Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch PART NUMBER DESCRIPTION CCR-39S Commercial Latching Multi-throw, DC-18GHz CR-39S Elite Latching Multi-throw, DC-22GHz The CCR-39S/CR-39S is a broadband, multi-throw, electromechanical coaxial switch designed to switch a microwave signal from a common input to any of 3, 4, 5, or 6 outputs. The characteristic impedance is 50 Ohms. The switches are small using the popular connector spacing on a 1.062” dia. circle. Each position has an individual actuator mechanism allowing random position selection. This also minimizes switching time. The CCR-39S/CR-39S comes with a latching actuator. The latching switch remains in the last position selected when the switch is de-energized. STD dual command requires a reset pulse before a new selected position. A separate reset circuit allows all positions to be set to an open position. User must provide both reset (clear) and set (select new position) commands. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS Operating Temperature Commercial Model, CCR-39S Elite Model, CR-39S Form Factor –40°C to 65°C –55°C to 85°C Multi-Throw, break before make Vibration (MIL-STD-202 Method 214, Condition D, non-operating) 10 g’s RMS Frequency Range CCR-39S CR-39S DC–18 GHz DC–22 GHz Shock (MIL-STD-202 Method 213, Condition D, non-operating) 500 g’s Characteristic Impedance 50 Ohms Operate Time 20 ms (max.) Standard Actuator Life Actuator Life w/ Additional Features 5,000,000 cycles 1,000,000 cycles Connector Type SMA Humidity (Moisture Seal) Available Weight 6 oz. (170.1g) (max.) Actuation Voltage Available 12 Actuation Current 15 24 255 205 130 Reset Current (# of Positions) 28 V 90 mA 3 765 615 390 270 mA 4 1020 820 520 360 mA 5 1275 1025 650 450 mA 6 1530 1230 780 540 mA PERFORMANCE CHARACTERISTICS Frequency DC–4 GHz 4–8 GHz 8–12 GHz 12–16 GHz 16-20 GHz 20-22 GHz 0.1 0.2 0.2 0.3 0.3 0.4 Insertion Loss, dB, max. Isolation, dB, min. VSWR , max. 80 80 80 80 75 70 1.05:1 1.1:1 1.2:1 1.2:1 1.2:1 1.2:1 PART NUMBERING SYSTEM CCR-39 S 6 6 C - T ** Series Options Connectors Actuator Type Actuator Voltage Number of Positions CONNECTOR ACTUATOR VOLTAGE NUMBER OF POSITIONS ACTUATOR TYPE OPTIONS S: SMA FEMALE 6: 28 VDC LATCHING 3: SP3T 0: NO INDICATOR CONTACTS T: TTL DRIVERS WITH DIODES 7: 15 VDC LATCHING 4: SP4T C: INDICATOR CONTACTS D: COIL TRANSIENT SUPPRESSION DIODES 8: 12 VDC LATCHING 5: SP5T R: POSITIVE 9: 24 VDC LATCHING 6: SP6T TD: DECODERS AND TTL DRIVERS WITH + COMMON DIODES **SEE PARTS LIST ON PAGE 11-13 M: MOISTURE SEAL S: D-SUB CONNECTOR* For additional options, please contact factory. © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com * D-Sub Connector may be 9 or 15 pin depending on number of throws. (See Connector Pinout page) CCR-39S/CR-39S Page 1 CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch SCHEMATICS AND MECHANICAL OUTLINE Analog TTL Indicators 14X SOLDER TERMINALS SOLDER WIRE MAXIMUM TEMP 250ºC FOR NO MORE THAN 5 SEC SP3T SP5T