Datasheet DC Brushless Fan Motor Drivers Multifunction Single-phase Full-wave Fan Motor Driver BD6994FV Key Specifications Operating Voltage Range: Operating Temperature Range: Output Voltage (Total): General Description BD6994FV is a 1chip driver for 12V single-phase full-wave fan motor. This IC employs the Bi-CMOS process and incorporates various functions such as low ON resistance, low power consumption and quiet drive. Package SSOP-B16 Features SSOP Small Package BTL Soft Switching Drive Stand-by Function Speed Controllable by DC / Pulse Input Quick Start Duty Control Start-up Function Lock Protection and Automatic Restart (without External Capacitor) Rotation Speed Pulse Signal (FG) Output Lock Alarm Signal(AL) Output Application Fan motors for general consumer equipment of desktop PC, Projector, etc. Absolute Maximum Ratings Parameter Symbol Supply Voltage Power Dissipation Operating Temperature Range Storage Temperature Range Output Voltage Output Current Signal(FG/AL) Output Voltage Signal(FG/AL) Output Current Reference Voltage(REF) Output Current Hall Bias(HB) Output Current 1 Hall Bias(HB) Output Current 2 Input Voltage(H+, H–, TH, MIN, SEL, PS) Junction Temperature VCC Pd Topr Tstg VO IO VFG/VAL IFG/IAL IREF IHB1 IHB2 VIN Tjmax Limit 20 0.87 (Note 1) -40 to +105 -55 to +150 20 1.2 (Note 2) 20 10 5 12 (Note 3) 5 (Note 4) 7 150 4.5V to 17V -40°C to +105°C 0.6V(Typ) at 0.4A W (Typ) x D (Typ) x H (Max) 5.00mm x 6.40mm x 1.35mm SSOP-B16 Unit V W °C °C V A V mA mA mA mA V °C (Note 1) Derate by 7.0mW/°C if operating over Ta=25°C. (On 70.0mm×70.0mm×1.6mm glass epoxy board) (Note 2) Do not exceed Pd and Tjmax. (Note 3) Ta=0°C or Higher. (Note 4) Less than Ta=0°C. Caution: Operating the IC over the absolute maximum ratings may damage the IC. The damage can either be a short circuit between pins or an open circuit between pins and the internal circuitry. Therefore, it is important to consider circuit protection measures, such as adding a fuse, in case the IC is operated over the absolute maximum ratings. Recommended Operating Conditions Parameter Operating Supply Voltage Range Operating Input Voltage Range 1(H+, H–) (VCC≥9V) Operating Input Voltage Range 1(H+, H–) (VCC<9V) Operating Input Voltage Range 2(TH, MIN) ○Product structure:Silicon monolithic integrated circuit www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・14・001 Symbol VCC VIN1 VIN2 Limit 4.5 to 17.0 0.4 to 3 0.4 to VCC/3 0.4 to VREF Unit V V V V ○This product has no designed protection against radioactive rays 1/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Pin Configuration Pin Description P/No. P/Name 1 GND 2 OUT2 3 VCC 4 MIN 5 TH 6 OSC 7 FG 8 AL 9 H+ 10 HB 11 H– 12 REF (TOP VIEW) GND 1 16 GND OUT2 2 15 OUT1 VCC 3 14 PS MIN cc 4 13 SEL TH 5 12 REF OSC 6 11 H– FG 7 10 HB AL 8 9 H+ Figure 1. Pin Configuration 13 SEL 14 15 16 PS OUT1 GND Function Ground pin Motor output 2 pin Power supply pin Minimum output duty setting pin Output duty controllable input pin Oscillating capacitor connecting pin Speed pulse signal output pin Lock alarm signal output pin Hall + input pin Hall bias pin Hall - input pin Reference voltage output pin Duty control start up function selecting pin Power save pin Motor output 1 pin Ground pin Block Diagram GND 1 OUT2 2 GND HALL AMP HALL AMP 16 OUT1 15 INTERNAL REG VCC 3 MIN 4 TH 5 STANDBY PWM COMP FUNCTION SELECTOR PWM COMP REF PS SEL 14 13 REF 12 CONTROL OSC 6 FG 7 AL 8 I/O Truth Table Hall Input H+ H– H L L H LOGIC OSC QUICK START SIGNAL OUTPUT LOCK PROTECT HALL COMP H– 11 HALL BIAS HB 10 TSD H+ 9 Figure 2. Block Diagram OUT1 Driver Output OUT2 FG L H H L Hi-Z L H; High, L; Low, Hi-Z; High impedance FG output is open-drain type. Motor State Rotating Locking Stand-by FG Output Hi-Z AL Output L Hi-Z L L; Low, Hi-Z; High impedance AL output is open-drain type. www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 2/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Electrical Characteristics (Unless otherwise specified, Ta=25°C, VCC=12V) Limit Parameter Symbol Unit Min Typ Max Circuit Current Circuit Current(Stand-by) Hall Bias Voltage Hall Input Offset Voltage Input-Output Gain ICC ISTBY VHB VOFS GIO 70 1.05 46.0 6.5 160 1.25 48.5 9.5 250 1.45 ±8 51.0 mA μA V mV dB Output Voltage VO - 0.6 0.9 V Lock Detection ON Time Lock Detection OFF Time Lock Detection OFF/ON Ratio FG Hysteresis Voltage FG Output Low Voltage FG Output Leak Current AL Output Low Voltage AL Output Leak Current OSC Frequency(Reference Data) OSC Charge Current OSC Discharge Current OSC High Voltage OSC Low Voltage tON tOFF RLCK VHYS VFGL IFGL VALL IALL FOSC ICOSC IDOSC VOSCH VOSCL 0.3 3.0 8.5 ±7 -16 6 3.4 1.3 0.5 5.0 10 ±12 0.2 0.2 26 -11 11 3.6 1.5 0.7 7.0 11.5 ±17 0.3 10 0.3 10 -6 16 3.8 1.7 s s mV V μA V μA kHz μA μA V V Output ON Duty 1 DOH1 70 80 90 % Output ON Duty 2 DOH2 40 50 60 % Output ON Duty 3 DOH3 10 20 30 % Re-Circulate Ratio(Reference Data) Reference Voltage TH Input Bias Current MIN Input Bias Current SEL Input Open Voltage SEL Input Low Level SEL Input Bias Current PS Input Open Voltage PS Input Low Level PS Input High Level PS Input Bias Current Limit ON Duty at Start-up Limit ON Duty Time at Start-up Start Assist Duty 1 Start Assist Duty 2 RRC VREF ITH IMIN VSEL VSELL ISEL VPS VPSL VPSH IPS DOHL tOHL DOHS1 DOHS2 4.8 -0.6 -0.6 2.9 -0.3 -35 4.2 -0.3 2.5 -35 43 0.3 23 43 50 5.1 3.2 -25 4.7 -25 53 0.5 33 53 5.4 3.5 0.8 -15 5.2 0.8 5.5 -15 63 0.7 43 53 % V μA μA V V μA V V V μA % s % % Conditions PS=0V IHB=-2mA IO=±400mA High and low side total RLCK=TOFF / TON IFG=5mA VFG=17V IAL=5mA VAL=17V COSC=100pF VTH=1.8V Output 1kΩ load VTH=2.4V Output 1kΩ load VTH=3.1V Output 1kΩ load VTH=1.65V IREF=-2mA VTH=0.2V VMIN=0.2V VSEL=0V VPS=0V VSEL=0V, VTH<VREF-0.5V VSEL=0V, VTH<VREF-0.5V VSEL=0V, VTH>VREF-0.1V SEL=OPEN, VTH>VREF-0.1V For parameters involving current, positive nations means inflow of current to IC while negative nation means outflow of current from IC. The reference data is a design guaranteed value and the numerical all shipment inspection off the subject item. www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 3/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) 400 10 105°C 25°C 6 -40°C 4 Circuit Current: ISTBY[μA] Circuit Current: ICC [mA] 8 2 300 105°C 200 25°C -40°C 100 Operating Voltage Range Operating Voltage Range 0 0 5 10 15 20 0 5 10 15 20 Supply Voltage: VCC [V] Supply Voltage: VCC [V] Figure 3. Circuit Current vs Supply Voltage (In Operation) Figure 4. Circuit Current vs Supply Voltage (In Standby) 1.45 1.45 1.35 1.35 105°C 25°C -40°C 1.25 1.15 Hall Bias Voltage: VHB[V] Hall Bias Voltage: VHB[V] 0 105°C 1.25 25°C -40°C 1.15 Operating Voltage Range 1.05 1.05 0 5 10 15 20 0 Supply Voltage: VCC [V] 4 6 8 10 HB Source Current: IHB[mA] Figure 5. Hall Bias Voltage vs Supply Voltage (IHB=-2mA) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 2 Figure 6. Hall Bias Voltage vs HB Source Current (VCC=12V) 4/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) - Continued 51 Input-Output Gain: GIo[dB] Hall Input Offset Voltage: VOFS[V] 10 5 -40°C 25°C 105°C 0 -5 50 49 105°C 25°C 48 -40°C 47 Operating Voltage Range Operating Voltage Range -10 46 0 5 10 15 20 0 10 15 20 Supply Voltage: VCC [V] Supply Voltage: VCC [V] Figure 7. Hall Input Offset Voltage vs Supply Voltage Figure 8. Input-Output Gain vs Supply Voltage 0 Output High Voltage: VOH [V] 0 Output High Voltage: VOH [V] 5 -0.4 105°C 25°C -0.8 -40°C -1.2 -0.4 -0.8 17V 12V 4.5V -1.2 0 0.4 0.8 1.2 0 0.4 0.8 1.2 Output Source Current: IO[A] Output Source Current: IO[A] Figure 9. Output High Voltage vs Output Source Current (VCC=12V) Figure 10. Output High Voltage vs Output Source Current (Ta=25°C) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 5/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) - Continued 1 1 0.8 0.8 105°C 25°C Output Low Voltage: VOL[V] Outpur Low Voltage: VOL[V] 4.5V 0.6 -40°C 0.4 0.2 0.6 12V 17V 0.4 0.2 0 0 0 0.4 0.8 0 1.2 0.8 1.2 Output Sink Current: IO[A] Output Sink Current: IO[A] Figure 11. Output Low Voltage vs Output Sink Current (VCC=12V) Figure 12. Output Low Voltage vs Output Sink Current (Ta=25°C) 7.0 0.6 -40°C 0.5 25°C 105°C 0.4 Lock Detection OFF Time: t OFF [s] 0.7 Lock Detection ON Time: t ON [s] 0.4 6.0 -40°C 5.0 25°C 105°C 4.0 Operating Voltage Range Operating Voltage Range 0.3 3.0 0 5 10 15 20 0 Supply Voltage: VCC [V] 10 15 20 Supply Voltage: VCC [V] Figure 13. Lock Detection ON Time vs Supply Voltage www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 5 Figure 14. Lock Detection OFF Time vs Supply Voltage 6/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) - Continued 60 FG Hystresis voltage: VHYS [V] Lock Detection OFF/ON Ratio: R LCK[s/s] 12.0 11.0 -40°C 25°C 105°C 10.0 9.0 40 105°C 20 25°C -40°C 0 -40°C 25°C -20 105°C -40 Operating Voltage Range Operating Voltage Range -60 8.0 0 5 10 15 0 20 5 10 15 20 Supply Voltage: VCC [V] Supply Voltage: VCC [V] Figure 15. Lock Detection OFF/ON Ratio vs Supply Voltage Figure 16. FG Hysteresis Voltage vs Supply Voltage 0.8 FG Output Low Voltage: VFGL[V] FG Output Low Voltage: VFGL[V] 0.8 0.6 105°C 0.4 25°C -40°C 0.2 0.6 0.4 4.5V 17V 12V 0.2 0 0 0 2 4 6 8 0 10 4 6 8 10 FG Sink Current: IFG[mA] FG Sink Current: IFG[mA] Figure 17. FG Output Low Voltage vs FG Sink Current (VCC=12V) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 2 Figure 18. FG Output Voltage vs FG Sink Current (Ta=25°C) 7/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) - Continued 0.8 AL Output Low Voltage: VALL[V] FG Output Leak Current: IFGL[μA] 8 6 4 2 0 Operating Voltage Range 105°C 25°C -40°C -2 0.6 105°C 0.4 25°C -40°C 0.2 0 0 5 10 15 20 0 FG Voltage: VFG[V] 4 6 8 10 AL Sink Current: IAL[mA] Figure 19. FG Output Leak Current vs FG Voltage Figure 20. AL Output Low Voltage vs AL Sink Current (VCC=12V) 0.8 0.8 AL Output Leak Current: IALL[μA] AL Output Low Voltage: VALL[V] 2 0.6 0.4 4.5V 17V 12V 0.2 0.6 0.4 0.2 0 Operating Voltage Range 0 105°C 25°C -40°C -0.2 0 2 4 6 8 10 0 AL Sink Current: IAL[mA] 5 10 15 20 AL Voltage: VAL[V] Figure 22. AL Output Leak Current vs AL Voltage Figure 21. AL Output Low Voltage vs AL Sink Current (Ta=25°C) 回路電流 vs 電源電圧 www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 8/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) – Continued 40 OSC Charge/Discharge Current: ICOSC/IDOSC[μA] OSC Frequency: fOSC [kHz] 50 40 30 105°C 25°C -40°C 20 10 Operating Voltage Range 0 20 105°C 25°C -40°C 0 -40°C 25°C 105°C -20 Operating Voltage Range -40 0 5 10 15 20 0 5 Supply Voltage: VCC [V] 15 20 Supply Voltage: VCC [V] Figure 24. OSC Charge/Discharge Current vs Supply Voltage Figure 23. OSC Frequency vs Supply Voltage (Reference Data; COSC=100pF) 4.5 100 14V 105°C 25°C -40°C 3.5 2.5 105°C 25°C -40°C 1.5 Re-Circulate Ratio: R RC [%] OSC High/Low Voltage: VOSCH /VOSCL[V] 10 75 OSC Width 12V 50 25 10V Operating Voltage Range 0.5 0 0 5 10 15 20 0 Supply Voltage: VCC [V] 1 2 3 4 TH Voltage: VTH [V] Figure 25. OSC High/Low Voltage vs Supply Voltage Figure 26. Re-Circulate Ratio vs TH Voltage (Reference Data; Ta=25°C) pF) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 9/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) – Continued 6.0 105°C 25°C -40°C Reference Voltage: VREF [V] Re-Circulate Ratio: R RC [%] 100 75 50 25 105°C 25°C 5.0 -40°C 4.0 3.0 Operating Voltage Range Operating Voltage Range 0 2.0 0 5 10 15 20 0 Supply Voltage: VCC [V] 10 15 20 Supply Voltage: VCC [V] Figure 27. Re-Circulate Ratio vs Supply Voltage (Reference Data; VTH=1.65V) Figure 28. Reference Voltage vs Supply Voltage (IREF=-2mA) 6 0.00 5.5 -0.15 105°C 25°C 5 -40°C 4.5 TH Bias Current: I TH[μA] Reference Voltage: VREF [V] 5 105°C 25°C -40°C -0.30 -0.45 Operating Voltage Range 4 -0.60 0 2 4 6 8 10 0 REF Source Current: IREF [mA] 10 15 20 Supply Voltage: VCC [V] Figure 30. TH Bias Current vs Supply Voltage Figure 29. Reference Voltage vs REF Source Current (VCC=12V) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 5 10/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) – Continued 4 105°C 25°C -40°C -0.15 SEL Input Open Voltage: VSEL[V] MIN Bias Current: IMIN[μA] 0.00 -0.30 -0.45 3.5 105°C 25°C -40°C 3 2.5 Operating Voltage Range Operating Voltage Range -0.60 2 0 5 10 15 20 0 Supply Voltage: VCC [V] 10 15 20 Supply Voltage: VCC [V] Figure 31. MIN Bias Current vs Supply Voltage Figure 32. SEL Input Open Voltage vs Supply Voltage 2 -5 1.7 105°C 25°C -40°C 1.4 1.1 SEL Input Bias Current: I SEL[μA] SEL Input Threshold Voltage: VSELL[V] 5 -10 -15 -40°C -20 25°C -25 105°C Operating Voltage Range Operating Voltage Range 0.8 -30 0 5 10 15 20 0 Supply Voltage: VCC [V] 10 15 20 Supply Voltage: VCC [V] Figure 33. SEL Input Threshold Voltage vs Supply Voltage www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 5 Figure 34. SEL Input Bias Current vs Supply Voltage 11/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) – Continued 2 105°C 25°C -40°C PS Input High/Low Threshold Voltage: VPSH/VPSL[V] PS Input Open Voltage: VPS[V] 5 4 3 Operating Voltage Range 105°C 25°C -40°C 105°C 25°C -40°C 1.75 1.5 1.25 Operating Voltage Range 2 1 0 5 10 15 20 0 Supply Voltage: VCC [V] 10 15 20 Supply Voltage: VCC [V] Figure 35. PS Input Open Voltage vs Supply Voltage Figure 36. PS Input High/Low Threshold Voltage vs Supply Voltage -10 65 Limit ON Duty at Start-up: D OH [%] PS Input Bias Current: I PS[μA] 5 -40°C -20 25°C 105°C -30 -40 60 55 -40°C 25°C 105°C 50 45 Operating Voltage Range Operating Voltage Range -50 40 0 5 10 15 20 0 Supply Voltage: VCC [V] Figure 37. PS Input Bias Current vs Supply Voltage www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 5 10 15 20 Supply Voltage: VCC [V] Figure 38. Limit ON Duty Time at Start-up vs Supply Voltage 12/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Typical Performance Curves (Reference Data) – Continued 45 0.6 Start Assist Duty 1: D OHS1[%] Limit ON Duty Time at Startup : t OH [s] 0.7 -40°C 0.5 25°C 105°C 0.4 0.3 40 35 105°C 25°C -40°C 30 25 Operating Voltage Range Operating Voltage Range 0.2 20 0 5 10 15 0 20 Supply Voltage: VCC [V] 5 10 15 20 Supply Voltage: VCC [V] Figure 39. Limit ON Duty Time at Start-up vs Supply Voltage Figure 40. Start Assist Duty 1 vs Supply Voltage Start Assist Duty 2: D OHS2[%] 65 60 55 -40°C 25°C 105°C 50 45 Operating Voltage Range 40 0 5 10 15 20 Supply Voltage: VCC [V] Figure 41. Start Assist Duty 2 vs Supply Voltage www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 13/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Application Circuit Example (Constant Values are for Reference) 1. PWM Input Application 1(Use of stand-by function) This is an example application circuit for converting the external PWM duty into DC voltage, and controlling the rotational speed. Bypass capacitor, must be connected near to VCC Terminal as much as possible Maximum output voltage and current are 20V and 1.2A. M - 1 Reverse polarity protection 2 + 3 Circuit that converts PWM duty into DC voltage. Take into consideration the operating input voltage range of TH terminal. . OUT2 HALL AMP HALL AMP OUT1 16 15 From PWM Terminal Internal REG 1μF to HALL BIAS GND GND 4 Vcc STANDBY PWM COMP MIN FUNCTION SELECTOR PWM COMP 5 TH REF Input PWM signal into PS terminal. Stand-by function can be used. Use only PUSH-PULL input signal. 