Series AMEPR50N-Z up to 1150mA | AC-DC LED driver FEATURES: • • • • • • • • Universal Input: 90~264 Vac High Efficiency: Up to 87% Active Power Factor Correction Short Circuit / Open Circuit Protection Meet UL, CE Safety Requirement Long Life, High reliability Ultra-low ripple without flickering 3-year limited warranty Models Single output Model Max Output Power (W) Output Voltage Range (V) 42.0 44.1 48.3 30-42 30-42 30-42 AMEPR50N-42100Z AMEPR50N-42105Z AMEPR50N-42115Z Output Current (mA) 1000 1050 1150 Input Voltage (VAC/Hz) Efficiency (%) 90-264/47-63 90-264/47-63 90-264/47-63 87.0 87.0 87.0 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Input Current Inrush current <2ms Conditions Typical 90 VAC, full load 115 VAC, cold start 230 VAC, cold start Leakage current Input dissipation Power Factor No Load Output Short 115 VAC, full load 230 VAC, full load Input Fuse Start-up Time Maximum Units 0.76 40 60 0.75 1.5 4.5 0.98 0.95 Arms 1.5 1.0 Sec. Sec. Maximum Units 200 50 % % % mV p-p mA 15 % 0.5 ms Rated 3750 Units VAC MΩ pF A mA W W 2A/250V 115 VAC, full load 230 VAC, full load Output Specifications Parameters Current accuracy Line regulation Load regulation Ripple & Noise Output Current Ripple Current Overshoot Conditions Typical LL to HL Full Output Voltage Range ±5 ±3 ±5 Full load LL to HL, full load at cold start, % of rated output current Hold-up time (min) Minimum Load Voltage Isolation Specifications Parameters Tested I/O voltage Isolation Resistance Isolation Capacitance See Models Table Above Conditions I/P – O/P 500Vdc Typical >100 100 General Specifications Parameters Switching frequency Over voltage protection Short circuit protection Short circuit restart Open circuit protection www.aimtec.com F 052.1e R1 Conditions Typical Maximum Units 150 50 KHz V Continuous, Hiccup Mode Auto Recovery Continuous, Hiccup Mode Tel: +1 514 620 2722 1 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR50N-Z up to 1150mA | AC-DC LED driver Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material IP Rating Weight Dimensions (L X W+ X H) MTBF Without Derating oC -40 to +50 90 -40 to +85 oC oC 0.03 % / oC 90 % RH Free Air Convection Plastic IP54 260 6.30 X 1.73 X 1.61 inches 160.00 X 44.00 X 41.00 mm 300,000 hrs (MIL-HDBK-217F at +25°C) g Safety Specifications Parameters Electromagnetic Interference Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient / Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Electromagnetic Immunity Requirements Applies to Lighting Equipment Standards EN55015 / FCC Part 15, Class B EN61000-3-2, Class B EN61000-3-3 EN61000-4-2, 8kV Air, 4kV Contact, Level 3, Criteria A EN61000-4-3, Test-RS Level 3, Criteria A EN61000-4-4, Burst EFT Level 3, Criteria A EN61000-4-5, Line to Neutral 4kV, Neutral to FG 6kV EN61000-4-6. Test-CS Level 3, Criteria A EN61000-4-8, Test 3A/m, Criteria A EN61000-4-11, Criteria B EN61547 Pin Definition Pin AC-N AC-L LED+ LED- Specification / Termination Blue Color, Wire Gauge #18 Brown Color, Wire Gauge #18 The central pin of DC5521 Plug, Connected to the internal red wire The external Cylinder pin of DC5521 Plug , Connected to internal black wire Block diagram AC1 LED+ 1st LED AC LED AC2 www.aimtec.com F 052.1e R1 LED LED- Tel: +1 514 620 2722 2 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR50N-Z up to 1150mA | AC-DC LED driver Dimensions Top View 147.5 5.81 106.0 4.17 15±5 0.59±0.20 180±10 7.09±0.39 10.0 0.39 4.0 0.16 5±1 0.20±0.04 44.0 1.73 32.0 1.26 AWM E355456 STYLE 2464 18AWG VW-ISO 80°C 300V 10±1 0.39±0.04 105±5 4.13±0.20 160.0 6.30 DC5521 32±2 1.26±0.08 Side View Black 41.0 1.61 Red 2.10(0.08) 5.45(0.21) Efficiency Vs. Input Voltage & Output Load Voltage AMEPR50N-42100Z 95.00% 90.00% Efficiency 85.00% 80.00% 115VAC 75.00% 230VAC 70.00% 65.00% 30 www.aimtec.com F 052.1e R1 33 36 Output Voltage(V) 39 42 Tel: +1 514 620 2722 3 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR50N-Z up to 1150mA | AC-DC LED driver AMEPR50N-42105Z 95.00% 90.00% Efficiency 85.00% 80.00% 115VAC 75.00% 230VAC 70.00% 65.00% 30 33 36 Output Voltage(V) 39 42 AMEPR50N-42115Z 95.00% 90.00% Efficiency 85.00% 80.00% 115VAC 230VAC 75.00% 70.00% 65.00% 30 33 36 39 42 Output Voltage(V) www.aimtec.com F 052.1e R1 Tel: +1 514 620 2722 4 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR50N-Z up to 1150mA | AC-DC LED driver PF vs. Input Voltage & Output Load Voltage AMEPR50N-42100Z 1.200 PF 0.900 0.600 115VAC 230VAC 0.300 0.000 30 33 36 39 42 Output Voltage(V) AMEPR50N-42105Z 1.200 PF 0.900 0.600 115VAC 230VAC 0.300 0.000 30 33 36 39 42 Output Voltage(V) www.aimtec.com F 052.1e R1 Tel: +1 514 620 2722 5 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR50N-Z up to 1150mA | AC-DC LED driver AMEPR50N-42115Z 1.200 PF 0.900 0.600 115VAC 230VAC 0.300 0.000 30 33 36 39 Output Voltage(V) 42 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R1 Tel: +1 514 620 2722 6 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only