Lumileds L150-4070500600000 High efficacy and lumens in a multi-die, high power package, enabling low system cost Datasheet

Illumination
LUXEON 5050
High efficacy and lumens in a multi-die, high
power package, enabling low system costs
LUXEON 5050 is a multi-die, high power package that provides high
luminance from a single package to enable cost effective, single optic and
directional fixture designs. LUXEON 5050 uses an industry standard 5050
surface mount package with the smallest round Light Emitting Surface
(LES). LUXEON 5050 comes in 70CRI, 80CRI and 90CRI with a wide range
of CCTs, and offers hot-color targeting to ensure that the LEDs are within
color target at application conditions of 85°C.
Features and Benefits
Primary Applications
Small LES (4.6mm) enables good optic design for great punch
Downlights
Enables highest efficacy system design by driving at low current
High Bay & Low Bay
Hot-color targeting ensures color is within ANSI bin at 85°C
Lamps
Binned within 3-step and 5-step MacAdam ellipse, ensuring color uniformity
Outdoor
Compatible with low cost and high efficacy drivers
Spotlights
DS174 LUXEON 5050 Product Datasheet ©2018 Lumileds Holding B.V. All rights reserved.
No. E352519
Table of Contents
General Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Lumen Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Performance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Optical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Electrical and Thermal Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Characteristic Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Spectral Power Distribution Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Light Output Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Forward Current Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Radiation Pattern Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Product Bin and Labeling Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Decoding Product Bin Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Luminous Flux Bins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Color Bin Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Forward Voltage Bins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mechanical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Reflow Soldering Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
JEDEC Moisture Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Solder Pad Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Packaging Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Pocket Tape Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Reel Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
i
General Product Information
Product Test Conditions
LUXEON 5050 LEDs are tested with a 20ms monopulse of 160mA for LUXEON 5050 24V and 640mA for LUXEON 5050 6V at a
junction temperature, Tj, of 25°C. Forward voltage and luminous flux are binned at a Tj of 25°C, while color is hot targeted at a
Tj of 85°C.
Part Number Nomenclature
Part numbers for LUXEON 5050 follow the convention below:
L 1 5 0 – A A B B 5 0 C C 0 0 0 0 0
Where:
A A –
designates nominal ANSI CCT (27=2700K, 30=3000K, 35=3500K 40=4000K, 50=5000K, 57=5700K, 65=6500K)
B B –
designates minimum CRI (70=70CRI, 80=80CRI, 90=90CRI)
C C –
designates voltage (06=6V, 24=24V)
Therefore, the following part number is used for a LUXEON 5050, 3000K 80CRI, 24V:
L 1 5 0 – 3 0 8 0 5 0 2 4 0 0 0 0 0
Lumen Maintenance
Please contact your local Sales Representative or Lumileds Technical Solutions Manager for more information about the longterm performance of this product.
Environmental Compliance
Lumileds LLC is committed to providing environmentally friendly products to the solid-state lighting market. LUXEON 5050 is
compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the
RoHS Directive 2011/65/EU and REACH Regulation (EC) 1907/2006. Lumileds LLC will not intentionally add the following restricted
materials to its products: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated
diphenyl ethers (PBDE).
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
2
Performance Characteristics
Product Selection Guide
Table 1. Product performance of LUXEON 5050 at test current, Tj=25°C.