14 PS SEL Limit ON duty at start up setting SEL=OPEN: Disable SEL=10kΩ: Enable 13 REF to 10kΩ Stabilization of REF voltage 12 Hall bias is set according to the amplitude of hall element output and hall input voltage range. CONTROL PWM LOGIC 6 To PS(14Pin) 0Ω to OSC OSC 0.1μF to HALL COMP H– 11 100pF SIG 7 FG QUICK START AL SIGNAL OUTPUT 0Ω to HB 10 HALL BIAS H Protection of FG open-drain 0Ω to SIG 8 LOCK PROTECT H+ TSD 9 Input bypass capacitor to reduce noise in the input. Output PWM frequency setting Figure 42. Application of Converting PWM Duty to DC Voltage Substrate Design Note a) IC power, motor outputs, and motor ground lines are made as wide as possible. b) The bypass capacitor and/or Zener diode are connected near to VCC terminal. c) H+ and H– lines are arranged side by side and connected from the hall element to the IC as short as possible, because it is easy for the noise to influence the hall lines. 10 HB AL 8 SIG c) H 9 H+ 10 HB AL 8 9 H+ FG 7 SIG c) H FG 7 11 H– 11 H– a) Long lines 12 REF a) Short lines + VCC 3 12 REF Far From IC b) 14 PS 4 MIN b) 4 MIN OUT1 15 6 OSC OUT2 2 M OUT2 2 5 TH GND PWM Near to IC 14 PS OUT1 15 6 OSC + VCC 3 M a) a) SEL 13 5 TH GND PWM 1 16 a) SEL 13 1 16 a) a) a) - Figure 43. Bad Layout Image of the Substrate www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 - Figure 44. Good Layout Image of the Substrate 14/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Application Circuit Example (Constant Values are for Reference) 2. DC Voltage Input Application 1 This is an example application circuit for fixed rotation speed control by DC voltage. In this application, minimum rotational speed cannot be set. Moreover, output duty changes depending on the TH voltage. Function of limit ON duty at start up can be set using the SEL terminal. M - 1 2 GND GND OUT2 HALL AMP HALL AMP 3 VCC MIN terminal is pulled up to REF terminal. The minimum output duty setting is invalid. 15 Internal REG 1μF to + OUT1 16 4 STANDBY PWM COMP MIN to 10kΩ PS FUNCTION SELECTOR SEL PWM COMP 5 TH REF REF 14 13 Limit ON duty at start up SEL=OPEN: Disable SEL=10kΩ: Enable to 10kΩ 12 CONTROL Set TH voltage less than OSC high (typ. 3.6V) LOGIC 6 0Ω to OSC OSC 0.1μF to HALL COMP H– 11 100pF SIG 7 0Ω to SIG 8 FG QUICK START AL SIGNAL OUTPUT HB 10 HALL BIAS LOCK PROTECT H+ TSD 0Ω to H 9 Figure 45. Application of DC Voltage Input 1 3. DC Voltage Input Application 2 This is an example application circuit for fixed rotation speed control by DC voltage. In this application, output duty changes depending on the MIN voltage. Function of Start Duty Assist can be set using the SEL terminal. M - 1 2 GND GND OUT2 HALL AMP HALL AMP 3 VCC MIN terminal is pulled up to REF terminal. The minimum output duty setting is invalid. 4 MIN STANDBY PWM COMP FUNCTION SELECTOR PWM COMP 5 TH REF to 10kΩ TH terminal is pulled up to REF terminal. The Limit ON Duty is invalid. LOGIC 0Ω to SEL REF 14 13 Start Duty Assist SEL=OPEN: 53% SEL=10kΩ: 33% to 10kΩ 12 OSC OSC HALL COMP 0.1μF to H– 11 100pF 7 0Ω to SIG PS CONTROL 6 SIG 15 Internal REG 1μF to + OUT1 16 8 FG QUICK START AL SIGNAL OUTPUT HALL BIAS LOCK PROTECT TSD HB 10 H+ 0Ω to H 9 Figure 46. Application of DC Voltage Input 2 www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 15/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Application Circuit Example (Constant Values are for Reference) 4. DC Voltage Input Application 3 (Thermistor Control Application) This is an example application circuit for controlling the rotational speed by ambient temperature. In this application, if the thermistor is OPEN, the IC operates at the set minimum rotational speed. Output duty changes depending on the TH voltage. Function of limit ON duty at start up can be set using the SEL terminal. M - 1 Set MIN voltage less than OSC high (typ. 3.6V) 2 GND GND OUT2 HALL AMP HALL AMP 3 VCC The input voltage is changeable in the ambient temperature set by the thermistor constant. 15 Internal REG 1μF to + OUT1 16 4 STANDBY PWM COMP MIN PS FUNCTION SELECTOR SEL PWM COMP 5 TH REF REF 14 13 12 CONTROL Linearization correction resistance if necessary. LOGIC 6 OSC OSC 0.1μF to HALL COMP H– 11 100pF SIG Limit ON duty at start up SEL=OPEN: Disable SEL=10kΩ: Enable to 10kΩ 7 FG QUICK START AL SIGNAL OUTPUT 0Ω to 0Ω to SIG 8 HB 10 HALL BIAS LOCK PROTECT H+ TSD 0Ω to H 9 Figure 47. Application of Thermistor Control 5. Pulse Input Application (Use of stand-by function) This is an example application circuit for inverting the external PWM input, and controlling the rotational speed. In this application, if the external PWM input is OPEN, the IC operates at the set maximum rotational speed. Minimum rotational speed cannot be set. The output duty changes depending on MIN. Function of Start Duty Assist can be set using the SEL terminal. M GND GND 1 - PWM inversion circuit, Take into consideration the operating input voltage range of MIN terminal. 2 OUT2 HALL AMP HALL AMP 3 VCC Circuit that input direct PWM (Ref.) PWM input frequency is 2kHz to 50kHz. 4 MIN STANDBY PWM COMP FUNCTION SELECTOR PWM COMP PWM TH terminal is pulled up by REF terminal. The Limit ON Duty is invalid. 5 TH REF to 10kΩ 15 From PWM Terminal PS SEL REF 14 13 12 6 OSC OSC HALL COMP 0.1μF to H– 11 100pF SIG 7 FG QUICK START AL SIGNAL OUTPUT 0Ω to 0Ω to SIG Start Duty Assist SEL=OPEN: 53% SEL=10kΩ: 33% to 10kΩ CONTROL LOGIC To STBY(14Pin) 16 Internal REG 1μF to + OUT1 Input PWM signal into PS terminal, can use stand-by function. Only in the case of PUSH-PULL input signal. 8 HALL BIAS LOCK PROTECT TSD HB 10 H+ 0Ω to H 9 Figure 48. Application of Pulse Input www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 16/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Functional Descriptions 1. Variable Speed Operation The rotating speed changes by PWM duty on the motor outputs (OUT1, OUT2 terminals). PWM operation can be enabled by DC Voltage Input in TH Terminal, and MIN Terminal Pulse Input in MIN Terminal (1) PWM Operation by DC Input As shown in Figure 51, to change motor output ON duty, DC voltage input from TH terminal is compared with triangle wave produced by internal OSC circuit. MIN terminal is for setting the minimum rotating speed. ON duty is determined by either TH terminal voltage or MIN terminal, whichever is lower. OSC OSC REF PWM TH LPF PWM COMP REF MIN PWM COMP Figure 49. DC Input Application 1 OSC REF H– High H+ REF TH MIN OSC Low 5.0V 3.6V 1.5V 0.0V GND OSC High OUT1 Low TH PWM COMP REF Motor output ON High OUT2 Low MIN PWM COMP Full Motor Torque Min. Zero Figure 50. DC Input Application 2 Figure 51. DC Input Operation Timing Chart Dividing resistance of the internal regulator generates OSC high level (typ. 3.6V) and OSC low level (typ. 1.5V) voltage, and the ratio of those voltages is designed to be hard to fluctuate. When the input voltage at TH terminal is constant, effect by fluctuation of OSC H/L voltage is large. However, by setting that an application of REF voltage generates input voltage via TH, application can be made hard to be affected by voltage fluctuation of triangle wave. For an application that requires strict precision, determine a value with sufficient margin after taking full consideration of external constants. (2) PWM Operation by Pulse Input Pulse signal can be input to MIN terminal for PWM operation as shown in Figure 53. The ON duty of the output changes by the cycle of the input pulse signal. The TH terminal is pulled-up in the REF terminal. H– High H+ Low High PWM Low REF TH MIN OSC REF 5.0V 3.6V OSC OSC 