Online data sheet EXS-12D6803B020, EXE-12D6803B020 deTec4 Core Ex SAFETY LIGHT CURTAINS EXS-12D6803B020, EXE-12D6803B020 | deTec4 Core Ex SAFETY LIGHT CURTAINS A B C D E F H I J K L M N O P Q R S T Ordering information System part Type Part no. Sender EXS-12D6803B020 1068416 Receiver EXE-12D6803B020 1068415 Included with delivery with every device: 1 system connecting cable with flying leads 30 m in length. Other models and accessories www.sick.com/deTec4_Core_Ex Detailed technical data Features System part Sender/receiver pair in explosion-proof enclosure Resolution 30 mm Protective field height 1,500 mm Scanning range 0 m ... 8 m Response time 13 ms Synchronization Optical synchronisation Safety-related parameters Type Type 4 (IEC 61496) Safety integrity level SIL3 (IEC 61508) SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 3,7 x 10-9 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state. Interfaces System connection Connection type Male connector M12, 5-pin Permitted cable length ≤ 50 m Status display LEDs Fieldbus, industrial network Integration via Flexi Soft safety controller CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus TCP, PROFIBUS DP, PROFINET 1) 1) 2 For further information on Flexi Soft, please see sens:Control – safe control solutions product catalog or -> www.sick.com/FlexiSoft. OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2016-07-04 20:20:08 Subject to change without notice EXS-12D6803B020, EXE-12D6803B020 | deTec4 Core Ex SAFETY LIGHT CURTAINS Electrical data Protection class III (EN 50178) Supply voltage VS 24 V DC (19.2 V DC ... 28.8 V DC) Ripple ≤ 10 % 1) Power consumption typical 2.4 W (DC) / 1.2 W (DC) (depending on type) Safety outputs (OSSD) Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 2) Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS) Switching voltage LOW ≤ 2 V DC Switching current ≤ 300 mA 1) 2) Within the limits of VS. Applies to the voltage range between –30 V and +30 V. Mechanical data Housing cross-section (incl. system connection) 161.8 mm x 142.1 mm Weight 44.025 kg (± 50 g) 44.015 kg (± 50 g) (depending on type) Ambient data Enclosure rating IP 66 (EN 60529) Ambient operating temperature –20 °C ... +55 °C Storage temperature –30 °C ... +70 °C Air humidity 15 % ... 95 %, Non-condensing Vibration resistance 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Shock resistance 10 g, 16 ms (EN 60068-2-29) Other information Wave length 2016-07-04 20:20:08 | Online data sheet Subject to change without notice 850 nm OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3 EXS-12D6803B020, EXE-12D6803B020 | deTec4 Core Ex SAFETY LIGHT CURTAINS 50.8 (2.00) deTec4 Core Ex, 1,500 mm 161.8 58.7 67.5 (6.37) (2.31) (2.66) 89.6 (3.53) 44.5 9.5 (0.37) 6.4 77 (3.03) 83.3 (0.25) 1,635 (64.37) (3.28) (1.75) 1,668.2 (65.68) H I J K L M N O P Q R S T Dimensional drawing (Dimensions in mm (inch)) 1,700.2 (66.94) A B C D E F 142.1 (5.59) 4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2016-07-04 20:20:08 Subject to change without notice EXS-12D6803B020, EXE-12D6803B020 | deTec4 Core Ex SAFETY LIGHT CURTAINS Connection diagram deTec4 Core safety light curtain connected to UE48-2OS safety relay 24 V DC 1 +24V +24V 1 2 n.c. 3 OSSD1 GND 3 GND OSSD2 4 4 n.c. 5 2 n.c. n.c. 5 S1 S33 S11 S12 S31 A1 k1 k2 13 23 31 14 24 32 UE48-2OS2D2 S34 S35 S21 S22 A2 K1 K2 0 V DC E114585/01/2014-05-08 Task Connection of a deTec4 Core safety light curtain to UE48-2OS. Operating mode: with restart interlock and external device monitoring. Function When the light path is clear, the OSSD1 and OSSD2 outputs are live. The system is ready to switch on if K1 and K2 are de-energized. By pressing S1 (button is pressed and released), the UE48-2OS is energized and its 13 - 14 and 23 - 24 contacts activate K1 and K2. On interruption of one of the light beams, the UE48-2OS is de-energized by the OSSD1 and OSSD2 outputs and K1 and K2 are deactivated. Fault analysis OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The incorrect functioning of one of the K1 or K2 contactors will be detected and does not result in the loss of the shutdown function. Jamming of the S1 button will prevent the UE48-2OS from enabling. Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, the integration must be dual-channel (x/y paths). Single-channel integration in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. Recommended accessories Other models and accessories www.sick.com/deTec4_Core_Ex Brief description Type Part no. Terminal and alignment brackets 2016-07-04 20:20:08 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5 EXS-12D6803B020, EXE-12D6803B020 | deTec4 Core Ex SAFETY LIGHT CURTAINS A B C D E F Brief description 2 pieces, alignment bracket for explosion-proof enclosure Part no. BEF-1SHABRST2 2072525 Cable gland 5329001 AR60 1015741 AR60 adapter, Ex 2074849 Test rod 30 mm 2022602 Plug connectors and cables Cable gland for the European market Alignment aids Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into the beam! Adapter AR60 for explosion-proof enclosure Test and monitoring tools 30 mm diameter H I J K L M N O P Q R S T Type 6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2016-07-04 20:20:08 Subject to change without notice Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG | Waldkirch | Germany | www.sick.com