Datasheet Serial EEPROM Series Standard EEPROM WLCSP EEPROM BRCG064GWZ-3 General Description BRCG064GWZ-3 is a 64Kbit serial EEPROM of I2C BUS Interface Method Packages W(Typ) x D(Typ) x H(Max) Features 2 Completely Conforming to the World Standard I C BUS. All Controls Available by 2 Ports of Serial Clock (SCL) and serial data (SDA) Other Devices than EEPROM can be Connected to the Same Port, Saving Microcontroller Port 1.6V to 5.5V Single Power Source Operation Most Suitable for Battery Use 1.6V to 5.5V Wide Limit of Operating Voltage, Possible FAST MODE 400KHz Operation Up to 32 Byte in Page Write Mode Bit Format 8K x 8 Self-timed Programming Cycle Low Current Consumption Prevention of Write Mistake ¾ Write (Write Protect) Function Added ¾ Prevention of write mistake at low voltage More than 1 Million Write Cycles More than 40 Years Data Retention Noise Filter Built in SCL / SDA Terminal Initial Delivery State FFh ○Product structure:Silicon monolithic integrated circuit www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・14・001 UCSP35L1 1.50mm x1.00mm x 0.36mm ○This product has no designed protection against radioactive rays 1/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Absolute Maximum Ratings (Ta=25°C) Parameter Symbol Rating Unit Supply Voltage VCC -0.3 to +6.5 V Power Dissipation Pd 0.22(UCSP35L1) W Storage Temperature Tstg -65 to +125 °C Operating Temperature Topr -40 to +85 °C - -0.3 to Vcc+1.0 V Tjmax 150 °C Input Voltage/ Output Voltage Junction Temperature Remark Derate by 2.2mW/°C when operating above Ta=25°C The Max value of Input Voltage/Output Voltage is not over 6.5V. When the pulse width is 50ns or less, the Min value of Input Voltage/Output Voltage is not below 1.0V. Junction temperature at the storage condition Caution: Operating the IC over the absolute maximum ratings may damage the IC. The damage can either be a short circuit between pins or an open circuit between pins and the internal circuitry. Therefore, it is important to consider circuit protection measures, such as adding a fuse, in case the IC is operated over the absolute maximum ratings. Memory Cell Characteristics (Ta=25°C, Vcc=1.6V to 5.5V) Limit Parameter Write Cycles Unit (Note1) Data Retention (Note1) Min Typ Max 1,000,000 - - Times 40 - - Years (Note1) Not 100% TESTED Recommended Operating Ratings Parameter Symbol Rating Power Source Voltage Vcc 1.6 to 5.5 Input Voltage VIN 0 to Vcc Unit V DC Characteristics (Unless otherwise specified, Ta=-40°C to +85°C, Vcc=1.6V to 5.5V) Parameter Symbol Limit Min Typ Max Unit Conditions Input High Voltage1 VIH1 0.7Vcc - Vcc+1.0 V 1.7V≤Vcc≤5.5V Input Low Voltage1 VIL1 -0.3 (Note2) - +0.3Vcc V 1.7V≤Vcc≤5.5V Input High Voltage2 VIH2 0.8Vcc Input Low Voltage2 VIL2 Output Low Voltage1 VOL1 Output Low Voltage2 -0.3 - Vcc+1.0 V 1.6V≤Vcc<1.7V (Note2) - +0.2Vcc V 1.6V≤Vcc<1.7V - - 0.4 V IOL=3.0mA, 2.5V≤Vcc≤5.5V (SDA) VOL2 - - 0.2 V IOL=0.7mA, 1.6V≤Vcc<2.5V (SDA) Input Leakage Current ILI -1 - +1 µA VIN=0 to Vcc Output Leakage Current ILO -1 - +1 µA VOUT=0 to Vcc (SDA) Supply Current (Write) ICC1 - - 2.0 mA Supply Current (Read) ICC2 - - 0.5 mA Standby Current ISB - - 2.0 µA Vcc=5.5V, fSCL=400kHz, tWR=5ms, Byte Write, Page Write Vcc=5.5V, fSCL=400kHz Random Read, current Read, Sequential Read WP=GND or Vcc Vcc=5.5V, SDA・SCL=Vcc WP=GND or Vcc, TEST=GND or Vcc (Note2) When the pulse width is 50ns or less, it is -1.0V. www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 2/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 AC Characteristics (Unless otherwise specified, Ta=-40°C to +85°C, Vcc=1.6V to 5.5V) Parameter Limit Symbol Min Typ Max Unit Clock Frequency Data Clock High Period fSCL - - 400 kHz tHIGH 0.6 - - μs Data Clock Low Period tLOW 1.2 - - µs SDA,SCL(INPUT) Rise Time (Note1) SDA,SCL (INPUT)Fall Time (Note1) tR - - 1.0 µs tF1 - - 1.0 µs SDA(OUTPUT)Fall Time (Note1) tF2 - - 0.3 µs tHD:STA 0.6 - - µs Start Condition Setup Time tSU:STA 0.6 - - µs Input Data Hold Time tHD:DAT 0 - - ns Input Data Setup Time Start Condition Hold Time tSU:DAT 100 - - ns Output Data Delay Time tPD 0.1 - 0.9 µs Output Data Hold Time tDH 0.1 - - µs Stop Condition Setup Time tSU:STO 0.6 - - µs Bus Free Time tBUF 1.2 - - µs Write Cycle Time tWR - - 5 ms tI - - 0.1 µs tHD:WP 1.0 - - µs Noise Spike Width (SDA and SCL) WP Hold Time WP Setup Time tSU:WP 0.1 - - µs WP High Period tHIGH:WP 1.0 - - µs (Note1) Not 100% TESTED. Condition Input Data Level: VIL=0.2×Vcc VIH=0.8×Vcc Input Data Timing Reference Level: 0.3×Vcc/0.7×Vcc Output Data Timing Reference Level: 0.3×Vcc/0.7×Vcc Rise/Fall Time : ≤20ns Serial Input / Output Timing tR SCL tF1 30% 30% 70% SDA (入力) (INPUT) 70% ACK ACK tWR tDH tPD tBUF D0 D1 70% 30% 30% DATA(n) DATA(1) tHD:DAT tSU:DAT 70% 70% 70% 70% 30% 30% tLOW tHD:STA 70% tHIGH 70% 70% 70% 30% 30% 30% 30% tSU:WP ○Input read at the rise edge of SCL ○Data output in sync with the fall of SCL Figure 1.-(d). WP Timing at Write Execution D1 tHD:STA DATA(n) DATA(1) 70% 70% tSU:STA tHD:WP STOP CONDITION tF2 Figure 1.-(a). Serial Input / Output Timing 70% 30% 70% 70% SDA (出力) (OUTPUT) tSU:STO D0 ACK ACK 70% tWR tHIGH:WP 70% 30% 70% 30% STOP CONDITION START CONDITION Figure 1.-(b) Start-Stop Bit Timing D0 write data ACK 70% Figure 1.-(e). WP Timing at Write Cancel 70% 70% tWR (n-th address) STOP CONDITION START CONDITION Figure 1.