1.5V 0.0V GND High TH PWM COMP REF REF Low Motor output ON High MIN PWM COMP PWM Figure 52. Pulse Input Application www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 OUT1 OUT2 Low Full Motor Torque Zero Figure 53. Pulse Input Operation Timing Chart 17/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Functional Descriptions 1. Variable Speed Operation – Continued (3) Setting of TH and MIN Terminals The voltage of the TH terminal or MIN terminal becomes irregular when it is open. Please apply voltages to both terminals when you turn on IC power supply (VCC). Setting less than OSC High level (Torque ONsetting) OK REF Pull up setting (Torque OFFsetting) OK TH MIN REF Pull down setting (Prohibit input) NG TH MIN REF Open setting (Prohibit input) NG TH MIN REF TH MIN Figure 54. Setting of the Variable Speed Function (4) Output Oscillatory Frequency Setting Frequency (Fosc) in which the motor outputs are operated PWM by DC voltage input is set according to capacity value (Cosc) of the capacitor connected with OSC terminal. fOSC = |IDOSC x ICOSC|/ (COSC x (|IDOSC| + |ICOSC|) x (VOSCH - VOSCL)) [Hz] (Equation 1) fOSC: OSC Frequency [Hz] COSC: OSC Capacitance [F] IDOSC: OSC Discharge current [A] (Typ 11μA) ICOSC: OSC Charge current [A] (Typ -11μA) VOSCH: OSC High voltage [V] (Typ 3.6V) VOSCL: OSC Low voltage [V] (Typ 1.5V) (ex.) The frequency when motor output PWM operates becomes about 26.2 kHz when assuming that Cosc is 100pF. fOSC=|11 x 10-6 x -11 x 10-6| / (100 x 10-12 x (|11 x 10-6| + |-11 x 10-6|) x (3.6-1.5)) = 26.2 x 103 [Hz] (Equation2) 2. Limit ON Duty at Start-up and Function Selector (1) Limit ON Duty at Start-up In the application circuit of speed control by DC voltage input, Limit ON Duty at start up function can reduce the rush current of the motor. It is driven by a constant output duty (DOHL; Typ 53%) within a given period of time (tOHL; Typ 0.5s). When SEL is LOW (pull-down to GND using R<10kΩ) and TH voltage is less than 3.6V (Typ), Limit ON Duty at start up function operates under the following conditions: (a) Power ON (b) Quick Start (c) Lock release, Lock detection ON time(TON) (d) Standby release DOH Motor Output ON Duty[%] 53 0 2.49 OFF tOHL (Typ 0.5s) DOHL (Typ 53%) 1.5 ON Power Supply 100 3.6 THVoltage [V] VTH Motor Output ON Duty Duty limit 0% Power ON Figure 55. Characteristic of Limit ON Duty at Start-up Input torque DOHL (Typ 53%) :Limit ON Duty at start-up Figure 56. Timing Chart of Power ON (2) Function Selector of Limit ON Duty Function of Limit ON duty at start up can be set (Disable or Enable) using the SEL terminal. Please refer to the timing chart (Figure 56, 61, 62) for each function. (a) SEL = OPEN (pull up to internal REG); Limit ON Duty at Start-up Disable (b) SEL = Low (pull down to GND using R<10kΩ); Limit ON Duty at Start-up Enable Internal REG OPEN SEL Disable DUTY LIMIT START-UP Internal REG CONTROL LOGIC Pull down To GND FUNCTION SELECTOR to 10kΩ SEL=OPEN Limit ON Duty at Start-up: Disable SEL Enable DUTY LIMIT START-UP CONTROL LOGIC FUNCTION SELECTOR SEL=pull down to GND Limit ON Duty at start-up: Enable Figure 57. Select Function in the DC Voltage Input Application www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 18/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Functional Descriptions 3. Start Duty Assist and Duty Selector (1) Start Duty Assist In the application circuit of speed control by pulse input, Start Duty Assist can secure a constant starting torque even at low duty. The IC is driven by a constant output duty (DOHS1; Typ 33% or DOHS2; Typ 53%) within a given period of time (Typ 0.25s). When TH voltage more than REF-0.1V and MIN voltage is less than 3.6V (Typ), Start Duty Assist function operates under the following conditions: (a) Power ON (b) Quick Start (c) Lock release, Lock detection ON time (Ton) (d) Standby release When the motor rotates, this function is released even if in this time. Motor output ON Duty[%] DOH 53 33 0 50 OFF Typ 0.25s DOHS (Typ 53% or 33%) 0 ON Power Supply 100 100 MIN ON Duty[%] DMIN Input torque Motor DOHS (Typ 53% or 33%) Output ON Duty Power ON Figure 58. Characteristic of Start Duty Assist Duty assist. 0% :Start Duty Assist Figure 59. Timing Chart of Power ON (2) Duty Selector of Start Duty Assist Function of Start Duty Assist can be set to either 53% or 33% using the SEL terminal. Please refer to the timing chart (Figure 59, 62, 63) for each function. (a) SEL = OPEN (pull up to internal REG); Duty 53% (b) SEL = Low (pull down to GND using R<10kΩ); Duty 33% Internal REG OPEN SEL Duty 53% START DUTY ASSIST Internal REG CONTROL LOGIC Pull down to GND FUNCTION SELECTOR to 10kΩ SEL=OPEN: Start Duty Assist 53% SEL Duty 33% START DUTY ASSIST CONTROL LOGIC FUNCTION SELECTOR SEL=pull down to GND: Start Duty Assist 33% Figure 60. Duty Select in the Pulse Input Application (3) Relation with Limit ON Duty Function As shown in Table1, the function changes depending on the setting of SEL terminal and the two speed control applications. Table 1. Speed Control Application and SEL Terminal Setting SEL Terminal Speed Control Application OPEN 10kΩ pull down to GND DC Voltage Input (TH<REF-0.5V) Pulse Input (TH>REF-0.1V) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 Limit ON Duty : Disable Start Duty Assist : 53% 19/31 Limit ON Duty : Enable Start Duty Assist : 33% TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Functional Descriptions 4. Quick Start When torque off logic is input by the control signal over a fixed time (1.0ms), the lock protection function is disabled. The motor can restart quickly once the control signal is applied. Lock alarm signal (AL) at the time of the Quick Start maintains the logic of the AL signal just before the Quick Start standby. But when AL signal begins Quick Start standby in Hi-Z and a hall input signal is replaced during Quick Start standby later, AL signal is changed to L from H. The lock protection function doesn’t work with an input frequency slower than 1 kHz assuming high level duty = 100% of the MIN input signal. Input signal frequency must be faster than 2 kHz. Motor idling H– High H+ Low TH 3.6V Lock Protection Signal Enable Disable Typ 1.0ms Quick start standby mode Motor Output ON Duty Input torque (SEL=OPEN or TH>2.49V) 0% tOHL (Typ 0.5s) Motor Output ON Duty Input torque Duty limit DOHL (Typ 53%) (SEL<0.8V and TH<2.49V) 0% Torque OFF Motor stop Torque ON :Limit ON Duty enable Figure 61. Quick Start Timing Chart (DC Input Application) Motor Idling H– High H+ Low High MIN Low Lock Protection Signal Enable Disable Typ 1.0ms Typ 0.25s Quick start standby mode DOHS2 (Typ 53%) Motor Output ON Duty Input torque Duty assist. (SEL=OPEN) 0% Typ 0.25s Motor Output ON Duty Input torque DOHS1 (Typ 33%) Duty assist. 0% (SEL<0.8V) Torque OFF Motor stop Torque ON :Start Duty Assist Figure 62. Quick Start Timing Chart (Pulse Input Application) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 20/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Functional Descriptions 5. Lock Protection and Automatic Restart Motor rotation is detected by hall signal and the IC internal counter set lock detection ON time (TON) and OFF time (TOFF). Timing chart is shown in Figure 63. Motor Idling H– High H+ Low tON (Typ 0.5s) tOFF (Typ 5.0s) tOFF tON tOFF tON High OUT1 Low High OUT2 Low High FG Low High AL Low Input torque Motor Output ON Duty (SEL=OPEN or TH>2.49V) 0% tOHL (Typ 0.5s) Motor Output ON Duty (SEL<0.8V and TH<2.49V) Typ 0.25s Motor Output ON Duty (TH=REF and MIN<3.6V) Motor lock Lock detection Lock release : High impedance Input torque Duty limit 0% Input torque Duty assist. 