VRLA Rechargeable Battery MPL90-12 Measures Technology Values Innovation Standard Type APPLICATION FEATURES UPS Telecom Golf-Carts Cable TV Power station Marine Maintenance free(no water topping-up required) No free acid(Non-spillable battery) Low self-discharge rate, lower than 3% capacity loss per month Can be used in any orientation(excluding used inverted) The battery is designed with very lower resistance and exceeding high power performance Flame-arrestor is installed to ensure safety Absorbent Glass Mat technology for efficient gas recombination SPECIFICATIONS Nominal Voltage Nominal Capacity Approx. Weight Terminals Internal Resistance Max. Discharge Current Max. Charge Current Cold Cranking Amp @ -18°C Short Circuit Current 12 V 88Ah @ 10 hour rate F.V.(1.75V/cell) ISO 9001 29.8Kg(65.7lbs.) B3 (Fitting M6 bolt & nut) I2 is optional ISO14001 4m (Fully Charged ) 800 A (5 sec.) 26.4 A UL 780 A CE 2450 A o o o o Charge 0 C~50 C(32 F~122 F) Discharge -20oC~60oC(-4oF~140oF) Storage. -20oC~50oC(-4oF~122oF) Container Material PP: UL 94-HB DIMENSION(mm/inch) OUTER DIMENSIONS Length 306±2.0 (12.05±0.08) Width 173±2.0 (6.81±0.08) Container Height 200±2.0 (7.87±0.08) TERMINAL TYPE 306.0±2.0[12.05±0.08] 173.0±2.0[6.81±0.08] 200.0±2.0[7.87±0.08] 230.0±2.0[9.06±0.08] Terminal I2 o Constant power discharge characteristics at 25 C/77 F 1.80V 1.75V 1.70V 1.65V 1.60V F.V. (V/cell) 1.80V 1.75V 1.70V 1.65V 1.60V 24.5(0.96) 11.0(0.43) (M6 BOLT & NUT) 5 Min 10 Min 3117 3494 3726 3878 3993 2291 2459 2560 2639 2690 Unit: W 15 Min 20 Min 25 Min 30 Min 40 Min 50 Min 60 Min 90 Min 1903 2013 2082 2129 2160 1591 1653 1696 1728 1751 1379 1420 1448 1471 1489 1211 1242 1262 1276 1288 975 995 1009 1021 1031 818 835 845 854 861 709 720 728 735 741 504 512 518 522 525 Constant current discharge characteristics at 25 oC/77 oF Discharge Time 7.3(0.29) Terminal Hardware Initial Torque: B3 ,I2(5.5Nm±5%) o F.V. (V/cell) Terminal B3 25.0(0.98) M6x1.0 2.0[0.08] Total Height B3:230±2.0 (9.06±0.08) I2:207±2.0 (8.15±0.08) Discharge Time IEC60896-21/22 JIS C 8704-2 GB/T 19638.2 7.0(0.28) Operating Temperature Range Unit: A 5 Min 10 Min 15 Min 20 Min 25 Min 30 Min 40 Min 50 Min 60 Min 90 Min 290 318 339 352 363 201 217 226 233 237 165 174 180 185 188 136 142 146 149 151 116 121 124 126 128 101 105 107 109 110 81 83 85 86 87 68 70 71 72 72 59.6 60.5 61.2 61.8 62.2 42.3 43.0 43.5 43.9 44.2 All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto. A/1 REV. Jan. 2011 Powered by B.B. Battery Co., Ltd.