SICK M20S-061A3A120 Multiple light beam safety device Datasheet

Online data sheet
M20S-061A3A120, M20E-061A3A120
M2000 Standard
MULTIPLE LIGHT BEAM SAFETY DEVICES
M20S-061A3A120, M20E-061A3A120 | M2000 Standard
MULTIPLE LIGHT BEAM SAFETY DEVICES
A
B
C
D
E
F
Ordering information
System part
Type
Part no.
Sender
M20S-061A3A120
1016446
Receiver
M20E-061A3A120
1016447
1.) Concerns installation as a replacement part for previous type 2 device in machine: Regarding Machinery Directive
2006/42/EC, Article 1, Paragraph (2a) this type 2 device may only be used as a replacement part for identical PL d / SIL2
devices within the EU if the machine was put into circulation before 2015-05-10. Keep this note with your machine documentation. If the machine is sold on, this note and the information it contains must be passed on to every subsequent buyer. 2.)
Concerns installation on new machines: Due to the amendment to the EN/IEC 61496-1 standard, this type 2 device may only
be installed on new machines up to PL c / SIL1 as of 2015-05-10.
Other models and accessories
www.sick.com/M2000_Standard
Detailed technical data
Features
H
I
J
K
L
M
N
O
P
Q
R
S
T
Scanning range
0 m ... 25 m, configurable
Low scanning range
0 m ... 6 m
Great scanning range
2 m ... 25 m
Number of beams
6
Beam separation or resolution
170 mm
Response time
8 ms
Synchronization
Optical synchronisation
Safety-related parameters
Type
Type 2 (IEC 61496)
Safety integrity level
SIL1 (IEC 61508)
SILCL1 (EN 62061)
Category
Category 2 (EN ISO 13849)
Test rate (internal test)
13 /s (EN ISO 13849) 1)
Maximum demand rate
≤ 8 min⁻¹ (EN ISO 13849) 2)
Performance level
PL c (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour)
6.6 x 10-9 (EN ISO 13849)
TM (mission time)
20 years (EN ISO 13849)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
1)
2)
Internal test. The test rate may not be exceeded if an external test is performed.
Between two requirements on a safety-related response of the device, at least 100 internal or external tests must be carried out.
Functions
Functions
Delivery status
Beam coding
✔
Uncoded
Configurable scanning range
✔
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-06-14 08:06:28
Subject to change without notice
M20S-061A3A120, M20E-061A3A120 | M2000 Standard
MULTIPLE LIGHT BEAM SAFETY DEVICES
Interfaces
System connection
Connection type Hirschmann plug M26, 7-pin
Permitted cable length ≤ 60 m 1)
Permitted cross-section ≥ 1 mm²
Configuration method
Hard wired
Display elements
LEDs
7-segment display
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 2)
1)
2)
Depending on load, power supply and wire cross-section. The technical specifications must be observed.
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Sender
Protection class
III (EN 50178)
Supply voltage VS
24 V DC (19.2 V DC ... 28.8 V DC) 1)
Power consumption
≤ 3.7 W (DC)
Receiver
≤ 5 W (DC)
Safety outputs (OSSD)
Type of output
2 PNP semiconductors, short-circuit protected, cross-circuit monitored 2)
Switching voltage HIGH
24 V DC (VS – 2.25 V DC ... VS)
Switching voltage LOW
≤ 1 V DC
Switching current
≤ 500 mA
1)
The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as
accessories from SICK.
2)
Applies to the voltage range between –30 V and +30 V.