SP6T SP4T H = 2.25 STD & Indicator Model H = 2.50 All OTHER Models “-S OPTION” 9-PIN D-SUB OR 15-PIN D-MICRO CONNECTOR (EXAMPLE: CCR-39S/CR-39S Page 2 CCR-39S660-S) SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch CONNECTOR PINOUT FOR LATCHING SP3T MULTI-THROW SWITCHES EXAMPLE CR-39S630-S CR-39S63C-S INDICATOR TTL DECODERS & TTL PIN NO. CR-39S630-TS CR-39S63C-TS YES YES YES YES CR-39S630-TDS CR-39S63C-TDS YES 1 YES YES 9-PIN 9-PIN 9-PIN 15-PIN 9-PIN 9-PIN 1 PORT 1 PORT 1 TTL 1 TTL 1 LOGIC 1 LOGIC 1 2 PORT 2 PORT 3 PORT 2 PORT 3 TTL 2 TTL 3 TTL 2 TTL 3 LOGIC 2 LOGIC 3 LOGIC 2 LOGIC 3 3 4 5 E INDICATOR F INDICATOR 6 7 8 9 10 G INDICATOR COMMON RESET COMMON RESET COMMON RESET COMMON COMMON D INDICATOR (COM) D INDICATOR (COM) VSW VSW VSW VSW N/A N/A CR-39S640-TDS CR-39S64C-TDS YES 1 9 D INDICATOR (COM) 11 12 13 9-PIN D-SUB CONNECTOR E INDICATOR F INDICATOR G INDICATOR COMMON RESET 6 E INDICATOR N/A N/A N/A F INDICATOR G INDICATOR 15-PIN D-SUB CONNECTOR 14 15 CONNECTOR PINOUT FOR LATCHING SP4T MULTI-THROW SWITCHES EXAMPLE INDICATOR TTL DECODERS & TTL CR-39S640-S CR-39S64C-S YES CR-39S640-TS CR-39S64C-TS YES YES YES YES YES PIN NO. 1 2 3 4 9-PIN PORT 1 PORT 2 PORT 3 PORT 4 15-PIN PORT 1 PORT 2 PORT 3 PORT 4 9-PIN TTL 1 TTL 2 TTL 3 TTL 4 15-PIN TTL 1 TTL 2 TTL 3 TTL 4 9-PIN LOGIC 1 LOGIC 2 LOGIC 3 9-PIN LOGIC 1 LOGIC 2 LOGIC 3 5 6 7 COMMON COMMON RESET COMMON RESET COMMON RESET COMMON RESET COMMON 8 VSW VSW VSW VSW D INDICATOR (COM) E INDICATOR F INDICATOR 9 10 11 12 13 14 15 N/A D INDICATOR (COM) E INDICATOR F INDICATOR G INDICATOR H INDICATOR N/A D INDICATOR (COM) E INDICATOR F INDICATOR G INDICATOR H INDICATOR N/A G INDICATOR H INDICATOR CONNECTOR PINOUT FOR LATCHING SP5T MULTI-THROW SWITCHES EXAMPLE CR-39S650-S CR-39S65C-S TTL DECODERS & TTL PIN NO. 1 2 CR-39S650-TS CR-39S65C-TS YES YES YES 15-PIN PORT 1 9-PIN TTL 1 15-PIN TTL 1 PORT 2 PORT 3 PORT 4 PORT 5 TTL 2 TTL 3 TTL 4 TTL 5 COMMON RESET YES INDICATOR 9-PIN PORT 1 PORT 2 3 4 5 6 PORT 3 PORT 4 PORT 5 7 COMMON 8 9 10 11 12 13 14 15 RESET N/A D INDICATOR (COM) E INDICATOR F INDICATOR G INDICATOR H INDICATOR K INDICATOR CR-39S650-TDS CR-39S65C-TDS YES YES 9-PIN LOGIC 1 YES 15-PIN LOGIC 1 TTL 2 TTL 3 TTL 4 TTL 5 LOGIC 2 LOGIC 3 LOGIC 2 LOGIC 3 COMMON RESET COMMON RESET COMMON COMMON VSW VSW D INDICATOR (COM) E INDICATOR F INDICATOR G INDICATOR H INDICATOR K INDICATOR VSW VSW D INDICATOR (COM) E INDICATOR F INDICATOR G INDICATOR H INDICATOR K INDICATOR N/A N/A CONNECTOR PINOUT FOR LATCHING SP6T MULTI-THROW SWITCHES EXAMPLE INDICATOR TTL DECODERS & TTL PIN NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 CR-39S660-S CR-39S66C-S YES CR-39S660-TS CR-39S66C-TS CR-39S660-TDS CR-39S66C-TDS YES YES 9-PIN PORT 1 PORT 2 PORT 3 15-PIN PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 COMMON PORT 4 PORT 5 PORT 6 COMMON RESET RESET N/A D INDICATOR (COM) E INDICATOR F INDICATOR G INDICATOR H INDICATOR K INDICATOR L INDICATOR © 2013 TELEDYNE RELAYS 9-PIN TTL 1 TTL 2 TTL 3 TTL 4 