Home > Product Details LDA150W Features Input range LDA10 - 75F (AC85 - 264V) Input range LDA100 - 300W (AC85 - 132V/AC170 - 264V) Rugged PCB type Built-in Inrush Current Protection RoHS Compliant Safety Agency Approvals Complies with DEN-AN UL1950, C-UL recognized, TUV approved UL recognized, TUV approved, CSA certified (LDA10F - LDA150W) EMI Compliance FCC-B CISPR22-B EN55022-B VCCI-B 2 year warranty(refer to Instruction Manual) Input Voltage [V] Output Wattage [W] DC Output [V/A] LDA150W-3 AC 85 - 264 90 3V 30A LDA150W-5 AC 85 - 264 150 5V 30A LDA150W-9 AC 85 - 264 153 9V 17A LDA150W-12 AC 85 - 264 150 12V 12.5A LDA150W-15 AC 85 - 264 150 15V 10A LDA150W-18 AC 85 - 264 153 18V 8.5A LDA150W-24 AC 85 - 264 151.2 24V 6.3A LDA150W24-H AC 85 - 264 151.2 (peak 240) 24V 6.3A (peak 10A) LDA150W-30 AC 85 - 264 150 30V 5A LDA150W-48 AC 85 - 264 144 48V 3A Model Ordering information Rugged PCB type LDA150W LDA 150 1 2 W 3 -5 4 Recommended Noise Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT *3 -O 5 1Series name 2Output wattage 3Autoranging input 4Output voltage 5Optional C :with Coating G :Low leakage current L :with LED R :with Remote ON/OFF S :with Chassis SN :with Chassis & cover Y :with Potentiometer LDA150W-3 LDA150W-5 LDA150W-9 LDA150W-12 LDA150W-15 LDA150W-18 LDA150W-24 LDA150W-24-H LDA150W-30 LDA150W-48 90 150 153 150 150 153 151.2 151.2 150 144 3V 30A 5V 30A 9V 17A 12V 12.5A 15V 10A 18V 8.5A 24V 6.3A 24V 6.3(10)A 30V 5A 48V 3A SPECIFICATIONS MODEL VOLTAGE[V] LDA CURRENT[A] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LDA150W-3 LDA150W-5 LDA150W-9 LDA150W-12 LDA150W-15 LDA150W-18 LDA150W-24 LDA150W-24-H LDA150W-30 LDA150W-48 AC 85 - 132 / 170 - 264 1f 3.6typ (Io=100%) 2.0typ (Io=100%) 47 - 440 75typ 79typ 79typ 82typ 83typ 84typ 85typ 85typ 85typ 82typ 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 9 12 15 18 24 24 30 48 30 30 17 12.5 10 8.5 6.3 6.3(10) 5 3 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max 40max 40max 100max 100max 120max 120max 150max 150max 180max 240max 80max 80max 120max 120max 120max 120max 120max 220max 120max 150max 140max 140max 160max 160max 160max 160max 160max 260max 160max 200max 120max 120max 150max 150max 150max 150max 150max 250max 150max 400max 160max 160max 180max 180max 180max 180max 180max 280max 180max 600max 60max 60max 120max 150max 180max 200max 290max 290max 360max 560max 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 4.5 - 5.5 Fixed ("Y"which can be adjusted the output is available as option :9, 12, 15, 18, 24, 30, 48V t10%) 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5 46.0 - 50.0 xx xx Works over 105% of rating (-H : peak) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 75X37X222mm (WXHXD) /510g max (without chassis and cover) Convection *1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(24V:151.2W). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 ( ) : peak current * Avoid prolonged use under over-load. E-46 * * Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA150W External view LDA Performance data ¡STATIC CHARACTERISTICS (LDA150W-5 ) ¡RISE TIME & FALL TIME (LDA150W-5 ) ¡OVERCURRENT CHARACTERISTICS (LDA150W-5 ) ¡DERATING CURVE E-47