0% :Limit ON Duty :Start Duty Assist 53% or 33% Figure 63. Lock Protection (Incorporated Counter System) Timing Chart でゅーて 6. Hall Input Setting (1) Hall Input Setting Hall input voltage range is shown in operating conditions (P.1). Adjust the value of hall element bias resistor R 1 in Figure 65 so that the input voltage of a hall amplifier is input in "hall input voltage range" including signal amplitude. IH Hall input upper limit H– 3V (Vcc>9V) Vcc/3V (Vcc<9V) HALL BIAS HB C1 Hall bias current; IH[A] = Vhb[V] / (RH+R1)[Ω] Hall H– H+ Operating hall input voltage range HALL AMP H– RH H+ H+ Hall input lower limit HALL COMP 0.4V Figure 64. Hall Input Voltage Range C2 R1 Figure 65. Hall Input Application (2) Reducing the Noise of Hall Signal VCC noise or the like depending on the wiring pattern of board may affect Hall element. In this case, place a capacitor like C1 in Figure 65. In addition, when wiring from the hall element output to IC hall input is long, noise may be loaded on wiring. In this case, place a capacitor like C2. www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 21/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Functional Descriptions 7. BTL Soft Switching Function (Silent Drive Setting) (1) Motor Output Slope by the Hall Input Amplitude Input signal to hall amplifier (H+, H–) is amplified to produce an output signal (OUT1, OUT2). When the hall element amplitude is small, the slope of the output waveform is gentle. When it is large, the slope of the output waveform is steep. Gain of 48.5dB (270 times) is provided between input and output, therefore, an appropriate hall element input signal must be applied to the IC such that output waveform swings. An input of more than 150mVpp (Hall amplitude difference conversion) is recommended. Hall amplitude; Large Hall amplitude; Middle Hall amplitude; Small Large H– Mid. Small Small Mid. H+ Large High OUT1 Low High OUT2 Low Motor Current 0A Figure 66. Hall Input Amplitude and the Motor Output Waveform (2) Drive System at DC Voltage Input At the speed controlled by the DC voltage input to TH terminal, BD6994FV automatically adjusts the regeneration section during phase change of output depending on TH voltage. As a result, the motor becomes closer to H bridge drive at high speed rotation, and contributes to lower power consumption Rotate at high speed (0.2V < TH < 1.5V) Rotate at middle speed (1.5V < TH < 2.0V) Rotate at low speed (2.0V < TH < 3.6V) H– H+ High OUT1 Low High OUT2 Low Motor Current 0A Figure 67. TH Voltage and Motor Output Waveform (PWM by the TH voltage is Omitted for a Functional Description) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 22/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Functional Descriptions 8. Stand-by When L logic of PS pin is input by the control signal over a fixed time (1.0ms), the IC will be in stand-by mode. In stand-by mode, AL signal becomes L logic and FG signal becomes Hi-Z logic. When H logic of PS pin is input by the control signal, the IC is in normal drive mode. When AL pin is not used in stand-by mode, the motor current becomes 160uA (VCC=12V,Typ). Motor idling 空転 H– High H+ Low High PS Low REF/HB Typ 1.0ms OFF Stand-by High OUT1 Low High OUT2 Low High FG Low Torque OFF Motor Stop Torque ON Figure 68.Stand-by Timing Chart When PS pin is used like in the application circuit example, use PUSH-PULL PWM signal input. PWM signal input of the open Drain / Collector cannot be used. Because internal resistance (200kΩ: pull up to internal REG) is high, using open Drain / Corrector is not enough for speed of H input. www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 23/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Safety Measure 1. Reverse Connection Protection Diode Reverse connection of power results in IC destruction as shown in Figure 69. When reverse connection is possible, reverse connection protection diode must be added between power supply and VCC. After reverse connection In normal energization Reverse power connection VCC destruction prevention VCC I/O Circuit VCC I/O Circuit Block Circuit Block GND GND Internal circuit impedance is high Amperage small I/O Block GND Large current flows Thermal destruction No destruction Figure 69. Flow of Current When Power is Connected Reversely 2. Measure against VCC Voltage Rise by Back Electromotive Force Back electromotive force (Back EMF) generates regenerative current to power supply. However, when reverse connection protection diode is connected, VCC voltage rises because the diode prevents current flow to power supply. ON Phase Switching ON ON ON Figure 70. VCC Voltage Rise by Back Electromotive Force When the absolute maximum rated voltage may be exceeded due to voltage rise by back electromotive force, place (A) Capacitor or (B) Zener diode between VCC and GND. If necessary, add both (C). (A) Capacitor (B) Zenner diode ON (C) Capacitor & Zenner diode ON ON ON ON ON Figure 71. Measure against Vcc and Motor Driving Outputs Voltage Rise at Regenerative Braking 3. Problem of GND line PWM Switching Do not perform PWM switching of GND line because GND terminal potential cannot be kept to a minimum. 4. Protection of Rotation Speed Pulse (FG) and/or Lock Alarm (AL) Open-Drain Output FG and/or AL output is an open drain and requires pull-up resistor. Adding resistor can protect the IC. Exceeding the absolute maximum rating, when FG and/or AL terminal is directly connected to power supply, could damage the IC. Motor Unit VCC Controller Motor Driver Driver M AL FG Protection Resistor Pull-up Resistor SIG Connector GND PWM Input Prohibit Figure 72. GND Line PWM Switching Prohibited www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 24/31 Figure 73. Protection of FG/AL Terminal TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV M Power Consumption 1. Current Pathway - The current pathways that relates to driver IC are the following, and shown in Figure 74. (1) Circuit Current (ICC) + (2) Motor Driving Current (IM) (3) Reference Bias Current to the LPF and Resistors (IREF) (4) Hall Bias Current to the Hall Element (IHB) (5) FG(AL) Output Sink Current (ISO) 1 2 GND GND OUT2 HALL AMP HALL AMP IM 3 VCC STANDBY ICC 4 PWM COMP MIN PW(a): Power consumption [W] VCC: VCC voltage [V] ICC: Circuit current [A] (Expect hall bias current (IHB)) FUNCTION SELECTOR PWM COMP 5 TH REF PS SEL REF 14 13 12 IREF CONTROL LOGIC 6 SIG 15 Internal REG PWM 2. Calculation of Power Consumption (1) Circuit Current (Icc) PW(a) = VCC x ICC [W] (Equation3) OUT1 16 ISO 7 SIG 8 OSC HALL COMP OSC H– 11 IHB FG QUICK START AL SIGNAL OUTPUT HALL BIAS LOCK PROTECT TSD HB 10 H+ H 9 Figure 74. Current Pathway of IC (2) Motor Driving Current (IM) PW(b) = ((VOH+VOL) x IM) x T2/T1 + (ICHANGE / 2 x VCC / 4) x T3/ T1 [W] (Equation4) PW(b): Power consumption [W] VOH: Output high voltage [V] VOL: Output low voltage [V] IM: Motor driving average current [A] ICHANGE: Motor driving current of BTL initiation [A] (3) Reference Bias Current to the LPF and Resistors (IREF) PW(c) = (VCC - VREF) x IREF [W] (Equation5) PW(c): Power consumption [W] VREF: REF voltage [V] IREF: REF bias current [A] H– H+ OUT1 OUT2 I Change Im T2 (4) Hall Bias Current to the Hall Element (IHB) PW(d) = (VCC - VHB) x IHB [W] (Equation6) T3 T1 Figure 75. Motor Driving Current for calculation PW(d): Power consumption [W] VHB: Hall bias voltage [V] IHB: Hall bias current [A] (5) FG(AL) Output Sink Current (Iso) PW(e) = VSO x ISO [W] (Equation7) PW(e): Power consumption [W] VSO: FG(AL) output low voltage [V] ISO: FG(AL) output sink current [A] Total power