Double Balanced Mixer Model MO4xxN Octave Band RF 4.0 to 8.0 GHz Electrical Specifications : (1) Parameter SSB Conversion loss: (2) (3) RF (MHz) 4.0-8.0 4.0-8.0 4.0-8.0 Isolation LO to RF: LO to IF: RF to IF: Input 1 dB Compression Point: LO (MHz) 3.5-8.5 3.5-8.5 3.5-8.5 Model MO4xxN Specifications Conditions IF (MHz) DC-500 DC-1500 DC-2000 3.5-8.5 3.5-8.5 Min 25 dB 15 dB 4.0-8.0 4.0-8.0 3.5-8.5 DC-2000 Input Third Order Intercept Point: 4.0-8.0 3.5-8.5 DC-2000 LO Power: (4) 4.0-8.0 3.5-8.5 DC-2000 Notes: 1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system from -55˚C to +100˚C with the nominal LO power. Specifications indicated as typical are not guaranteed. 2. Noise figure is typically within ±0.5 dB of conversion loss for IF frequencies greater than 10 MHz. 3. Conversion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C. 4. Usable LO drives are up to 2 dB below and 3 dB above nominal. Outline: N MO4xxN Typical 5.5 dB 6.0 dB 6.7 dB 33 dB 22 dB 22 dB +1 dBm +4 dBm +8 dBm +12 dBm +11 dBm +14 dBm +18 dBm +22 dBm +7 dBm +10 dBm +14 dBm +19 dBm Max 7.0 dB 8.5 dB 9.5 dB LO Power 3 = +7 dBm 4 = +10 dBm 6 = +14 dBm 7 = +19 dBm MO43 MO44 MO46 MO47 MO43 MO44 MO46 MO47 MO43 MO44 MO46 MO47 Drop-In Module or With SMA(F) Connectors M = Module P = With Connectors Typical Performance at 25˚C SPECTRUM All dimensions are in inches and [mm]. Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, FL 32905 · PH (888) 553-7531 · Fax (888) 553-7532 www.SpectrumMicrowave.com Spectrum Microwave (Europe) · 2707 Black Lake Place · Philadelphia, PA 19154 · PH (215) 464-4000 · Fax (215) 464-4001