TTL 5 TTL 6 COMMON RESET VSW N/A YES 9-PIN LOGIC 1 LOGIC 2 LOGIC 3 YES 15-PIN LOGIC 1 LOGIC 2 LOGIC 3 COMMON COMMON VSW D INDICATOR (COM) E INDICATOR F INDICATOR G INDICATOR H INDICATOR K INDICATOR L INDICATOR CONFIGURATION NOT AVAILABLE CONTACT FACTORY VSW N/A (800) 284-7007 • www.teledynecoax.com CCR-39S/CR-39S Page 3 CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch TRUTH TABLE Latching CCR-39SX3C-T Logic Input RF Path 1 2 3 R 1 0 0 0 1 0 0 0 1 Indicator Switches J1 J2 J3 Reset E 0 On Off 0 Off On 0 Off Off On F G Off Off Off Off C 0 0 0 C 0 Off 0 0 C TRUTH TABLE Latching CCR-39SX3C-TD Logic Input RF Path Indicator Switches 1 2 3 J1 J2 J3 Reset E F G 0 0 0 On Off Off Off C 0 0 1 0 0 Off On Off Off 0 C 0 0 1 0 Off Off On Off 0 0 C 0 1 1 Off Off Off Reset 0 0 0 1 1 1 0 0 0 COIL OFF TRUTH TABLE Latching CCR-39SX4C-T Logic Input 1 2 RF Path 3 4 R J1 J2 J3 Indicator Switches J4 Reset E F G H 1 0 0 0 0 On Off Off Off Off C 0 0 0 0 1 0 0 0 Off On Off Off Off 0 C 0 0 0 0 1 0 0 Off Off On Off Off 0 0 C 0 0 0 0 1 0 Off Off Off On Off 0 0 0 C TRUTH TABLE Latching CCR-39SX4C-TD Logic Input RF Path Indicator Switches 1 2 3 J1 J2 J3 J4 Reset E F G H 0 0 0 On Off Off Off Off C 0 0 0 1 0 0 Off On Off Off Off 0 C 0 0 0 1 0 Off Off On Off Off 0 0 C 0 1 1 0 Off Off Off On Off 0 0 0 C 0 1 1 Off Off Off Off Reset 1 1 1 CCR-39S/CR-39S Page 4 COIL OFF 0 0 0 0 0 0 0 0 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch TRUTH TABLE Latching CCR-39SX5C-T Logic Input RF Path Indicator Switches 1 2 3 4 5 R J1 J2 J3 J4 J5 Reset E F G H K 1 0 0 0 0 0 On Off Off Off Off Off C 0 0 0 0 0 1 0 0 0 0 Off On Off Off Off Off 0 C 0 0 0 0 0 1 0 0 0 Off Off On Off Off Off 0 0 C 0 0 0 0 0 1 0 0 Off Off Off On Off Off 0 0 0 C 0 0 0 0 0 1 0 Off Off Off Off On Off 0 0 0 0 C TRUTH TABLE Latching CCR-39SX5C-TD Logic Input RF Path Indicator Switches 1 2 3 J1 J2 J3 J4 J5 Reset E F G H K 0 0 0 On Off Off Off Off Off C 0 0 0 0 1 0 0 Off On Off Off Off Off 0 C 0 0 0 0 1 0 Off Off On Off Off Off 0 0 C 0 0 1 1 0 Off Off Off On Off Off 0 0 0 C 0 0 0 1 Off Off Off Off On Off 0 0 0 0 C 0 1 1 Off Off Off Off Off Reset 1 1 1 COIL OFF 0 0 0 0 0 0 0 0 0 0 TRUTH TABLE Latching CCR-39SX6C-T Logic Input 1 2 RF Path 3 4 5 6 R J1 J2 J3 Indicator Switches J4 J5 J6 Reset E F G H K L 1 0 0 0 0 0 0 On Off Off Off Off Off Off C 0 0 0 0 0 0 1 0 0 0 0 0 Off On Off Off Off Off Off 0 C 0 0 0 0 0 0 1 0 0 0 0 Off Off On Off Off Off Off 0 0 C 0 0 0 0 0 0 1 0 0 0 Off Off Off On Off Off Off 0 0 0 C 0 0 0 0 0 0 1 0 0 Off Off Off Off On Off Off 0 0 0 0 C 0 0 0 0 0 0 1 0 Off Off Off Off Off On Off 0 0 0 0 0 C TRUTH TABLE Latching CCR-39SX6C-TD Logic Input RF Path Indicator Switches 1 2 3 J1 J2 J3 J4 J5 J6 Reset E F G H K L 0 0 0 On Off Off Off Off Off Off C 0 0 0 0 0 1 0 0 Off On Off Off Off Off Off 0 C 0 0 0 0 0 1 0 Off Off On Off Off Off Off 0 0 C 0 0 0 1 1 0 Off Off Off On Off Off Off 0 0 0 C 0 0 0 0 1 Off Off Off Off On Off Off 0 0 0 0 C 0 1 0 1 Off Off Off Off Off On Off 0 0 0 0 0 C 0 1 1 Off Off