Aluminum electrolytic capacitors Single-ended capacitors Series/Type: B41858 Date: October 2015 © EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Single-ended capacitors B41858 Low impedance 105 °C Long-life grade capacitors Applications Automotive electronics For use in output circuits of switch-mode power supplies of compact design For professional industrial electronics, telecommunications and data processing equipment Features Low impedance at high frequency High reliability Low ESR High ripple current capability RoHS-compatible Construction Radial leads Charge-discharge proof, polar Aluminum case with insulating sleeve Minus pole marking on the insulating sleeve Case with safety vent Delivery mode Terminal configurations and packing: Bulk Taped, Ammo pack Cut Kinked PAPR (protection against polarity reversal): crimped leads, J leads, bent leads Refer to chapter "Single-ended capacitors Taping, packing and lead configurations" for further details. Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 33 B41858 Low impedance 105 °C Specifications and characteristics in brief Rated voltage VR Surge voltage VS 10 ... 100 V DC 1.15 VR Rated capacitance CR Capacitance tolerance 22 ... 10000 µF ±20% M Dissipation factor tan δ (20 °C, 120 Hz) For capacitance higher than 1000 µF add 0.02 for every increase of 1000 µF. VR (V DC) 10 16 25 35 50 63 100 tan δ (max.) 0.19 Diameter (mm) 8 ... 12.5 16 18 ESL (nH) 20 26 34 0.16 0.14 0.12 0.10 0.10 0.08 Leakage current Ileak (20 °C, 5 min) Self-inductance ESL Useful life1) 105 °C; VR; IAC,R Requirements Voltage endurance test 105 °C; VR Post test requirements Vibration resistance test > 3000 h for d = 8 mm > 5000 h for d ≥ 10 mm ∆C/C ≤ 40% of initial value tan δ ≤ 3 times initial specified limit Ileak ≤ initial specified limit 3000 h for d = 8 mm 5000 h for d ≥ 10 mm ∆C/C ≤ 30% of initial value tan δ ≤ 2 times initial specified limit Ileak ≤ initial specified limit To IEC 60068-2-6, test Fc: Frequency range 10 Hz ... 2 kHz, displacement amplitude max. 1.5 mm, acceleration max. 20 g, duration 3 × 2 h. Capacitor rigidly clamped by the aluminum case. IEC climatic category To IEC 60068-1: 55/105/56 (55 °C/+105 °C/56 days damp heat test) Sectional specification IEC 60384-4, AEC Q200 1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life. Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 33 B41858 Low impedance 105 °C Dimensional drawings With stand-off rubber seal Diameters (mm): 10, 12.5, 16, 18 With flat rubber seal Diameter (mm): 8 Dimensions and weights Dimensions (mm) d +0.5 8 10 10 10 12.5 12.5 12.5 12.5 16 16 16 16 18 18 18 18 18 l 11.5 +1.5 12.5 +1.0 16 +1.0 20 +2.0 20 +2.0 25 +2.0 30 +2.0 40 +2.0 20 +2.0 25 +2.0 31.5 +2.0 35.5 +2.0 20 +2.0 25 +2.0 31.5 +2.0 35 +2.0 40 +2.0 Please read Cautions and warnings and Important notes at the end of this document. a ±0.5 3.5 5.0 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 Page 4 of 33 b 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.1 0.80 ±0.1 0.80 ±0.1 0.80 ±0.1 0.80 ±0.1 Approx. weight g 1.0 1.6 1.9 2.6 3.6 4.5 5.3 7.4 5.5 7.5 7.8 9.2 8.0 9.0 11.0 13.0 16.0 B41858 Low impedance 105 °C Overview of available types VR (V DC) 10 16 25 35 Case dimensions d × l (mm) CR (µF) 100 8 × 11.5 120 8 × 11.5 8 × 11.5 180 8 × 11.5 10 × 12.5 220 8 × 11.5 10 × 12.5 150 270 8 × 11.5 10 × 12.5 8 × 11.5 10 × 12.5 10 × 16 330 8 × 11.5 390 8 × 11.5 470 8 × 11.5 10 × 12.5 10 × 16 10 × 20 560 10 × 12.5 10 × 16 10 × 16 10 × 20 680 10 × 12.5 10 × 16 10 × 20 12.5 × 20 × 20 820 10 × 16 10 × 20 10 1000 10 × 16 10 × 20 12.5 × 20 1200 10 × 16 10 × 20 1500 10 × 20 12.5 × 20 12.5 × 25 1800 10 × 20 12.5 × 25 16 × 20 16 18 × 25 × 20 2200 12.5 × 20 12.5 × 25 12.5 × 40 16 × 25 18 × 20 18 × 25 2700 12.5 × 25 16 × 20 16 18 × 31.5 × 20 18 × 31.5 3300 12.5 × 25 16 × 20 12.5 × 40 16 × 25 18 × 25 16 18 × 35.5 × 31.5 3900 12.5 × 40 16 × 20 16 18 × 31.5 × 20 16 18 × 35.5 × 31.5 18 × 35 4700 18 × 20 18 × 25 18 × 31.5 18 × 40 5600 12.5 × 40 18 × 35 6800 16 × 31.5 18 × 31.5 18 × 40 8200 18 × 31.5 18 × 35 10000 18 × 35 18 × 40 Please read Cautions and warnings and Important notes at the end of this document. 