AC centrifugal fan D4E180-CA02-02 forward curved, dual inlet with housing (large flange) ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 [email protected] www.ebmpapst.com Limited partnership · Headquarters Mulfingen County court Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen County court Stuttgart · HRB 590142 Nominal data Type D4E180-CA02-02 Motor M4E068-LA Phase 1~ 1~ Nominal voltage VAC 230 230 Frequency Hz 50 60 Type of data definition fa fa Valid for approval / standard CE CE Speed min-1 1250 1280 Power input W 380 495 Current draw A 1.68 2.16 Motor capacitor µF 10 10 Capacitor voltage VDB 400 400 Min. back pressure Pa 0 0 Min. ambient temperature °C -25 -25 Max. ambient temperature °C 60 35 Starting current A 3.3 3.1 ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit Subject to alterations Data according to ErP directive Request 2013 Request 2015 32 31.4 38.4 42.6 42 49 B Overall efficiency ηe Efficiency category Total Efficiency grade N Variable speed drive No Power input Pe kW 0.21 Specific ratio* 1.00 Air flow qv m³/h 1130 Pressure increase pf Pa 219 Speed n min-1 1410 * Specific ratio = 1 + pf / 100 000 Pa % Actual Installation category Data definition with optimum efficiency. LU-105030 The ErP data is determined using a motor-impeller combination in a standardised measurement configuration. Item no. 11270-5-9980 · Revision 82891 · Release 2014-04-15 · Page 1 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com AC centrifugal fan D4E180-CA02-02 forward curved, dual inlet with housing (large flange) Technical features Mass 10.24 kg Size 180 mm Surface of rotor Coated in black Material of impeller Sheet steel, hot-galvanised Housing material Sheet steel, hot-galvanised Motor suspension Motor anti-vibration mounted on both sides Direction of rotation Counter-clockwise, seen on rotor Type of protection IP 54 Insulation class "B" Humidity class F3-1 Max. permissible ambient motor temp. (transp./ storage) + 80 °C Min. permissible ambient motor temp. (transp./storage) - 40 °C Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) wired internally Protection class I (if protective earth is connected by customer) Product conforming to standard EN 60335-1 Approval CCC Item no. 11270-5-9980 · Revision 82891 · Release 2014-04-15 · Page 2 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com AC centrifugal fan D4E180-CA02-02 forward curved, dual inlet with housing (large flange) Product drawing 1 Connection line PVC 4G 0.5 mm², 4 x brass lead tips crimped Connection screen U1 blue PE green/yellow Z brown U2 black Item no. 11270-5-9980 · Revision 82891 · Release 2014-04-15 · Page 3 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com AC centrifugal fan D4E180-CA02-02 forward curved, dual inlet with housing (large flange) Charts: Air flow 50 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 qv[cfm] 270 0 200 400 600 800 1.000 1.200 1.400 260 1,05 250 1 240 0,95 230 0,9 4 220 210 0,85 200 0,8 190 0,75 3 180 pf s[Pa] 160 0,65 150 0,6 140 0,55 130 0,5 120 0,45 110 2 100 0,4 90 0,35 80 0,3 70 60 0,25 50 0,2 40 0,15 30 0,1 a] pf s[P 20 10 0 p fs_E[IN H2O] 0,7 170 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 1 0 200 400 600 800 1.000 1.200 qv[m^3/h] 1.400 1.600 1.800 2.000 2.200 0,05 0 2.400 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 230 50 1250 380 1.68 2155 0 2 230 50 1330 302 1.34 1810 100 3 230 50 1385 245 1.10 1375 180 4 230 50 1430 191 0.89 900 220 U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 11270-5-9980 · Revision 82891 · Release 2014-04-15 · Page 4 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com AC centrifugal fan D4E180-CA02-02 forward curved, dual inlet with housing (large flange) Charts: Air flow 60 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 200 400 600 800 1.000 1.200 1.400 1,55 1,5 1,45 1,4 1,35 1,3 1,25 4 1,2 1,15 1,1 3 1,05 1 0,95 0,9 0,85 0,8 0,75 0,7 p fs_E[IN H2O] pf s[Pa] qv[cfm] Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,65 0,6 2 0,55 0,5 0,45 0,4 0,35 0,3 0,25 0,2 0,15 ] pf s[Pa 390 380 370 360 350 340 330 320 310 300 290 280 270 260 250 240 230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0 1 0 200 400 600 800 1.000 1.200 qv[m^3/h] 1.400 1.600 1.800 2.000 2.200 0,1 0,05 0 2.400 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 230 60 1280 495 2.16 2180 0 2 230 60 1470 410 1.79 1915 140 3 230 60 1600 331 1.48 1450 260 4 230 60 1660 280 1.29 1075 300 U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 11270-5-9980 · Revision 82891 · Release 2014-04-15 · Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com