consumption of driver IC becomes the following by the above (1) to (5). PW(ttl) = PW(a) + PW(b) + PW(c) + PW(d) + PW(e) [W] (Equation8) (ex.) PW(a) = 12 x 6.5 x 10-3 [W] (Equation9) PW(b) = ((0.37 + 0.23) x 0.4) x 9/10 + (0.4/2 x 12/4) x 1/10 [W] (Equation10) PW(c) = (12 - 5.1) x 2.0 x10-3 [W] (Equation11) PW(d) = (12 - 1.25) x 3.5 x 10-3 [W] (Equation12) PW(e) = 0.2 x 5.0 x 10-3 [W] (Equation13) PW(ttl) = 0.406 [W] (Equation14) Refer to next page when you calculate the chip surface temperature (Tj) and the package surface temperature (Tc) by using the power consumption value. www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 25/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Power Dissipation 1. Power Dissipation Power dissipation (total loss) indicates the power that can be consumed by IC at Ta=25°C (normal temperature). IC is heated when it consumes power, and the temperature of IC chip becomes higher than ambient temperature. The temperature that can be accepted by IC chip into the package, that is junction temperature of the absolute maximum rating, depends on circuit configuration, manufacturing process, etc. Power dissipation is determined by this maximum joint temperature, the thermal resistance in the state of the substrate mounting, and the ambient temperature. Therefore, when a power dissipation exceeds the absolute maximum rating, the operating temperature range is not a guarantee. The maximum junction temperature is in general equal to the maximum value in the storage temperature range. 2. Thermal Resistance Heat generated by consumed power of IC is radiated from the mold resin or lead frame of package. The parameter which indicates this heat dissipation capability (hardness of heat release) is called thermal resistance. In the state of the substrate mounting, thermal resistances from the chip junction to the ambience and to the package surface are shown respectively with θja[°C/W] and θjc[°C/W]. Thermal resistance is classified into the package part and the substrate part, and thermal resistance in the package part depends on the composition materials such as the mold resins and the lead frames. On the other hand, thermal resistance in the substrate part depends on the substrate heat dissipation capability of the material, the size, and the copper foil area etc. Therefore, thermal resistance can be decreased by the heat radiation measures like installing a heat sink etc. in the mounting substrate. The thermal resistance model and calculations are shown in Figure 76, and Equation 15 and 16, respectively. θja = (Tj - Ta) / P [°C/W] (Equation 15) θjc = (Tj - Tc) / P [°C/W] (Equation 16) Ambient temperature: Ta[°C] Package surface Temperature: Tc[°C] θja[°C/W] where: θja is the thermal resistance from the chip junction to the ambience θjc is the thermal resistance from the chip junction to the package surface Tj is the junction temperature Ta is the ambient temperature Tc is the package surface temperature P is the power consumption Chip surface temperature: Tj[°C] θjc[°C/W] Mouting Substrate Figure 76. Thermal Resistance Model of Surface Mount Even if it uses the same package, thermal resistance θja and θjc are changed depending on the chip size, power consumption, and the measurement environments of the ambient temperature, the mounting condition, and the wind velocity, etc. Thermal resistance under a certain regulated condition is shown in Table 2 as a reference data when the FR4 glass epoxy substrate (70mm x 70mm x 1.6mm and 3% or less in the area of the copper foil) is mounted. Table 2. Thermal Resistance (Reference Data) Rohm Standard (Note 1) θja θjc Unit °C/W °C/W Mounted on 70.0mm x 70.0mm x 1.6mm glass epoxy board 3. Thermal De-rating Curve Thermal de-rating curve indicates power that can be consumed by IC with reference to ambient temperature. Power that can be consumed by IC begins to attenuate at certain ambient temperature (25°C), and becomes 0W at the maximum joint temperature (150°C). The inclination is reduced by the reciprocal of thermal resistance θja. The thermal de-rating curve under a certain regulated condition is shown in Figure 77. 1.0 Power Dissipation: Pd[W] (Note 1) One-layer 142.9 36 0.8 -1/θja=-7.0mW/°C 0.6 0.4 Operating temp range 0.2 0.0 -50 -25 0 25 50 75 100 125 150 Ambient Temperature: Ta[°C] Figure 77. Power Dissipation vs Ambient Temperature (Mounted on 70.0mm x 70.0mm x 1.6mm glass epoxy substrate) www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 26/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV I/O Equivalence Circuit (Resistance Values are Typical) 1. Power supply terminal, and Ground terminal 2. Hall input terminals, 3. Motor output pins Output duty controllable input pin, and Minimum output duty setting pin 4. Reference voltage output and Hall bias pin Vcc Vcc Vcc H+ H– TH MIN GND REF HB OUT1 OUT2 1kΩ 5. Duty control start up function setting pin Internal REG 6. Oscillating capacitor connecting pin Internal REG 7. Speed pulse signal output pin and Lock alarm signal output pin Internal REG Vcc 10kΩ Internal REG 200kΩ 150kΩ SEL 8. Power Save pin 1kΩ 5Ω 1kΩ FG AL PS 10kΩ OSC www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 27/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Operational Notes 1. Reverse Connection of Power Supply Connecting the power supply in reverse polarity can damage the IC. Take precautions against reverse polarity when connecting the power supply, such as mounting an external diode between the power supply and the IC’s power supply pins. 2. Power Supply Lines Design the PCB layout pattern to provide low impedance supply lines. Separate the ground and supply lines of the digital and analog blocks to prevent noise in the ground and supply lines of the digital block from affecting the analog block furthermore, connect a capacitor to ground at all power supply pins. Consider the effect of temperature and aging on the capacitance value when using electrolytic capacitors. 3. Ground Voltage Ensure that no pins are at a voltage below that of the ground pin at any time, even during transient condition. However, pins that drive inductive loads (e.g. motor driver outputs, DC-DC converter outputs) may inevitably go below ground due to back EMF or electromotive force. In such cases, the user should make sure that such voltages going below ground will not cause the IC and the system to malfunction by examining carefully all relevant factors and conditions such as motor characteristics, supply voltage, operating frequency and PCB wiring to name a few. 4. Ground Wiring Pattern When using both small-signal and large-current ground traces, the two ground traces should be routed separately but connected to a single ground at the reference point of the application board to avoid fluctuations in the small-signal ground caused by large currents. Also ensure that the ground traces of external components do not cause variations on the ground voltage the ground lines must be as short and thick as possible to reduce line impedance. 5. Thermal Consideration Should by any chance the power dissipation rating be exceeded the rise in temperature of the chip may result in deterioration of the properties of the chip. The absolute maximum rating of the power dissipation stated in this datasheet is when the IC is mounted on a 70mm x 70mm x 1.6mm glass epoxy board. In case of exceeding this absolute maximum rating, increase the board size and copper area to raise heat dissipation capability. 6. Recommended Operating Conditions These conditions represent a range within which the expected characteristics of the IC can be approximately obtained. The electrical characteristics are guaranteed under the conditions of each parameter. 7. Inrush Current When power is first supplied to the IC, it is possible that the internal logic may be unstable and inrush current may flow instantaneously due to the internal powering sequence and delays, especially if the IC has more than one power supply. Therefore, give special consideration to power coupling capacitance, width of power and ground wiring, and routing of connections. 8. Operation Under Strong Electromagnetic Field Operating the IC in the presence of a strong electromagnetic field may cause the IC to malfunction. 9. Testing on Application Boards When testing the IC on an application board, connecting a capacitor directly to a low-impedance output pin may subject the IC to stress. Always discharge capacitors completely after each process or step. To prevent damage from static discharge, ground the IC during assembly and use similar precautions during transport and storage. The IC’s power supply should always be turned off completely before connecting or removing it from the test setup during the inspection process. 10. Mounting Errors and Inter-pin Short Ensure that the direction and position are correct when mounting the IC on the PCB. Incorrect mounting may result in damaging the IC. Avoid nearby pins being shorted to each other especially to ground, power supply and output pin. Inter-pin shorts could be due to many reasons such as metal particles, water droplets (in very humid environment) and unintentional solder bridge deposited in between pins during assembly to name a few. www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 28/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Operational Notes 11. Unused Input Pins Input pins of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. Especially, if it is not expressed on the datasheet, unused input pins should be connected to the power supply or ground line. 12. Regarding the Input Pin of the IC This monolithic IC contains P+ isolation and P substrate layers between adjacent elements in order to keep them isolated. P-N junctions are formed at the intersection of the P layers with the N layers of other elements, creating a parasitic diode or transistor. For example (refer to figure below): When GND > Pin A and GND > Pin B, the P-N junction operates as a parasitic diode. When GND > Pin B, the P-N junction operates as a parasitic transistor. Parasitic diodes inevitably occur in the structure of the IC. The operation of parasitic diodes can result in mutual interference among circuits, operational faults, or physical damage. Therefore, conditions that cause these diodes to operate, such as applying a voltage lower than the GND voltage to an input pin (and thus to the P substrate) should be avoided. Resistor Transistor (NPN) Pin A Pin B C E Pin A N P+ P N N P+ N Parasitic Elements N P+ N P N P+ B N C E Parasitic Elements P Substrate P Substrate Parasitic Elements Pin B B GND Parasitic Elements GND GND N Region close-by GND Figure 78. Example of Monolithic IC Structure 13. Ceramic Capacitor When using a ceramic capacitor, determine the dielectric constant considering the change of capacitance with temperature and the decrease in nominal capacitance due to DC bias and others. 14. Area of Safe Operation (ASO) Operate the IC such that the output voltage, output current, and power dissipation are all within the Area of Safe Operation (ASO). 15. Thermal Shutdown (TSD) Circuit This IC has a built-in thermal shutdown circuit that prevents heat damage to the IC. Normal operation should always be within the IC’s power dissipation rating. If however the rating is exceeded for a continued period, the junction temperature will rise which will activate the TSD circuit that will turn OFF all output pins. When the junction temperature falls below the TSD threshold, the circuits are automatically restored to normal operation. Note that the TSD circuit operates in a situation that exceeds the absolute maximum ratings and therefore, under no circumstances, should the TSD circuit be used in a set design or for any purpose other than protecting the IC from heat damage. www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 29/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Physical Dimension, Tape and Reel Information Package Name www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 SSOP-B16 30/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 BD6994FV Ordering Information B D 6 9 9 Part Number 4 F V Package ・FV; SSOP-B16 GE 2 - Packaging and forming specification ・G;Halogen free ・E2;Embossed tape and reel Marking Diagram SSOP-B16 (TOP VIEW) D 6 9 9 4 Part Number LOT Number 1PIN Mark Revision History Date Revision 18.May.2015 13.Jul.2015 001 002 Comments New Release Change of Ordering Information www.rohm.com © 2015 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 31/31 TSZ02201-0H1H0B101220-1-2 13.Jul.2015 Rev.002 Datasheet Notice Precaution on using ROHM Products 1. Our Products are designed and manufactured for application in ordinary electronic equipments (such as AV equipment, OA equipment, telecommunication equipment, home electronic appliances, amusement equipment, etc.). If you (Note 1) , transport intend to use our Products in devices requiring extremely high reliability (such as medical equipment equipment, traffic equipment, aircraft/spacecraft, nuclear power controllers, fuel controllers, car equipment including car accessories, safety devices, etc.) and whose malfunction or failure may cause loss of human life, bodily injury or serious damage to property (“Specific Applications”), please consult with the ROHM sales representative in advance. Unless otherwise agreed in writing by ROHM in advance, ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of any ROHM’s Products for Specific Applications. (Note1) Medical Equipment Classification of the Specific Applications JAPAN USA EU CHINA CLASSⅢ CLASSⅡb CLASSⅢ CLASSⅢ CLASSⅣ CLASSⅢ 2. ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which a failure or malfunction of our Products may cause. The following are examples of safety measures: [a] Installation of protection circuits or other protective devices to improve system safety [b] Installation of redundant circuits to reduce the impact of single or multiple circuit failure 3. Our Products are designed and manufactured for use under standard conditions and not under any special or extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the use of any ROHM’s Products under any special or extraordinary environments or conditions. If you intend to use our Products under any special or extraordinary environments or conditions (as exemplified below), your independent verification and confirmation of product performance, reliability, etc, prior to use, must be necessary: [a] Use of our Products in any types of liquid, including water, oils, chemicals, and organic solvents [b] Use of our Products outdoors or in places where the Products are exposed to direct sunlight or dust [c] Use of our Products in places where the Products are exposed to sea wind or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2 [d] Use of our Products in places where the Products are exposed to static electricity or electromagnetic waves [e] Use of our Products in proximity to heat-producing components, plastic cords, or other flammable items [f] Sealing or coating our Products with resin or other coating materials [g] Use of our Products without cleaning residue of flux (even if you use no-clean type fluxes, cleaning residue of flux is recommended); or Washing our Products by using water or water-soluble cleaning agents for cleaning residue after soldering [h] Use of the Products in places subject to dew condensation 4. The Products are not subject to radiation-proof design. 