VOLTAGE
24V
6V
Nominal
CCT [1]
Minimum
CRI [2, 3]
2700K
3000K
Luminous Flux [2, 3] (lm)
Typical Luminous
Efficacy (lm/W)
TEST
CURRENT
(mA)
Part Number
Minimum
Typical
70
535
600
153
160
L150-2770502400000
70
553
620
158
160
L150-3070502400000
4000K
70
580
650
166
160
L150-4070502400000
5000K
70
580
650
166
160
L150-5070502400000
5700K
70
570
650
166
160
L150-5770502400000
6500K
70
570
650
166
160
L150-6570502400000
2700K
80
500
560
143
160
L150-2780502400000
3000K
80
516
585
149
160
L150-3080502400000
3500K
80
527
595
152
160
L150-3580502400000
4000K
80
539
610
156
160
L150-4080502400000
5000K
80
539
610
156
160
L150-5080502400000
5700K
80
539
610
156
160
L150-5780502400000
6500K
80
539
610
156
160
L150-6580502400000
2700K
90
414
471
120
160
L150-2790502400000
3000K
90
428
486
124
160
L150-3090502400000
3500K
90
445
506
129
160
L150-3590502400000
4000K
90
456
526
134
160
L150-4090502400000
5000K
90
456
526
134
160
L150-5090502400000
5700K
90
456
526
134
160
L150-5790502400000
2700K
70
535
600
153
640
L150-2770500600000
3000K
70
553
620
158
640
L150-3070500600000
4000K
70
580
650
166
640
L150-4070500600000
5000K
70
580
650
166
640
L150-5070500600000
5700K
70
570
650
166
640
L150-5770500600000
6500K
70
570
650
166
640
L150-6570500600000
2700K
80
500
560
143
640
L150-2780500600000
3000K
80
516
585
149
640
L150-3080500600000
3500K
80
527
595
152
640
L150-3580500600000
4000K
80
539
610
156
640
L150-4080500600000
5000K
80
539
610
156
640
L150-5080500600000
5700K
80
539
610
156
640
L150-5780500600000
6500K
80
539
610
156
640
L150-6580500600000
2700K
90
414
471
120
640
L150-2790500600000
3000K
90
428
486
124
640
L150-3090500600000
3500K
90
445
506
129
640
L150-3590500600000
4000K
90
456
526
134
640
L150-4090500600000
5000K
90
456
526
134
640
L150-5090500600000
5700K
90
456
526
134
640
L150-5790500600000
Notes for Table 1:
1. Correlated color temperature is hot targeted at Tj=85°C.
2. Luminous flux and CRI are based upon mounted package on highly reflective surface at Tj=25°C. Typical CRI is approximately 2 points higher than the minimum CRI specified, but this
is not guaranteed.
3. Lumileds maintains a tolerance of ±2 on CRI and ±7% on luminous flux measurements.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
3
Optical Characteristics
Table 2. Optical characteristics for LUXEON 5050 at test current, Tj=25°C.
Part Number
Typical Total Included Angle [1]
Typical Viewing Angle [2]
L150-xxxx50xx00000
138°
116°
Notes for Table 2:
1. Total angle at which 90% of total luminous flux is captured.
2. Viewing angle is the off axis angle from the LED centerline where the luminous intensity is ½ of the peak value.
Electrical and Thermal Characteristics
Table 3. Electrical and thermal characteristics for LUXEON 5050 at test current, Tj=25°C.
Forward Voltage [1] (Vf)
Typical Thermal
Resistance—Junction
to Solder Pad (°C/W)
Minimum
Typical
MAXIMUM
Typical Temperature
Coefficient of Forward
Voltage [2] (mV/°C)
L150-xxxx502400000
23.5
24.5
26.5
-12
2
L150-xxxx500600000
5.8
6.1
6.6
-3
2
Part Number
Notes for Table 3:
1. Lumileds maintains a tolerance of ±1% on forward voltage measurements.
2. Measured between 25°C and 85°C.
Absolute Maximum Ratings
Table 4. Absolute maximum ratings for LUXEON 5050.
Parameter
Maximum Performance
DC Forward Current [1, 2]
240mA for 24V
800mA for 6V
Peak Pulsed Forward Current [1, 3]
300mA for 24V
1000mA for 6V
LED Junction Temperature [1] (DC & Pulse)
125°C
ESD Sensitivity (ANSI/ESDA/JEDEC JS-001-2012)
Class 2
Operating Case Temperature [1]
105°C
LED Storage Temperature
-40°C to 105°C
Reverse Voltage (Vreverse)
LUXEON LEDs are not designed to be driven in reverse bias
Notes for Table 4:
1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple,” are acceptable if the following conditions are met:
– The frequency of the ripple current is 100Hz or higher
– The average current for each cycle does not exceed the maximum allowable DC forward current
– The maximum amplitude of the ripple does not exceed the maximum peak pulsed forward current
3. At 10% duty cycle with pulse width of 10ms.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
4
Characteristic Curves
Spectral Power Distribution Characteristics
Figure 1a. Typical normalized power vs. wavelength for L150-xx7050xx00000 at test current, Tj=25°C.
Figure 1b. Typical normalized power vs. wavelength for L150-xx8050xx00000 at test current, Tj=25°C.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
5
Figure 1c. Typical normalized power vs. wavelength for L150-xx9050xx00000 at test current, Tj=25°C.
Light Output Characteristics
Figure 2. Typical normalized light output vs. junction temperature for L150-xxxx50xx00000 at test current.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
6
Figure 3a. Typical normalized light output vs. forward current for L150-xxxx502400000, Tj=25°C.