-(c). Write Cycle Timing www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 3/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Block Diagram 64Kbit EEPROM ARRAY Vcc 13bit 8bit ADDRESS DECODER 13bit SLAVE, WORD ADDRESS REGISTER START DATA REGISTER WP STOP SCL TEST CONTROL LOGIC ACK GND HIGH VOLTAGE GEN. SDA VCC LEVEL DETECT Figure 2. Block Diagram Pin Configuration 1 2 3 B1 B2 B3 SDA GND B A A1 SCL TEST A2 A3 WP VCC Figure 3. Pin Configuration (BOTTOM VIEW) Pin Descriptions Land No. Terminal Name Input / Output Descriptions B3 TEST Input B2 GND - B1 SDA Input / Output A3 VCC - A2 WP Input Write protect terminal A1 SCL Input Serial clock input www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 Slave address setting Reference voltage of all input / output, 0V Slave and word address Serial data input, serial data output Power Supply 4/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Typical Performance Curves 6 6 4 Input Low Voltage1,2: V IH1,2 (V) Input High Voltage : V IL1,2 (V) Ta=-40°C Ta= 25°C Ta= 85°C 5 3 SPEC 2 1 0 5 Ta=-40°C Ta= 25°C Ta= 85°C 4 3 2 1 SPEC 0 0 1 2 3 4 5 6 0 1 4 5 6 5 6 Figure 5. Input Low Voltage1,2 vs Supply Voltage Figure 4. Input High Voltage1,2, vs Supply Voltage 1 1 OL2 (V) Ta=-40°C Ta= 25°C 0.8 Ta= 85°C Output Low Voltage2: V OL1 (V) 3 Supply Voltage: Vcc(v) Supply Voltage: Vcc(v) Output Low Voltage1: V 2 0.6 SPEC 0.4 0.2 Ta=-40°C Ta= 25°C Ta= 85°C 0.8 0.6 0.4 SPEC 0.2 0 0 0 1 2 3 4 5 0 6 Output Low Current: IOL(m A) 2 3 4 Output Low Current: IOL(m A) Figure 6. Output Low Voltage1 vs Output Low Current (Vcc=2.5V) www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 1 Figure 7. Output Low Voltage2 vs Output Low Current (Vcc=1.6V) 5/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Typical Performance Curves‐continued 1.2 1.2 0.8 0.6 0.4 0.2 LO (µA) Ta=-40°C Ta= 25°C Ta= 85°C 1 Output Leakage Current: I Input Leakage Current: I LI (μA) SPEC 1 0.8 0 SPEC Ta=-40℃ Ta= 25℃ Ta= 85℃ 0.6 0.4 0.2 0 0 1 2 3 4 5 6 0 1 Supply Voltage: Vcc(V) 4 5 6 Figure 9. Output Leakage Current vs Supply Voltage (SDA) 0.6 2.5 0.5 CC2 (mA) 3 SPEC 2 Supply Current (Read): I CC1 (mA) Supply Current (Write): I 3 Supply Voltage: Vcc(v) Figure 8. Input Leakage Current vs Supply Voltage (SCL, WP, TEST) 1.5 2 Ta=-40°C Ta= 25°C Ta= 85°C 1 0.5 SPEC 0.4 Ta=-40°C Ta= 25°C Ta= 85°C 0.3 0.2 0.1 0 0 0 1 2 3 4 5 0 6 2 3 4 5 6 Supply Voltage: Vcc(V) Supply Voltage: Vcc(V) Figure 11. Supply Current (Read) vs Supply Voltage (fSCL=400kHz) Figure 10. Supply Current (Write) vs Supply Voltage (fSCL=400kHz) www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 1 6/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Typical Performance Curves‐continued 2.5 10000 SPEC 2 1.5 Ta=-40°C Ta= 25°C Ta= 85°C Clock Frequency: f Standby Current: I SB (µA) SCL (kHz) 1000 1 0.5 SPEC 100 Ta=-40°C Ta= 25°C Ta= 85°C 10 1 0.1 0 0 1 2 3 4 5 0 6 1 4 5 6 Figure 13. Clock Frequency vs Supply Voltage Figure 12. Standby Current vs Supply Voltage 1 LOW (µs) 1.5 0.8 Data Clock Low Period : t HIGH (µs) 3 Supply Voltage: Vcc(V) Supply Voltage: Vcc(V) Data Clock High Period : t 2 SPEC 0.6 Ta=-40°C Ta= 25°C Ta= 85°C 0.4 0.2 0 SPEC 1.2 0.9 Ta=-40°C Ta= 25°C Ta= 85°C 0.6 0.3 0 0 1 2 3 4 5 6 0 Supply Voltage: Vcc(V) 2 3 4 5 6 Supply Voltage: Vcc(V) Figure 14. Data Clock High Period vs Supply Voltage www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 1 Figure 15. Data Clock Low Period vs Supply Voltage 7/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Typical Performance Curves‐continued (µs) 1 SU:STA 0.8 0.8 SPEC Start Condition Setup Time: t Start Condition Hold Time: t HD:STA (µs) 1 SPEC 0.6 Ta=-40°C Ta= 25°C Ta= 85°C 0.4 0.2 0 0.6 0.4 Ta=-40°C Ta= 25°C Ta= 85°C 0.2 0 -0.2 0 1 2 3 4 5 6 0 1 Supply Voltage: Vcc(V) 4 5 6 Figure 17. Start Condition Setup Time vs Supply Voltage 50 50 HD:DAT (ns) SPEC 0 HD:DAT (ns) 3 Supply Voltage: Vcc(V) Figure 16. Start Condition Hold Time vs Supply Voltage -50 Input Data Hold Time: t Input Data Hold Time: t 2 Ta=-40°C Ta= 25°C Ta= 85°C -100 -150 -200 SPEC 0 -50 Ta=-40°C Ta= 25°C Ta= 85°C -100 -150 -200 0 1 2 3 4 5 6 0 Supply Voltage: Vcc(V) 2 3 4 5 6 Supply Voltage: Vcc(V) Figure 19. Input Data Hold Time vs Supply Voltage (LOW) Figure 18. Input Data Hold Time vs Supply Voltage (HIGH) www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 1 8/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Typical Performance Curves‐continued 300 SU:DAT (ns) SU:DAT (ns) 300 200 Input Data Setup Time: t SPEC Input Data Setup Time: t 100 0 Ta=-40°C Ta= 25°C Ta= 85°C -100 200 SPEC 100 0 Ta=-40°C Ta= 25°C Ta= 85°C -100 -200 -200 0 1 2 3 4 5 0 6 1 2 Figure 20. Input Data Setup Time vs Supply Voltage (HIGH) 5 6 Figure 21. Input Data Setup Time vs Supply Voltage (LOW) 2 2 PD 1.5 (µs) Ta=-40°C Ta= 25°C Ta= 85°C 1 Output Data Delay Time: t PD (µs) 4 Supply Voltage: Vcc(V) Supply Voltage: Vcc(V) Output Data Delay Time: t 3 SPEC 0.5 Ta=-40°C Ta= 25°C Ta= 85°C 1.5 1 SPEC 0.5 SPEC SPEC 0 0 1 2 3 4 5 6 Supply Voltage: Vcc(V) 0 1 2 3 4 5 6 Supply Voltage: Vcc(V) Figure 22. Output Data Delay Time vs Supply Voltage (LOW) www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 0 Figure 23. Output Data Delay Time vs Supply Voltage (HIGH) 9/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Typical Performance Curves‐continued 2 SU:STO (µs) 2 1.5 BUF (µs) Stop Condition Setup Time: t Ta=-40°C Ta= 25°C Ta= 85°C Bus Free Time: t 1 SPEC 0.5 1.5 SPEC 1 Ta=-40°C Ta= 25°C Ta= 85°C 0.5 0 0 -0.5 0 1 2 3 4 5 0 6 1 2 5 6 Figure 25. Bus Free Time vs Supply Voltage Figure 24. Stop Condition Setup Time vs Supply Voltage 6 0.6 SPEC Noise Spike Width (SCL HIGH):tI(µs) 5 W R (ms) 4 Supply Voltage: Vcc(V) Supply Voltage: Vcc(V) Write Cycle Time: t 3 4 3 2 Ta=-40°C Ta= 25°C Ta= 85°C 1 0 0.5 Ta=-40°C Ta= 25°C Ta= 85°C 0.4 0.3 0.2 0.1 SPEC 0 0 1 2 3 4 5 6 0 Supply Voltage: Vcc(V) 2 3 4 5 6 Supply Voltage: Vcc(V) Figure 26. Write Cycle Time vs Supply Voltage www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 1 Figure 27. Noise Spike Width vs Supply Voltage (SCL HIGH) 10/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Typical Performance Curves‐continued 0.6 0.5 0.4 Noise Spike Width (SDA HIGH): tI(µs) Noise Spike Width (SCL LOW): tI(µs) 0.6 Ta=-40°C Ta= 25°C Ta= 85°C 0.3 0.2 0.1 SPEC 0 0.5 Ta=-40°C Ta= 25°C Ta= 85°C 0.4 0.3 0.2 0.1 SPEC 0 0 1 2 3 4 5 6 0 1 2 Supply Voltage: Vcc(V) 4 5 6 Supply Voltage: Vcc(V) Figure 29. Noise Spike Width vs Supply Voltage (SDA HIGH) Figure 28. Noise Spike Width vs Supply Voltage (SCL LOW) 0.6 1.2 0.5 1 0.4 HD:W P (µs) SPEC Ta=-40°C Ta= 25°C Ta= 85°C WP Hold Time: t Noise Spike Width (SDA LOW): tI(µs) 3 0.3 0.2 0.1 0.8 Ta=-40°C Ta= 25°C Ta= 85°C 0.6 0.4 0.2 SPEC 0 0 0 1 2 3 4 5 6 0 Supply Voltage: Vcc(V) 2 3 4 5 6 Supply Voltage: Vcc(V) Figure 31. WP Hold Time vs Supply Voltage Figure 30. SDA Noise Spike Width (LOW) vs Supply Voltage (SDA LOW) www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 1 11/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Typical Performance Curves‐continued 0.2 1.2 SPEC ( µs) SPEC 0 -0.1 HIGH:W P Ta=-40°C Ta= 25°C Ta= 85°C WP High Period: t WP Setup Time: t SU:W P(µs) 0.1 -0.2 -0.3 -0.4 -0.5 -0.6 1 0.8 Ta=-40°C Ta= 25°C Ta= 85°C 0.6 0.4 0.2 0 0 1 2 3 4 5 6 0 1 2 3 4 5 Supply Voltage: Vcc(V) Supply Voltage: Vcc(V) Figure 32. WP Setup Time vs Supply Voltage Figure 33. WP High Period vs Supply Voltage www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 12/26 6 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Timing Chart 1. 