Alpha Wire HR04GW101 M8 male to m8 90 degree female Datasheet

Customer Specification
PART NO: HR04GW101
M8 Male to M8 90 Degree Female
Drawings
Issue: 1 Issue Date: 7/29/2016 Effective Date: 7/29/2016
Technical Data
Cordage Construction
Cordage Part Number
Component 1
a) Conductor
b) Insulation
Insulation Colors
Jacket
a) Color(s)
Cord Configuration
End 1
End 2
Insert
Mold Color
Contact
Coupling Nut
Available Lengths
Applicable SpecificationsCable
UL
CSA International
Applicable SpecificationsCord Set
UL
Diameters (In)
101
4 COND
22 (26/36) AWG Bare Copper
0.010” Wall, Nom. mPPE
Black, White, Brown & Blue
0.040” Wall, Nom. PUR, Zero Halogen
SLATE
0.027
0.047
0.200
M8 Male
Cut End
Black TPU
Black TPU
Copper Alloy, Gold plated
Copper Alloy, Nickel plated
0.6, 1, 3, 5, 10, 15, 20 Meters
AWM/STYLE 20549
AWM/STYLE 21959
C(RU) AWM I/II A/B FT1
80°C / 300 V RMS
90°C / 600 V RMS
90°C / 600 V RMS
ANSI/UL 2238, Cable Assembly Extension
RU, UL File Number E485156
•••••••••••••••••••••••••••••••••••••••
Alpha Wire | 711 Lidgerwood Ave, Elizabeth, NJ 07207
www.alphawire.com | 1-800-52 ALPHA
1
Customer Specification
PART NO: HR04GW101
M8 Male to M8 90 Degree Female
CSA
Nominal Voltage
Rated Voltage
Ingress Protection
Environmental Compliance
CE
REACH Regulation (EC
1907/2006)
Physical & Mechanical
Properties
Temperature Range, Cord
Bend Radius
Pull Tension
Current Rating
Ordering Information
HR04GW101 SL355
HR04GW101 SL356
HR04GW101 SL357
HR04GW101 SL358
HR04GW101 SL359
HR04GW101 SL400
HR04GW101 SL401
Standard Package
CSA-C22.2 No. 182.3, Special Use
Attachment Plugs, Receptacles and
Connectors
cRU, UL File Number E485156
30 V
36 V
IP67/NEMA 6P
All materials used in the manufacture of
this part meet the requirements of
European Directive 2011/65/EU regarding
the restriction of use of certain hazardous
substances in electrical and electronic
equipment. Exemption used; 6a.
This product does not contain Substances
of Very High Concern (SVHC) listed on the
European Union’s REACH candidate list in
excess of 0.1% mass of the item.
-50 to 90°C(static), -40 to 80°C (dynamic)
4X Cable Diameter (static), 6X Cable
Diameter (dynamic)
20.4 Lbs, Maximum
2.2 Amps @ 50°C
0.6 Meters
1.0 Meters
3.0 Meters
5.0 Meters
10.0 Meters
15.0 Meters
20.0 Meters
Each
Although Alpha Wire (“Alpha”) makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Alpha provides the information and specification herein on an “AS IS” basis, with no
representations or warranties, whether express, statutory or implied. In no event will Alpha be liable any damages (including consequential,
indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Alpha has been advised of the possibility of such damages,
whether in an action under contact, negligence or any other theory, arising out of or in connection with the use, or inability to use, the
information or specification described herein.
•••••••••••••••••••••••••••••••••••••••
Alpha Wire | 711 Lidgerwood Ave, Elizabeth, NJ 07207
www.alphawire.com | 1-800-52 ALPHA
2