Click on Series name for product info on aimtec.com Series AME10-BJZ Preliminary 10 Watt | AC-DC / DC-DC Converter FEATURES: Picture coming soon • • • • Input: 90-528VAC, 47-63Hz, or 100-745VDC Operating Temp: -40°C to +70°C Over current Protection I/O Isolation of 4000VAC • • • • Class II power supply Over Voltage Protection Up to 80% efficiency Short Circuit Protection Models Single output Model AME10-3.3SBJZ AME10-5SBJZ AME10-9SBJZ AME10-12SBJZ AME10-15SBJZ AME10-24SBJZ Input Voltage (VAC/Hz) Input Voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum capacitive load (µF) 90-528/47-63 90-528/47-63 90-528/47-63 90-528/47-63 90-528/47-63 90-528/47-63 100-745 100-745 100-745 100-745 100-745 100-745 6.6 10 10 10 10 10 3.3 5 9 12 15 24 2 2 1.1 0.9 0.7 0.45 15,000 15,000 10,000 5,000 3,000 1,000 Efficiency (%) 230 VAC 70 74 76 78 78 80 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse No load consumption Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 230VAC/50Hz Recommended slow blow type Maximum Units 400 230 0.75 mA mA A A mA A W Typical Maximum Units ±2 ±0.5 ±1 ±3 % % % mV p-p ms 25 40 3.15 0.25 Output Specifications Parameters Conditions Voltage accuracy Line regulation (LL-HL) Load regulation 0-100% load Ripple & Noise* 20MHz bandwidth Hold up time 230 VAC *Tested as per the referenced Application Circuit. 150 35 Isolation Specifications Parameters Tested I/O voltage Isolation resistance Conditions Typical Rated Units 4000 VAC MΩ Maximum Units Input to Output, 60 sec >1000 General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity www.aimtec.com F 052e R8.A Conditions Typical 65 See derating curve KHz % of Iout 130 - 400 Zener Diode Clamp Continuous, Hiccup, Auto recovery -40 to +70 100 -40 to +85 ±0.02 Free air convection Non condensing Tel: +1 514 620 2722 1 of 3 95 °C °C °C % / °C % RH Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME10-BJZ Preliminary 10 Watt | AC-DC / DC-DC Converter Case material Weight Dimensions (L x W x H) MTBF Plastic (flammability to UL 94V-0) 120 62.0 x 45.0 x 30.0 mm (2.44 x 1.77 x 1.18 inches) > 300 000 hrs (MIL-HDBK -217F, t=+25oC)/ Full Load g NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. Safety Specifications Parameters Information Technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Standards Electrical Fast Transient/Burst Immunity Surge Immunity* RF, Conducted Disturbance Immunity Voltage dips, Short Interruptions Immunity * For higher values, external circuit would be required. Designed to meet IEC/EN/UL 62368-1 EN55032, class B IEC 61000-4-2: Contact ±6KV/Air ±8KV, Criteria B IEC 61000-4-3: 10V/m, Criteria A IEC 61000-4-4: ±4KV, Criteria B IEC 61000-4-5: line to line: ±2KV, Criteria B IEC 61000-4-6: 10Vrms, Criteria A IEC 61000-4-11: 0-70%, Criteria B Typical Application circuit Single Output FUSE 3.15A/300V + Vout AC L AC L MOV S20K625 AC N AC + Vout TVS + DC C2 C1 1µF/50V AC N - Vout Vout C2 TVS 3.3 & 5V 9V 12V 15 & 24V 330 µF/50V 7A 12A 20A 30A * Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase. Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase, 240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase). 12.50 (0.49) AC Input (N) or (L1) AC Input (L) or (L2) - V output + V output 5.00 (0.20) 2 1 Bottom View F 052e R8.A 3 1 Top View 3 4 2 54.00 (2.13) 4.00 (0.16) DIV: 10.00 (0.40) Ø 1.50 (Ø 0.06) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) 1.00 (0.04) www.aimtec.com 4 20.00 (0.79) Single 1* 2* 3 4 Tel: +1 514 620 2722 2 of 3 6.00 (0.24) Pin 62.00 (2.44) 45.00 (1.77) 17.50 (0.69) Pin Out Specifications Dimensions 30.00 (1.18) 220 µF/50V - Vout Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME10-BJZ Preliminary 10 Watt | AC-DC / DC-DC Converter Derating Free Air Convection Free Air Convection at 25°C 100 80 70 Output Power (%) Output Power (%) 100 Safe Operating Area 60 55 40 60 Safe Operating Area 40 20 20 0 - 40 80 - 20 -10 0 20 40 55 70 80 60 100 0 90 110 (100) (155) 480 (675) 528 (745) Input Voltage VAC (VDC) Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.A Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only