2 I C BUS Data Communication I C BUS data communication starts by start condition input, and ends by stop condition input. Data is always 8bit long, 2 and acknowledge is always required after each byte. I C BUS data communication with several devices is possible by connecting with 2 communication lines: serial data (SDA) and serial clock (SCL). Among the devices, there should be a “master” that generates clock and control communication start and end. The rest become “slave” which are controlled by an address peculiar to each device, like this EEPROM. The device that outputs data to the bus during data communication is called “transmitter”, and the device that receives data is called “receiver”. 2 SDA 1-7 SCL S START ADDRESS condition 8 9 R/W ACK 1-7 8 DATA 9 ACK 1-7 DATA 8 9 ACK P STOP condition Figure 34. Data Transfer Timing 2. Start Condition (Start Bit Recognition) (1) Before executing each command, start condition (start bit) where SDA goes from 'HIGH' down to 'LOW' when SCL is 'HIGH' is necessary. (2) This IC always detects whether SDA and SCL are in start condition (start bit) or not, therefore, unless this condition is satisfied, any command cannot be executed. 3. Stop Condition (Stop Bit Recognition) (1) Each command can be ended by a stop condition (stop bit) where SDA goes from 'LOW' to 'HIGH' while SCL is 'HIGH'. 4. Acknowledge (ACK) Signal (1) The acknowledge (ACK) signal is a software rule to show whether data transfer has been made normally or not. In a master-slave communication, the device (Ex. µ-COM sends slave address input for write or read command, to this IC ) at the transmitter (sending) side releases the bus after output of 8bit data. (2) The device (Ex. This IC receives the slave address input for write or read command from the µ-COM) at the receiver (receiving) side sets SDA 'LOW' during the 9th clock cycle, and outputs acknowledge signal (ACK signal) showing that it has received the 8bit data. (3) This IC, after recognizing start condition and slave address (8bit), outputs acknowledge signal (ACK signal) 'LOW'. (4) After receiving 8bit data (word address and write data) during each write operation, this IC outputs acknowledge signal (ACK signal) 'LOW'.. (5) During read operation, this IC outputs 8bit data (read data) and detects acknowledge signal (ACK signal) 'LOW'. When acknowledge signal (ACK signal) is detected, and stop condition is not sent from the master (µ-COM) side, this IC continues to output data. When acknowledge signal (ACK signal) is not detected, this IC stops data transfer, recognizes stop condition (stop bit), and ends read operation. Then this IC becomes ready for another transmission. 5. Device Addressing (1) Slave address comes after start condition from master. (2) The significant 4 bits of slave address are used for recognizing a device type. The device code of this IC is fixed to '1010'. (3) Next slave addresses (A2 0 0 --- device address) are for selecting devices, and plural ones can be used on a same bus according to the number of device addresses. (4) The most insignificant bit ( R / W --- READ / WRITE ) of slave address is used for designating write or read operation, and is as shown below. Setting R / W to 0 ------- write (setting 0 to word address setting of random read) Setting R / W to 1 ------- read Maximum number of Connected buses Slave address 1 0 1 0 A2 0 0 ―― R/W www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 2 13/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Write Command 1. Write Cycle (1) Arbitrary data can be written to this EEPROM. When writing only 1 byte, Byte Write is normally used, and when writing continuous data of 2 bytes or more, simultaneous write is possible by Page Write cycle. Up to 32 arbitrary bytes can be written. S T A R T SDA LINE SLAVE ADDRESS W R I T E 2nd WORD ADDRESS 1st WORD ADDRESS 1 0 1 0 A2 0 0 * * * WA WA 12 11 WA 0 A C K R A / C W K S T O P DATA D7 D0 *Don't Care bit A C K A C K Figure 35. Byte Write Cycle S T A R T SDA LINE W R I T E SLAVE ADDRESS 2nd WORD ADDRESS(n) 1st WORD ADDRESS(n) WA WA 1 0 1 0 A2 0 0 *** DATA(n) WA D7 0 12 11 R A / C W K A C K S T O P DATA(n+31) D0 D0 *Don't Care bit A C K A C K A C K Figure 36. Page Write Cycle (2) (3) (4) (5) (6) During internal write execution, all input commands are ignored, therefore ACK is not returned. Data is written to the address designated by word address (n-th address) By issuing stop bit after 8bit data input, internal write to memory cell starts. When internal write is started, command is not accepted for tWR (5ms at maximum). Using page write cycle, writing in bulk is done as follows: When data of more than 32 bytes is sent, the bytes in excess overwrites the data already sent first. (Refer to "Internal Address Increment".) (7) As for page write cycle where 2 or more bytes of data is intended to be written, after the 8 significant bits of word address are designated arbitrarily, only the value of 5 least significant bits in the address is incremented internally, so that data up to 32 addresses of memory only can be written. 