ACDC 36100 Watts AEB Series xppower.com • CEC2008 & EISA2007 Compliant • Low Profile • Single Outputs from 5 V to 48 V • High Power Density • Universal Input • China Compulsory Certification (CCC) Qualified • 3 Year Warranty Specification Input General • 90-264 VAC • 47-63 Hz • AEB36: 1.00 A max AEB45: 1.20 A max AEB70: 1.50 A max AEB100: 1.85 A max Inrush Current • AEB36: 60 A max at 240 VAC AEB45: 70 A max at 240 VAC AEB70: 80 A max at 240 VAC AEB100: 120 A max at 240 VAC Power Factor • EN61000-3-2, class A Earth Leakage Current • <3.5 mA (AEB45/70/100) Input Protection • Fitted with an internal fuse AEB36 T1A/250 VAC, AEB45/70/100 T2A/250 VAC No Load Input Power • <0.5 W Input Voltage Input Frequency Input Current Efficiency Energy Efficiency Isolation Switching Frequency Power Density MTBF Output Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time • • • • • • Drift Line Regulation Load Regulation Ripple & Noise • • • • Transient Response • Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient • • • • See tables ±2%, set at 60% load No minimum load required 3 s max 20 ms AEB36/45/70: 8 ms at 115 VAC AEB100: 20 ms at 115 VAC ±0.05% ±1% See tables 1% pk-pk max, 20 MHz bandwidth, (see note 2) 5% max deviation, recovery to within 1% in 500 µs for a 25% load change Typical 125% max, latching Trip & restart mode (hiccup mode) Continuous ±0.04%/°C • See tables • AEB70: Level V All other models: Level IV • AEB36: 3000 VAC Input to Output AEB45/70/100: 3000 VAC Input to Output, 1500 VAC Input to Ground. Negative output is connected to ground. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number • AEB36: 60 kHz typical, AEB45: 100 kHz typical, AEB70: 65 kHz typical, AEB100: 80 kHz typical PFC converter 45 kHz typical main converter • AEB36: 5.34 W/in3, AEB45: 3.81 W/in3, AEB70: 4.92 W/in3, AEB100: 4.45 W/in3 • AEB36: >360 kHrs, AEB45: >300 kHrs, AEB70: >200 kHrs, AEB100: >150 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • AEB36/45/70: 0 ˚C to +60 °C derate linearly from 100% load at +40 °C to 60%, load at +60 °C, AEB100: 0 °C to +60 °C derate linearly from 100% load at +40 °C to 50% load at +60 °C Storage Temperature • -20 °C to +85 °C Operating Humidity • 93% RH, non-condensing EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity • • • • Radiated Immunity EFT/Burst Surge • • • Conducted Immunity Magnetic Field Dips & Interruptions • • • Safety Approvals • EN55022, Level B conducted & radiated EN61000-3-2 Class A EN61000-3-3 EN61000-4-2 Level 2 (contact) Perf Criteria A EN61000-4-2 Level 3 (air) Perf Criteria A EN61000-4-3, 3 V/m Perf Criteria A EN61000-4-4, level 2 Perf Criteria A EN61000-4-5, installation class 3, Perf Criteria B EN61000-4-6, Level 2 Perf Criteria A EN61000-4-8, 3 A/m Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B EN60950-1:2006+A11, UL/cUL60950-1, China Compulsory Certification (CCC) qualified (AEB36/70 only) AEB36 Output Power 20 27 30 32 36 36 36 36 W W W W W W W W Output Voltage 5.0 9.0 12.0 13.5 15.0 18.0 24.0 48.0 V V V V V V V V Output Current 4.00 3.00 2.50 2.40 2.40 2.00 1.50 0.75 A A A A A A A A Load Regulation(1) Efficiency(3) ±6% ±5% ±5% ±5% ±3% ±2% ±2% ±2% 73% 77% 78% 80% 80% 81% 81% 83% Model Number AEB36US05 AEB36US09 AEB36US12 AEB36US13 AEB36US15 AEB36US18 AEB36US24 AEB36US48 Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. 3. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. AEB45 Output Power 45 45 45 45 45 48 W W W W W W Output Voltage 12.0 15.0 18.0 19.0 24.0 48.0 V V V V V V Output Current 3.75 3.00 2.50 2.37 1.88 1.00 A A A A A A Load Regulation(1) Efficiency(4) Model Number(3) ±3% ±3% ±2% ±2% ±2% ±2% 84% 85% 85% 85% 86% 87% AEB45US12 AEB45US15 AEB45US18 AEB45US19 AEB45US24 AEB45US48 Load Regulation(1) Efficiency(5) Model Number(3) ±5% ±3% ±2% ±2% ±2% ±2% 82% 84% 84% 84% 85% 87% Notes 1. 2. 3. 4. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. AEB70 Output Power 66 69 70 72 72 72 W W W W W W Output Voltage 12.0 15.0 18.0 19.0 24.0 48.0 V V V V V V Output Current 5.50 4.60 3.90 3.70 3.00 1.50 A A A A A A AEB70US12 AEB70US15(4) AEB70US18(4) AEB70US19(4) AEB70US24(4) AEB70US48(4) Notes 1. 2. 3. 4. 5. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number. Energy efficiency level V. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. AEB100 Output Power 100 100 100 100 100 W W W W W Output Voltage 12.0 12.5 15.0 24.0 48.0 V V V V V Output Current 8.34 8.00 6.67 4.17 2.08 A A A A A Load Regulation(1) Efficiency(4) Model Number(3) ±4% ±4% ±4% ±2% ±2% 85% 85% 85% 85% 85% AEB100PS12 AEB100PS125 AEB100PS15 AEB100PS24 AEB100PS48 Notes 1. 2. 3. 4. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. ACDC AEB36100 Models and Ratings ACDC AEB36/45 Mechanical Details AEB36 Power Cord Order Part: UK - UK-MAINS-8 European - EU-MAINS-8 US - US-MAINS-8 Cable length: 48” ±2” (1220 mm ±50 mm) 1.97 (50.0) 4.33 (110.0) IEC320-C8 0.47 (12.00) 0.79 (20.0) Notes 1. 2. 3. 4. 5. 6. All dimensions shown in inches (mm). Weight: 0.42 lbs (190 g) approx. Tolerance is ±0.02 (±0.5) maximum, except output cable length. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center + and outer shell - polarity. Optional output connectors available, contact sales for details. Length of mains lead: 76 inches (1930 mm) approx AEB45 Cable length: 48” ±2” (1220 mm ±50 mm) Power Cord Order Part: UK - UK-MAINS-IEC European - EU-MAINS-IEC US - US-MAINS-IEC 2.05 (52.0) 4.72 (120.0) IEC320-C14 1.22 (31.0) Notes 1. 2. 3. 4. 5. 6. All dimensions shown in inches (mm). Weight: 0.62 lbs (280 g) approx. Tolerance is ±0.02 (±0.5) maximum, except output cable length. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center + and outer shell - polarity. Optional output connectors available, contact sales for details. Length of mains lead: 76 inches (1930 mm) approx 0.47 (12.00) AEB70 Cable length: 48” ±2” (1220 mm ±50 mm) Power Cord Order Part: UK - UK-MAINS-IEC European - EU-MAINS-IEC US - US-MAINS-IEC 2.28 (58.0) 0.47 (12.00) 5.20 (132.0) IEC320-C14 1.20 (30.5) Notes 1. 2. 3. 4. 5. 6. All dimensions shown in inches (mm). Weight: 0.76 lbs (345 g) approx. Tolerance is ±0.02 (±0.5) maximum, except output cable length. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center + and outer shell - polarity. Optional output connectors available, contact sales for details. Length of mains lead: 76 inches (1930 mm) approx Cable length: 48” ±2” (1220 mm ±50 mm) AEB100 Power Cord Order Part: UK - UK-MAINS-IEC European - EU-MAINS-IEC US - US-MAINS-IEC 2.76 (70.0) 5.90 (150.0) 0.47 (12.00) IEC320-C14 1.38 (35.0) Notes 1. 2. 3. 4. 5. 6. All dimensions shown in inches (mm). Weight: 1.36 lbs (600 g) approx. Tolerance is ±0.02 (±0.5) maximum, except output cable length. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center + and outer shell - polarity. Optional output connectors available, contact sales for details. Length of mains lead: 76 inches (1930 mm) approx 21-Jan-11 ACDC AEB70/100 Mechanical Details