Mean Well GE3018-P1J 30w ac-dc interchangeable industrial adaptor Datasheet

30W AC-DC Interchangeable Industrial Adaptor
■ Features
Interchangeable AC plugs (plug kit sold sperately)
Universal AC input / Full range
No load power consumption< 0.075W
Energy efficiency Level Ⅵ
Comply with EISA 2007/DoE and EU ErP
Class Ⅱ power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
LED indicator for power on
2 years warranty
GE30
series
■ Applications
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
■ Description
GE30 is a highly reliable, 30W wall-mounted style single-output green adaptor series, which is compact
and convenient for carry. This product is equipped with an interchangeable AC plug (4 types, including
European type, USA type, U.K. type and Australian type) that makes it very suitable for businessmen to
use in the major countries around the globe. GE30 is a class Ⅱ power unit (without FG), accepting the
input range from 90VAC to 264VAC that it can satisfy the demands for various types of electrical devices.
With the working efficiency up to 87% and the extremely low no-load power consumption below 0.075W,
GE30 is compliant with the latest USA energy regulation EISA 2007/DoE(Level Ⅵ) and EU ErP. The
supreme feature allows the adaptor to save the energy when it is under either the operating mode or the
standby mode. The entire series is approved for international safety regulations; moreover, it adopts the
94V-0 flame retardant plastic case that it can effectively prevent users from electric hazard.
■ Model Encoding
GE 30 12 - P1J
{
P1J: Plug for standard model, 2.1ψ×5. 5ψ×11mm,
C+ tuning fork type
DC plug type
Optional plug type available per request
Output voltage
Output wattage
Series name
File Name:GE30-SPEC 2015-12-09
GE30
30W AC-DC Interchangeable Industrial Adaptor
series
Interchangeable AC plug specifically for GE series
TYPE
ORDER NO.
Australian type
U.K type
European type
US type
Mix four type
AC plug-AU
AC plug-UK
AC plug-EU
AC plug-US
AC plug-MIX
SPECIFICATION
DC VOLTAGE
OUTPUT
Note.2 12V
I I
GE30 I 24-P1J
GE30 I 15
GE30 I 18
GE30 I 24
15V
18V
24V
1.25A
RATED CURRENT
2.5A
2A
1.66A
CURRENT RANGE
0 ~ 2.5A
0 ~ 2A
0 ~ 1.66A
0 ~ 1.25A
RATED POWER (max.)
30W
30W
30W
30W
RIPPLE & NOISE (max.) Note.3 120mVp-p
150mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4 ±3.0%
±3.0%
±3.0%
±3.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
Note.6 ±3.0%
±3.0%
±3.0%
±3.0%
SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC
Note.7 90 ~ 264VAC
VOLTAGE RANGE
135 ~ 370VDC
FREQUENCY RANGE
INPUT
GE30 I 18-P1J
I I
I I
GE30 I 12
I I
I I
I I
GE30 I 15-P1J
I I
SAFETY MODEL NO.
I I
POWER SUPPLY MAIN BODY ORDER NO. GE30 I 12-P1J
4000ms, 100ms, 10ms / 115VAC at full load
47 ~ 63Hz
EFFICIENCY (Typ.)
84%
AC CURRENT
0.7A / 100VAC
INRUSH CURRENT (max.)
COLD START 40A / 100VAC
LEAKAGE CURRENT (max.)
0.25mA / 240VAC
110% ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVERLOAD
PROTECTION
86%
87%
87%
0.4A / 230VAC
80A / 230VAC
OVER VOLTAGE
115% ~ 135% rated output voltage
Protection type : Clamp by zener diode
WORKING TEMP.
-10 ~ +50℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03% / ℃ (0 ~ 30℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 8)
EMC EMISSION
EMC IMMUNITY
LIFE
OTHERS
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
2 years : 100% load 30℃, 8 hours / day
MIL-HDBK-217F (25℃)
MTBF
100Khrs min.
DIMENSION
PACKING
81*43*40.5mm (L*W*H)
134g ; 50pcs / 8.4kg / CARTON
DC OUTPUT PLUG
CONNECTOR CABLE
NOTE
UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug.
File Name:GE30-SPEC 2015-12-09
GE30
30W AC-DC Interchangeable Industrial Adaptor
Derating Curve
series
Static Characteristics
100
90
LOAD (%)
LOAD (%)
100
75
50
80
70
60
50
40
-10
10
20
30
40
50
90
AMBIENT TEMPERATURE (℃)
95
100
115
120
140
160
180
200
220
240
INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification
Unit:mm
36.5
40.5
264
AWM2468 16AWG 1000±50mm for 12V
AWM2468 18AWG 1500±100mm for 15~24V
43
C"+"
11±0.5mm
ID 2.1 x OD 5.5
Outside
81
Inside
Plug Assignment
Standard plug: P1J
P1J
P/N
OUTPUT
CENTER
+
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:GE30-SPEC 2015-12-09
Similar pages