1 page=32bytes, but the page Write Cycle Time is 5ms at maximum for 32byte bulk write. It does not stand 5ms at maximum × 32byte=160ms(Max) 2. Internal Address Increment Page Write Mode 1Eh WA7 WA6 WA5 WA4 WA3 WA2 WA1 WA0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 1 1 0 1 1 0 1 1 0 1 1 0 0 1 0 Significant bit is fixed. No digit up Increment For example, when it is started from address 1Eh, then, increment is made as below, 1Eh→1Fh→00h→01h・・・ please take note. ※1Eh・・・1E in hexadecimal, therefore, 00011110 becomes a binary number. 3. Write Protect (WP) Terminal Write Protect (WP) Function When WP terminal is set at Vcc (H level), data rewrite of all addresses is prohibited. When it is set at GND (L level), data rewrite of all address is enabled. Be sure to connect this terminal to Vcc or GND, or control it to H level or L level. Do not leave it open. At extremely low voltage at power ON / OFF, by setting the WP terminal 'H', write error can be prevented. www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 14/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Read Command 1. Read Cycle Read cycle is when data of EEPROM is read. Read cycle could be random read cycle or current read cycle. Random read cycle is a command to read data by designating a specific address, and is used generally. Current read cycle is a command to read data of internal address register without designating an address, and is used when to verify just after write cycle. In both the read cycles, sequential read cycle is available where the next address data can be read in succession. S T A R T W R I T E SLAVE ADDRESS SDA LINE 1st WORD ADDRESS ( ) 2nd WORD ADDRESS (n ) R E A D SLAVE ADDRESS S T O P DATA(n) WA WAWA 1 0 1 0 A2 0 0 S T A R T 1 0 1 0 A2 0 0 0 * * * 12 11 R A / C WK A C K A C K D7 D0 R A / C W K *Don't Care bit A C K Figure 37. Random Read Cycle S T A R T SDA LINE R E A D SLAVE ADDRESS 1 0 1 0 A2 S T O P DAT A(n) D7 0 0 D0 A C K R A / C WK Figure 38. Current Read Cycle S T A R T SDA LINE SLAVE ADDRESS R E A D 1 0 1 0 A2 0 0 DATA(n) D7 R A / C W K S T O P DATA(n+x) D0 D7 A C K A C K D0 A C K Figure 39. Sequential Read Cycle (in the case of Current Read Cycle) (1) In Random Read Cycle, data of designated word address can be read. (2) When the command just before current read cycle is random read cycle, current read cycle (each including sequential read cycle), data of incremented last read address (n)-th, i.e., data of the (n+1)-th address, is output. (3) When ACK signal 'LOW' after D0 is detected, and stop condition is not sent from master (µ-COM) side, the next address data can be read in succession. (4) Read cycle is ended by stop condition where 'H' is input to ACK signal after D0 and SDA signal goes from ‘L’ to ‘H’ while SCL signal is 'H' . (5) When 'H' is not input to ACK signal after D0, sequential read gets in, and the next data is output. Therefore, read command cycle cannot be ended. To end the read command cycle, be sure to input 'H' to ACK signal after D0, and the stop condition where SDA goes from ‘L’ to ‘H’ while SCL signal is 'H'. (6) Sequential read is ended by stop condition where 'H' is input to ACK signal after arbitrary D0 and SDA is asserted from ‘L’ to ‘H’ while SCL signal is 'H'. www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 15/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Software Reset Software reset is executed to avoid malfunction after power on and during command input. Software reset has several kinds and 3 kinds of them are shown in the figure below. (Refer to Figure 40.-(a), Figure 40.-(b), and Figure 40.-(c).) Within the dummy clock input area, the SDA bus is released ('H' by pull up) and ACK output and read data '0' (both 'L' level) may be output from EEPROM. Therefore, if 'H' is input forcibly, output may conflict and over current may flow, leading to instantaneous power failure of system power source or influence upon devices. Dummy clock×14 SCL 1 2 Start×2 13 Normal command 14 SDA Normal command Figure 40.-(a) The case of dummy clock×14 + START+START+ command input SCL Start Dummy clock×9 Start 1 2 8 Normal command 9 SDA Normal command Figure 40.-(b) The case of START + dummy clock×9 + START + command input Start×9 SCL 1 2 3 7 8 Normal command 9 SDA Normal command SD Figure 40.-(c) START×9 + command input ※Start command from START input. Acknowledge Polling During internal write execution, all input commands are ignored, therefore ACK is not returned. During internal automatic write execution after write cycle input, next command (slave address) is sent.If the first ACK signal sends back 'L', then it means end of write operation, else 'H' is returned, which means writing is still in progress. By the use of acknowledge polling, next command can be executed without waiting for tWR = 5ms. To write continuously, R / W = 0, then to carry out current read cycle after write, slave address with R / W = 1 is sent. If ACK signal sends back 'L', then execute word address input and data output and so forth. During internal write, ACK = HIGH is returned. First write command S T A R T Write Command S T O P S T Slave A R Address T S T Slave A R Address T A C K H A C K H … tWR Second write command … S T Slave A R Address T A C K H S T Slave A R Address T A C K L Word Address A C K L Data A C K L S T O P tWR After completion of internal write, ACK=LOW is returned, so input next word address and data in succession. Figure 41. Case of continuous write by Acknowledge Polling www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 16/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 WP Valid Timing (Write Cancel) WP is usually fixed to 'H' or 'L', but when WP is used to cancel write cycle and so on, pay attention to the following WP valid timing. During write cycle execution, inside cancel valid area, by setting WP='H', write cycle can be cancelled. In both byte write cycle and page write cycle, the area from the first start condition of command to the rise of clock to take in D0 of data(in page