Click on Series name for product info on aimtec.com Series AMEL5-CJZ 5 Watt | AC-DC / DC-DC Converter Picture coming soon FEATURES: • • • • • • • • I/O Isolation 4000VAC Operating Temp: -25 °C to +70 °C Input: 85-264VAC, 47-63Hz, or 100-370VDC Over current, Over Voltage Protection High efficiency up to 83% No load consumption ≤ 0.3W Ultra small package Short Circuit Protection Models Single output Model AMEL5-3.3SCJZ AMEL5-5SCJZ AMEL5-12SCJZ AMEL5-15SCJZ AMEL5-24SCJZ Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 100-370 100-370 100-370 100-370 100-370 3.3 5 12 15 24 Output Current max (A) Maximum capacitive Load (µF) Efficiency (%) 4000 4000 820 820 330 74 78 80 82 83 Maximum Units 1.25 1 0.42 0.333 0.23 230 VAC Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Input Dissipation (No Load) Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 150 70 10 20 0.2 Recommended slow blow type No load (110/230VAC) mA mA A A mA A W 1.5 0.3 Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise * Hold-up time (minimum) Conditions Typical 3.3V output Others ±3 ±2 ±0.5 ±1 60 50 12 80 10-100% load 20MHz Bandwidth, 3.3 / 5V models 20MHz Bandwidth, others 115VAC 230VAC Maximum Units % % % 120 100 mV p-p ms *Ripple and Noise are measured at 20MHz bandwidth by using the referenced Application circuit. Isolation Specifications Parameters Tested I/O voltage Isolation Resistance Conditions Typical 60 sec 4000 >1000 Conditions Typical Rated Units VAC MΩ General Specifications Parameters Switching frequency Protection class Over Current protection Over voltage protection Short circuit protection Operating temperature Storage temperature www.aimtec.com F 052e R8 Auto recovery See derating curve 140 Class II ≥110 Zener diode clamp Continuous, hiccup, Auto recovery -25 to 70°C -25 to +105 Tel: +1 514 620 2722 1 of 3 Maximum Units KHz % of Iout °C °C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-CJZ 5 Watt | AC-DC / DC-DC Converter General Specifications (continued) Parameters Conditions Typical Maximum Units Maximum Case temperature 100 °C Temperature coefficient 0.02 % /°C Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 31 g Dimensions (L x W x H) 2.0 x 1.0 x 0.6 inches 50.80 x 25.40 x 15.16mm o MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals cULus, CE pending Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC/EN/UL 60950-1 EN55022, class B IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3, Level 4 with recommended EMC circuit IEC 61000-4-5 Level 3, Level 4 with recommended EMC circuit IEC 61000-4-6 Level 3 IEC 61000-4-8 Level 3 IEC 61000-4-11, Class 2 Dimensions 50.80 (2.00) 45.72 (1.80) 1 Case Temperature Measurement point 3 1 TOP VIEW 0.40 (10.16) 25.40 20.32 (1.00) (0.80) TOP VIEW 4 + 2 2 15.16 (0.60) 6.00 (0.24) 4 5 Ø 1.5 (Ø 0.06) Ø 0.04 (1.00) 3 DIV: 5.08 (0.2) Dimensions: inch (mm) Case Tolerance:± 0.50 (0.02) Pin Pitch Tolerance: ± 0.10 (0.004) Pin Out Specifications Pin Single 1 2 3 4 AC Input (N) AC Input (L) +V Output -V Output www.aimtec.com F 052e R8 Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-CJZ 5 Watt | AC-DC / DC-DC Converter Derating Free Air Convection at 25°C Free Air Convection 100 80 Output Power (%) 100 Safe Operating Area 70 Input 110-240VAC or 140-340VDC 60 50 40 20 80 Safe Operating Area 60 50 40 20 0 0 - 25 -20 -10 70 55 0 20 40 60 85 110 (100) (140) 100 80 Ambient Temperature º C 240 (340) 264 (370) Input Voltage VAC (VDC) Typical application circuit AC L FUSE 1A/250V Single Output NTC 4 AC L MOV S14K350 AC AC N + Vout DC AC N C1 C2 1µF/50V + 3 - Vout EMC recommended circuit AC L FUSE 1A/250V MOV S14K350 LDM 4.7µH/2A Single Output LCM 2.2mH NTC CY1 1nF/ 400VAC CX 0.1µF/ 275VAC CY2 1nF/ 400VAC AC N +Vout +Vout AC N AC DC AC L - Vout C1 C2 1µF/50V + - Vout GND Model 3.3 & 5 Vout 9, 12 & 15 Vout 24 Vout C2 220 µF / 35V 120 µF / 35V 47 µF / 35V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8 Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only