12.5 × 25 16 × 20 16 Page 5 of 33 × 20 12.5 × 40 16 × 25 B41858 Low impedance 105 °C VR (V DC) 50 63 100 Case dimensions d × l (mm) CR (µF) × 11.5 22 8 33 10 × 16 47 10 × 20 68 8 × 11.5 100 8 × 11.5 10 × 12.5 12.5 × 20 120 10 × 12.5 10 × 16 12.5 × 25 150 10 × 12.5 10 × 16 180 10 × 16 10 × 20 12.5 × 30 16 × 20 220 10 × 16 10 × 20 16 270 330 10 × 20 390 12.5 × 40 18 × 20 12.5 × 20 16 18 × 31.5 × 25 12.5 × 25 18 × 31.5 12.5 × 25 16 × 20 18 × 35 18 × 35 18 × 40 470 12.5 × 20 560 12.5 × 25 680 12.5 × 30 12.5 × 40 16 × 25 18 × 20 820 12.5 × 40 16 × 20 16 18 × 31.5 × 25 1000 16 18 × 31.5 × 20 16 × 31.5 1200 18 × 20 18 × 31.5 1500 18 × 25 18 × 35 1800 16 18 × 35.5 × 31.5 18 × 40 2200 18 × 35 2700 18 × 40 Other voltage and capacitance ratings are available upon request. Please read Cautions and warnings and Important notes at the end of this document. × 25 12.5 × 20 Page 6 of 33 B41858 Low impedance 105 °C Technical data and ordering codes CR 120 Hz 20 °C µF Case dimensions d×l mm ESRmax 10 kHz 40 °C Ω VR = 10 V DC 330 8 × 11.5 390 8 × 11.5 470 8 × 11.5 560 10 × 12.5 680 10 × 12.5 820 10 × 16 1000 10 × 16 1200 10 × 16 1500 10 × 20 1800 10 × 20 2200 12.5 × 20 2700 12.5 × 25 3300 12.5 × 25 3300 16 × 20 3900 12.5 × 40 3900 16 × 20 4700 18 × 20 5600 12.5 × 40 6800 16 × 31.5 8200 18 × 31.5 10000 18 × 35 2.195 2.195 2.195 1.035 1.035 0.946 0.946 0.944 0.584 0.584 0.496 0.327 0.327 0.307 0.240 0.307 0.271 0.243 0.192 0.165 0.160 ESRmax 10 kHz 20 °C Ω Zmax 100 kHz 20 °C Ω IAC,R 100 kHz 105 °C mA Ordering code (composition see below) 0.274 0.274 0.274 0.129 0.129 0.118 0.118 0.118 0.073 0.073 0.062 0.041 0.041 0.038 0.030 0.038 0.034 0.030 0.024 0.021 0.020 0.246 0.246 0.246 0.113 0.113 0.105 0.105 0.105 0.062 0.062 0.060 0.034 0.034 0.033 0.025 0.033 0.031 0.025 0.022 0.020 0.018 436 436 436 746 746 846 846 846 1202 1202 1396 2028 2028 2146 2858 2146 2381 2858 3122 3539 3864 B41858C3337M*** B41858C3397M*** B41858C3477M*** B41858C3567M*** B41858C3687M*** B41858C3827M*** B41858C3108M*** B41858C3128M*** B41858C3158M*** B41858C3188M*** B41858C3228M*** B41858C3278M*** B41858C3338M*** B41858D3338M*** B41858C3398M*** B41858D3398M*** B41858C3478M*** B41858C3568M*** B41858C3688M*** B41858C3828M*** B41858C3109M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (for ∅ 16 ... 18 mm) 004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and 18 × 20 ... 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 7 of 33 B41858 Low impedance 105 °C Technical data and ordering codes CR 120 Hz 20 °C µF Case dimensions d×l mm ESRmax 10 kHz 40 °C Ω VR = 16 V DC 270 8 × 11.5 330 8 × 11.5 470 10 × 12.5 560 10 × 16 680 10 × 16 820 10 × 20 1000 10 × 20 1200 10 × 20 1500 12.5 × 20 1800 12.5 × 25 2200 12.5 × 25 2700 16 × 20 3300 12.5 × 40 3300 16 × 25 3900 16 × 31.5 3900 18 × 20 4700 18 × 25 6800 18 × 31.5 8200 18 × 35 10000 18 × 40 2.192 2.192 1.035 0.944 0.946 0.584 0.584 0.584 0.496 0.327 0.327 0.307 0.243 0.251 0.192 0.271 0.217 0.165 0.160 0.125 ESRmax 10 kHz 20 °C Ω Zmax 100 kHz 20 °C Ω IAC,R 100 kHz 105 °C mA Ordering code (composition see below) 0.274 0.274 0.129 0.118 0.118 0.073 0.073 0.073 0.062 0.041 0.041 0.038 0.030 0.031 0.024 0.034 0.027 0.021 0.020 0.016 0.246 0.246 0.113 0.105 0.105 0.062 0.062 0.062 0.060 0.034 0.034 0.033 0.025 0.029 0.022 0.031 0.024 0.020 0.018 0.015 436 436 746 846 846 1202 1202 1202 1396 2028 2028 2146 2858 2483 3122 2381 2941 3539 3864 4467 B41858D4277M*** B41858D4337M*** B41858C4477M*** B41858C4567M*** B41858C4687M*** B41858C4827M*** B41858C4108M*** B41858C4128M*** B41858C4158M*** B41858C4188M*** B41858C4228M*** B41858C4278M*** B41858D4338M*** B41858C4338M*** B41858D4398M*** B41858C4398M*** B41858C4478M*** B41858C4688M*** B41858C4828M*** B41858C4109M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (for ∅ 16 ... 