write cycle, the first byte data) is the cancel invalid area. WP input in this area becomes ‘Don't care’. The area from the rise of SCL to take in D0 to the stop condition input is the cancel valid area. Furthermore, after the execution of forced end by WP, the IC enters standby status. ・Rise of SDA ・Rise of D0 taken clock SCL SDA SCL D1 D0 ACK SDA Enlarged view SDA S T Slave A R Address T A C Word K Address L D0 ACK Enlarged view A C D7 D6 D5 D4 D3 D2 D1 D0 K L WP cancel invalid area A C K L Data A C K L S T O P WP cancel valid area tWR WP cancel invalid area WP Data is not written. Figure 42. WP Valid Timing Command Cancel by Start Condition and Stop Condition During command input, by continuously inputting start condition and stop condition, command can be cancelled. (Figure 43.) However, within ACK output area and during data read, SDA bus may output 'L'. In this case, start condition and stop condition cannot be input, so reset is not available. Therefore, execute software reset. When command is cancelled by start-stop condition during random read cycle, sequential read cycle, or current read cycle, internal setting address is not determined. Therefore, it is not possible to carry out current read cycle in succession. To carry out read cycle in succession, carry out random read cycle. SCL SDA 1 0 1 0 Start condition Stop condition Figure 43. Case of cancel by start, stop condition during Slave Address Input www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 17/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 I/O Peripheral Circuit 1. Pull Up Resistance of SDA Terminal SDA is NMOS open drain, so it requires a pull up resistor. As for this resistance value (RPU), select an appropriate value from microcontroller VIL, IL, and VOL-IOL characteristics of this IC. If RPU is large, operating frequency is limited. The smaller the RPU, the larger is the supply current (Read). 2. Maximum Value of RPU The maximum value of RPU is determined by the following factors: (1)SDA rise time to be determined by the capacitance (CBUS) of bus line and RPU of SDA should be tR or lower. Furthermore, AC timing should be satisfied even when SDA rise time is slow. A to be determined by the input current leak total (IL) of the device connected to the bus (2)The bus’ electric potential ○ with output of 'H' to the SDA line and RPU should sufficiently secure the input 'H' level (VIH) of microcontroller and EEPROM including recommended noise margin of 0.2Vcc. VCC - ILRPU - 0.2 VCC ≥VIH Microcontroller 0.8VCC -VIH ≤ IL ∴RPU Ex.) Vcc =3V from(2) EEPROM RPU IL=10µA VIH=0.7 Vcc IL IL 0.8 × 3 - 0.7 × 3 ≤ 10 × 10 -6 ∴RPU SDA terminal A ≤30 Bus Line Capacity CBUS [kΩ ] Figure 44. I/O Circuit Diagram 3. Minimum Value of RPU The minimum value of RPU is determined by the following factors: (1)When IC outputs LOW, it should be satisfied that VOLMAX=0.4V and IOLMAX=3mA. VCC -VOL ≤ IOL RPU VCC -VOL IOL ∴RPU ≥ (2)VOLMAX=0.4V should secure the input 'L' level (VIL) of microcontroller and EEPROM including the recommended noise margin of 0.1Vcc. VOLMAX ≤VIL ‐ 0.1VCC Ex.) VCC =3V, VOL=0.4V, IOL=3mA, microcontroller, EEPROM VIL=0.3Vcc from (1) ∴RPU ≥ 3 - 0.4 3 × 10 -3 ≥867 And [Ω ] VOL = 0.4 [V ] VIL = 0.3 × 3 = 0.9 [V ] Therefore, the condition (2) is satisfied. 4. Pull-up Resistance of SCL Terminal When SCL control is made at the CMOS output port, there is no need for a pull up resistor. But when there is a time where SCL becomes 'Hi-Z', add a pull up resistor. As for the pull up resistor value, one of several kΩ to several ten kΩ is recommended in consideration of drive performance of output port of microcontroller. www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 18/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Cautions on Microcontroller Connection 1. RS In I2C BUS, it is recommended that SDA port is of open drain input/output. However, when using CMOS input / output of tri state to SDA port, insert a series resistance RS between the pull up resistor RPU and the SDA terminal of EEPROM. This is to control over current that may occur when PMOS of the microcontroller and NMOS of EEPROM are turned ON simultaneously. RS also plays the role of protecting the SDA terminal against surge. Therefore, even when SDA port is open drain input/output, RS can be used. ACK SCL RPU RS SDA 'H' output of microcontroller 'L' output of EEPROM Microcontroller EEPROM Over current flows to SDA line by 'H' output of microcontroller and 'L' output of EEPROM. Figure 45. I/O Circuit Diagram Figure 46. Input / Output Collision Timing 2. Maximum Value of RS The maximum value of RS is determined by the following relations: (1)SDA rise time to be determined by the capacitance (CBUS) of bus line and RPU of SDA should be tR or lower. Furthermore, AC timing should be satisfied even when SDA rise time is slow. (2)The bus’ electric potential ○ A to be determined by RPU and RS the moment when EEPROM outputs 'L' to SDA bus should sufficiently secure the input 'L' level (VIL) of microcontroller including recommended noise margin of 0.1Vcc. VCC RPU A RS VOL IOL Ex)VCC=3V Bus line capacity CBUS VIL Micro controller (VCC -VOL ) × RS +VOL + 0.1VCC ≤VIL RPU + RS VIL -VOL - 0.1VCC ∴RS ≤ × RPU 1.1VCC -VIL RS ≤ EEPROM Figure 47. I/O Circuit Diagram VIL=0.3VCC VOL=0.4V RPU=20kΩ 0.3 × 3 - 0.4 - 0.1 × 3 × 20 × 10 3 1.1 × 3 - 0.3 × 3 ≤1.67 [ kΩ ] 3. Minimum Value of RS The minimum value of RS is determined by over current at bus collision. When over current flows, noises in power source line and instantaneous power failure of power source may occur. When allowable over current is defined as I, the following relation must be satisfied. Determine the allowable current in consideration of the impedance of power source line in set and so forth. Set the over current to EEPROM at 10mA or lower. RPU 'L'output RS VCC ≤I RS VCC I ∴Rs ≥ Over current I EX) VCC=3V I=10mA 'H' output Microcontroller EEPROM Rs ≥ Figure 48. I/O circuit diagram