5. Please verify and confirm characteristics of the final or mounted products in using the Products. 6. In particular, if a transient load (a large amount of load applied in a short period of time, such as pulse. is applied, confirmation of performance characteristics after on-board mounting is strongly recommended. Avoid applying power exceeding normal rated power; exceeding the power rating under steady-state loading condition may negatively affect product performance and reliability. 7. De-rate Power Dissipation (Pd) depending on Ambient temperature (Ta). When used in sealed area, confirm the actual ambient temperature. 8. Confirm that operation temperature is within the specified range described in the product specification. 9. ROHM shall not be in any way responsible or liable for failure induced under deviant condition from what is defined in this document. Precaution for Mounting / Circuit board design 1. When a highly active halogenous (chlorine, bromine, etc.) flux is used, the residue of flux may negatively affect product performance and reliability. 2. In principle, the reflow soldering method must be used on a surface-mount products, the flow soldering method must be used on a through hole mount products. If the flow soldering method is preferred on a surface-mount products, please consult with the ROHM representative in advance. For details, please refer to ROHM Mounting specification Notice-PGA-E © 2015 ROHM Co., Ltd. All rights reserved. Rev.001 Datasheet Precautions Regarding Application Examples and External Circuits 1. If change is made to the constant of an external circuit, please allow a sufficient margin considering variations of the characteristics of the Products and external components, including transient characteristics, as well as static characteristics. 2. You agree that application notes, reference designs, and associated data and information contained in this document are presented only as guidance for Products use. Therefore, in case you use such information, you are solely responsible for it and you must exercise your own independent verification and judgment in the use of such information contained in this document. ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of such information. Precaution for Electrostatic This Product is electrostatic sensitive product, which may be damaged due to electrostatic discharge. Please take proper caution in your manufacturing process and storage so that voltage exceeding the Products maximum rating will not be applied to Products. Please take special care under dry condition (e.g. Grounding of human body / equipment / solder iron, isolation from charged objects, setting of Ionizer, friction prevention and temperature / humidity control). Precaution for Storage / Transportation 1. Product performance and soldered connections may deteriorate if the Products are stored in the places where: [a] the Products are exposed to sea winds or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2 [b] the temperature or humidity exceeds those recommended by ROHM [c] the Products are exposed to direct sunshine or condensation [d] the Products are exposed to high Electrostatic 2. Even under ROHM recommended storage condition, solderability of products out of recommended storage time period may be degraded. It is strongly recommended to confirm solderability before using Products of which storage time is exceeding the recommended storage time period. 3. Store / transport cartons in the correct direction, which is indicated on a carton with a symbol. Otherwise bent leads may occur due to excessive stress applied when dropping of a carton. 4. Use Products within the specified time after opening a humidity barrier bag. Baking is required before using Products of which storage time is exceeding the recommended storage time period. Precaution for Product Label QR code printed on ROHM Products label is for ROHM’s internal use only. Precaution for Disposition When disposing Products please dispose them properly using an authorized industry waste company. Precaution for Foreign Exchange and Foreign Trade act Since concerned goods might be fallen under listed items of export control prescribed by Foreign exchange and Foreign trade act, please consult with ROHM in case of export. Precaution Regarding Intellectual Property Rights 1. All information and data including but not limited to application example contained in this document is for reference only. ROHM does not warrant that foregoing information or data will not infringe any intellectual property rights or any other rights of any third party regarding such information or data. 2. ROHM shall not have any obligations where the claims, actions or demands arising from the combination of the Products with other articles such as components, circuits, systems or external equipment (including software). 3. No license, expressly or implied, is granted hereby under any intellectual property rights or other rights of ROHM or any third parties with respect to the Products or the information contained in this document. Provided, however, that ROHM will not assert its intellectual property rights or other rights against you or your customers to the extent necessary to manufacture or sell products containing the Products, subject to the terms and conditions herein. Other Precaution 1. This document may not be reprinted or reproduced, in whole or in part, without prior written consent of ROHM. 2. The Products may not be disassembled, converted, modified, reproduced or otherwise changed without prior written consent of ROHM. 3. In no event shall you use in any way whatsoever the Products and the related technical information contained in the Products or this document for any military purposes, including but not limited to, the development of mass-destruction weapons. 4. The proper names of companies or products described in this document are trademarks or registered trademarks of ROHM, its affiliated companies or third parties. Notice-PGA-E © 2015 ROHM Co., Ltd. All rights reserved. Rev.001 Datasheet General Precaution 1. Before you use our Pro ducts, you are requested to care fully read this document and fully understand its contents. ROHM shall n ot be in an y way responsible or liabl e for fa ilure, malfunction or acci dent arising from the use of a ny ROHM’s Products against warning, caution or note contained in this document. 2. All information contained in this docume nt is current as of the issuing date and subj ect to change without any prior notice. Before purchasing or using ROHM’s Products, please confirm the la test information with a ROHM sale s representative. 3. The information contained in this doc ument is provi ded on an “as is” basis and ROHM does not warrant that all information contained in this document is accurate an d/or error-free. ROHM shall not be in an y way responsible or liable for an y damages, expenses or losses incurred b y you or third parties resulting from inaccur acy or errors of or concerning such information. Notice – WE © 2015 ROHM Co., Ltd. All rights reserved. Rev.001 Datasheet BD6994FV - Web Page Buy Distribution Inventory Part Number Package Unit Quantity Minimum Package Quantity Packing Type Constitution Materials List RoHS BD6994FV SSOP-B16 2500 2500 Taping inquiry Yes