18 mm) 004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and 18 × 20 ... 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 8 of 33 B41858 Low impedance 105 °C Technical data and ordering codes CR 120 Hz 20 °C µF Case dimensions d×l mm ESRmax 10 kHz 40 °C Ω VR = 25 V DC 180 8 × 11.5 220 8 × 11.5 270 10 × 12.5 330 10 × 12.5 470 10 × 16 560 10 × 16 680 10 × 20 820 10 × 20 1000 12.5 × 20 1500 12.5 × 25 1800 16 × 20 2200 12.5 × 40 2200 16 × 25 2200 18 × 20 2700 16 × 31.5 2700 18 × 20 3300 18 × 25 3900 16 × 35.5 3900 18 × 31.5 4700 18 × 31.5 5600 18 × 35 6800 18 × 40 2.192 2.192 1.032 1.035 0.946 0.944 0.584 0.584 0.496 0.327 0.307 0.243 0.251 0.248 0.192 0.271 0.217 0.168 0.165 0.165 0.160 0.128 ESRmax 10 kHz 20 °C Ω Zmax 100 kHz 20 °C Ω IAC,R 100 kHz 105 °C mA Ordering code (composition see below) 0.274 0.274 0.129 0.129 0.118 0.118 0.073 0.073 0.062 0.041 0.038 0.030 0.031 0.031 0.024 0.034 0.027 0.021 0.021 0.021 0.020 0.016 0.246 0.246 0.113 0.113 0.105 0.105 0.062 0.062 0.060 0.034 0.033 0.025 0.029 0.031 0.022 0.031 0.024 0.019 0.020 0.020 0.018 0.015 436 436 746 746 846 846 1202 1202 1396 2028 2146 2858 2483 2381 3122 2381 2941 3408 3539 3539 3864 4467 B41858D5187M*** B41858D5227M*** B41858C5277M*** B41858C5337M*** B41858C5477M*** B41858C5567M*** B41858C5687M*** B41858C5827M*** B41858C5108M*** B41858C5158M*** B41858C5188M*** B41858D5228M*** B41858C5228M*** B41858E5228M*** B41858D5278M*** B41858C5278M*** B41858C5338M*** B41858D5398M*** B41858C5398M*** B41858D5478M*** B41858D5568M*** B41858C5688M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (for ∅ 16 ... 18 mm) 004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and 18 × 20 ... 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 9 of 33 B41858 Low impedance 105 °C Technical data and ordering codes CR 120 Hz 20 °C µF Case dimensions d×l mm ESRmax 10 kHz 40 °C Ω VR = 35 V DC 100 8 × 11.5 120 8 × 11.5 150 8 × 11.5 180 10 × 12.5 220 10 × 12.5 330 10 × 16 470 10 × 20 560 10 × 20 680 12.5 × 20 1000 12.5 × 25 1000 16 × 20 1200 16 × 20 1500 12.5 × 40 1500 16 × 25 1800 16 × 25 1800 18 × 20 2200 18 × 25 2700 18 × 31.5 3300 16 × 35.5 3300 18 × 31.5 3900 18 × 35 4700 18 × 40 2.192 2.192 2.192 1.035 1.035 0.946 0.584 0.584 0.496 0.327 0.304 0.307 0.243 0.251 0.248 0.271 0.217 0.165 0.168 0.165 0.160 0.125 ESRmax 10 kHz 20 °C Ω Zmax 100 kHz 20 °C Ω IAC,R 100 kHz 105 °C mA Ordering code (composition see below) 0.274 0.274 0.274 0.129 0.129 0.118 0.073 0.073 0.062 0.041 0.038 0.038 0.030 0.031 0.031 0.034 0.027 0.021 0.021 0.021 0.020 0.016 0.246 0.246 0.246 0.113 0.113 0.105 0.062 0.062 0.060 0.034 0.033 0.033 0.025 0.029 0.029 0.031 0.024 0.020 0.019 0.020 0.018 0.015 436 436 436 746 746 846 1202 1202 1396 2028 2146 2146 2858 2483 2483 2381 2941 3539 3408 3539 3864 4467 B41858C7107M*** B41858D7127M*** B41858C7157M*** B41858C7187M*** B41858C7227M*** B41858C7337M*** B41858C7477M*** B41858C7567M*** B41858C7687M*** B41858C7108M*** B41858D7108M*** B41858C7128M*** B41858D7158M*** B41858C7158M*** B41858E7188M*** B41858C7188M*** B41858C7228M*** B41858C7278M*** B41858E7338M*** B41858D7338M*** B41858C7398M*** B41858C7478M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (for ∅ 16 ... 18 mm) 004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and 18 × 20 ... 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 10 of 33 B41858 Low impedance 105 °C Technical data and ordering codes CR 120 Hz 20 °C µF Case dimensions d×l mm ESRmax 10 kHz 40 °C Ω VR = 50 V DC 100 8 × 11.5 120 10 × 12.5 150 10 × 12.5 180 10 × 16 220 10 × 16 330 10 × 20 470 12.5 × 20 560 12.5 × 25 680 12.5 × 30 820 12.5 × 40 820 16 × 20 1000 16 × 31.5 1000 18 × 20 1200 18 × 20 1500 18 × 25 1800 16 × 35.5 1800 18 × 31.5 2200 18 × 35 2700 18 × 40 5.168 2.984 2.984 1.400 1.400 1.000 0.880 0.712 0.360 0.269 0.401 0.260 0.477 0.384 0.382 0.232 0.300 0.268 0.210 ESRmax 10 kHz 20 °C Ω Zmax 100 kHz 20 °C Ω IAC,R 100 kHz 105 °C mA Ordering code (composition see below) 0.646 0.373 0.373 0.175 0.175 0.125 0.110 0.089 0.045 0.034 