www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 3 10 × 10 ≥300 19/26 -3 [Ω ] TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 I/O Equivalence Circuit 1. Input (SCL, WP, TEST) Figure 49. Input Pin Circuit Diagram 2. Input / Output (SDA) Figure 50. Input / Output Pin Circuit Diagram www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 20/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Power-Up/Down Conditions At power on, the IC’s internal circuits may go through unstable low voltage area as the Vcc rises, making the IC’s internal logic circuit not completely reset, hence, malfunction may occur. To prevent this, the IC is equipped with POR circuit and LVCC circuit. To assure the operation, observe the following conditions at power on. 1. Set SDA = 'H' and SCL ='L' or 'H’ 2. Start power source so as to satisfy the recommended conditions of tR, tOFF, and Vbot for operating POR circuit. tR Recommended conditions of tR, tOFF,Vbot VCC tOFF tR tOFF Vbot 0 Figure 51. Vbot 10ms or below 10ms or larger 0.3V or below 100ms or below 10ms or larger 0.2V or below Rise Waveform Diagram 3. Set SDA and SCL so as not to become 'Hi-Z'. When the above conditions 1 and 2 cannot be observed, take the following countermeasures. (1) In the case when the above condition 1 cannot be observed such that SDA becomes 'L' at power on. →Control SCL and SDA as shown below, to make SCL and SDA, 'H' and 'H'. VCC tLOW SCL SDA After Vcc becomes stable After Vcc becomes stable tDH tSU:DAT Figure 52. When SCL= 'H' and SDA= 'L' tSU:DAT Figure 53. When SCL='L' and SDA='L' (2) In the case when the above condition 2 cannot be observed. →After power source becomes stable, execute software reset(Page 16). (3) In the case when the above conditions 1 and 2 cannot be observed. →Carry out (1), and then carry out (2). Low Voltage Malfunction Prevention Function LVCC circuit prevents data rewrite operation at low power and prevents data rewrite is prevented. write error. At LVCC voltage (Typ =1.2V) or below, Noise Countermeasures 1. Bypass Capacitor When noise or surge gets in the power source line, malfunction may occur, therefore, it is recommended to connect a bypass capacitor (0.1µF) between the IC’s Vcc and GND pins. Connect the capacitor as close to the IC as possible. In addition, it is also recommended to attach a bypass capacitor between the board’s Vcc and GND. www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 21/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Operational Notes 1. Reverse Connection of Power Supply Connecting the power supply in reverse polarity can damage the IC. Take precautions against reverse polarity when connecting the power supply, such as mounting an external diode between the power supply and the IC’s power supply pins. 2. Power Supply Lines Design the PCB layout pattern to provide low impedance supply lines. Separate the ground and supply lines of the digital and analog blocks to prevent noise in the ground and supply lines of the digital block from affecting the analog block. Furthermore, connect a capacitor to ground at all power supply pins. Consider the effect of temperature and aging on the capacitance value when using electrolytic capacitors. 3. Ground Voltage Ensure that no pins are at a voltage below that of the ground pin at any time, even during transient condition. 4. Ground Wiring Pattern When using both small-signal and large-current ground traces, the two ground traces should be routed separately but connected to a single ground at the reference point of the application board to avoid fluctuations in the small-signal ground caused by large currents. Also ensure that the ground traces of external components do not cause variations on the ground voltage. The ground lines must be as short and thick as possible to reduce line impedance. 5. Thermal Consideration Should by any chance the power dissipation rating be exceeded the rise in temperature of the chip may result in deterioration of the properties of the chip. The absolute maximum rating of the Pd stated in this specification is when the IC is mounted on a 70mm x 70mm x 1.6mm glass epoxy board. In case of exceeding this absolute maximum rating, increase the board size and copper area to prevent exceeding the Pd rating. 6. Recommended Operating Conditions These conditions represent a range within which the expected characteristics of the IC can be approximately obtained. The electrical characteristics are guaranteed under the conditions of each parameter. 7. Inrush Current When power is first supplied to the IC, it is possible that the internal logic may be unstable and inrush current may flow instantaneously due to the internal powering sequence and delays, especially if the IC has more than one power supply. Therefore, give special consideration to power coupling capacitance, power wiring, width of ground wiring, and routing of connections. 8. Operation Under Strong Electromagnetic Field Operating the IC in the presence of a strong electromagnetic field may cause the IC to malfunction. 9. Testing on Application Boards When testing the IC on an application board, connecting a capacitor directly to a low-impedance output pin may subject the IC to stress. Always discharge capacitors completely after each process or step. The IC’s power supply should always be turned off completely before connecting or removing it from the test setup during the inspection process. To prevent damage from static discharge, ground the IC during assembly and use similar precautions during transport and storage. 