MPD MA512S12RW Ma500rw sery Datasheet

MA500RW Series
Wide 2:1 Input, 5W,
High Performance, DIP
DC/DC Converters
Electrical Specifications
Key Features:
• 5W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
Input Voltage Range
• 30 Standard Models
• High Efficiency
• Compact DIP Case
• -40°C to +85°C Operation
Typ.
Max.
9.0
12.0
18.0
24 VDC Input
18.0
24.0
36.0
48 VDC Input
36.0
48.0
72.0
Input Reflected Ripple Current
35
VDC
mA P - P
Output
Parameter
Conditions
Output Voltage Accuracy
• Low Cost
Line Regulation
Min.
Typ.
Max.
Units
±1.0
%
VIN = Min to Max
±0.5
%
Load Regulation
IOUT = 25% to 100%
±0.5
%
Load Regulation
See Note 1
±0.5
%
Ripple & Noise (20 MHz)
See Note 2
60
mV P - P
±0.02
%/°C
Temperature Coefficient
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Isolation Voltage, See Note 3
3.5 kV Isolation
Models
Available
Units
(Pi) Filter
Input Filter
• Metal Case Available
Alternate
Pin-Out
Available
Min.
12 VDC Input
Isolation Resistance
Isolation Capacitance
Min.
3 Seconds
1,500
500 VDC
1,000
100 kHz/0.1V
Switching Frequency
Typ.
Max.
Units
VDC
M
60
100
pF
400
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Operating Temperature Range
Min.
Typ.
Max.
Units
-40
+25
+85
°C
+100
°C
+125
°C
95
%
Case
Storage Temperature Range
-40
Cooling
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Case Material, Plastic
Non-Conductive Black Plastic (UL94-V0)
Weight, Plastic Case
0.44 Oz (12.5g)
MicroPower Direct
Case Material, Metal
Nickel-Coated Copper With Non-Conductive Base (UL94-V0)
292 Page Street
Suite D
Stoughton, MA 02072
USA
Reliability Specifications
Weight, Metal Case
0.53 Oz (15g)
Parameter
Conditions
MTBF
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
MIL HDBK 217F, 25°C, Gnd Benign
Min.
Typ.
Max.
1.0
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
Max.
12 VDC Input
-0.7
24.0
24 VDC Input
-0.7
40.0
48 VDC Input
-0.7
80.0
1.5 mm From Case for 10 Sec
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
Range
Output
Current (mA)
Voltage Current
(mA, Max)
Full-Load No-Load (VDC)
MA512S-05RW-xx
12
9.0 - 18.0
563
20
MA512S-09RW-xx
12
9.0 - 18.0
541
20
MA512S-12RW-xx
12
9.0 - 18.0
534
20
MA512S-15RW-xx
12
9.0 - 18.0
534
20
MA512S-24RW-xx
12
9.0 - 18.0
556
MA512D-05RW-xx
12
9.0 - 18.0
MA512D-09RW-xx
12
MA512D-12RW-xx
5.0
Current
Efficiency
(mA, Min)
(%, Typ)
Fuse
Reflected Capacitive
Ripple
Rating
Load
Current
Slow-Blow
(µF, Max)
(mA Typ)
(mA)
1,000.0
250.0
74
35.0
2,200
1,000
9.0
555.0
139.0
77
35.0
470
1,000
12.0
417.0
104.0
78
35.0
470
1,000
15.0
333.0
83.0
78
35.0
470
1,000
20
24.0
208.0
52.0
75
35.0
220
1,000
579
20
±5.0
±500.0
±125.0
72
35.0
±1,000
1,000
9.0 - 18.0
548
20
±9.0
±278.0
±70.0
76
35.0
±220
1,000
12
9.0 - 18.0
541
20
±12.0
±208.0
±52.0
77
35.0
±220
1,000
MA512D-15RW-xx
12
9.0 - 18.0
541
20
±15.0
±167.0
±42.0
77
35.0
±220
1,000
MA512D-24RW-xx
12
9.0 - 18.0
548
20
±24.0
±104.0
±26.0
76
35.0
±100
1,000
MA524S-05RW-xx
24
18.0 - 36.0
278
12
5.0
1,000.0
250.0
75
35.0
2,200
500
MA524S-09RW-xx
24
18.0 - 36.0
274
12
9.0
555.0
139.0
76
35.0
470
500
MA524S-12RW-xx
24
18.0 - 36.0
271
12
12.0
417.0
104.0
77
35.0
470
500
MA524S-15RW-xx
24
18.0 - 36.0
267
12
15.0
333.0
83.0
78
35.0
470
500
MA524S-24RW-xx
24
18.0 - 36.0
274
12
24.0
208.0
52.0
76
35.0
220
500
MA524D-05RW-xx
24
18.0 - 36.0
282
12
±5.0
±500.0
±125.0
74
35.0
±1,000
500
MA524D-09RW-xx
24
18.0 - 36.0
274
12
±9.0
±278.0
±70.0
76
35.0
±220
500
MA524D-12RW-xx
24
18.0 - 36.0
267
12
±12.0
±208.0
±52.0
78
35.0
±220
500
MA524D-15RW-xx
24
18.0 - 36.0
267
12
±15.0
±167.0
±42.0
78
35.0
±220
500
MA524D-24RW-xx
24
18.0 - 36.0
278
12
±24.0
±104.0
±26.0
75
35.0
±100