0.050 0.032 0.048 0.048 0.038 0.029 0.030 0.027 0.021 0.573 0.336 0.336 0.160 0.160 0.118 0.104 0.082 0.043 0.032 0.046 0.030 0.044 0.044 0.036 0.026 0.028 0.024 0.020 340 555 555 778 778 1030 1300 1490 2140 2799 1820 2653 1997 1997 2417 2896 2989 3320 3871 B41858C6107M*** B41858C6127M*** B41858C6157M*** B41858C6187M*** B41858C6227M*** B41858C6337M*** B41858C6477M*** B41858C6567M*** B41858C6687M*** B41858C6827M*** B41858D6827M*** B41858C6108M*** B41858D6108M*** B41858C6128M*** B41858C6158M*** B41858D6188M*** B41858C6188M*** B41858C6228M*** B41858C6278M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (for ∅ 16 ... 18 mm) 004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and 18 × 20 ... 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 11 of 33 B41858 Low impedance 105 °C Technical data and ordering codes CR 120 Hz 20 °C µF Case dimensions d×l mm ESRmax 10 kHz 40 °C Ω VR = 63 V DC 68 8 × 11.5 100 10 × 12.5 120 10 × 16 150 10 × 16 180 10 × 20 220 10 × 20 270 12.5 × 20 330 12.5 × 20 390 12.5 × 25 470 12.5 × 25 470 16 × 20 680 12.5 × 40 680 16 × 25 680 18 × 20 820 16 × 31.5 820 18 × 25 1000 16 × 31.5 1200 18 × 31.5 1500 18 × 35 1800 18 × 40 4.328 4.616 3.075 2.464 1.986 1.592 1.688 1.688 1.236 0.992 1.037 0.717 0.772 0.960 0.541 0.761 0.540 0.518 0.441 0.375 ESRmax 10 kHz 20 °C Ω Zmax 100 kHz 20 °C Ω IAC,R 100 kHz 105 °C mA Ordering code (composition see below) 0.541 0.577 0.308 0.308 0.199 0.199 0.169 0.169 0.124 0.124 0.104 0.072 0.077 0.096 0.054 0.076 0.054 0.052 0.044 0.038 0.488 0.500 0.279 0.279 0.180 0.180 0.153 0.153 0.112 0.112 0.094 0.065 0.070 0.087 0.049 0.069 0.049 0.047 0.040 0.034 310 354 519 519 705 705 876 876 1118 1118 1272 1785 1600 1427 2092 1735 2092 2294 2592 2967 B41858C8686M*** B41858C8107M*** B41858C8127M*** B41858C8157M*** B41858C8187M*** B41858C8227M*** B41858C8277M*** B41858C8337M*** B41858C8397M*** B41858E8477M*** B41858C8477M*** B41858C8687M*** B41858D8687M*** B41858E8687M*** B41858C8827M*** B41858D8827M*** B41858C8108M*** B41858C8128M*** B41858C8158M*** B41858C8188M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (for ∅ 16 ... 18 mm) 004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and 18 × 20 ... 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 12 of 33 B41858 Low impedance 105 °C Technical data and ordering codes CR 120 Hz 20 °C µF Case dimensions d×l mm ESRmax 10 kHz 40 °C Ω ESRmax 10 kHz 20 °C Ω Zmax 100 kHz 20 °C Ω IAC,R 100 kHz 105 °C mA Ordering code (composition see below) VR = 100 V DC 22 8 × 11.5 33 10 × 16 47 10 × 20 100 12.5 × 20 120 12.5 × 25 180 12.5 × 30 180 16 × 20 220 16 × 25 270 12.5 × 40 270 18 × 20 330 16 × 31.5 330 18 × 25 390 18 × 31.5 470 18 × 35 560 18 × 35 680 18 × 40 12.219 6.542 3.688 3.048 2.038 1.732 1.313 0.985 1.314 1.260 0.973 1.008 0.720 0.679 0.679 0.438 1.222 0.654 0.461 0.305 0.204 0.173 0.131 0.099 0.131 0.126 0.097 0.101 0.072 0.068 0.068 0.044 1.114 0.589 0.423 0.281 0.188 0.159 0.122 0.091 0.121 0.119 0.090 0.095 0.068 0.063 0.063 0.042 205 357 460 647 864 1009 1119 1402 1309 1220 1546 1477 1907 2061 2061 2683 B41858C9226M*** B41858C9336M*** B41858C9476M*** B41858C9107M*** B41858C9127M*** B41858C9187M*** B41858D9187M*** B41858C9227M*** B41858C9277M*** B41858D9277M*** B41858C9337M*** B41858D9337M*** B41858C9397M*** B41858C9477M*** B41858C9567M*** B41858C9687M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (for d × l = 10 × 20 mm ... 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (for ∅ 16 ... 18 mm) 004 = for J leads, blister (for ∅ 10 ... 18 mm, excluding d × l = 12.5 × 30/40 and 18 × 40 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for d × l = 8 × 11.5 ... 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 20 ... 16 × 31.5 mm and 18 × 20 ... 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 ... 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 33 B41858 Low impedance 105 °C Useful life1) depending on ambient temperature TA under ripple current operating conditions d = 8 mm Useful life1) depending on ambient temperature TA under ripple current operating conditions d ≥ 10 mm 1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life. Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 33 B41858 Low impedance 105 °C Frequency factor of permissible ripple current IAC versus frequency f Please read Cautions and warnings and Important notes at the end of this document. Page 15 of 33 B41858 Low impedance 105 °C Taping, packing and lead configurations Taping Single-ended capacitors are available taped in Ammo pack from diameter 8 to 18 mm as follows: Lead spacing F = 3.5 mm (∅ d = 8 mm) Lead spacing F = 5.0 mm (∅ d = 8 … 12.5 mm) Lead spacing F = 7.5 mm (∅ d = 16 ... 18 mm). The dimensions for F, P1 and 1 max. are specified with reference to the center of the terminal wires. Lead spacing 3.5 mm (∅ d = 8 mm) Last 3 digits of ordering code: 006 Dimensions in mm ∅d 8 F 3.5 H 18.5 W 18.0 W0 9.5 W1 9.0 W2 3.0 P 12.7 P0 12.7 P1 4.6 I1 1.0 Toler- +0.8 ±1.0 ance 0.2 ±0.5 min. ±0.5 max. ±1.0 ±0.3 ±0.6 max. ±0.2 Leads can also run straight through the taping area. Please read Cautions and warnings and Important notes at the end of this document. Page 16 of 33 t 0.7 ∆h 1.0 D0 4.0 max. ±0.2 B41858 Low impedance 105 °C Lead spacing 5.0 mm (∅ d = 8 mm) Last 3 digits of ordering code: 008 Lead spacing 5.0 mm (∅ d = 10 ... 12.5 mm) Last 3 digits of ordering code: 008 Dimensions in mm ∅d 8 H0 16.0 P 12.7 P0 12.7 P1 3.85 I1 t ∆h D0 5.0 19.0 18.0 9.5 9.0 1.5 12.5 11.5 19.0 Toler- +0.8 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ance 0.2 12.7 12.7 3.85 1.0 0.6 1.0 4.0 15.0 15.0 5.0 ±1.0 ±0.2 ±0.5 max. +0.3 max. ±0.2 0.2 F H 20.0 W W0 9.5 10 W1 W2 Taping is available up to dimensions d × l = 12.5 × 25 mm. Please read Cautions and warnings and Important notes at the end of this document. Page 17 of 33 B41858 Low impedance 105 °C Lead spacing 7.5 mm (∅ d = 16 ...18 mm) Last 3 digits of ordering code: 009 Dimensions in mm ∅d 16 F H W 7.5 18.5 18.0 18 Toler0.5 ±0.8 ±0.5 ance +0.75 W0 W1 W2 P P0 P1 I1 t ∆P ∆h D0 12.5 9.0 1.5 30.0 15.0 3.75 1.0 0.7 0 0 4.0 min. ±0.5 max. ±1.0 ±0.2 ±0.5 max. ±0.2 ±1.0 ±1.0 ±0.2 Taping is available up to dimensions d × l = 16 × 31.5 mm and 18 × 31.5 mm. Please read Cautions and warnings and Important notes at the end of this document. Page 18 of 33 B41858 Low impedance 105 °C Cut or kinked leads Single-ended capacitors are available with cut or kinked leads. Other lead configurations also available upon request. Cut leads Last 3 digits of ordering code: 002 With stand-off rubber seal Case size d × l (mm) With flat rubber seal Please read Cautions and warnings and Important notes at the end of this document. Page 19 of 33 Dimensions (mm) a ±0.5 10 × 12.5 5.0 10 × 16 5.0 10 × 20 5.0 12.5 × 20 5.0 12.5 × 25 5.0 16 × 20 7.5 16 × 25 7.5 16 × 31.5 7.5 16 × 35.5 7.5 18 × 20 7.5 18 × 25 7.5 18 × 31.5 7.5 18 × 35 7.5 18 × 40 7.5 B41858 Low impedance 105 °C Kinked leads Last 3 digits of ordering code: 001 With stand-off rubber seal Case size d × l (mm) With flat rubber seal Please read Cautions and warnings and Important notes at the end of this document. Page 20 of 33 Dimensions (mm) a ±0.5 10 × 20 5.0 12.5 × 20 5.0 12.5 × 25 5.0 16 × 20 7.5 16 × 25 7.5 16 × 31.5 7.5 16 × 35.5 7.5 18 × 20 7.5 18 × 25 7.5 18 × 31.5 7.5 18 × 35 7.5 18 × 40 7.5 B41858 Low impedance 105 °C PAPR leads (Protection Against Polarity Reversal) These lead configurations ensure correct placement of the capacitor on the PCB with regard to polarity. PAPR leads are available for diameters from 10 mm up to 18 mm (excluding d × l = 12.5 × 30/35/40 mm). There are three configurations available: Crimped leads, J leads, bent 90° leads. Crimped leads Last 3 digits of ordering code: 003 With stand-off rubber seal With flat rubber seal Suggestion for PCB hole diameter Case size d × l (mm) Dimensions (mm) B ±0.2 C ±0.5 D ±0.1 E ±0.1 16 × 20 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05 16 × 25 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05 16 × 31.