10. Inter-pin Short and Mounting Errors Ensure that the direction and position are correct when mounting the IC on the PCB. Incorrect mounting may result in damaging the IC. Avoid nearby pins being shorted to each other especially to ground, power supply and output pin. Inter-pin shorts could be due to many reasons such as metal particles, water droplets (in very humid environment) and unintentional solder bridge deposited in between pins during assembly to name a few. www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 22/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Operational Notes – continued 11. Unused Input Pins Input pins of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. So unless otherwise specified, unused input pins should be connected to the power supply or ground line. 12. Regarding the Input Pin of the IC In the construction of this IC, P-N junctions are inevitably formed creating parasitic diodes or transistors. The operation of these parasitic elements can result in mutual interference among circuits, operational faults, or physical damage. Therefore, conditions which cause these parasitic elements to operate, such as applying a voltage to an input pin lower than the ground voltage should be avoided. Furthermore, do not apply a voltage to the input pins when no power supply voltage is applied to the IC. Even if the power supply voltage is applied, make sure that the input pins have voltages within the values specified in the electrical characteristics of this IC. www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 23/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Part Numbering B R C G 0 6 4 G W Z - 3 E 2 BUS type 2 C:I C Revision Capacity 064=64K Package GWZ:UCSP35L1 Process Code Packaging and forming specification E2:: Embossed tape and reel www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 24/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Physical Dimension Tape and Reel Information Package Name UCSP35L1(BRCG064GWZ-3) 1PIN MARK Lot No. 1.0±0.05 ADJ 0.06 0.36MAX 1.5±0.05 S 0.06 S 0.05 A B 0.3±0.05 6-φ0.20±0.05 A B 0.4 B A 1 2 0.35±0.05 3 P=0.4×2 (Unit : mm) < Tape and Reel Information > Tape Embossed carrier tape Quantity 3000pcs Direction of feed E2 The direction is the pin 1 of product is at the upper left when you hold reel on the left hand and you pull out the tape on the right hand 1234 1234 Reel www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 1234 1234 1234 1234 Direction of feed 1pin 25/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet BRCG064GWZ-3 Marking Diagram UCSP35L1(BRCG064GWZ-3) (TOP VIEW) 1PIN MARK Part Number Marking A D J LOT Number Revision History Date Revision 20.Jan.2014 001 www.rohm.com ©2014 ROHM Co., Ltd. All rights reserved. TSZ22111・15・001 Changes New Release 26/26 TSZ02201-0R2R0G100650-1-2 20.Jan.2014 Rev.001 Datasheet Notice Precaution on using ROHM Products 1. Our Products are designed and manufactured for application in ordinary electronic equipments (such as AV equipment, OA equipment, telecommunication equipment, home electronic appliances, amusement equipment, etc.). If you (Note 1) , transport intend to use our Products in devices requiring extremely high reliability (such as medical equipment equipment, traffic equipment, aircraft/spacecraft, nuclear power controllers, fuel controllers, car equipment including car accessories, safety devices, etc.) and whose malfunction or failure may cause loss of human life, bodily injury or serious damage to property (“Specific Applications”), please consult with the ROHM sales representative in advance. Unless otherwise agreed in writing by ROHM in advance, ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of any ROHM’s Products for Specific Applications. (Note1) Medical Equipment Classification of the Specific Applications JAPAN USA EU CHINA CLASSⅢ CLASSⅡb CLASSⅢ CLASSⅢ CLASSⅣ CLASSⅢ 2. ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which a failure or malfunction of our Products may cause. The following are examples of safety measures: [a] Installation of protection circuits or other protective devices to improve system safety [b] Installation of redundant circuits to reduce the impact of single or multiple circuit failure 3. Our Products are designed and manufactured for use under standard conditions and not under any special or extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the use of any ROHM’s Products under any special or extraordinary environments or conditions. If you intend to use our Products under any special or extraordinary environments or conditions (as exemplified below), your independent verification and confirmation of product performance, reliability, etc, prior to use, must be necessary: [a] Use of our Products in any types of liquid, including water, oils, chemicals, and organic solvents [b] Use of our Products outdoors or in places where the Products are exposed to direct sunlight or dust [c] Use of our Products in places where the Products are exposed to sea wind or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2 [d] Use of our Products in places where the Products are exposed to static electricity or electromagnetic waves [e] Use of our Products in proximity to heat-producing components, plastic cords, or other flammable items [f] Sealing or coating our Products with resin or other coating materials [g] Use of our Products without cleaning residue of flux (even if you use no-clean type fluxes, cleaning residue of flux is recommended); or Washing our Products by using water or water-soluble cleaning agents for cleaning residue after soldering [h] Use of the Products in places subject to dew condensation 4. The Products are not subject to radiation-proof design. 5. Please verify and confirm characteristics of the final or mounted products in using the Products. 6. In particular, if a transient load (a large amount of load applied in a short period of time, such as pulse. is applied, confirmation of performance characteristics after on-board mounting is strongly recommended. Avoid applying power exceeding normal rated power; exceeding the power rating under steady-state loading condition may negatively affect product performance and reliability. 7. De-rate Power Dissipation (Pd) depending on Ambient temperature (Ta). When used in sealed area, confirm the actual ambient temperature. 