ETC2 ATV212H075M3X Variable speed drive atv212 Datasheet

Product data sheet
Characteristics
ATV212H075M3X
variable speed drive ATV212 - 0.75kW - 1hp 240V - 3ph - wo EMC - IP21
Range of product
Altivar 212
Product or component
type
Variable speed drive
Device short name
ATV212
Product destination
Asynchronous motors
Product specific application
Pumps and fans in HVAC
Assembly style
With heat sink
Network number of
phases
3 phases
Motor power kW
0.75 kW
Motor power hp
1 hp
Power supply voltage
200...240 V (- 15...10 %)
Power supply voltage
limits
170...264 V
Supply frequency
50...60 Hz (- 5...5 %)
Network frequency
47.5...63 Hz
EMC filter
Without EMC filter
Line current
3.3 A for 200 V
2.7 A for 240 V
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Complementary
Apparent power
1.8 kVA for 240 V
Prospective line Isc
5 kA
Continuous output current
4.6 A at 230 V
Maximum transient current
5.1 A for 60 s
Speed drive output frequency
0.5...200 Hz
Nominal switching frequency
12 kHz
Switching frequency
12...16 kHz with derating factor
6...16 kHz adjustable
Speed range
1...10
Speed accuracy
+/- 10 % of nominal slip for 0.2 Tn to Tn torque variation
Torque accuracy
+/- 15 %
Transient overtorque
120 % of nominal motor torque, +/- 10 % for 60 s
Asynchronous motor control profile
Voltage/Frequency ratio, 2 points
Voltage/Frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/Frequency ratio - Energy Saving, quadratic U/f
Voltage/Frequency ratio, automatic IR compensation (U/f + automatic Uo)
Regulation loop
Adjustable PI regulator
Motor slip compensation
Adjustable
Automatic whatever the load
Not available in voltage/frequency ratio motor control
Local signalling
1 LED - red - DC bus energized
Output voltage
<= power supply voltage
Isolation
Electrical between power and control
Type of cable for external connection
UL 508 cable with UL Type 1 kit: 3 wire(s) - 40 °C, copper 75 °C / PVC
IEC cable without mounting kit: 1 wire(s) - 45 °C, copper 70 °C / PVC
IEC cable without mounting kit: 1 wire(s) - 45 °C, copper 90 °C / XLPE/EPR
Jun 15, 2015
1
Electrical connection
Terminal 6 mm² / AWG 10 (L1/R, L2/S, L3/T)
Terminal 2.5 mm² / AWG 14 (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Tightening torque
1.3 N.m - 11.5 lb.in (L1/R, L2/S, L3/T)
0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Supply
Internal supply: 24 V (21...27 V) DC - <= 200 A with overload and short-circuit
protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 % <= 10 A with overload and short-circuit protection
Analogue input number
2
Analogue input type
Configurable voltage: (VIB) 0...10 V DC - 24 V max - 30000 Ohm - resolution: 10
bits
Switch-configurable current: (VIA) 0...20 mA - 250 Ohm - resolution: 10 bits
Switch-configurable voltage: (VIA) 0...10 V DC - 24 V max - 30000 Ohm - resolution: 10 bits
Configurable PTC probe: (VIB) 0...6 probes - 1500 Ohm
Sampling duration
22 ms +/- 0.5 ms (VIB) - analog input(s)
3.5 ms +/- 0.5 ms (VIA) - analog input(s)
2 ms +/- 0.5 ms (RES) - discrete input(s)
2 ms +/- 0.5 ms (R) - discrete input(s)
2 ms +/- 0.5 ms (F) - discrete input(s)
Response time
7 ms +/- 0.5 ms (RY, RC) - discrete output(s)
7 ms +/- 0.5 ms (FLB, FLC) - discrete output(s)
7 ms +/- 0.5 ms (FLA, FLC) - discrete output(s)
2 ms +/- 0.5 ms (FM) - analog output(s)
Accuracy
+/- 1 % (FM) for a temperature variation 60 °C
+/- 0.6 % (VIB) for a temperature variation 60 °C
+/- 0.6 % (VIA) for a temperature variation 60 °C
Linearity error
+/- 0.2 % for output (FM)
+/- 0.15 % of maximum value for input (VIB)
+/- 0.15 % of maximum value for input (VIA)
Analogue output number
1
Analogue output type
Switch-configurable current: (FM) 0...20 mA - 970 Ohm - resolution: 10 bits
Switch-configurable voltage: (FM) 0...10 V DC - 7620 Ohm - resolution: 10 bits
Discrete output number
2
Discrete output type
Configurable relay logic: (RY, RC) NO - 100000 cycles
Configurable relay logic: (FLB, FLC) NC - 100000 cycles
Configurable relay logic: (FLA, FLC) NO - 100000 cycles
Minimum switching current
3 mA at 24 V DC (configurable relay logic)
Maximum switching current
2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
Discrete input type
Programmable (RES) 24 V DC, with level 1 PLC - 4700 Ohm
Programmable (R) 24 V DC, with level 1 PLC - 4700 Ohm
Programmable (F) 24 V DC, with level 1 PLC - 4700 Ohm