Figure 3b. Typical normalized light output vs. forward current for L150-xxxx500600000, Tj=25°C.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
7
Forward Current Characteristics
Figure 4a. Typical forward current vs. forward voltage for L150-xxxx502400000, Tj=25°C.
Figure 4b. Typical forward current vs. forward voltage for L150-xxxx500600000, Tj=25°C.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
8
Radiation Pattern Characteristics
Figure 5. Typical radiation pattern for L150-xxxx50xx00000 at test current, Tj=25°C.
Figure 6. Typical polar radiation pattern for L150-xxxx50xx00000 at test current, Tj=25°C.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
9
Product Bin and Labeling Definitions
Decoding Product Bin Labeling
In the manufacturing of semiconductor products, there are variations in performance around the average values given in the
technical datasheet. For this reason, Lumileds bins LED components for luminous flux or radiometric power, color point, peak or
dominant wavelength and forward voltage.
LUXEON 5050 LEDs are labeled using a 4-digit alphanumeric CAT code following the format below:
A B C C
Where:
A
–
designates luminous flux bin (example: H=450 to 500 lumens, L=600 to 650 lumens)
B
–
designates color bin (example: (example: 3=3 SDCM, 5=5 SDCM parts)
C C –
designates forward voltage bin (example: A1, A2, B1, B2)
Therefore, a LUXEON 5050 with a lumen range of 600 to 650, color bin of 3 and forward voltage range of 23.5 to 24.2V has the
following CAT code:
L3A1
Luminous Flux Bins
Table 5 lists the standard luminous flux bins for LUXEON 5050 LEDs. Although several bins are outlined, product availability in a
particular bin varies by production run and by product performance. Not all bins are available in all CCTs.
Table 5. Luminous flux bin definitions for LUXEON 5050, Tj=25°C.
Bin
Luminous Flux [1] (lm)
Minimum
Maximum
G
400
450
H
450
500
J
500
550
K
550
600
L
600
650
M
650
700
N
700
750
Notes for Table 5:
1. Lumileds maintains a tolerance of ±7% on luminous flux measurements.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
10
Color Bin Definitions
Figure 7. 3- and 5-step MacAdam ellipse illustration for hot-color targeting expected at 85°C.
Table 6. 3- and 5-step MacAdam ellipse color bin definitions for LUXEON 5050 at test current, hot-color targeted at Tj=85°C.
Nominal CCT
Color Space
Center Point [1]
(cx, cy)
Major Axis,
a
Minor Axis,
b
Ellipse Rotation
Angle, θ
2700K
Single 3-step MacAdam ellipse
(0.4578, 0.4101)
0.00810
0.00420
53.70°
3000K
Single 3-step MacAdam ellipse
(0.4338, 0.4030)
0.00834
0.00408
53.22°
3500K
Single 3-step MacAdam ellipse
(0.4073, 0.3917)
0.00927
0.00414
54.00°
4000K
Single 3-step MacAdam ellipse
(0.3818, 0.3797)
0.00939
0.00402
53.72°
5000K
Single 3-step MacAdam ellipse
(0.3447, 0.3558)
0.00822
0.00354
59.62°
5700K
Single 3-step MacAdam ellipse
(0.3287, 0.3417)
0.00745
0.00320
59.09°
6500K
Single 3-step MacAdam ellipse
(0.3123, 0.3282)
0.00669
0.00285
58.57°
2700K
Single 5-step MacAdam ellipse
(0.4578, 0.4101)
0.01350
0.00700
53.70°
3000K
Single 5-step MacAdam ellipse
(0.4338, 0.4030)
0.01390
0.00680
53.22°
3500K
Single 5-step MacAdam ellipse
(0.4073, 0.3917)
0.01545
0.00690
54.00°
4000K
Single 5-step MacAdam ellipse
(0.3818, 0.3797)
0.01565
0.00670
53.72°
5000K
Single 5-step MacAdam ellipse
(0.3447, 0.3558)
0.01370
0.00590
59.62°
5700K
Single 5-step MacAdam ellipse
(0.3287, 0.3417)
0.01243
0.00533
59.09°
6500K
Single 5-step MacAdam ellipse
(0.3123, 0.3282)
0.01115
0.00475
58.57°
Notes for Table 6:
1. Lumileds maintains a tolerance of ±0.01 on x and y coordinates in the CIE 1931 color space.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
11
Forward Voltage Bins
Table 7. Forward voltage bin definitions for LUXEON 5050, Tj=25°C.