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05 16 × 35.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05 18 × 20 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 18 × 25 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 18 × 31.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 18 × 35 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 18 × 40 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 Please read Cautions and warnings and Important notes at the end of this document. Page 21 of 33 a ±0.5 ∅b B41858 Low impedance 105 °C J leads Last 3 digits of ordering code: 004 Suggestion for PCB hole diameter Case size d × l (mm) Dimensions (mm) C ±0.5 E ±0.5 J ±0.2 10 × 12.5 3.2 0.7 1.2 5.0 0.6 ±0.05 10 × 16 3.2 0.7 1.2 5.0 0.6 ±0.05 10 × 20 3.2 0.7 1.2 5.0 0.6 ±0.05 12.5 × 20 3.2 0.7 1.2 5.0 0.6 ±0.05 12.5 × 25 3.2 0.7 1.2 5.0 0.6 ±0.05 16 × 20 3.5 0.7 1.6 7.5 0.8 ±0.05 16 × 25 3.5 0.7 1.6 7.5 0.8 ±0.05 16 × 31.5 3.5 0.7 1.6 7.5 0.8 ±0.05 16 × 35.5 3.5 0.7 1.6 7.5 0.8 ±0.05 18 × 20 3.5 0.7 1.6 7.5 0.8 ±0.1 18 × 25 3.5 0.7 1.6 7.5 0.8 ±0.1 18 × 31.5 3.5 0.7 1.6 7.5 0.8 ±0.1 18 × 35 3.5 0.7 1.6 7.5 0.8 ±0.1 Please read Cautions and warnings and Important notes at the end of this document. Page 22 of 33 a ±0.5 ∅b B41858 Low impedance 105 °C Bent 90° leads for horizontal mounting pinning Last 3 digits of ordering code: 012 Case size d × l (mm) Dimensions (mm) C ±0.5 E ±0.5 F ±0.5 a ±0.5 ∅b 16 × 20 4.0 4.0 12.0 7.5 0.8 ±0.05 16 × 25 4.0 4.0 12.0 7.5 0.8 ±0.05 16 × 31.5 4.0 4.0 12.0 7.5 0.8 ±0.05 16 × 35.5 4.0 4.0 12.0 7.5 0.8 ±0.05 18 × 20 4.0 4.0 13.0 7.5 0.8 ±0.1 18 × 25 4.0 4.0 13.0 7.5 0.8 ±0.1 18 × 31.5 4.0 4.0 13.0 7.5 0.8 ±0.1 18 × 35 4.0 4.0 13.0 7.5 0.8 ±0.1 18 × 40 4.0 4.0 13.0 7.5 0.8 ±0.1 Bent leads for diameter 12.5 mm available upon request. Please read Cautions and warnings and Important notes at the end of this document. Page 23 of 33 B41858 Low impedance 105 °C Packing units and box dimensions Ammo pack Please read Cautions and warnings and Important notes at the end of this document. Case size d×l mm Dimensions (mm) Amax Bmax Cmax Packing units pcs. 8 × 11.5 345 60 240 1000 10 × 12.5 345 60 280 750 10 × 16 345 65 200 500 10 × 20 345 65 200 500 12.5 × 20 345 65 260 500 12.5 × 25 345 65 260 500 16 × 20 320 65 285 300 16 × 25 320 65 285 300 16 × 31.5 320 75 275 300 18 × 20 320 65 285 250 18 × 25 320 65 285 250 18 × 31.5 320 75 275 250 Page 24 of 33 B41858 Low impedance 105 °C Overview of packing units and code numbers for case sizes 8 × 11.5 ... 16 × 35.5 PAPR Case size d×l Taped, Ammo pack mm Standard, bulk pcs. pcs. Kinked leads, bulk pcs. Cut leads, bulk pcs. Crimped J leads, leads, blister blister pcs. pcs. 1000 8 × 11.5 1000 10 × 12.5 1000 750 10 × 16 1000 500 1000 10 × 20 500 500 500 500 12.5 × 20 350 500 350 350 12.5 × 25 250 500 500 500 12.5 × 30 200 12.5 × 35 175 12.5 × 40 175 16 × 20 250 300 200 200 200 200 120 16 × 25 250 300 200 200 200 200 216 16 × 31.5 200 300 250 250 344 344 180 16 × 35.5 100 100 100 150 150 150 The last three digits of the complete ordering code state the lead configuration 000 Code F (mm) d (mm) 001 002 003 004 012 006 008 009 3.5 5 7.5 8 8...12.5 16...18 1) Available upon request Please read Cautions and warnings and Important notes at the end of this document. Page 25 of 33 1000 Bent 90° leads, blister pcs. 675 675 500 300 1) 225 1) B41858 Low impedance 105 °C Overview of packing units and code numbers for case sizes 18 × 20 ... 18 × 40 PAPR Case size d×l Taped, Ammo pack mm Standard, bulk pcs. pcs. Kinked leads, bulk pcs. Cut leads, bulk pcs. Crimped J leads, leads, blister blister pcs. pcs. Bent 90° leads, blister pcs. 18 × 20 175 18 × 25 150 250 175 175 200 200 120 250 150 150 200 200 18 × 31.5 120 100 250 100 100 150 150 120 18 × 35 100 100 100 150 150 150 18 × 40 125 100 100 120 72 The last three digits of the complete ordering code state the lead configuration 000 Code F (mm) d (mm) 001 002 003 004 012 009 Please read Cautions and warnings and Important notes at the end of this document. 