30 August 2012 Specification for LC band pass filter: LC 120.0-3.0/03 1. General 1.1. Package: 1.2. 1.3. 1.4. 1.5. Type name: Number of poles: Operating temperature range ( OTR ): Storage temperature range: 2. Electric values 2.1. Nominal centre frequency fo: 2.1.1. Center frequency shift in OTR : 2.2. 2.2.1. 2.2.2. 2.2.3. 2.2.4. LC 120.0-3.0/03 3 -20°C to +70°C -45°C to +85°C 120.0 MHz 13 kHz / °C typical Pass band Centre frequency fc at +25°C: Bandwidth at 3 dB: Ripple in pass band: Insertion loss: typical at -20°C / +25°C / +70 °C: 2.2.5. Return loss at fo: 120.0 MHz ± 300 kHz < 4.0 MHz and > 3.0 MHz Gaussian ( no ripple peak to peak ) < 10.0 dB ( in OTR ) 6.5dB / 7.5dB / 8.5dB > 12 dB 2.3. 2.3.1. 2.3.2. 2.3.3. 2.3.4. Stop band Bandwidth at 10 dB: Bandwidth at 60 dB: Bandwidth at 80 dB: Alternate attenuation: < 6.5 MHz and > 5.5 MHz < 50 MHz < 105 MHz > 60 dB in the range 145….800 MHz 2.4. 2.5. Terminating impedance ( input and output ): Maximum input power level: 50 // 0 pF +20 dBm 3. Marking: OEM marking on demand see marking instruction 4. Environment conditions: Corresponding to Vectron standard CF001 ______________________________________________________________________________________ Edited by: date: ______________________________ name: _______________________________