AIMTEC AME10-5SBJZ 10 watt | ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AME10-BJZ
Preliminary
10 Watt | AC-DC / DC-DC Converter
FEATURES:
Picture coming soon
•
•
•
•
Input: 90-528VAC, 47-63Hz, or 100-745VDC
Operating Temp: -40°C to +70°C
Over current Protection
I/O Isolation of 4000VAC
•
•
•
•
Class II power supply
Over Voltage Protection
Up to 80% efficiency
Short Circuit Protection
Models
Single output
Model
AME10-3.3SBJZ
AME10-5SBJZ
AME10-9SBJZ
AME10-12SBJZ
AME10-15SBJZ
AME10-24SBJZ
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max
Output
wattage
(W)
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive load
(µF)
90-528/47-63
90-528/47-63
90-528/47-63
90-528/47-63
90-528/47-63
90-528/47-63
100-745
100-745
100-745
100-745
100-745
100-745
6.6
10
10
10
10
10
3.3
5
9
12
15
24
2
2
1.1
0.9
0.7
0.45
15,000
15,000
10,000
5,000
3,000
1,000
Efficiency
(%)
230
VAC
70
74
76
78
78
80
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
No load consumption
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC
230VAC/50Hz
Recommended slow blow type
Maximum
Units
400
230
0.75
mA
mA
A
A
mA
A
W
Typical
Maximum
Units
±2
±0.5
±1
±3
%
%
%
mV p-p
ms
25
40

3.15
0.25
Output Specifications
Parameters
Conditions
Voltage accuracy
Line regulation
(LL-HL)
Load regulation
0-100% load
Ripple & Noise*
20MHz bandwidth
Hold up time
230 VAC
*Tested as per the referenced Application Circuit.
150
35
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
Typical
Rated
Units
4000
VAC
MΩ
Maximum
Units
Input to Output, 60 sec
>1000
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
www.aimtec.com
F 052e R8.A
Conditions
Typical
65
See derating curve
KHz
% of Iout
130 - 400
Zener Diode Clamp
Continuous, Hiccup, Auto recovery
-40 to +70
100
-40 to +85
±0.02
Free air convection
Non condensing
Tel: +1 514 620 2722
1 of 3
95
°C
°C
°C
% / °C
% RH
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME10-BJZ
Preliminary
10 Watt | AC-DC / DC-DC Converter
Case material
Weight
Dimensions (L x W x H)
MTBF
Plastic (flammability to UL 94V-0)
120
62.0 x 45.0 x 30.0 mm (2.44 x 1.77 x 1.18 inches)
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)/ Full Load
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage
(115/230VAC) and at rated output load unless otherwise specified.
Safety Specifications
Parameters
Information Technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Standards
Electrical Fast Transient/Burst Immunity
Surge Immunity*
RF, Conducted Disturbance Immunity
Voltage dips, Short Interruptions Immunity
* For higher values, external circuit would be required.
Designed to meet IEC/EN/UL 62368-1
EN55032, class B
IEC 61000-4-2: Contact ±6KV/Air ±8KV, Criteria B
IEC 61000-4-3: 10V/m, Criteria A
IEC 61000-4-4: ±4KV, Criteria B
IEC 61000-4-5: line to line: ±2KV, Criteria B
IEC 61000-4-6: 10Vrms, Criteria A
IEC 61000-4-11: 0-70%, Criteria B
Typical Application circuit
Single Output
FUSE
3.15A/300V
+ Vout
AC L
AC L
MOV
S20K625
AC N
AC
+ Vout
TVS
+
DC
C2
C1
1µF/50V
AC N
- Vout
Vout
C2
TVS
3.3 & 5V
9V
12V
15 & 24V
330 µF/50V
7A
12A
20A
30A
* Note: Input Pins 1 and 2 can be “N” and "L"
respectively when the input voltage is supplied
from a single phase.
Input Pins 1 and 2 can be “L1” and "L2" respectively
when the input voltage is supplied from 3 phase
line to line voltage 208-480Vac
(208 Y/ 120V 3-phase, 240 Y/ 120V 3-phase,
400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase).
12.50
(0.49)
AC Input (N) or (L1)
AC Input (L) or (L2)
- V output
+ V output
5.00
(0.20)
2
1
Bottom
View
F 052e R8.A
3
1
Top View
3
4
2
54.00
(2.13)
4.00
(0.16)
DIV: 10.00 (0.40)
Ø 1.50 (Ø 0.06)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)
1.00
(0.04)
www.aimtec.com
4
20.00
(0.79)
Single
1*
2*
3
4
Tel: +1 514 620 2722
2 of 3
6.00
(0.24)
Pin
62.00
(2.44)
45.00
(1.77)
17.50
(0.69)
Pin Out Specifications
Dimensions
30.00
(1.18)
220 µF/50V
- Vout
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME10-BJZ
Preliminary
10 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection
Free Air Convection at 25°C
100
80
70
Output Power (%)
Output Power (%)
100
Safe Operating Area
60
55
40
60
Safe Operating Area
40
20
20
0
- 40
80
- 20 -10 0
20
40
55
70 80
60
100
0
90
110
(100) (155)
480
(675)
528
(745)
Input Voltage VAC (VDC)
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available
at www.aimtec.com.
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Similar pages