................................... MIL-STD-202, Method 215 ...............................No change
Vibration .......................................................... MIL-STD-883C, Method 2007.1,.......................No change
Condition A
Test Procedures And Requirements For Model MF-R/90 Series
Test
Test Conditions
Accept/Reject Criteria
Visual/Mech. .................................................... Verify dimensions and materials .......................Per MF physical description
Resistance ....................................................... In still air @ 23 °C .............................................Rmin ≤ R ≤ Rmax
Time to Trip ...................................................... 5 times Ihold, Vmax, 23 °C ...............................T ≤ max. time to trip (seconds)
Hold Current .................................................... 30 min. at Ihold .................................................No trip
Trip Cycle Life .................................................. Vmax, Imax, 100 cycles ....................................No arcing or burning
Trip Endurance ................................................ Vmax, 48 hours.................................................No arcing or burning
UL File Number ............................................... E 174545S
CSA File Number ............................................. CA 110338
TÜV File Number ............................................. R2057213
Thermal Derating Chart - Ihold / Itrip (Amps)
Model
Ambient Operating Temperature
-40 ºC
-20 ºC
0 ºC
23 ºC
40 ºC
50 ºC
60 ºC
70 ºC
85 ºC
MF-R055/90
0.85 / 1.7
0.75 / 1.5
0.65 / 1.3
0.55 / 1.1
0.45 / 0.9
0.4 / 0.8
0.35 / 0.7
0.3 / 0.6
0.22 / 0.44
MF-R055/90U
0.85 / 1.7
0.75 / 1.5
0.65 / 1.3
0.55 / 1.1
0.45 / 0.9
0.4 / 0.8
0.35 / 0.7
0.3 / 0.6
0.22 / 0.44
MF-R075/90
1.15 / 2.3
1.0 / 2.0
0.9 / 1.8
0.75 / 1.5
0.61 / 1.22
0.55 / 1.1
0.48 / 0.96
0.41 / 0.82
0.30 / 0.6
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Additional Features
■ Bulk packaging, tape and reel and Ammo-Pak available on most models
MF-R/90 Series - PTC Resettable Fuses
Product Dimensions
A
Max.
10.9
(0.43)
10.3
(0.4)
11.9
(0.47)
Model
MF-R055/90
MF-R055/90U
MF-R075/90
Packaging options:
BULK: 500 pcs. per bag.
B
Max.
16.7
(0.65)
16.7
(0.65)
15.5
(0.61)
C (Pitch)
Nom.
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
TAPE & REEL: 1500 pcs. per reel.
D
Min.
6.3
(0.248)
6.3
(0.248)
6.3
(0.248)
E
Max.
3.6
(0.142)
3.0
(0.118)
3.6
(0.142)
Physical Characteristics
Style
Lead Dia.
Material
0.81
1
Sn/Cu
(0.032)
0.81
1
Sn/Cu
(0.032)
0.81
1
Sn/Cu
(0.032)
DIMENSIONS:
AMMO-PACK: 1000 pcs. per pack
MM
(INCHES)
Style 1
Typical Part Marking
A
How to Order
E
MF - R 055/90 U - 0
Represents total content. Layout may vary.
®
PART
IDENTIFICATION
B
DATE CODE
(FIRST DIGIT =
LAST DIGIT OF YEAR;
NEXT THREE DIGITS =
DAY OF YEAR)
R055
1220S
MANUFACTURER'S
TRADEMARK
Multifuse
Product
Designator
LOT NO.
(S = CHINA)
Series
R = Radial Leaded
Component
D
Hold Current, Ihold
055, 075 (0.55 Amps - 0.75 Amps)
Max. Voltage, V
Coating
__ = Coated
U = Uncoated
C
Packaging Options
- 0 = Bulk Packaging
- 2 = Tape and Reel*
- AP = Ammo-Pak*
Also available with straight leads.
*Packaged per EIA486-B
Typical Time to Trip at 23 ˚C
Time to Trip (Seconds)
100
10
1
MF-R075/90
MF-R055/90
MF-R055/90U
0.1
1
10
Fault Current (Amps)
MF-R/90, REV. G 03/13
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series
Tape and Reel Specifications
Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details.
IEC
Mark
EIA
Mark
Carrier tape width
W
W
Hold down tape width
W0
W4
Dimension Description
Hold down tape
Dimensions
Dimensions
Tolerance
18
-0.5/+1.0
(.709)
(-0.02/+.039)
11
min.