7.5 16...18 Page 26 of 33 B41858 Low impedance 105 °C Cautions and warnings Personal safety The electrolytes used by EPCOS have been optimized both with a view to the intended application and with regard to health and environmental compatibility. They do not contain any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide (DMAC). Furthermore, some of the high-voltage electrolytes used by EPCOS are self-extinguishing. As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce operating electrolytes. However, in exceptional cases, such materials must be used in order to achieve specific physical and electrical properties because no alternative materials are currently known. However, the amount of dangerous materials used in our products is limited to an absolute minimum. Materials and chemicals used in EPCOS aluminum electrolytic capacitors are continuously adapted in compliance with the EPCOS Corporate Environmental Policy and the latest EU regulations and guidelines such as RoHS, REACH/SVHC, GADSL, and ELV. MDS (Material Data Sheets) are available on the EPCOS website for all types listed in the data book. MDS for customer specific capacitors are available upon request. MSDS (Material Safety Data Sheets) are available for all of our electrolytes upon request. Nevertheless, the following rules should be observed when handling aluminum electrolytic capacitors: No electrolyte should come into contact with eyes or skin. If electrolyte does come into contact with the skin, wash the affected areas immediately with running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical treatment. Avoid inhaling electrolyte vapor or mists. Workplaces and other affected areas should be well ventilated. Clothing that has been contaminated by electrolyte must be changed and rinsed in water. Please read Cautions and warnings and Important notes at the end of this document. Page 27 of 33 B41858 Low impedance 105 °C Product safety The table below summarizes the safety instructions that must be observed without fail. A detailed description can be found in the relevant sections of chapter "General technical information". Topic Polarity Reverse voltage Mounting position of screwterminal capacitors Robustness of terminals Mounting of single-ended capacitors Soldering Soldering, cleaning agents Upper category temperature Passive flammability Safety information Reference chapter "General technical information" Make sure that polar capacitors are connected 1 with the right polarity. "Basic construction of aluminum electrolytic capacitors" Voltages of opposite polarity should be prevented 3.1.6 by connecting a diode. "Reverse voltage" Screw terminal capacitors must not be mounted 11.1. with terminals facing down unless otherwise "Mounting positions of specified. capacitors with screw terminals" The following maximum tightening torques must 11.3 not be exceeded when connecting screw "Mounting torques" terminals: M5: 2.5 Nm M6: 4.0 Nm The internal structure of single-ended capacitors 11.4 might be damaged if excessive force is applied to "Mounting the lead wires. considerations for Avoid any compressive, tensile or flexural stress. single-ended capacitors" Do not move the capacitor after soldering to PC board. Do not pick up the PC board by the soldered capacitor. Do not insert the capacitor on the PC board with a hole space different to the lead space specified. Do not exceed the specified time or temperature 11.5 limits during soldering. "Soldering" Do not allow halogenated hydrocarbons to come 11.6 into contact with aluminum electrolytic capacitors. "Cleaning agents" Do not exceed the upper category temperature. 