Click on Series name for product info on aimtec.com Series AMER120C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter FEATURES: Models Single output • AC-DC Constant Current or Constant Voltage LED Driver • Input range 90-305VAC/47-440Hz • High Efficiency up to 88% • Operating temperature -40 to 85°C • Dimmable via resistive / 0-10Vdc / PWM • 5 Years Limited Warranty • • • • • Max Output Power (W)① Output Voltage Range (V)③ Output Current (A)③ Input Voltage (VAC/Hz) Input Voltage (VDC) 36-50 0-2.5 90-305/47-440 130-430 AMER120C-36340AZ 122.4 24-36 0-3.4 90-305/47-440 130-430 AMER120C-24500AZ 120 12-24 0-5 90-305/47-440 130-430 Model AMER120C-50250AZ 125 Over Temperature Protection Over Current Protection Waterproof Case rated IP68 Power Factor Correction Short Circuit Protection Mode of Operation Efficiency (%) 115 230 277 87 87 87 87 85 88 88 88 88 86 86 88 88 88 87 VAC Constant Current Constant Voltage② Constant Current Constant Voltage② Constant Current VAC VAC Constant Voltage② 86 86 87 the maximum output power will permanently damage the converter. ② The dimming feature is not supported when units are used in Constant Voltage mode only. ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires. (add “-NA” to part number when ordering) NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMER120C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. ① Exceeding Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current Power factor External fuse Start-up time www.aimtec.com F 052.1e R3.D Conditions Typical 115 VAC 230 VAC 277 VAC 115 VAC 230 VAC 277 VAC I/O I/FG, O/FG 115 VAC 230 VAC 277 VAC Recommended slow blow type 0.98 0.94 0.92 3 900 Tel: +1 514 620 2722 1 of 6 Maximum 1800 800 700 45 60 70 0.25 3.5 Units mA mA mA A A A mA mA A ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Output Specifications Parameters Conditions Typical Maximum Conditions Typical Rated 500VDC >1000 Current accuracy ±3 Line regulation (LL-HL) ±2 Load regulation 0-100% load ±3 Ripple & Noise* 150 Hold-up time 80 Current adjustment range 100-10 ④ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. Isolation Specifications Parameters Tested voltage Isolation resistance I/O I/FG O/FG General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF 3sec Typical Detect transformer temperature With derating over 55 oC ≧105 ≧105 Auto recovery 125 Refer to model application % % % mV p-p ms % Units 3750 2000 500 Conditions Units VAC VAC VAC MΩ Maximum Units 100 C C o C o C % / oC 125 KHz % % o o -40 to +95 ±0.02 Free air convection Non condensing 20~95 Aluminum Epoxy (IP68 rated) UL1015 18AWG Input & 14AWG output *20CM 900 181.00 x 59.00 x 47.00 mm (7.13 x 2.32 x 1.85 inches) >400,000 hrs (MIL-HDBK-217F at t=+25°C) % RH g Safety Specifications Parameters Standards www.aimtec.com F 052.1e R3.D Meets UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimensions Derating Free Air Convection 55 º C 100 80 Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 80 85 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 3 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimming Performance AMER120C-24500AZ www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 4 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter AMER120C-36340AZ www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 5 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter AMER120C-50250AZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 6 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only