Keysight Technologies M9341A PXIe Digital I/O M9341B PXIe Digital/Analog I/O Data Sheet 02 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet M9341A Overview The Keysight M9341A Digital I/O with the 24-bit digital I/O connector and triggering ports provides communication signals between the PXI vector network analyzer (VNA) installed in the same PXI chassis and an external handler. This allows the PXI VNA such as the Keysight M937xA and M9485A to be used in an automated test environment, where devices to be tested are inserted into a test fixture by a part handler, and sorted into pass/fail bins by the handler after testing is complete. By connecting the part handler to the M9341A digital I/O connector, the VNA and part handler can synchronize their activities in a way that makes automated testing possible. The M9341A digital I/O also compatible with the 24-bit digital I/O connector on the rear panel of the Keysight PNA and ENA Series. Key specifications/features –– Digital I/O for communication for the PXI VNA with external peripherals (i.e. handler) –– Synchronized measurements with the PXI VNA in an automated test environment –– Compatible with the 24-bit digital I/O connector on the PNA and ENA 03 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet M9341B Overview The Keysight M9341B PXIe Digital and Analog I/O is equipped with a 24-bit digital I/O and an 8-bit digital I/O to allow users to control the device under test (DUT) directly with serial or parallel digital signals1. For example, the signals from the M9341B can be applied to select operation modes of the RF front-end module which integrates power amplifiers, switches, low noise amplifiers, duplexer or filters in a single component. The operation with the M9341B is synchronized with the measurement sweep by the Keysight PXI VNA such as the M937xA Series or the M9485A, greatly improving measurement throughput. For more comprehensive analysis, the M9341B has four analog input connectors to allow sensing of DC voltages from the DUT. The measured DC voltage can be displayed on the PXI VNA screen. The 1-slot module also supports two variable DC source outputs to control the DUT, while the DC source current can be monitored during measurements. Key specifications/features –– 8-bit digital I/O for controlling DUT operation mode with serial/parallel signals –– 24-bit digital I/O for communication for the PXI VNA with external peripherals (i.e. handler) –– Synchronized DC measurements with the PXI VNA. Two DC source outputs (up to ±10 V) with current monitor functions and four DC source inputs for sensing DC voltages from the DUT 1. Serial signals from 8-bit I/O can provide up to 4-channels RFFE-like interface with software selectable clock rate (25 MHz maximum). Please refer to the help file for detail. 04 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet Specifications Definitions Specification (spec.): Warranted performance. All specifications apply at 25 ºC (± 5 ºC) range ambient and module temperature between 27 ºC to 39 ºC as reported by the module, unless otherwise stated, and 45 minutes after the module has been turned on.1 Specifications include guard bands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. Typical (typ.): Expected performance of an average unit which does not include guardbands. General Characteristics: A general, descriptive term that does not imply a level of performance. Boundary Conditions: If the same boundary conditions fall under more than one category in a table, apply the best value. 1. Not only chassis power on but also VNA firmware execution is required to turn on the module. 05 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet 24 Bit Digital I/O Specification Description General Characteristics Connector Type CHAMP 0.8mm, 36 pos Receptacle Input Signal Logic Input Voltage Range High-level Input Voltage Low-level Input Voltage 3.3 V TTL -0.5 V to + 5.5 V +2.0 V Min +0.8 V Max Output Signal Logic High-level Output Current Low-level Output Current Output Impedance Typical 1 3.3 V TTL -5 mA +3 mA 100 Ω Power Supply Output Voltage Maximum Output Current +4.5 V min, +5.5 V max 100 mA 8 Bit Digital I/O Specification (M9341B Only) Description General Characteristics Connector Type ST series, 10 pos receptacle Power Supply (VIO)2 Output Voltage Voltage Accuracy Maximum Output Current Input Signal Input Voltage Range Minimum High-level Input Voltage Maximum Low-level Input Voltage Output Signal Minimum High-level Output Voltage Maximum Low-level Output Voltage Typical +3.3 V, +1.8 V, or +1.2 V ±5% 100 mA 0 V to VIO +2.0 V (at VIO = +3.3 V) +1.17 V (at VIO = +1.8 V) +0.78 V (at VIO = +1.2 V) +0.8 V (at VIO = +3.3 V) +0.63 V (at VIO = +1.8 V) +0.42 V (at VIO = +1.2 V) VIO - 0.1 V (at Io = -100μA) +0.1 V (at Io = 100μA) 1. M9341A-001 provides conversion cable to the 36-pin centronics, female which is compatible with ENA and PNA handler I/F. 2. Some wait time may be required until the voltage reaches the setting value at voltage setting change. See help for more detail. 