Mechanical data
Housing cross-section
48 mm x 40 mm
Ambient data
Enclosure rating
IP65 (EN 60529)
Ambient operating temperature
0 °C ... +55 °C
Storage temperature
–25 °C ... +70 °C
Air humidity
15 % ... 95 %, Non-condensing
Vibration resistance
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
Shock resistance
10 g, 16 ms (IEC 60068-2-29)
Other information
Wave length
2017-06-14 08:06:28 | Online data sheet

Subject
to change without notice
950 nm
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
3
M20S-061A3A120, M20E-061A3A120 | M2000 Standard
MULTIPLE LIGHT BEAM SAFETY DEVICES
Dimensional drawing (Dimensions in mm (inch))
1.7
8
(0.31)
(1.69)
2
Ø 8.4
48 (1.89)
3
44.4
4
(0.33)
(1.75)
75 (2.95)
68 (2.68)
1
11.9
20
(0.47)
(0.79)
48
5
(1.89)
40
14
L6
L1
A1
(0.41)
S1
3.5
(0.14)
1
10.5
(0.09)
2.2
L5
(1.67)
(0.04)
6
(1.57)
(0.55)
(0.24)
42.3
22.4
25.6
(0.88)
35
22.5
(1.38)
48 (1.89)
76.3 (3.00)
(1.01)
42.6
(0.89)
H
I
J
K
L
M
N
O
P
Q
R
S
T
(0.07)
42.9
L4
L2
L3
A
B
C
D
E
F
(1.68)
6
4
Number
of beams
Beam separation
Resolution
L1
L2
L3
L4
L5
L6
2
500 (19.69)
-
630 (24.80)
697 (27.44)
588 (23.15)
718 (28.27)
655 (25.79)
675 (26.57)
3
400 (15.75)
-
931 (36.65)
998 (39.29)
888 (34.96)
1,019 (40.12)
956 (37.64)
976 (38.43)
4
300 (11.81)
-
989 (38.94)
1,119 (44.06) 1,056 (41.57) 1,076 (42.36)
6
-
170 (6.69)
874 (34.41)
1,004 (39.53)
7
-
170 (6.69)
8
-
116 (4.57)
8
-
170 (6.69)
1,231 (48.46) 1,298 (51.10) 1,189 (46.81) 1,319 (51.93) 1,256 (49.45) 1,275 (50.20)
9
-
170 (6.69)
1,388 (54.65) 1,455 (57.28) 1,346 (52.99) 1,476 (58.11) 1,413 (55.63) 1,433 (56.42)
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
1,031 (40.59) 1,098 (43.23)
916 (36.06)
983 (38.70)
941 (37.05)
960 (37.80)
1,073 (42.24) 1,140 (44.88) 1,031 (40.59) 1,161 (45.71) 1,098 (43.23) 1,118 (44.02)
851 (33.50)
919 (36.18)
809 (31.85)
939 (36.97)
877 (34.53)
896 (35.28)
Online data sheet | 2017-06-14 08:06:28
Subject to change without notice
M20S-061A3A120, M20E-061A3A120 | M2000 Standard
MULTIPLE LIGHT BEAM SAFETY DEVICES
Connection diagram
+24 V DC
1)
x
s
r
+24 V
+24 V
GND
GND
Test
OSSD1
4
HRANGE
OSSD2
5
Sel1
Sel1
Sel2
Sel2
1
2
3
6
y
k1 k2
x
1
y
z
2
k1
3
4
k2
5
z
6
Shield
Shield
S1
M2000
S33 S11 S12 S31 A1
k1
13 23 31
UE48-2OS2D2
S34 S35 S21 S22 A2 14 24 32
k2
2)
K1
K2
0V
3) PELV
E119932/01/2017-06-12
Task
Connection of an M2000 Standard multi-beam photoelectric safety switch to UE48-2OS.
Operating mode: with restart interlock and external device monitoring.
Function
When the light path is clear, the OSSD1 and OSSD2 outputs are live. The system is ready to switch on if K1 and K2 are de-energized. By pressing S1 (button is pressed and released), the UE48-2OS is energized and its 13 - 14 and 23 - 24 contacts activate K1
and K2. On interruption of one of the light beams, the UE48-2OS is de-energized by the OSSD1 and OSSD2 outputs and K1 and K2
are deactivated.
Fault analysis
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The incorrect functioning of one of the
K1 or K2 contactors will be detected and does not result in the loss of the shutdown function. Jamming of the S1 button will prevent the UE48-2OS from enabling.
Comments
1)
Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, the integration must be dual-channel (x/y paths). Single-channel integration in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
2)
The external device monitoring is only static.
3)
PELV as required in EN 60204-1 / 6.4
The related operating instructions for the integrated devices must be observed.
2017-06-14 08:06:28 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
5
M20S-061A3A120, M20E-061A3A120 | M2000 Standard
MULTIPLE LIGHT BEAM SAFETY DEVICES
A
B
C
D
E
F
Recommended accessories
Other models and accessories
www.sick.com/M2000_Standard
Brief description
Type
Part no.
BEF-3WNGBAST4
7021352
4 pieces, Mounting kit 6, side bracket, rotatable, Zinc diecast
BEF-1SHABAZN4
2019506
4 pieces, Omega bracket, rotatable, fixable with only one screw, for mounting on the
swivel mount
BEF-2SMMEAAL4
2044847
4 pieces, Mounting kit 2, rotatable, swivel mount, Polyamide PA6
BEF-2SMMEAKU4
2019659
AR60
1015741
AR60 adapter, 48x40
4032461
AR60 adapter,
48x40, PU3H
4056731
Mounting brackets and plates
4 pieces, Mounting kit 1, mounting bracket, rigid, L-shaped, including fixing screws
and washers
Terminal and alignment brackets
Alignment aids
H
I
J
K
L
M
N
O
P
Q
R
S
T
Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into
the beam!
Adapter AR60 for housing cross-section 48 mm x 40 mm
Adapter AR60 for housing cross-section 48 mm x 40 mm in PU3H device column
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-06-14 08:06:28
Subject to change without notice
Online data sheet
SICK at a glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”
Worldwide presence:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com
Similar pages