(.433)
No protrusion
Top distance between tape edges
W2
W6
Sprocket hole position
W1
W5
Sprocket hole diameter
D0
D0
Abscissa to plane (straight lead)
H
H
Abscissa to plane (kinked lead)
H0
H0
Abscissa to top (straight lead)
H1
H1
Abscissa to top (kinked lead)
H1
H1
Overall width w/lead protrusion (straight lead)
C1
Overall width w/lead protrusion (kinked lead)
C1
Overall width w/o lead protrusion (straight lead)
C2
Overall width w/o lead protrusion (kinked lead)
C2
3
(.118)
9
(.354)
4
(.157)
18.5
(.728)
16
(.63)
38.0
(1.496)
32.2
(1.268)
55.0
(2.165)
43.2
(1.7)
54.0
(2.126)
42.5
(1.673)
1.0
(.039)
11
(.433)
Lead protrusion
I1
L1
Protrusion of cutout
L
L
Protrusion beyond hold-down tape
I2
I2
Not specified
Sprocket hole pitch
P0
P0
12.7
(0.5)
Pitch tolerance
20 consecutive
max.
-0.5/+0.75
(-0.02/+0.03)
±0.2
(±.0078)
±3.0
(±.118)
±0.5
(±.02)
max.
max.
max.
max.
max.
max.
max.
max.
±0.3
(±.012)
±1
(±.039)
Device pitch: MF-R005–MF-R160, MF-R/90,
MF-RX110/72–MF-RX185/72
12.7
(0.5)
±0.3
(±.012)
Device pitch: MF-R185–MF-R400, MF-RX110–MF-RX375
MF-R/600, MF-RX250/72–MF-RX375/72
25.4
(1.0)
±0.6
(±.024)
0.9
(.035)
max.
Tape thickness
t
t
Tape thickness with splice: MF-R010–MF-R160,
MF-RX110/72–MF-RX185/72
t1
1.5
(.059)
max.
Tape thickness with splice: MF-R250–MF-R1100,
MF-RX110–MF-RX375, MF-R/90, MF-RX250/72-MF-RX375/72
t1
2.3
(.091)
max.
Splice sprocket hole alignment
0
Body lateral deviation
Δh
Δh
0
Body tape plane deviation
Δp
Δp
0
±0.3
(±.012)
±1.0
(±.039)
±1.3
(±.051)
DIMENSIONS:
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
MM
(INCHES)
MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series
Tape and Reel Specifications
IEC
Mark
EIA
Mark
Lead spacing: MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72
F
F
Lead spacing: MF-RX/250
F
F
Reel width
w
W2
Reel diameter
d
a
W1
h
Arbor hole diameter
f
c
Core diameter: MF-R, MF-RX, MF-R/90
h
n
Core diameter: MF-RX/250, MF-R/600
h
n
Dimension Description
Space between flanges less device
Box: MF-R, MF-RX, MF-R/90
Box: MF-RX/250
Box: MF-R/600
Dimensions
Dimensions
Tolerance
5.08
±0.2
(0.2)
(±0.008)
5.08
-0.5/+0.6
(0.2)
(-.020/+.024)
56.0
max.
(2.205)
370.0
max.
(14.57)
4.75
±3.25
(.187)
(±.128)
26.0
±12.0
(1.024)
(±.472)
80
max.
(3.15)
91
max.
(3.58)
62
355
345
nom.
(2.44) (14.0) (13.6)
67
372
362
max.
(2.64) (14.6) (14.25)
64
372
362
max.
(2.52) (14.6) (14.25)
Consecutive missing places: MF-R, MF-RX, MF-R/90
3
Consecutive missing places: MF-RX/250, MF-R/600
none
max.
Empty places per reel: MF-R, MF-RX, MF-R/90
Not specified
Empty places per reel: MF-RX/250, MF-R/600
0.1 %
Taped Component Dimensions Figure 1
Δh
Δp
Δh
Δp
Reference plane
P1
H1
A
L
I2
H1
F
H
H0
B
W0
P0
I1
D0
W1
W
User direction of feed
Cross section A - B
t
Reel Dimensions - Figure 2
Reel
h
d
User
direction
of
feed
Upper side
Tape
Lower side
f
h
w
DIMENSIONS:
MM
(INCHES)
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Similar pages