Micro EM Clutch/Brake Unit MP Types: 5, 10, 20, 40, 80 [ EM: Electromagnet ] MP Static Torque [in-lbs / N-m] Voltage [DC-V] Coil Current [A] Resistance [Ω] (20°C) Wattage [W] Max Work Rate [W] Max Allowable Speed [rpm] Max Overhanging Load¹ [lbs / N] Input Moment of Inertia (J) Output [kg cm²] [kg-cm²] Max Wear Volume [cm3] Max Work Rate [W] Bore [mm] dh7 bh8 Key Way [mm] t+0/-0.15 A B C D E F G H Dimensions I [mm] J K L M N O P Q R Weight [lbs / kg] 5 4.4 / 0.5 0.75 10 8.9 / 1 1.05 0.15 3.8 3.8 2000 21 / 92 0.068 0 125 0.125 0.57 3.8 6 2 6.9 61.5 42 32 30.5 64 5 35.5 72 62 M5 5.5 100 50 40 30 9 16 14 1.2 / 0.5 0.21 5.3 4.8 2000 43 / 190 0.148 02 0.2 0.75 4.8 8 2.5 8.9 69 48 35 35 74 5 40 84 70 M6 6.5 124 62 45 39.5 11 20 18 2 / 0.9 20 18 / 2 1.4 5* 0.28 7 5.7 2000 56 / 250 0.29 0 45 0.45 1.2 5.7 10 4 11.5 77 55 40 40 84 5 45 90 78 M6 6.5 139 69 50 44.5 12 23 20 3.3 / 1.5 40 35 / 4 1.65 80 71 / 8 2.4 0.33 8.3 8.2 1500 76 / 340 0.718 08 0.8 2.2 8.2 12 4 13.5 93 64 50 48 94 8 56 106 90 M8 8.5 166 80 60 53 13 30 20 4.6 / 2.1 0.48 12 14 1500 81 / 360 1.3 2 3.7 14 15 5 17 105 75 60 55 104 8 63 120 100 M8 8.5 194 86 70 62 14 40 35 6.4 / 2.9 [ Note 1 : At shaft midpoint; based on 600rpm/6000hr application ] [ 1" = 25.4mm ] * Coil voltage varies per unit size. A special power supply is required because of the special low voltage coils that are used to achieve over-excitation in these units. Ogura Industrial Corp. 100 Randolph Rd. Somerset NJ 08875 Somerset, www.ogura-clutch.com [email protected] (732) 271-7361 271 7361