SICK CLV690-0010 Bar code scanner Datasheet

Online data sheet
CLV690-0010
CLV69x
BAR CODE SCANNERS
CLV690-0010 | CLV69x
BAR CODE SCANNERS
A
B
C
D
E
F
Ordering information
Type
Part no.
CLV690-0010
1056614
Other models and accessories
www.sick.com/CLV69x
Detailed technical data
Features
H
I
J
K
L
M
N
O
P
Q
R
S
T
Version
Standard Density
Connection type
Depending on the cloning plug used
Reading field
Front
Scanner design
Line scanner
Focus
Auto focus (alternative: dynamic focus control)
No. of distance configurations
≤8
Focus adjustment time
≤ 20 ms
Focus trigger source
Data interface / switching inputs
Light source
Visible red light (660 nm)
MTBF
100,000 h
Laser class
2 (IEC 60825-1 (2007-3), EN 60825-1 (2008-05))
Aperture angle
≤ 60°
Scanning frequency
400 Hz ... 1,200 Hz
Code resolution
0.25 mm ... 1 mm
Reading distance
500 mm ... 2,100 mm 1)
Heating
No
1)
For details see reading field diagram.
Performance
Bar code types
Interleaved 2 of 5, all current code types, Codabar, Code 128, Code 39, Code 93, GS1-128 /
EAN 128, UPC / GTIN / EAN
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 20 (Standard decoder)
1 ... 6 (SMART decoder)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
5,000
No. of multiple readings
1 ... 100
2
IDENTIFICATION SOLUTIONS | SICK
Online data sheet | 2017-03-21 14:30:08
Subject to change without notice
CLV690-0010 | CLV69x
BAR CODE SCANNERS
Interfaces
✔
Ethernet TCP/IP
Remark Only with cloning plug I/O, CAN IN/OUT or CAN Redundant
Function Host, AUX
Data transmission rate 10/100 MBit/s
✔
PROFINET
Remark Only with cloning plug I/O, CAN IN/OUT or CAN Redundant
Function PROFINET Dual Port (optional via external connection module CDF600-2)
✔
EtherNet/IP™
Remark Only with cloning plug I/O, CAN IN/OUT or CAN Redundant
Data transmission rate 10/100 MBit/s
✔, RS-232, RS-422, RS-485
Serial
Remark Only with cloning plug D-Sub and Ethernet
Function Host, AUX (only RS-232)
Data transmission rate 0.3 kBaud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232)
✔
CAN
Function SICK CAN sensor network (Master/Slave, Multiplexer/Server)
Data transmission rate 20 kbit/s ... 1 Mbit/s
✔
PROFIBUS DP
Type of fieldbus integration Optional over external fieldbus module CDF600-2
✔
DeviceNet™
Type of fieldbus integration Optional via external connection module CDM + CMF
Switching inputs
6 (“Sensor 1” ... “Sensor 6”)
Switching outputs
4 (“Result 1” ... “Result 4”)
Reading pulse
Switching inputs, serial interface, auto pulse, CAN
Optical indicators
6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs))
Operating elements
2 buttons
Parameter storage
Integrated in cloning plug
Configuration software
SOPAS ET
Mechanics/electronics
Electrical connection
Depending on the cloning plug used
Operating voltage
18 V DC ... 30 V DC
Power consumption
15 W
Housing
Aluminum die cast
Housing color
Light blue (RAL 5012)
Front screen
Plastic
Enclosure rating
IP65 (EN 60529/A1 (2002-02))
Electrical safety
As per UL 60950-1 certification
Weight
1,500 g
Dimensions (L x W x H)
117 mm x 117 mm x 94 mm
2017-03-21 14:30:08 | Online data sheet