06 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet Analog I/O Specification (M9341B Only) Description Input Ports Number of Ports Connector Type Input Voltage Range Input Impedance Measurement Accuracy1 Specification 4 MCX female ±10 V, ±5 V, and ±1 V (selectable) 10 MΩ (nom), > 1 kΩ (at power off state) At measurement time = 10 ms ±(0.1% reading + 0.2% range) Damage Level Output Ports Number of Ports Connector Type Output Voltage Range Output Voltage Resolution Maximum Output Current Output Impedance (at Port) Output Voltage Ripple and Noise Output Voltage Accuracy1, 2 Typical/ General Characteristics ±15 V 2 MCX female ±10 V 1 mV Mode 1: ±500 mA (Port 1) and ±100 mA (Port 2) Mode 2: ±50 mA (Ports 1 and 2) ±(0.2% + 20 mV) at no load with user compensation Output Current Monitor Accuracy Mode 1: 0 Ω (nom), Mode 2: 50 Ω (nom) 2 mVrms (20 Hz – 20 MHz) ±(0.14% + 14 mV) at no load with user compensation ±(0.42% + 40 mV) at no load without user compensation At measurement time = 10 ms Mode 1: ±(1% + 7 mA) Mode 2: ±(1% + 1 mA) Sync Ports Specification Description Connector Type Sync 1 to 3 SMB male Logic Typical 3.3 V TTL Miscellaneous Description General Characteristics Size 1 PXIe slot, compatible with PXI hybrid slots Dimensions 212 mm x 20 mm x 128 mm Weight (net) 330 g (M9341A), 490 g (M9341B) Power Drawn from Chassis3 5.2 W max (M9341A), 32.0 W max (M9341B) +3.3 V: 0.73 A (M9341A), 2.80 A (M9341B) +5 V: 0 A +12 V: 0.23 A (M9341A), 1.96 A (M9341B) -12 V: 0 A 1. This specification is applied at single usage in the chassis and may be affected by grounding condition. 2. Validation of user compensation: 1 hour and ±3 °C from user compensation. Additional error (typ): 6 mV at 100 mA output (load ≥ 12.1 Ω); 21 mV at 500 mA output (load ≥ 2.2 Ω) 3. At maximum load: Output current from Analog Out Port 1, Analog Out Port 2, +5VIO of 24-bit I/O, and VIO of 8-bit I/O are 500 mA, 100 mA, 100mA, and 100 mA, respectively. 07 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet General Characteristics EMC, safety, environment and compliance Description Specification EMC European Council Directive 2014/30/EC IEC 61326-1:2012 EN 61326-1:2013 CISPR 11:2009 +A1:2010 EN 55011: 2009 +A1:2010 Group 1, Class A IEC 61000-4-2:2008 EN 61000-4-2:2009 4 kV CD / 8 kV AD IEC 61000-4-3:2006 +A1:2007 +A2:2010 EN 61000-4-3:2006 +A1:2008 +A2:2010 3 V/m, 80-1000 MHz, 1.4 - 2.0 GHz / 1V/m, 2.0 - 2.7 GHz, 80% AM IEC 61000-4-4:2004 +A1:2010 EN 61000-4-4:2004 +A1:2010 2 kV power lines / 0.5 kV signal lines IEC 61000-4-5:2005 EN 61000-4-5:2006 1 kV line-line / 2 kV line-ground IEC 61000-4-6:2008 EN 61000-4-6:2009 3 V, 0.15-80 MHz, 80% AM IEC 61000-4-8:2009 EN 61000-4-8:2010 30A/m, 50/60Hz IEC 61000-4-11:2004 EN 61000-4-11:2004 0.5-300 cycle, 0% / 70% ICES-001:2006 Group 1, Class A AS/NZS CISPR11:2004 Group 1, Class A 08 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet General Characteristics continued EMC, safety, environment and compliance Description Specification KN11, KN61000-6-1 and KN61000-6-2 Group 1, Class A South Korean Class A EMC declaration: Information to the user: This equipment has been conformity assessed for use in business environments. In a residential environment this equipment may cause radio interference. ※ This EMC statement applies to the equipment only for use in business environment. Environment This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as a “Monitoring and Control instrumentation” product. Do not dispose in domestic household waste. To return unwanted products, contact your local Keysight office 09 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet General Characteristics continued Analyzer environmental specifications Operating environment General characteristics Temperature 0 to 55 °C ambient 0 to 55 °C module temperature Humidity 20% to 80% at wet bulb temperature < +29 °C (non-condensation) Altitude 0 to 2,000 m (0 to 6561 feet) Vibration 0.21 G maximum, 5 Hz to 500 Hz Non-operating environment General characteristics Temperature -40 °C to +70 °C Humidity 20% to 90% at wet bulb temperature < +40 °C (non-condensation) Altitude 0 to 4,572 m (0 to 15,000 feet) Vibration 0.5 G maximum, 5 Hz to 500 Hz Dimensions 19.9 M9341A 83.3 59.3 49.3 39.3 29.3 4.3 34.5 9.7 M9341A Digital I/O Status S ync 1 S ync 2 S ync 3 130 S ync 4 24 Bit Digital I/O 2.7 6.3 19.9 34.5 M9341B Digital/A nalog I/O Status Sync 1 Sync 2 Sync 3 Sync 4 Analog Out 1 34.3 59.3 67.3 75.3 83.3 91.3 99.3 9.9 8 Bit Digital I/O 83.3 59.3 49.3 39.3 29.3 13.4 4.3 130 M9341B 2 In 1 24 Bit Digital I/O 2 3 4 6.3 14.6 3.1 10 | Keysight | M9341A PXIe Digital I/O, M9341B PXIe Digital/Analog I/O - Data Sheet Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument’s lifecycle. Our comprehensive service offerings—onestop calibration, repair, asset management, technology refresh, consulting, training and more—helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/products/m9341a www.keysight.com/products/m9341b For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2017 Published in USA, December 1, 2017 5992-1856EN www.keysight.com