Discrete input logic
Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
Acceleration and deceleration ramps
Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
Braking to standstill
By DC injection
Protection type
With PTC probes for motor
Motor phase break for motor
Thermal protection for motor
Against input phase loss for drive
Line supply undervoltage for drive
Line supply overvoltage and undervoltage for drive
Against exceeding limit speed for drive
Break on the control circuit for drive
Overvoltages on the DC bus for drive
Overcurrent between output phases and earth for drive
Input phase breaks for drive
Short-circuit between motor phases for drive
Thermal power stage for drive
Overheating protection for drive
Dielectric strength
4230 V DC between control and power terminals
2830 V DC between earth and power terminals
Insulation resistance
>= 1 MOhm at 500 V DC for 1 minute
Frequency resolution
0.024/50 Hz for analog input
0.1 Hz for display unit
2
Communication port protocol
APOGEE FLN
BACnet
LonWorks
METASYS N2
Modbus
Connector type
1 RJ45
1 open style
Physical interface
2-wire RS 485
Transmission frame
RTU
Transmission rate
9600 bps or 19200 bps
Data format
8 bits, 1 stop, odd even or no configurable parity
Type of polarization
No impedance
Number of addresses
1...247
Communication service
Monitoring inhibitable
Read device identification (43)
Read holding registers (03) 2 words maximum
Time out setting from 0.1 to 100 s
Write multiple registers (16) 2 words maximum
Write single register (06)
Option card
Communication card for LonWorks
Operating position
Vertical +/- 10 degree
Width
107 mm
Height
143 mm
Depth
150 mm
Product weight
1.8 kg
Power dissipation in W
63 W
Fan flow rate
22 m3/h
Environment
Electromagnetic compatibility
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Radiated radio-frequency electromagnetic field immunity test level 3 conforming
to IEC 61000-4-3
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Pollution degree
2 IEC 61800-5-1
IP degree of protection
IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529
IP20 on upper part without blanking plate on cover conforming to EN/IEC
61800-5-1
IP41 on upper part conforming to EN/IEC 60529
IP41 on upper part conforming to EN/IEC 61800-5-1
IP21 conforming to EN/IEC 60529
IP21 conforming to EN/IEC 61800-5-1
Vibration resistance
1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-8
1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Environmental characteristic
Classes 3S2 conforming to IEC 60721-3-3
Classes 3C1 conforming to IEC 60721-3-3
Noise level
51 dB conforming to 86/188/EEC
Operating altitude
1000...3000 m (limited to 2000 m for the Corner Grounded distribution network)
with current derating 1 % per 100 m
<= 1000 m without derating
Relative humidity
5...95 % without dripping water conforming to IEC 60068-2-3
5...95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation
> 40...50 °C with derating factor
-10...40 °C without derating
Ambient air temperature for storage
-25...70 °C
3
Standards
EN 61800-3
EN 61800-3 environments 1 category C1
EN 61800-3 environments 1 category C2
EN 61800-3 environments 1 category C3
EN 61800-3 environments 2 category C1
EN 61800-3 environments 2 category C2
EN 61800-3 environments 2 category C3
EN 61800-5-1
IEC 61800-3
IEC 61800-3 environments 1 category C1
IEC 61800-3 environments 1 category C2
IEC 61800-3 environments 1 category C3
IEC 61800-3 environments 2 category C1
IEC 61800-3 environments 2 category C2
IEC 61800-3 environments 2 category C3
IEC 61800-5-1
UL Type 1
Product certifications
CSA
C-Tick
NOM 117
UL
Marking
CE
Offer Sustainability
Sustainable offer status
RoHS
REACh
Green Premium product
Compliant - since 1101 -
Schneider Electric declaration of conformity
Reference contains SVHC above the threshold -
Product environmental profile
Available
Download Product Environmental
Product end of life instructions
Available
Download End Of Life Manual
4
go to CaP for more details
ATV212H075M3X
Product data sheet
Dimensions Drawings
Dimensions
Dimensions in mm
ATV212H
a
b
G
H
J
K
Ø
075M3X...U22M3X
107
143
93
121.5
5
16.5
2 x Ø5
142
184
126
157
6.5
20.5
4 x Ø5
ATV212H
a
b
G
H
J
K
Ø
075M3X...U22M3X
4.21
5.63
3.66
4.78
0.20
0.65
2 x Ø0.20
5.59
7.24
4.96
6.18
0.26
0.81
4 x Ø0.20
075N4...U22N4
U30M3X, U40M3X
U30N4...U55N4
Dimensions in in.
