Vishay NTCASCWE3472G Ntc thermistors, screw threaded sensor Datasheet

NTCASCWE3
www.vishay.com
Vishay BCcomponents
NTC Thermistors, Screw Threaded Sensors
FEATURES
• Easy mounting with screw
• Rugged construction
• UL recognized, file E148885
(UL category XGPU2)
• Material categorization:
for definitions of compliance please see
www.vishay.com/doc?99912
APPLICATIONS
• Temperature measurement, sensing and control
• Suitable for surface temperature applications, especially
when a good electrical insulation and a good thermal
contact with the chassis is required
DESCRIPTION
QUICK REFERENCE DATA
PARAMETER
VALUE
UNIT
The thermistors are made of NTC ceramic material reflow
soldered between two solid tinned copper wires or low
thermal conducting 0.5 mm solid tinned nickel wires and
potted in the head of passivated aluminum (size M4).
Resistance value at 25 °C
1K to 470K

Tolerance on R25-value
± 1, ± 2, ± 5
%
PACKAGING
B25/85-value
3528 to 4570
K
Tolerance on B25/85-value
± 0.5 to ± 2.5
%
The thermistors are packed in cardboard boxes; the
smallest packaging quantity is 100 units.
DESIGN-IN SUPPORT
Operating temperature range at:
Zero dissipation
-25 to +100
Maximum power dissipation
°C
0 to +55
For complete Curve Computation, visit:
www.vishay.com/thermistors/ntc-curve-list/
MARKING
 23
mW/K
Maximum power dissipation
500
mW
Thermal time constant (1)
 7.5
s
Min. dielectric withstanding
voltage between terminals and
Al case
1500
VAC
By means of a washer and M4 nut supplied with the device
or in a threaded screw hole. Applied torque shall not exceed
1.2 Nm. Leads to be soldered or crimped.
Insulation resistance between
terminals and Al case
min. 100
M
DIMENSIONS in millimeters
 1.5
g
Dissipation factor (1)
Weight
4 digits marking indicating resistance value and tolerance in
accordance with the information in Electrical Data and
Ordering Information table.
MOUNTING
Notes
• Other R25-values and tolerances are available upon request
• Insulated leads available upon request
(1) Measured with screw mounted on an aluminum heatsink of
100 cm2, thickness 1.5 mm, in still air at Tamb = +25 °C
5.5
min.
Ød
M4
37 ± 3
8 ± 0.1
6.7
max.
8
max.
Component outline
ELECTRICAL DATA AND ORDERING INFORMATION
R25
()
1000
2200
4700
4700
4700
10 000
10 000
10 000
12 000
15 000
47 000
100 000
100 000
100 000
150 000
470 000
R25-TOL.
(± %)
5
5
1
2
5
1
2
5
5
5
5
1
2
5
5
5
Revision: 20-Mar-17
B25/85
(K)
3528
3977
3977
3977
3977
3977
3977
3977
3740
3740
4090
4190
4190
4190
4370
4570
B25/85-TOL.
(± %)
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2
LEADS DIAMETER Ø d
(mm)
0.6
0.6
0.5
0.5
0.6
0.5
0.5
0.6
0.6
0.6
0.6
0.5
0.5
0.6
0.6
0.6
SAP MATERIAL AND
ORDERING NUMBER
NTCASCWE3102J
NTCASCWE3222J
NTCASCWE3472F
NTCASCWE3472G
NTCASCWE3472J
NTCASCWE3103F
NTCASCWE3103G
NTCASCWE3103J
NTCASCWE3123J
NTCASCWE3153J
NTCASCWE3473J
NTCASCWE3104F
NTCASCWE3104G
NTCASCWE3104J
NTCASCWE3154J
NTCASCWE3474J
MARKING CODE
102J
222J
472F
472G
472J
103F
103G
103J
123J
153J
473J
104F
104G
104J
154J
474J
Document Number: 29065
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer

ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for