Off Off Off Off Reset 1 1 1 © 2013 TELEDYNE RELAYS COIL OFF 0 0 0 0 0 0 0 0 0 0 0 0 (800) 284-7007 • www.teledynecoax.com CCR-39S/CR-39S Page 5 CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES Insertion Loss ( 4-8 GHz ) 0 0 -0.1 -0.1 Insertion Loss (dB) Insertion Loss (dB) Insertion Loss ( DC-4 GHz ) -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1 -1 0 1 2 3 4 4 5 Frequency (GHz) Insertion Loss ( 8-12 GHz ) 7 8 15 16 Insertion Loss ( 12-16 GHz ) 0 0 -0.1 -0.1 -0.2 -0.2 Insertion Loss (dB) Insertion Loss (dB) 6 Frequency (GHz) -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1 -1 8 9 10 11 12 12 13 Frequency (GHz) 14 Frequency (GHz) Insertion Loss ( 16-20 GHz ) Insertion Loss ( 20-22 GHz ) 0 0 -0.1 -0.2 -0.2 -0.3 Insertion Loss (dB) Insertion Loss(dB) -0.1 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1 16 17 18 19 Frequency (GHz) 20 -1 20 20.5 21 21.5 22 Frequency (GHz) 18GHZ+ ELITE MODEL ONLY RF NOTES CCR-39S/CR-39S Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES Isolation ( 4-8 GHz ) 0 0 -20 -20 -40 -40 Isolation (dB) Isolation (dB) Isolation ( DC-4 GHz ) -60 -80 -100 -120 -60 -80 -100 -120 -140 -140 0 1 2 3 4 4 5 Frequency (GHz) Isolation ( 8-12 GHz ) 7 8 15 16 Isolation ( 12-16 GHz ) 0 0 -20 -20 -40 -40 Isolation (dB) Isolation (dB) 6 Frequency (GHz) -60 -80 -100 -120 -60 -80 -100 -120 -140 -140 8 9 10 11 12 12 13 Frequency (GHz) 14 Frequency (GHz) Isolation ( 16-20 GHz ) Isolation ( 20-22 GHz ) 0 0 -20 -40 Isolation (dB) Isolation (dB) -20 -60 -80 -100 -40 -60 -80 -100 -120 -120 -140 16 17 18 Frequency (GHz) 19 20 -140 20 20.5 21 21.5 22 Frequency (GHz) 18GHZ+ ELITE MODEL ONLY RF NOTES © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-39S/CR-39S Page 7 CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES VSWR ( 4-8 GHz ) 2 2 1.9 1.9 1.8 1.8 1.7 1.7 1.6 1.6 VSWR VSWR VSWR ( DC-4 GHz ) 1.5 1.4 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.1 1 1 0 1 2 3 4 4 5 6 Frequency (GHz) VSWR ( 8-12 GHz ) 8 15 16 VSWR ( 12-16 GHz ) 2 2 1.9 1.9 1.8 1.8 1.7 1.7 1.6 1.6 VSWR VSWR 7 Frequency (GHz) 1.5 1.4 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.1 1 1 8 9 10 11 12 12 13 14 Frequency (GHz) Frequency (GHz) VSWR ( 16-20 GHz ) VSWR ( 20-22 GHz ) 2 2 1.9 1.9 1.8 1.7 1.7 1.6 1.6 VSWR VSWR 1.8 1.5 1.4 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.1 1 16 17 18 19 Frequency (GHz) RF NOTES CCR-39S/CR-39S Page 8 20 1 20 20.5 18GHZ+ ELITE MODEL ONLY SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 21 21.5 22 Frequency (GHz) © 2013 TELEDYNE COAX SWITCHES CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch TYPICAL POWER PERFORMANCE CURVE Power Handling vs. Frequency 3000 2000 Power (W) 1000 800 600 400 STAN DAR DS 300 MA 200 SW ITC HES 100 80 60 40 30 20 10 .1 .2 .3 .4 .6 .8 1 2 4 6 8 10 18 Frequency GHz Estimates based on the following reference conditions: • Ambient temperature of 40°C or less • Sea level operation • Load VSWR of 1.20:1 maximum • No high-power (hot) switching Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions. © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-39S/CR-39S Page 9 CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch GLOSSARY Actuator An actuator is the electromechanical mechanism that transfers the RF contacts from one position to another upon DC command. Arc Suppression Diode A diode is connected in parallel with the coil. This diode limits the “reverse EMF spike” generated when the coil de-energizes to 0.7 volts. The diode cathode is connected to the positive side of the coil and the anode is connected to the negative side. Date Code All switches are marked with either a unique serial number or a date code. Date codes are in accordance with MIL-STD-1285 Paragraph 5.2.5 and consist of four digits. The first two digits define the year and the last two digits define the week of the year (YYWW). Thus, 1032 identifies switches that passed through final inspection during the 32nd week of 2010. Indicator Indicators tell the system which position the switch is in. Other names for indicators are telemetry contacts or tellback circuit. Indicators are usually a set of internally mounted DC contacts linked to the actuator. They can be wired to digital input lines, status lights, or interlocks. Unless otherwise specified, the maximum indicator contact rating is 30 Vdc, 50 mA, or 1.5 Watts into a resistive load. Isolation Isolation is the measure of the power level at the output connector of an unconnected RF channel as referenced to the power at the input connector. It is specified in dB below the input power level. Multi-Throw Latching Switch A multi-throw switch is a switch with one input and three or more output ports. The CCR-39 can switch a microwave signal to any of 2,3,4,5 or 6 output from a single common input. Switching Time Switching time is the total interval beginning with the arrival of the leading edge of the command pulse at the switch DC input and ending with the completion of the switch transfer, including contact bounce. It consists of three parts: (1) inductive delay in the coil, (2) transfer time of the physical movement of the contacts, and (3) the bounce time of the RF contacts. TTL Switch Driver Option As a special option, switch drivers can be provided for both failsafe and latching switches, which are compatible with industry-standard low-power Schottky TTL circuits. TD-Option This option includes a decoder. The 3-bit parallel command is decoded to internally select the appropriate position. See the logic tables. The TD-Option increases the Vsw supply current demand by 50mA max at 28Vdc and +20°C. Performance Parameters vs Frequency Generally speaking, the RF performance of coaxial switches is frequency dependent. With increasing frequency, VSWR and insertion loss increase while isolation decreases. All data sheets specify these three parameters as “worst case” at the highest operating frequency. If the switch is to be used over a narrow frequency band, better performance can be achieved. Actuator Current vs Temperature The resistance of the actuator coil varies as a function of temperature. There is an inverse relationship between the operating temperature of the switch and the actuator drive current. For switches operating at 28 VDC, the approximate actuator drive current at temperature, T, can be calculated using the equation: IT = DUAL PULSE SWITCHING COMMAND CHARACTERISTICS: 1. APPLIES FOR SINGLE-POLE MULTI-THROW LATCHING SWITCH ONLY. 2. MUST APPLY RESET PULSE FIRST (BREAK-BEFORE-MAKE). 3. RESET AND SET DEFINITIONS RESET: OPEN ALL RF PATHS (POSITIONS). SET: CLOSE THE SELECTED RF PATH (POSITION). 4. COMMAND PULSE TIMING: RESET PULSE IT = Actuator current at temperature, T IA = Room temperature actuator current – see data sheet T = Temperature of interest in °C V VOLTAGE PULSE (SEE NOTE 5) O T1 T3 T2 T1 AND T2 = 30 mSEC MIN. T3 = 10 mSEC MIN. I2 CURRENT PULSE (SEE NOTE 6) ON SWITCHING TIME (MONITOR RF CONTACT): T4 AND T5 = 20 mSEC MAX OFF T4 T5 5. COMMAND SWITCHING VOLTAGE: V = 26-32 VDC PULSE 6. SWITCHING CURRENT: Magnetic Sensitivity An electro-mechanical switch can be sensitive to ferrous materials and external magnetic fields. Neighboring ferrous materials should be permitted no closer than 0.5 inches and adjacent external magnetic fields should be limited to a flux density of less than 5 Gauss. SPECIAL FEATURE Switching High-Power or Highly Sensitive Signals Ensure the most linear response with the best galvanically matched contact system in the industry. Extremely low passive intermodulation is standard on all of our switches. Carrier Frequency 1 Carrier Frequency 2 PIM 3rd Order Frequency PIM 5th Order Frequency 870 MHz 893 MHz 847 MHz 824 MHz SWITCHING CURRENT AT 28 VDC AND 20°C NO. OF POS. 3 POS. 4 POS. 5 POS. 6 POS. CCR-39S/CR-39S Page 10 RESET (I 1) 270 mA 360 mA 450 mA 540 mA SET (12) 90 mA 90 mA 90 mA 90 mA [1 + .00385 (T-20)] Where: SET PULSE I1 IA Multiple Positions 3rd Order Intermodulation 5th Order Intermodulation –96 dBm –115 dBm –139 dBc –158 dBc SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch LATCHING CCR-39S/CR-39S PART NUMBER LIST PART NO. * PART NO. PART NO. PART NO. 1 CCR-39SX3C 43 CCR-39SX30-TMS 85 CCR-39SX40-TDS 127 CCR-39SX50-TDM 2 CCR-39SX3C-D 44 CCR-39SX30-TS 86 CCR-39SX40-TM 128 CCR-39SX50-TDMS 3 CCR-39SX3C-DM 45 CCR-39SX4C 87 CCR-39SX40-TMS 129 CCR-39SX50-TDS 4 CCR-39SX3C-DR 46 CCR-39SX4C-D 88 CCR-39SX40-TS 130 CCR-39SX50-TM 5 CCR-39SX3C-DRM 47 CCR-39SX4C-DM 89 CCR-39SX5C 131 CCR-39SX50-TMS 6 CCR-39SX3C-DRS 48 CCR-39SX4C-DR 90 CCR-39SX5C-D 132 CCR-39SX50-TS 7 CCR-39SX3C-DS 49 CCR-39SX4C-DRM 91 CCR-39SX5C-DM 133 CCR-39SX6C 8 CCR-39SX3C-M 50 CCR-39SX4C-DRS 92 CCR-39SX5C-DR 134 CCR-39SX6C-D 9 CCR-39SX3C-MS 51 CCR-39SX4C-DS 93 CCR-39SX5C-DRM 135 CCR-39SX6C-DM 10 CCR-39SX3C-R 52 CCR-39SX4C-M 94 CCR-39SX5C-DRS 136 CCR-39SX6C-DR 11 CCR-39SX3C-RM 53 CCR-39SX4C-MS 95 CCR-39SX5C-DS 137 CCR-39SX6C-DRM 12 CCR-39SX3C-RMS 54 CCR-39SX4C-R 96 CCR-39SX5C-M 138 CCR-39SX6C-DRS 13 CCR-39SX3C-RS 55 CCR-39SX4C-RM 97 CCR-39SX5C-MS 139 CCR-39SX6C-DS 14 CCR-39SX3C-S 56 CCR-39SX4C-RMS 98 CCR-39SX5C-R 140 CCR-39SX6C-M 15 CCR-39SX3C-T 57 CCR-39SX4C-RS 99 CCR-39SX5C-RM 141 CCR-39SX6C-MS 16 CCR-39SX3C-TD 58 CCR-39SX4C-S 100 CCR-39SX5C-RMS 142 CCR-39SX6C-R 17 CCR-39SX3C-TDM 39 CCR-39SX4C-T 101 CCR-39SX5C-RS 143 CCR-39SX6C-RM 18 CCR-39SX3C-TDMS 60 CCR-39SX4C-TD 102 CCR-39SX5C-S 144 CCR-39SX6C-RMS 19 CCR-39SX3C-TDS 61 CCR-39SX4C-TDM 103 CCR-39SX5C-T 145 CCR-39SX6C-RS 20 CCR-39SX3C-TM 62 CCR-39SX4C-TDMS 104 CCR-39SX5C-TD 146 CCR-39SX6C-S 21 CCR-39SX3C-TMS 63 CCR-39SX4C-TDS 105 CCR-39SX5C-TDM 147 CCR-39SX6C-T 22 CCR-39SX3C-TS 64 CCR-39SX4C-TM 106 CCR-39SX5C-TDMS 148 CCR-39SX6C-TD 23 CCR-39SX30 65 CCR-39SX4C-TMS 107 CCR-39SX5C-TDS 149 CCR-39SX6C-TDM 24 CCR-39SX30-D 66 CCR-39SX4C-TS 108 CCR-39SX5C-TM 150 CCR-39SX6C-TDMS 25 CCR-39SX30-DM 67 CCR-39SX40 109 CCR-39SX5C-TMS 151 CCR-39SX6C-TDS 26 CCR-39SX30-DR 68 CCR-39SX40-D 110 CCR-39SX5C-TS 152 CCR-39SX6C-TM 27 CCR-39SX30-DRM 69 CCR-39SX40-DM 111 CCR-39SX50 153 CCR-39SX6C-TMS 28 CCR-39SX30-DRS 70 CCR-39SX40-DR 112 CCR-39SX50-D 154 CCR-39SX6C-TS 29 CCR-39SX30-DS 71 CCR-39SX40-DRM 113 CCR-39SX50-DM 155 CCR-39SX60 30 CCR-39SX30-M 72 CCR-39SX40-DRS 114 CCR-39SX50-DR 156 CCR-39SX60-D 31 CCR-39SX30-MS 73 CCR-39SX40-DS 115 CCR-39SX50-DRM 157 CCR-39SX60-DM 32 CCR-39SX30-R 74 CCR-39SX40-M 116 CCR-39SX50-DRS 158 CCR-39SX60-DR 33 CCR-39SX30-RM 75 CCR-39SX40-MS 117 CCR-39SX50-DS 139 CCR-39SX60-DRM 34 CCR-39SX30-RMS 76 CCR-39SX40-R 118 CCR-39SX50-M 160 CCR-39SX60-DRS 35 CCR-39SX30-RS 77 CCR-39SX40-RM 119 CCR-39SX50-MS 161 CCR-39SX60-DS 36 CCR-39SX30-S 78 CCR-39SX40-RMS 120 CCR-39SX50-R 162 CCR-39SX60-M 37 CCR-39SX30-T 79 CCR-39SX40-RS 121 CCR-39SX50-RM 163 CCR-39SX60-MS 38 CCR-39SX30-TD 80 CCR-39SX40-S 122 CCR-39SX50-RMS 164 CCR-39SX60-R 39 CCR-39SX30-TDM 81 CCR-39SX40-T 123 CCR-39SX50-RS 165 CCR-39SX60-RM 40 CCR-39SX30-TDMS 82 CCR-39SX40-TD 124 CCR-39SX50-S 166 CCR-39SX60-RMS 41 CCR-39SX30-TDS 83 CCR-39SX40-TDM 125 CCR-39SX50-T 167 CCR-39SX60-RS 42 CCR-39SX30-TM 84 CCR-39SX40-TDMS 126 CCR-39SX50-TD 168 CCR-39SX60-S X = 6 (28Vdc), 7 (15Vdc), 8 (12Vdc) and 9 (24Vdc) © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-39S/CR-39S Page 11 CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch LATCHING CCR-39S/CR-39S PART NUMBER LIST PART NO. * PART NO. PART NO. PART NO. 169 CCR-39SX60-T 211 CR-39SX30-RS 253 CR-39SX40-RM 295 CR-39SX50-MS 170 CCR-39SX60-TD 212 CR-39SX30-S 254 CR-39SX40-RMS 296 CR-39SX50-R 171 CCR-39SX60-TDM 213 CR-39SX30-T 255 CR-39SX40-RS 297 CR-39SX50-RM 172 CCR-39SX60-TDMS 214 CR-39SX30-TD 256 CR-39SX40-S 298 CR-39SX50-RMS 173 CCR-39SX60-TDS 215 CR-39SX30-TDM 257 CR-39SX40-T 299 CR-39SX50-RS 174 CCR-39SX60-TM 216 CR-39SX30-TDMS 258 CR-39SX40-TD 300 CR-39SX50-S 175 CCR-39SX60-TMS 217 CR-39SX30-TDS 239 CR-39SX40-TDM 301 CR-39SX50-T 176 CCR-39SX60-TS 218 CR-39SX30-TM 260 CR-39SX40-TDMS 302 CR-39SX50-TD 177 CR-39SX3C 219 CR-39SX30-TMS 261 