500
MA548S-05RW-xx
48
36.0 - 72.0
135
8
5.0
1,000.0
250.0
77
35.0
2,200
250
MA548S-09RW-xx
48
36.0 - 72.0
134
8
9.0
555.0
139.0
78
35.0
470
250
MA548S-12RW-xx
48
36.0 - 72.0
130
8
12.0
417.0
104.0
80
35.0
470
250
MA548S-15RW-xx
48
36.0 - 72.0
130
8
15.0
333.0
83.0
80
35.0
470
250
MA548S-24RW-xx
48
36.0 - 72.0
135
8
24.0
208.0
52.0
77
35.0
220
250
MA548D-05RW-xx
48
36.0 - 72.0
137
8
±5.0
±500.0
±125.0
76
35.0
±1,000
250
MA548D-09RW-xx
48
36.0 - 72.0
134
8
±9.0
±278.0
±70.0
78
35.0
±220
250
MA548D-12RW-xx
48
36.0 - 72.0
134
8
±12.0
±208.0
±52.0
78
35.0
±220
250
MA548D-15RW-xx
48
36.0 - 72.0
130
8
±15.0
±167.0
±42.0
80
35.0
±220
250
MA548D-24RW-xx
48
36.0 - 72.0
135
8
±24.0
±104.0
±26.0
77
35.0
±100
250
Notes:
1. Cross regulation is measured with the output being tested at 100% load while the other output
is varied from 25% to 100% load.
2. See the typical connection circuit on page three for typical external filtering components. For help with a
specific model or layout issue, contact the factory.
3. Isolation voltage is specified for Input to output. On units with the optional metal case, the isolation voltage
for Input - Case and Output - Case is 1,000 VDC.
4. Operation at no-load will not damage the unit, but they may not meet all specifications. To meet all specifications, a minimum load of 25% should be maintained.
5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection
table above for the correct rating.
For the alternate pin-out (see page 4) , add suffix “P2” to model number
(i.e. MA524S-05RW-P2)
Model Number
Derating Curve
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Typical Connection
The diagram above illustrates a typical connection of the MA500RW
series for applications that require meeting conducted EMC standards.
The units do not require external components to operate as specified.
For applications requiring very low output noise levels, the output
filtering capacitors (C3 is a low ESR electrolytic & C4 is a ceramic) will
often be sufficient. Care must be taken in choosing output capacitors
not to exceed the capacitive load specification for the unit. For dual
output units, output capacitors should be connected from each output
to common. All external components should be mounted as close to
the unit as possible.
The recommended values for components are:
Component
24 VIN
48 VIN
12 VIN
C1
220 µF/50V
220 µF/100V
220 µF/100V
LCM
12 µH
12 µH
12 µH
--470 pF/2kV MLCC 470 pF/2kV MLCC
C2
100 µF
100 µF
100 µF
C3
4.7 - 10 µF
4.7 - 10 µF
4.7 - 10 µF
C4
Typical Board Layout: With External Filter Components, Single Output
Typical Board Layout: With External Filter Components, Dual Output
Input noise and surge suppression modules are available for a number
of MPD DC/DC power supplies. Contact the factory for more information.
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Standard Units - Plastic Case
Standard Units - Metal Case
Pin Connections
s
Pin
2
3
9
11
14
16
22
23
Single Output
-VIN
-VIN
No Pin
No Connection
+VOUT
-VOUT
+VIN
+VIN
Pin
2
3
9
11
14
16
22
23
Dual Output
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
+VIN
For the alternate pin-out, add suffix “P2” to model number
(i.e. MA524S-05RW-P2)
Alternate Pin-Out Units - Plastic Case
Alternate Pin-Out Units - Metal Case
Pin Connectio
tions
Pin
1
2
3
10
11
12
13
14
15
22
23
24
Single Output
+VIN
No Connection
No Connection
-VOUT
+VOUT
-VIN
-VIN
+VOUT
-VOUT
No Connection
No Connection
+VIN
Pin
1
2
3
10
11
12
13
14
15
22
23
24
Dual Output
+VIN
-V
VOUT
Common
Common
+VOUT
-VIN
-VIN
+VOUT
Common
Common
-VOUT
+VIN
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages