Cooper CBF-35 Automotive circuit breaker Datasheet

Consumer Aftermarket Catalog
Automotive Circuit Breakers
Cooper Bussmann offers the industry's largest selection of automotive
circuit breakers including both OEM-style and fuse-replacement devices.
Circuit breakers are designed to offer a variety of performance
characteristics including three types of reset.
(NOTE: Always follow the OEM's recommendations when replacing circuit
breakers. Replace only with the same type breaker in aftermarket
applications.)
Type I - Automatic Reset
ATM Footprint Breakers
CB211 and CB212 Cooper Bussmann ATM footprint breakers match the
blade footprint of ATM fuses. Ultra-thin, to fit in tight spaces - they're the
smallest automotive circuit breakers on the market. Cooper Bussmann ATM
footprint breakers comply with SAE standard J553.
CB211 Type I ATM Footprint Circuit Breaker
Part No.
(Amps)
Blister
Pack
Circuit breaker automatically resets after opening. If the fault still exists, the
breaker will continue to cycle between ON and OFF positions until the
overload is corrected. These devices are sometimes called "cycling
breakers." Type I/Automatic Reset circuit breakers do not address, or
correct, overcurrent or fault conditions. They only react by cycling OFF and
ON. Any overcurrent or fault condition that causes any Type I circuit breaker
to operate should be corrected as soon as possible. Continual vehicle
operation under an overcurrent or fault condition (causing the Type I circuit
breaker to cycle) is NOT recommended.
Type II - Modified Reset
CB212 Type II ATM Footprint Circuit Breaker
The circuit breaker will remain tripped (in the OFF position) as long as
there's power to the circuit, due to an internal resistor. Type II breakers can
be reset by turning off the circuit, or by turning off the ignition switch. These
devices are sometimes called "non-cycling breakers." Several Cooper
Bussmann Type II breakers feature silver-colored bodies.
Type III - Manual Reset
CB212-10
CB212-15
CB212-20
CB212-25
CB212-30
The circuit breaker will remain tripped (in the OFF position) until an indicator
button or lever is manually reset. Type III breakers are also available with a
switchable feature, which allows you to use an external button to disable the
circuit. Cooper Bussmann circuit breakers feature our patented fail-safe
technology - offering an innovative element design which combines the
resetable performance of circuit breakers with the short-circuit protection of
a fuse.
• Resetable, to work like a normal "cycling" breaker, in low overload
conditions.
• Under severe overload or short-circuit conditions, the breaker's element
will open to prevent damage to the circuit.
Blade-Type Breakers
Cooper Bussmann blade-type circuit breakers are available in several reset
modes that correspond to SAE categories: SAE Type I (automatic reset), SAE
Type II (modified reset) and SAE Type III (manual reset). All Cooper
Bussmann blade-type circuit breakers utilize carefully designed and
manufactured snap-acting thermal elements with precious metal electrical
contacts.
December 11, 2008
CB211-71/2
CB211-10
CB211-15
CB211-20
CB211-25
CB211-30
X
X
X
X
X
Part No. (Amps)
MMB Type I Wide ATM Footprint Circuit Breaker
For GM Vehicles
Part No. (Amps)
OEM No.
MMB-15
MMB-20
12135171
12135072
Mini Devices
Transorb, resistor and diode vehicle-style electrical protection devices easily
install in common ATM fuse holders. These circuit protection devices provide
voltage and current limiting functionality to
vehicle circuitry; and are designed for the
on- and off-highway requirements of heavy
trucks, RV, construction, agriculture, ATV and
material handling equipment.
• Transorb - Protects against voltage
spikes. Clamp rating: 27Vdc.
Power rating: 1500W
• Resistor - Drops circuit voltage.
Power rating: 5W. Resistance: 68Ω.
• Diode - Prevents reverse current flow. Amp rating: 6A.
Part No.
Description
CB22901-1.5
CB22902-68
CB22903-6
CB22903-6V
Transorb voltage spike protector
Resistor voltage drop device
Diode reverse current protector
Diode reverse current protector with wing key
For product information and Data Sheets, visit www.cooperbussmann.com
11
Consumer Aftermarket Catalog
Automotive Circuit Breakers
ATC Breakers
CB221 and CB222 breakers are designed to fit ATC style fuse panels.
Cooper Bussmann ATC breakers are the thinnest available in the
aftermarket. These devices comply with SAE standard J553.
CCB-25 Type I ATC Footprint Circuit Breaker For
Chrysler Vehicles
CB227 complies with SAE J553 and SAE J1171 for ignition protection.
Part No. (Amps)
OEM No.
Cooper Bussmann also offers three ATC-style breakers as replacement
parts for specific OEM applications - ACB-20, CCB-25, and FCB-20.
BP/CCB-25
4527053
ACB-20 Type I ATC Footprint Circuit Breaker for GM Vehicles
Part No. (Amps)
Blister Pack
OEM No.