CR-39SX40-TDS 303 CR-39SX50-TDM 178 CR-39SX3C-D 220 CR-39SX30-TS 262 CR-39SX40-TM 304 CR-39SX50-TDMS 179 CR-39SX3C-DM 221 CR-39SX4C 263 CR-39SX40-TMS 305 CR-39SX50-TDS 180 CR-39SX3C-DR 222 CR-39SX4C-D 264 CR-39SX40-TS 306 CR-39SX50-TM 181 CR-39SX3C-DRM 223 CR-39SX4C-DM 265 CR-39SX5C 307 CR-39SX50-TMS 182 CR-39SX3C-DRS 224 CR-39SX4C-DR 266 CR-39SX5C-D 308 CR-39SX50-TS 183 CR-39SX3C-DS 225 CR-39SX4C-DRM 267 CR-39SX5C-DM 309 CR-39SX6C 184 CR-39SX3C-M 226 CR-39SX4C-DRS 268 CR-39SX5C-DR 310 CR-39SX6C-D 185 CR-39SX3C-MS 227 CR-39SX4C-DS 269 CR-39SX5C-DRM 311 CR-39SX6C-DM 186 CR-39SX3C-R 228 CR-39SX4C-M 270 CR-39SX5C-DRS 312 CR-39SX6C-DR 187 CR-39SX3C-RM 229 CR-39SX4C-MS 271 CR-39SX5C-DS 313 CR-39SX6C-DRM 188 CR-39SX3C-RMS 230 CR-39SX4C-R 272 CR-39SX5C-M 314 CR-39SX6C-DRS 189 CR-39SX3C-RS 231 CR-39SX4C-RM 273 CR-39SX5C-MS 315 CR-39SX6C-DS 190 CR-39SX3C-S 232 CR-39SX4C-RMS 274 CR-39SX5C-R 316 CR-39SX6C-M 191 CR-39SX3C-T 233 CR-39SX4C-RS 275 CR-39SX5C-RM 317 CR-39SX6C-MS 192 CR-39SX3C-TD 234 CR-39SX4C-S 276 CR-39SX5C-RMS 318 CR-39SX6C-R 193 CR-39SX3C-TDM 235 CR-39SX4C-T 277 CR-39SX5C-RS 319 CR-39SX6C-RM 194 CR-39SX3C-TDMS 236 CR-39SX4C-TD 278 CR-39SX5C-S 320 CR-39SX6C-RMS 195 CR-39SX3C-TDS 237 CR-39SX4C-TDM 279 CR-39SX5C-T 321 CR-39SX6C-RS 196 CR-39SX3C-TM 238 CR-39SX4C-TDMS 280 CR-39SX5C-TD 322 CR-39SX6C-S 197 CR-39SX3C-TMS 239 CR-39SX4C-TDS 281 CR-39SX5C-TDM 323 CR-39SX6C-T 198 CR-39SX3C-TS 240 CR-39SX4C-TM 282 CR-39SX5C-TDMS 324 CR-39SX6C-TD 199 CR-39SX30 241 CR-39SX4C-TMS 283 CR-39SX5C-TDS 325 CR-39SX6C-TDM 200 CR-39SX30-D 242 CR-39SX4C-TS 284 CR-39SX5C-TM 326 CR-39SX6C-TDMS 201 CR-39SX30-DM 243 CR-39SX40 285 CR-39SX5C-TMS 327 CR-39SX6C-TDS 202 CR-39SX30-DR 244 CR-39SX40-D 286 CR-39SX5C-TS 328 CR-39SX6C-TM 203 CR-39SX30-DRM 245 CR-39SX40-DM 287 CR-39SX50 329 CR-39SX6C-TMS 204 CR-39SX30-DRS 246 CR-39SX40-DR 288 CR-39SX50-D 330 CR-39SX6C-TS 205 CR-39SX30-DS 247 CR-39SX40-DRM 289 CR-39SX50-DM 331 CR-39SX60 206 CR-39SX30-M 248 CR-39SX40-DRS 290 CR-39SX50-DR 332 CR-39SX60-D 207 CR-39SX30-MS 249 CR-39SX40-DS 291 CR-39SX50-DRM 333 CR-39SX60-DM 208 CR-39SX30-R 250 CR-39SX40-M 292 CR-39SX50-DRS 334 CR-39SX60-DR 209 CR-39SX30-RM 251 CR-39SX40-MS 293 CR-39SX50-DS 335 CR-39SX60-DRM 210 CR-39SX30-RMS 252 CR-39SX40-R 294 CR-39SX50-M 336 CR-39SX60-DRS X = 6 (28Vdc), 7 (15Vdc), 8 (12Vdc) and 9 (24Vdc) CCR-39S/CR-39S Page 12 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-39S\CR-39S\072013\Q3 Series CCR-39S/CR-39S COAX SWITCHES Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch LATCHING CCR-39S/CR-39S PART NUMBER LIST PART NO. * 337 CR-39SX60-DS 338 CR-39SX60-M 339 CR-39SX60-MS 340 CR-39SX60-R 341 CR-39SX60-RM 342 CR-39SX60-RMS 343 CR-39SX60-RS 344 CR-39SX60-S 345 CR-39SX60-T 346 CR-39SX60-TD 347 CR-39SX60-TDM 348 CR-39SX60-TDMS 349 CR-39SX60-TDS 350 CR-39SX60-TM 351 CR-39SX60-TMS 352 CR-39SX60-TS X = 6 (28Vdc), 7 (15Vdc), 8 (12Vdc) and 9 (24Vdc) © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-39S/CR-39S Page 13 CCR-39S\CR-39S\072013\Q3