ETC2 LDA150W Rugged pcb type Datasheet

Home > Product Details
LDA150W
Features
Input range LDA10 - 75F (AC85 - 264V)
Input range LDA100 - 300W (AC85 - 132V/AC170 - 264V)
Rugged PCB type
Built-in Inrush Current Protection
RoHS Compliant
Safety Agency Approvals
Complies with DEN-AN
UL1950, C-UL recognized, TUV approved
UL recognized, TUV approved, CSA certified (LDA10F - LDA150W)
EMI Compliance
FCC-B
CISPR22-B
EN55022-B
VCCI-B
2 year warranty(refer to Instruction Manual)
Input
Voltage
[V]
Output
Wattage
[W]
DC
Output
[V/A]
LDA150W-3
AC 85 - 264
90
3V
30A
LDA150W-5
AC 85 - 264
150
5V
30A
LDA150W-9
AC 85 - 264
153
9V
17A
LDA150W-12
AC 85 - 264
150
12V
12.5A
LDA150W-15
AC 85 - 264
150
15V
10A
LDA150W-18
AC 85 - 264
153
18V
8.5A
LDA150W-24
AC 85 - 264
151.2
24V
6.3A
LDA150W24-H
AC 85 - 264
151.2
(peak 240)
24V
6.3A
(peak 10A)
LDA150W-30
AC 85 - 264
150
30V
5A
LDA150W-48
AC 85 - 264
144
48V
3A
Model
Ordering information
Rugged PCB type
LDA150W
LDA 150
1
2
W
3
-5
4
Recommended Noise Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*3
-O
5
1Series name
2Output wattage
3Autoranging input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
L :with LED
R :with Remote ON/OFF
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
LDA150W-3 LDA150W-5 LDA150W-9 LDA150W-12 LDA150W-15 LDA150W-18 LDA150W-24 LDA150W-24-H LDA150W-30 LDA150W-48
90
150
153
150
150
153
151.2
151.2
150
144
3V 30A
5V 30A
9V 17A
12V 12.5A 15V 10A 18V 8.5A 24V 6.3A 24V 6.3(10)A 30V 5A
48V 3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
LDA
CURRENT[A]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A] ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
*1
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C
RIPPLE[mVp-p]
-10 - 0C
0 to +50C
RIPPLE NOISE[mVp-p]
-10 - 0C
TEMPERATURE REGULATION[mV]
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
LDA150W-3 LDA150W-5 LDA150W-9 LDA150W-12 LDA150W-15 LDA150W-18 LDA150W-24 LDA150W-24-H LDA150W-30 LDA150W-48
AC 85 - 132 / 170 - 264 1f
3.6typ (Io=100%)
2.0typ (Io=100%)
47 - 440
75typ
79typ
79typ
82typ
83typ
84typ
85typ
85typ
85typ
82typ
30typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
3
5
9
12
15
18
24
24
30
48
30
30
17
12.5
10
8.5
6.3
6.3(10)
5
3
20max
20max
36max
48max
60max
72max
96max
96max
120max
192max
40max
40max
100max
100max
120max
120max
150max
150max
180max
240max
80max
80max
120max
120max
120max
120max
120max
220max
120max
150max
140max
140max
160max
160max
160max
160max
160max
260max
160max
200max
120max
120max
150max
150max
150max
150max
150max
250max
150max
400max
160max
160max
180max
180max
180max
180max
180max
280max
180max
600max
60max
60max
120max
150max
180max
200max
290max
290max
360max
560max
20max
20max
36max
48max
60max
72max
96max
96max
120max
192max
200max (ACIN 100V, Io=100%)
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%)
2.85 - 3.6 4.5 - 5.5 Fixed ("Y"which can be adjusted the output is available as option :9, 12, 15, 18, 24, 30, 48V t10%)
8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5 46.0 - 50.0
xx
xx
Works over 105% of rating (-H : peak) and recovers automatically
4.00 - 5.25V Works at 115 - 140% of rating
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
-10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
75X37X222mm (WXHXD) /510g max (without chassis and cover)
Convection
*1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated
wattage(24V:151.2W).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*3 ( ) : peak current
* Avoid prolonged use under over-load.
E-46
*
*
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LDA150W
External view
LDA
Performance data
¡STATIC CHARACTERISTICS (LDA150W-5 )
¡RISE TIME & FALL TIME (LDA150W-5 )
¡OVERCURRENT CHARACTERISTICS (LDA150W-5 )
¡DERATING CURVE
E-47