075N4...U22N4
U30M3X, U40M3X
U30N4...U55N4
Plate for EMC mounting (supplied with the drive)
(1)
2 x M5 screws
Dimensions in mm
ATV212H
b1
c
075M3X...U22M3X
49
67.3
48
88.8
ATV212H
b1
c
075M3X...U22M3X
1.93
2.65
1.89
3.50
075N4...U22N4
U30M3X, U40M3X
U30N4...U55N4
Dimensions in in.
075N4...U22N4
U30M3X, U40M3X
U30N4...U55N4
5
Product data sheet
Mounting and Clearance
ATV212H075M3X
Mounting Recommendations
Clearance
Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate
accessories.
Install the unit vertically:
● Do not place it close to heating elements.
● Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit.
Mounting Types
Type A mounting
Type B mounting
Type C mounting
By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective
blanking cover may vary according to the drive model, see opposite.
Specific Recommendations for Mounting in an Enclosure
To help ensure proper air circulation in the drive:
● Fit ventilation grilles.
● Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must
provide a flow rate at least equal to that of the drive fans (refer to the product characteristics).
● Use special filters with UL Type 12/IP54 protection.
● Remove the blanking cover from the top of the drive.
6
Sealed Metal Enclosure (IP54 Degree of Protection)
The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high
humidity with risk of condensation and dripping water, splashing liquid, etc.This enables the drive to be used in an enclosure where the
maximum internal temperature reaches 50°C.
7
Product data sheet
Connections and Schema
ATV212H075M3X
Recommended Wiring Diagram
3-Phase Power Supply
A1: ATV 212 drive
KM1: Contactor
Q1: Circuit breaker
Q2: GV2 L rated at twice the nominal primary current of T1
Q3: GB2CB05
S1, XB4 B or XB5 A pushbuttons
S2:
T1: 100 VA transformer 220 V secondary
(1) Fault relay contacts for remote signalling of the drive status
(2) Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink)
(3) Reference potentiometer SZ1RV1202
All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on the
same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc.
Switches (Factory Settings)
Voltage/current selection for analog I/O (VIA and VIB)
Voltage/current selection for analog I/O (FM)
Selection of logic type
(1)
(2)
negative logic
positive logic
Other Possible Wiring Diagrams
8
Logic Inputs According to the Position of the Logic Type Switch
“Source” position
“Sink” position
“PLC” position with PLC transistor outputs
(1)
PLC
(1)
PLC
2-wire control
F:
R:
(2)
Forward
Preset speed
ATV 212 control terminals
3-wire control
F:
Forward
R:
Stop
RES: Reverse
(2) ATV 212 control terminals
PTC probe
(2)
(3)
ATV 212 control terminals
Motor
Analog Inputs
Voltage analog inputs
External +10 V
(2)
(4)
ATV 212 control terminals
Speed reference potentiometer 2.2 to 10 kΩ
(2)
ATV 212 control terminals
9
Analog input configured for current: 0-20 mA, 4-20 mA, X-Y mA
(2)
(5)
ATV 212 control terminals
Source 0-20 mA, 4-20 mA, X-Y mA
Analog input VIA configured as positive logic input (“Source” position)
(2)
ATV 212 control terminals
Analog input VIA configured as negative logic input (“Sink” position)
(2)
10
ATV 212 control terminals
Product data sheet
Performance Curves
ATV212H075M3X
Derating Curves
The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C).
For intermediate temperatures (45°C for example), interpolate between 2 curves.
X
Switching frequency
11