7.2 "Maximum permissible operating temperature" Avoid external energy, e.g. fire. 8.1 "Passive flammability" Please read Cautions and warnings and Important notes at the end of this document. Page 28 of 33 B41858 Low impedance 105 °C Topic Safety information Active flammability Maintenance Avoid overload of the capacitors. Storage Make periodic inspections of the capacitors. Before the inspection, make sure that the power supply is turned off and carefully discharge the electricity of the capacitors. Do not apply excessive mechanical stress to the capacitor terminals when mounting. Do not store capacitors at high temperatures or high humidity. Capacitors should be stored at +5 to +35 °C and a relative humidity of ≤ 75%. Breakdown strength Do not damage the insulating sleeve, especially of insulating when ring clips are used for mounting. sleeves Reference chapter "General technical information" 8.2 "Active flammability" 10 "Maintenance" 7.3 "Shelf life and storage conditions" Reference chapter "Capacitors with screw terminals" "Screw terminals accessories" Display of ordering codes for EPCOS products The ordering code for one and the same product can be represented differently in data sheets, data books, other publications and the website of EPCOS, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes. Please read Cautions and warnings and Important notes at the end of this document. Page 29 of 33 B41858 Low impedance 105 °C Symbols and terms Symbol English German C CR CS CS,T Cf d dmax ESL ESR ESRf Capacitance Rated capacitance Series capacitance Series capacitance at temperature T Capacitance at frequency f Case diameter, nominal dimension Maximum case diameter Self-inductance Equivalent series resistance Equivalent series resistance at frequency f Equivalent series resistance at temperature T Frequency Current Alternating current (ripple current) Root-mean-square value of alternating current Ripple current at frequency f Maximum permissible ripple current Rated ripple current Leakage current Operating leakage current Case length, nominal dimension Maximum case length (without terminals and mounting stud) Resistance Insulation resistance Balancing resistance Temperature Temperature difference Ambient temperature Case temperature Capacitor base temperature Time Period Service life (operating hours) Kapazität Nennkapazität Serienkapazität Serienkapazität bei Temperatur T Kapazität bei Frequenz f Gehäusedurchmesser, Nennmaß Maximaler Gehäusedurchmesser Eigeninduktivität Ersatzserienwiderstand Ersatzserienwiderstand bei Frequenz f ESRT f I IAC IAC,RMS IAC,f IAC,max IAC,R Ileak Ileak,op l lmax R Rins Rsymm T ∆T TA TC TB t ∆t tb Please read Cautions and warnings and Important notes at the end of this document. Ersatzserienwiderstand bei Temperatur T Frequenz Strom Wechselstrom Wechselstrom, Effektivwert Wechselstrom bei Frequenz f Maximal zulässiger Wechselstrom Nennwechselstrom Reststrom Betriebsreststrom Gehäuselänge, Nennmaß Maximale Gehäuselänge (ohne Anschlüsse und Gewindebolzen) Widerstand Isolationswiderstand Symmetrierwiderstand Temperatur Temperaturdifferenz Umgebungstemperatur Gehäusetemperatur Temperatur des Gehäusebodens Zeit Zeitraum Brauchbarkeitsdauer (Betriebszeit) Page 30 of 33 B41858 Low impedance 105 °C Symbol V VF Vop VR VS XC XL Z ZT tan δ λ ε0 εr ω English Voltage Forming voltage Operating voltage Rated voltage, DC voltage Surge voltage Capacitive reactance Inductive reactance Impedance Impedance at temperature T Dissipation factor Failure rate Absolute permittivity Relative permittivity Angular velocity; 2 π f German Spannung Formierspannung Betriebsspannung Nennspannung, Gleichspannung Spitzenspannung Kapazitiver Blindwiderstand Induktiver Blindwiderstand Scheinwiderstand Scheinwiderstand bei Temperatur T Verlustfaktor Ausfallrate Elektrische Feldkonstante Dielektrizitätszahl Kreisfrequenz; 2 π f Note All dimensions are given in mm. Please read Cautions and warnings and Important notes at the end of this document. Page 31 of 33 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). Page 32 of 33 Important notes 7. The trade names EPCOS, Alu-X, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 33 of 33