X
12040816
ACB-20
CBB-30 Type II ATC Footprint Circuit Breaker
Part No. (Amps) Blister Pack
CBB-30
X
CB221 Type I ATC Footprint Circuit Breakers
Part No. (Amps)
CB221-71/2
CB221-10
CB221-15
CB221-20
CB221-25
CB221-30
FCB-20 Type II ATC Footprint Circuit Breaker for Ford Vehicles
Part No. (Amps)
CB222 Type II ATC Footprint Circuit Breakers
BP/FCB-20
OEM No.
D9AB-14526-BA
Part No. (Amps)
CB222-10
CB222-15
CB222-20
CB222-25
CB222-30
CB223 Type III ATC Footprint Circuit Breakers
Part No. (Amps)
UCB breakers feature "snap-off" universal blades that can easily be sized to
fit applications where fuse block spacing is tight, or the fuse terminal is
recessed.
CB223-71/2
CB223-10
CB223-15
CB223-20
CB223-25
CB223-30
CB227 Type III ATC Footprint Low-Profile Circuit Breakers
Color
Code
Part No.
(Amps)
Tan
Moss Green
Brown
Red
Blue
Yellow
White
Green
CB227-5
CB227-6
CB227-71/2
CB227-10
CB227-15
CB227-20
CB227-25
CB227-30
12
UCB Type I ATC Footprint Circuit Breakers
Color
Code
Part No.
(Amps)
Blister
Pack
Plain
Brown
Red
Blue
Yellow
Plain
Green
UCB-6
UCB-8
UCB-10
UCB-15
UCB-20
UCB-25
UCB-30
X
X
X
X
X
X
X
For product information and Data Sheets, visit www.cooperbussmann.com
Tri-Lingual
Blister
X
X
December 11, 2008
Consumer Aftermarket Catalog
Automotive Circuit Breakers
Maxi Breakers
Heavy-Duty Breakers
Identical in size to Maxi-style fuses. The only breakers on the
market to match the Maxi's footprint and body dimensions.
Used in many heavy-duty and truck applications. Use ring terminals to
connect breaker into circuit. CBS are standard-duty and CBC are heavy-duty
type breakers.
CB1911 Type I MAX Footprint Circuit Breakers
Part No. (Amps)
CB1911-10
CB1911-15
CB1911-20
CB1911-25
CB1911-30
CB1911-35
CB1911-40
CB1911-50
Cooper Bussmann stud-type circuit breakers feature our patented fail-safe
technology, and are available in styles: without bracket; with mounting
bracket; waterproof, with mounting bracket and with combination blade and
stud terminals. Complies with SAE standard J553.
CB123-B Type III 10-32 Stud-Mount Circuit Breakers with
Crosswise Bracket and Cover
Part No. (Amps)
CB123-10B
CB123-15B
CB123-20B
CB123-30B
CB123-40B
CB123-50B
CB1921 Type II MAX Footprint Circuit Breakers
Part No. (Amps)
CB123-HB Type III 10-32 Stud-Mount Circuit Breakers with
Lengthwise Bracket and Cover
Part No. (Amps)
CB1921-10
CB1921-15
CB1921-20
CB1921-25
CB1921-30
CB123-10HB
CB123-15HB
CB123-20HB
CB123-30HB
CB123-40HB
CB123-50HB
CBC Type I 10-32 Stud-Mount Circuit Breakers
Part No. (Amps)
Glass Tube Breakers
CBF Type II Circuit Breakers For Use In Glass Tube Fuse Holders
and Blocks
CBF circuit breakers can be used to replace glass fuses in 1/4” x 11/4” small
dimension fuse blocks.
Part No. (Amps)
CBF-6
CBF-10
CBF-15
CBF-20
CBF-25
CBF-30
CBF-35
CBF-40
December 11, 2008
Blister Pack
X
X
X
X
X
X
CBC-8
CBC-10
CBC-15
CBC-20
CBC-25
CBC-30
CBC-35
CBC-40
CBC-50
CBC-B Type I 10-32 Stud-Mount Circuit Breakers with
Crosswise Bracket
Part No.
(Amps)
Blister
Pack
CBC-8B
CBC-10B
CBC-15B
CBC-20B
CBC-25B
CBC-30B
CBC-35B
CBC-40B
CBC-50B
X
X
X
X
X
X
Tri-Lingual
Blister
X
For product information and Data Sheets, visit www.cooperbussmann.com
13
Consumer Aftermarket Catalog
Automotive Circuit Breakers
Quick-Connect Breakers
CBC-BWP Type I 10-32 Stud-Mount
Weatherproof Circuit Breakers
Used in trucks, RVs, boats, buses, etc. offered with 1/4" quick-connect or 90°
bent screw terminals.
Part No. (Amps)
CBC-20BWP
CBC-30BWP
CBT-M Type II Circuit Breakers For Mack Trucks with
1
/4" Blades on 1" Centers
CBC-HB Type I 10-32 Stud-Mount Circuit Breakers with
Lengthwise Bracket
Part No.
(Amps)
CBC-10HB
CBC-15HB
CBC-20HB
CBC-25HB
CBC-30HB
CBC-40HB
CBC-50HB
Part No. (Amps)
CBT-10M
CBT-15M
CBT-20M
CBT-25M
CBT-30M
Blister
Pack
X
X
X
X
CBT-N Type II Circuit Breakers For Navistar Trucks with
1
/4" Blades on 1.08" Centers
Part No. (Amps)
CBP-BA Type I 10-32 Stud-Mount Circuit Breakers with
Crosswise Bracket
Part No. (Amps)
CBP-20BA
CBP-25BA
CBP-30BA
CBP-40BA
CBP-50BA
CBT-10N
CBT-15N
CBT-20N
CBT-25N
CBT-30N
CBU Type I Circuit Breakers with 1/4" Quick-Connect Terminals on
0.99" Centers (30B with crosswise bracket)
Panel-Mount Breakers
Part No. (Amps)
Used in trucks, RVs, boats, buses, etc. offered with 1/4" quick-connect or
90° bent screw terminals.
CB174 Type III Circuit Breakers with 1/4" Quick-Connect
Terminals
CBU-6
CBU-30B
Part No. (Amps)
CBU-30B
CB174-8
CB174-10
CB174-15
CB174-20
CB174-25
CB174-30
CBU-6
CB174B Type III Circuit Breakers with 90° 5-32 Screw Terminals
Part No. (Amps)
CB174B-10
CB174B-15
CB174B-20
CB174B-25
CB174B-30
CB174B-40
14
For product information and Data Sheets, visit www.cooperbussmann.com
December 11, 2008
Consumer Aftermarket Catalog
Automotive Circuit Breakers
High Amp Circuit Breakers
Marine-Rated Circuit Breakers
These high amp circuit breakers are typically used in auxiliary and
accessory circuits for trucks, buses, RVs and marine applications. All high
amp circuit breakers comply with the SAE J1117 standard for ignition
protection and have applications in battery charger systems and DC audio
systems. Offered in flush-mount or panel-mount (see chart for amps
available).
CB181F Type I High Amp Waterproof Circuit Breakers with SEMS
Nut Installed
Part No. (Amps)
CB187F-25
CB187F-30
CB187F-35
CB187F-40
CB187F-50
CB187F-60
CB187F-70
Part No. (Amps)
CB181F-60
CB181F-70
CB181F-80
CB181F-90
CB181F-100
Specifically designed to meet the needs of marine applications, the CB187F
and CB187P offer 5kA interrupting ratings and ignition protection per ABYC
E-11. Usable as an ON/OFF switch (capable of withstanding 3000 on/off
cycles @48Vdc), they have corrosion resistant plating on 5/16-18 copper
terminals.
CB187F Type III Marine-Rated Surface-Mount Manual Reset
Circuit Breaker with Switch Function
CB181F-110
CB181F-120
CB181F-135
CB181F-150
CB187F-80
CB187F-90
CB187F-100
CB187F-110
CB187F-120
CB187F-135
CB187F-150
CB184F Type III High Amp Waterproof Manual Reset Circuit
Breakers with SEMS Nut Installed
CB187P Type III Marine-Rated Panel-Mount Manual Reset Circuit
Breaker with Switch Function
Part No. (Amps)
CB184F-25
CB184F-30
CB184F-35
CB184F-40
CB184F-50
CB184F-60
CB184F-70
CB184F-80
CB184F-90
CB184F-100
CB184F-110
CB184F-120
CB184F-135
CB184F-150
Part No. (Amps)
CB187P-25
CB187P-30
CB187P-35
CB187P-40
CB187P-50
CB187P-60
CB187P-70
CB187P-80
CB187P-90
CB187P-100
CB187P-110
CB187P-120
CB187P-135
CB187P-150
CB185 Type III High Amp Switchable, Waterproof, Flush-Mount
Manual Reset Circuit Breakers with SEMS Nut Installed
Part No. (Amps)
CB185-25
CB185-30
CB185-35
CB185-40
CB185-50
CB185-60
CB185-70
CB185-80
CB185-90
CB185-100
CB185-110
CB185-120
CB185-135
CB185-150
Blister Pack
CB251 Type I Ignition Protected Weatherproof Panel-Mount
Manual Reset Circuit Breaker, 32Vdc
Part No. (Amps)
X
CB251-10
CB251-15
CB251-20
CB251-25
X
X
CB251-30
CB251-35
CB251-40
CB251-50
X
X
X
X
CB185P Type III High Amp Switchable, Panel Mount Manual
Reset Circuit Breakers with SEMS Nut Installed
CB255 Type III Ignition Protected Weatherproof Panel-Mount
Manual Reset Circuit Breaker with “Push-to-Trip” Option, 32Vdc
Part No. (Amps)
Part No. (Amps)
CB185P-25
CB185P-30
CB185P-35
CB185P-40
CB185P-50
CB185P-60
CB185P-70
December 11, 2008
CB185P-80
CB185P-90
CB185P-100
CB185P-110
CB185P-120
CB185P-135
CB185P-150
CB255-10
CB255-15
CB255-20
CB255-25
CB255-30
CB255-35
CB255-40
CB255-50
For product information and Data Sheets, visit www.cooperbussmann.com
15
Similar pages