PART NUMBER
L150-xxxx502400000
L150-xxxx500600000
Forward Voltage [1] (Vf)
Bin
Minimum
Maximum
A1
23.5
24.2
A2
24.2
25.0
B1
25.0
25.8
B2
25.8
26.5
A1
5.8
6.0
A2
6.0
6.2
B1
6.2
6.4
B2
6.4
6.6
Notes for Table 7:
1. Lumileds maintains a tolerance of ±1% on forward voltage measurements.
Mechanical Dimensions
Figure 8. Mechanical dimensions for LUXEON 5050.
Notes for Figure 8:
1. Drawings are not to scale.
2. All dimensions are in millimeters.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
12
Reflow Soldering Guidelines
tp
Tp
Critical Zone
TL to Tp
Ramp-up
TL
Temperature
tL
Tsmax
Tsmin
Ramp-down
ts
Preheat Area
25
Time 25ºC to Peak
JEDEC J-STD-020D
Time
Figure 9. Visualization of the acceptable reflow temperature profile as specified in Table 8.
Table 8. Reflow profile characteristics for LUXEON 5050.
PROFILE FEATURE
Lead-Free Assembly
Preheat Minimum Temperature (Tsmin)
150°C
Preheat Maximum Temperature (Tsmax)
200°C
Preheat Time (tsmin to tsmax)
60 to 180 seconds
Ramp-Up Rate (TL to Tp)
3°C / second maximum
Liquidus Temperature (TL)
217°C
Time Maintained Above Temperature TL (tL)
60 to 150 seconds
Peak / Classification Temperature (Tp)
260°C
Time Within 5°C of Actual Temperature (tp)
20 to 40 seconds
Ramp-Down Rate (Tp to TL)
6°C / second maximum
Time 25°C to Peak Temperature
8 minutes maximum
JEDEC Moisture Sensitivity
Table 9. Moisture sensitivity levels for LUXEON 5050.
level
3
Floor Life
Soak Requirements Standard
TIme
Conditions
Time
Conditions
168 Hours
≤30°C / 60% RH
192 Hours +5 / -0
30°C / 60% RH
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
13
Solder Pad Design
Figure 10. Recommended PCB solder pad layout for LUXEON 5050.
Notes for Figure 10:
1. Drawings are not to scale.
2. All dimensions are in millimeters.
Packaging Information
Pocket Tape Dimensions
Figure 11. Pocket tape dimensions for LUXEON 5050.
Notes for Figure 11:
1. Drawings are not to scale.
2. All dimensions are in millimeters.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
14
0.3
10
Front
0
51
Back
0. 3
Reel Dimensions
10
Back View
3
Front View
Figure 12. Reel dimensions for LUXEON 5050.
Notes for Figure 12:
1. Drawings are not to scale.
2. All dimensions are in millimeters.
DS174 LUXEON 5050 Product Datasheet 20180207 ©2018 Lumileds Holding B.V. All rights reserved.
15
About Lumileds
Companies developing automotive, mobile, IoT and illumination lighting applications need a partner who can collaborate with
them to push the boundaries of light. With over 100 years of inventions and industry firsts, Lumileds is a global lighting solutions
company that helps customers around the world deliver differentiated solutions to gain and maintain a competitive edge. As the
inventor of Xenon technology, a pioneer in halogen lighting and the leader in high performance LEDs, Lumileds builds innovation,
quality and reliability into its technology, products and every customer engagement. Together with its customers, Lumileds is
making the world safer, better and more beautiful—with light.
To learn more about our lighting solutions, visit lumileds.com.
©2018 Lumileds Holding B.V. All rights reserved.
LUXEON is a registered trademark of the Lumileds
Holding B.V. in the United States and other countries.
lumileds.com
DS174 LUXEON 5050
Product Datasheet 20180207
Neither Lumileds Holding B.V. nor its affiliates shall be liable for any kind of loss of data or any other damages,
direct, indirect or consequential, resulting from the use of the provided information and data. Although Lumileds
Holding B.V. and/or its affiliates have attempted to provide the most accurate information and data, the materials
and services information and data are provided “as is,” and neither Lumileds Holding B.V. nor its affiliates
warrants or guarantees the contents and correctness of the provided information and data. Lumileds Holding
B.V. and its affiliates reserve the right to make changes without notice. You as user agree to this disclaimer and
user agreement with the download or use of the provided materials, information and data. A listing of Lumileds
product/patent coverage may be accessed at lumileds.com/patents.
Similar pages