Subject
to change without notice
IDENTIFICATION SOLUTIONS | SICK
3
CLV690-0010 | CLV69x
BAR CODE SCANNERS
Electromagnetic compatibility (EMC)
EN 61000-6-4 (2007-01) + A1 (2011)
EN 61000-6-2 (2005-08)
Vibration resistance
EN 60068-2-6 (2008-02)
Shock resistance
EN 60068-2-27 (2009-05)
Ambient operating temperature
0 °C ... +40 °C
Storage temperature
–20 °C ... +70 °C
Permissible relative humidity
90 %, Non-condensing
Ambient light immunity
2,000 lx, on bar code
General notes
Note on use
Standard device with front reading window made of plastic designed for the food industry
Classifications
ECl@ss 5.0
27280102
ECl@ss 5.1.4
27280102
ECl@ss 6.0
27280102
ECl@ss 6.2
27280102
ECl@ss 7.0
27280102
ECl@ss 8.0
27280102
ECl@ss 8.1
27280102
ECl@ss 9.0
27280102
ETIM 5.0
EC002550
ETIM 6.0
EC002550
UNSPSC 16.0901
43211701
Dimensional drawing (Dimensions in mm (inch))
37
26
(1.02)
31
(1.22)
30
21
(.83)
(1.05) (1.18)
26.7
35
(1.38)
12
43
(1.69)
(.47)
max. Einschrasubtiefe 7 mm
max. screw-in depth 7 mm
(.96)
24.5
44.2 (1.74)
32 (1.26)
14
(.55)
(1.46)
59 ( 2.32)
1
58 (2.28)
114 (4.49)
116 (4.57)
1 (.04)
56 (2.2)
57 (2.24)
[%]
100
LINK TX
Teach-in
Ressult
Auto-Setup
Laser
Read Diagn
Adjusting
Data
User defined
CAN
Ready
17.7 (.07)
2 (.08)
32.5
°
1.3 (.05)
73.5 (2.89)
64.5°
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ambient data
32°
A
B
C
D
E
F
① M6 blind tapped holes, 7 mm deep (2 x), for mounting
4
IDENTIFICATION SOLUTIONS | SICK
Online data sheet | 2017-03-21 14:30:08
Subject to change without notice
CLV690-0010 | CLV69x
BAR CODE SCANNERS
Reading field diagram
Reading field height in mm (inch)
600
(23.62)
400
(15.75)
200
(7.87)
a
b
c
0
–200
(–7.87)
–400
(–15.75)
–600
(–23.62)
400
700
1,000
1,300
1,600
1,900
2,200
(15.75)
(27.56)
(39.37)
(51.18) (62.99)
(74.8)
(86.61)
Reading distance in mm (inch)
Resolution
a: 0.30 mm (11.8 mil)
b: 0.35 mm (13.8 mil)
c: 0.50 mm (19.7 mil)
Recommended accessories
Other models and accessories
www.sick.com/CLV69x
Brief description
Type
Part no.
Quick release
2016110
Mounting bracket
2013824
Connection device basic for connecting one sensor with 2 A fuse, 5 cable glands and
RS-232 interface to sensor via M12, 17-pin female connector, all outputs available on
screw/spring-loaded terminals.
CDB650-204
1064114
Fieldbus proxy/gateway for connecting identification sensors to PROFIBUS-DP networks
(PROFIBUS interface: 2 x M12, male connector/female connector, 5-pin)
CDF600-2100
1058965
Fieldbus proxy/gateway for connecting one identification sensor to PROFINET-IO networks (interface 2 x M12, female connector/female connector, 4-pin)
CDF600-2200
1062460
Modular connection module for one sensor, 2 A fuse
CDM420-0006
1058634
Connection cable
(male connector female connector)
6053230
Terminal and alignment brackets
Quick-action lock system, mounting hardware included
Mounting brackets and plates
Simple mounting bracket
Modules
Plug connectors and cables
Head A: female connector, M12, 17-pin, straight, A-coded
Head B: male connector, M12, 17-pin, straight, A-coded
Cable: Power, serial, CAN, digital I/Os, drag chain use, suitable for 2 A, suitable for refrigeration, shielded, 2 m
2017-03-21 14:30:08 | Online data sheet

Subject
to change without notice
IDENTIFICATION SOLUTIONS | SICK
5
CLV690-0010 | CLV69x
BAR CODE SCANNERS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Brief description
6
Type
Part no.
Head A: female connector, M12, 17-pin, straight
Head B: male connector, D-Sub-HD, 15-pin, straight
Cable: Power, serial, CAN, digital I/Os, shielded, 2 m
Connection cable
(male connector female connector)
2055419
Head A: female connector, M12, 17-pin, straight, A-coded
Head B: male connector, M12, 17-pin, straight, A-coded
Cable: Power, serial, CAN, digital I/Os, suitable for 2 A, drag chain use, shielded, 2 m
Connection cable
(male connector female connector)
6052286
Head A: male connector, M12, 4-pin, straight, D-coded
Head B: male connector, RJ45, 8-pin, straight
Cable: Ethernet, drag chain use, PUR, shielded, 2 m
SSL-2J04-G02ME
6034414
Head A: male connector, M12, 17-pin
Male connector, M12, 5-pin
Female connector, M12, 4-pin
Cable: Power, Ethernet, serial, CAN
Plug housing I/O, Ethernet
Cloning plug
2062452
Head A: Female connector (AUX), M12, 5-pin
Female connector, M12, 5-pin
Male connector, M12, 5-pin
Cable: Power, CAN
Plug housing CAN IN/OUT
Cloning plug
2062453
Head A: male connector, D-Sub-HD, 15-pin
Female connector, D-Sub-HD, 15-pin
Cable: Power, serial, CAN, digital I/Os
Plug housing
Cloning plug
2062450
Head A: male connector, M12, 5-pin
Head B: female connector, M12, 5-pin
Cable: Power, CAN, Ethernet
Plug housing CAN IN/OUT Ethernet
Cloning plug
2074708
IDENTIFICATION SOLUTIONS | SICK
Online data sheet | 2017-03-21 14:30:08
Subject to change without notice
Online data sheet
SICK at a glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”
Worldwide presence:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com
Similar pages