ETC2 FN409-13-02 75vdc input pcb fi lter Datasheet

PCB filters
FN 409
75VDC input PCB filter
■
■
■
■
Rated currents from 3 to 13A, 75VDC
Very compact PCB-mounting design
Exceptional attenuation performance
High frequency noise compression
Technical specifications
Maximum continuous operating voltage:
Rated currents:
High potential test voltage:
Temperature range (operation and storage):
Design corresponding to:
Flammability corresponding to:
MTBF @ 40°C/75V (Mil-HB-217F):
Approvals
Typical electrical schematic
75VDC
3 to 13A
VI1/VI2 –> GND 2000VDC for 2 sec
VI1 –> VI2 100VDC for 2 sec
-40°C to +100°C (25/100/21)
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
UL 94V-2 or better
4,450,000 hours
3 and 6.5A types
Cx
2xL
2xL
VO2
VI2
VO1
VI1
2xCy
GND
13A types
Cx
2xL
2xL1
2xL1
VI2
VO2
VI1
VO1
2xCy
GND
Features and benefits
FN 409 PCB filters are designed to surpress
■
High common and differential-mode noise
Typical applications
■
suppression.
common and differential-mode noise on DC
voltage lines. The suppression performance
■
Rated currents up to 13A at 75VDC.
is special designed to fulfill the require-
■
Small form factor.
ments for high frequency switching DC/
■
Good thermal conductance.
DC/DC converters
■
DC output filter for switch-mode power
supplies
■
Computer and office automation
equipment
DC converter modules. FN 409 filters can
also be used to filter the output current of
■
switch-mode power supplies in applications
■
with intelligent power distribution.
Input or output filter for high frequency
Telecom equipment
Input/output filter within DC power
distribution networks
> Components > FN 409
Filter selection table
Filter
Rated current
@ 50°C (40°C)
L
[A]
3 (3.2)
6.5 (7)
13 (14)
[mH]
2.9
0.5
0.08
FN 409-3-02
FN 409-6.5-02
FN 409-13-02
Inductance
L1
[mH]
0.18
Capacitance
Cx
Cy
[nF]
4700
4700
4700
DC Resistance R
@ 25°C per path
Input/Output
connections
[mΩ]
86
18
7.8
-02
-02
-02
[nF]
4.7
4.7
4.7
Weight
[g]
30
30
47
Typical filter attenuation
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym; C = 0.1Ω/100Ω sym; D = 100Ω/0.1Ω sym
3A types
13A types
6.5A types
Mechanical data
3 and 6.5A types
13A types
0.5
5.08
3.8
VI1
VI2
27.9 max.
6.4
5.08
5.08
5.08
All dimensions in mm; 1 inch = 25.4mm
Tolerances according: ISO 2768-m / EN 22768-m
50.8 max.
7.4 +1/-0
Ø1 ±0.05
11.7 max.
VO1 GND
4.6
0.5
VO2
19.05
3.8
17.8
VI2
50.8 max.
Ø0.8 ±0.05
VO2
VO1
VI1 GND
5.08
25.4
3.8
12.1
31.1
5.08
12.7 max.
5.1 +1/-0
40.6 max.
> Components > FN 409
Application
The filters are intended to be used in DC
(VDR, fig. 1) or a transient diode (fig. 2) must
voltage is superimposed on DC voltage, VP-P
applications per EN/IEC 60950, where no
be placed at the input side of the filter module.
or VO-P, whichever is larger, should be
transient on the DC bus occurs. To protect the
For protection against overcurrent place a
maintained within the rated voltage range.
filter against transient voltages a varistor
fuse on each input lead (VI+, VI-). When AC
VI1+
Varistor
VI2-
Input
+
+
Filter module Output
FN 409
-
VO1+
VO2-
VI1+
VI2-
Transient
diode
Input
+
+
Filter module
FN 409
-
Chassis
ground
Chassis
ground
Figure 1: transient protection with a varistor
Figure 2: transient protection with a transient diode
VO1+
Output
VO2-
Recommended layout
Filter module
VI1+
VO1+
VI2-
VO2-
Chassis
ground
Note: avoid routing signal tracks or planes under the filter module