ETC2 AFB0924SH 92 x 92 x 25.4 mm sery Datasheet

AFB
92 x 92 x 25.4 MM SERIES
DRAWING
25.4 0.5
92.0 0.5
(3.622 0.020)
(1.000 0.020)
4.0 0.3
(0.157 0.012)
82.5 0.3
(3.248 0.012)
LABEL
6.0
H
0.18
4.5
M
0.12
3.0
0.06
1.5
0
0
INLET SIDE
HH
88.0
(3.465)
88.0
(3.465)
82.5
(3.248)
82.5
(3.248)
82.5
(3.248)
(
88.0
(3.465)
1
4. 03.
07 4
1)
L
95
75 .4
6)
0.24
(mm H2O)
7.5
PANEL CUTOUT
OUTLET SIDE
VH
mm
(INCH)
3.
AFB0912/24/48X
9.0
0.30
(IN H 2O)
Air Pressure
0.36
■ MOUNTING
UNIT :
0
0.5
0
20.0
1.0
1.5
40.0
2.0
60.0
3
2.5 (M /MIN)
80.0
4- 4.5
(4- 0.177)
4- 4.5
(4- 0.177)
(CFM)
Air Flow
UNIT:
mm
(INCH)
Rated
Voltage
Operating
Voltage
Range
Input
Current
Input
Power
Speed
FUNCTION
VDC
VDC
Amp
Watt
R.P.M.
m3 /min
CFM
mmH2O
IN H2O
dB-A
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
12
24
48
12
24
48
12
24
48
12
24
48
12
24
7.0 to 13.8
14.0 to 27.6
28.0 to 56.0
7.0 to 13.8
14.0 to 27.6
28.0 to 56.0
7.0 to 13.8
14.0 to 27.6
28.0 to 56.0
7.0 to 13.8
14.0 to 27.6
28.0 to 56.0
7.0 to 13.8
14.0 to 27.6
0.07
0.06
0.05
0.11
0.08
0.05
0.16
0.10
0.06
0.25
0.13
0.08
0.40
0.22
0.84
1.44
2.40
1.32
1.92
2.40
1.92
2.40
2.88
3.00
3.12
3.84
4.80
5.28
2100
1.050
37.08
2.53
0.100
25.0
2450
1.240
43.79
3.25
0.130
30.0
2850
1.450
51.21
4.50
0.177
34.0
3200
1.640
57.92
5.62
0.221
38.0
3800
1.920
67.80
7.67
0.302
45.0
MODEL
AFB0912L
AFB0924L
AFB0948L
AFB0912M
AFB0924M
AFB0948M
AFB0912H
AFB0924H
AFB0948H
AFB0912HH
AFB0924HH
AFB0948HH
AFB0912VH
AFB0924VH
& Q CURVE (AT RATED VOLTAGE)
82.5
(3.248)
■P
88.0
(3.465)
* Bearing Type
Ball Bearings
* Material
Impeller & Frame : Plastic (UL 94V-0)
* Lead Wires :
UL 1007 AWG #24 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
* Weight : 99g (3.49 oz)
PART NO.
8- 4.5 0.3
(8- 0.177 0.012)
305.0 10.0
(12.008 0.394)
(
10.0
(0.394)
92.0 0.5
(3.622 0.020)
4.0 0.3
(0.157 0.012)
82.5 0.3
(3.248 0.012)
■ DIMENSIONS
Maximum
Air Flow
Maximum
Air Pressure
Noise
* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.
31
http://www.deltaww.com
AFB
92 x 92 x 25.4 MM SERIES
DRAWING
92.0
0.3
0.012)
0.3
(2-0.157
0.020)
0.3
0.012)
10.0
8-
(0.394)
310.0
(12.205
MODEL
PART NO.
REV. FUNCTION
INLET SIDE
7.5
M
0.2
5.0
0.1
2.5
0
0
82.5
82.5
(3.248)
(3.248)
(
88.4
(3.480)
L
82.5
(3.248)
H
10
4.
09 0
4)
0.3
88.4
(3.480)
4.
HH
VH
(
10.0
VDC
PANEL CUTOUT
88.4
(3.480)
0.4
SH
10
4
11 .4
0)
12.5
mm
(INCH)
88.4
(3.480)
4.
0.5
VDC
UNIT :
0.012)
OUTLET SIDE
15.0
Operating
Voltage
Range
0.3
■ MOUNTING
AFB0912/24X-A
0.6
Rated
Voltage
4.5
0.177
0.394)
& Q CURVE (AT RATED VOLTAGE)
(IN H2O)
Air Pressure
■P
(mm H2O)
* Bearing Type
Ball Bearings
* Material
Impeller & Frame : Plastic (UL 94V-0)
* Lead Wires :
UL 1007 AWG #24 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
* Weight : 120g (4.23 oz)
(8-
10.0
82.5
LABEL
0.020)
2-4.0
0.5
(3.6226
82.5
(3.248
82.5
(3.248)
0.020)
(3.622
0.5
(1.000
0.012)
0.5
25.4
(3.248
92.0
■ DIMENSIONS
0
0.6
0
24.0
1.2
1.8
48.0
2.4
72.0
3.0
96.0
(M3/MIN)
4(4-
(CFM)
4- 4.5
(4- 0.177)
4.5
0.177)
Air Flow
Input
Input
Current Power
Amp
Watt
AFB0912L
-A
-R00/-F00
12
5.0 to 13.8
0.10
1.20
AFB0924L
-A
-R00/-F00
24
14.0 to 26.4
0.08
1.92
AFB0912M
-A
-R00/-F00
12
5.0 to 13.8
0.12
1.44
AFB0924M
-A
-R00/-F00
24
14.0 to 26.4
0.10
2.40
AFB0912H
-A
-R00/-F00
12
5.0 to 13.8
0.21
2.52
AFB0924H
-A
-R00/-F00
24
14.0 to 26.4
0.12
2.88
AFB0912HH
-A
-R00/-F00
12
5.0 to 13.8
0.32
3.84
AFB0924HH
-A
-R00/-F00
24
14.0 to 26.4
0.18
4.32
AFB0912VH
-A
-R00/-F00
12
5.0 to 12.6
0.40
4.80
AFB0924VH
-A
-R00/-F00
24
14.0 to 26.4
0.25
6.00
AFB0912SH
-A
-R00/-F00
12
5.0 to 12.6
0.75
9.00
AFB0924SH
-A
-R00/-F00
24
14.0 to 26.4
0.40
9.60
UNIT:
Speed
Maximum
Air Flow
Maximum
Air Pressure
mm
(INCH)
Noise
R.P.M.
m3 /min
CFM
mmH2O
IN H2O
dB-A
1800
1.055
37.25
2.05
0.080
25.0
2300
1.402
49.51
3.38
0.133
31.5
2800
1.696
59.89
4.86
0.191
37.0
3300
2.060
72.74
6.65
0.262
42.5
3800
2.307
81.47
8.76
0.345
46.0
4800
2.905
102.59
13.35
0.526
53.0
* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.
32
http://www.deltaww.com
Similar pages