8. Confirm that operation temperature is within the specified range described in the product specification. 9. ROHM shall not be in any way responsible or liable for failure induced under deviant condition from what is defined in this document. Precaution for Mounting / Circuit board design 1. When a highly active halogenous (chlorine, bromine, etc.) flux is used, the residue of flux may negatively affect product performance and reliability. 2. In principle, the reflow soldering method must be used; if flow soldering method is preferred, please consult with the ROHM representative in advance. For details, please refer to ROHM Mounting specification Notice - GE © 2014 ROHM Co., Ltd. All rights reserved. Rev.002 Datasheet Precautions Regarding Application Examples and External Circuits 1. If change is made to the constant of an external circuit, please allow a sufficient margin considering variations of the characteristics of the Products and external components, including transient characteristics, as well as static characteristics. 2. You agree that application notes, reference designs, and associated data and information contained in this document are presented only as guidance for Products use. Therefore, in case you use such information, you are solely responsible for it and you must exercise your own independent verification and judgment in the use of such information contained in this document. ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of such information. Precaution for Electrostatic This Product is electrostatic sensitive product, which may be damaged due to electrostatic discharge. Please take proper caution in your manufacturing process and storage so that voltage exceeding the Products maximum rating will not be applied to Products. Please take special care under dry condition (e.g. Grounding of human body / equipment / solder iron, isolation from charged objects, setting of Ionizer, friction prevention and temperature / humidity control). Precaution for Storage / Transportation 1. Product performance and soldered connections may deteriorate if the Products are stored in the places where: [a] the Products are exposed to sea winds or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2 [b] the temperature or humidity exceeds those recommended by ROHM [c] the Products are exposed to direct sunshine or condensation [d] the Products are exposed to high Electrostatic 2. Even under ROHM recommended storage condition, solderability of products out of recommended storage time period may be degraded. It is strongly recommended to confirm solderability before using Products of which storage time is exceeding the recommended storage time period. 3. Store / transport cartons in the correct direction, which is indicated on a carton with a symbol. Otherwise bent leads may occur due to excessive stress applied when dropping of a carton. 4. Use Products within the specified time after opening a humidity barrier bag. Baking is required before using Products of which storage time is exceeding the recommended storage time period. Precaution for Product Label QR code printed on ROHM Products label is for ROHM’s internal use only. Precaution for Disposition When disposing Products please dispose them properly using an authorized industry waste company. Precaution for Foreign Exchange and Foreign Trade act Since our Products might fall under controlled goods prescribed by the applicable foreign exchange and foreign trade act, please consult with ROHM representative in case of export. Precaution Regarding Intellectual Property Rights 1. All information and data including but not limited to application example contained in this document is for reference only. ROHM does not warrant that foregoing information or data will not infringe any intellectual property rights or any other rights of any third party regarding such information or data. ROHM shall not be in any way responsible or liable for infringement of any intellectual property rights or other damages arising from use of such information or data.: 2. No license, expressly or implied, is granted hereby under any intellectual property rights or other rights of ROHM or any third parties with respect to the information contained in this document. Other Precaution 1. This document may not be reprinted or reproduced, in whole or in part, without prior written consent of ROHM. 2. The Products may not be disassembled, converted, modified, reproduced or otherwise changed without prior written consent of ROHM. 3. In no event shall you use in any way whatsoever the Products and the related technical information contained in the Products or this document for any military purposes, including but not limited to, the development of mass-destruction weapons. 4. The proper names of companies or products described in this document are trademarks or registered trademarks of ROHM, its affiliated companies or third parties. Notice - GE © 2014 ROHM Co., Ltd. All rights reserved. Rev.002 Datasheet General Precaution 1. Before you use our Pro ducts, you are requested to care fully read this document and fully understand its contents. ROHM shall n ot be in an y way responsible or liabl e for fa ilure, malfunction or acci dent arising from the use of a ny ROHM’s Products against warning, caution or note contained in this document. 2. All information contained in this docume nt is current as of the issuing date and subj ect to change without any prior notice. Before purchasing or using ROHM’s Products, please confirm the la test information with a ROHM sale s representative. 3. The information contained in this doc ument is provi ded on an “as is” basis and ROHM does not warrant that all information contained in this document is accurate an d/or error-free. ROHM shall not be in an y way responsible or liable for an y damages, expenses or losses incurred b y you or third parties resulting from inaccur acy or errors of or concerning such information. Notice – WE © 2014 ROHM Co., Ltd. All rights reserved. Rev.001