EABS1U THRU EABS6U SINGLE PHASE 1.0AMP SUPER FAST GLASS PASSIVATED BRIDGE RECTIFIER Features Glass passivated die construction Low forward voltage drop High current capability High surge current capability Designed for surface mount application Plastic material-UL flammability 94V-0 · · · · · · ABS 0.165(4.2) 0.150(3.8) 0.010(0.25) 0.006(0.15) 0.268(6.8) 0.236(6.0) 0.268(6.8) 0.236(6.0) 0.181(4.6) 0.165(4.2) Mechanical Data · Case: SOPA-4, molded plastic ABS · Terminals: plated leads solderable per 0.032(0.7) 0.024(0.5) MIL-STD-202, Method 208 MAX 0.0078(0.2) · Polarity: as marked on case · Mounting position: Any · Marking: type number 0.209(5.3) 0.189(4.8) 0.058(1.5) 0.046(1.2) Dimensions in inches and (millimeters) Maximum Ratings and Electrical Characteristics Rating at 25℃ ambient temperature unless otherwise specified. Single Phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. TYPE NUMBER SYMBOL EABS1U EABS2U EABS4U EABS6U UNITS 100 200 400 600 V 70 140 280 420 V VRRM Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage VRWM RMS Reverse Voltage VRMS VDC Average Rectified Output Current @TA =40℃ IO 1.0 A Non-Repetitive Peak Forward Surge Current 8.3ms Single half sine-wave superimposed on rated load (JEDEC Method) IFSM 35 A Forward Voltage per element VFM @IF=1.0A Maximum Reverse Recovery Time (Note 1) Peak Reverse Current At Rated DC Blocking Voltage @TA =25℃ @TA =125 ℃ Typical Thermal Resistance per leg Operating and Storage Temperature Range Note: 0.95 Trr 1.25 1.7 35 ns IR 5.0 500 uA RθJA 62.5 RθJL 25 TJ,TSTG -55to+150 ℃/W ℃ 1.Reverse Recovery Test Conditions:IF=0.5A,IR=1.0A,IRR=0.25A. version:01 V 1 of 2 www.dyelec.com EABS1U THRU EABS6U FIG.2 TYPICAL FORWARD CHARACTERISTICS FIG.1 FORWARD CURRENT DERATING CURVE AVERAGE FORWARD CURRENT (A) 1.0 0.8 0.6 0.4 SINGLE PHASE HALF WAVE 60Hz RESISTIVE OR INDUCTIVE LOAD 0.2 0.00 100 50 150 AMBIENT TEMPERATURE ( oC) INSTANTANEOUS FORWARD CURRENT,(A) 10 1.2 100V-200V 400V 600V 1.0 0.1 T A=25 ℃ PULSE WIDTH:300us 2% DUTY CYCLE 0.01 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 FIG. 4 TYPICAL REVERSE CHARACTERISTICS FIG.3 MXIMUM NON-REPETITIVE 100 50 40 30 20 SINGLE HALF-SINE-WAVE (JEDEC METHOD) 10 0 1 2 5 10 20 50 100 NUMBER OF CYCLES AT 60 Hz INSTANTANEOUS REVERSE CURRENT (uA) PEAK FORWARD SURGE CURRENT (A) FORWARD VOLTAGE (V) TA=125℃ 10 1 TA=75 ℃ 0.1 TA=25 ℃ 0.01 0 20 40 60 80 100 120 PERCENT OF RATED PEAK REVERSE VOLYAGE(%) version:01 2 of 2 www.dyelec.com 140