DB Lectro NVF4-6AZ100ADC12V Contact load capacity up to 150a Datasheet

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
NVF4-6
NHG RELAYS
Operation condition
NVF4-6
34.5 32.5 34
Features
Miniature.
Contact load capacity up to 150A.
Suitable for automobile.
Terminal types as inserting.
Insulation Resistance1)
Dielectric Strength1)
Between contacts
Between contact and coil
50Hz 750V
50Hz 1000V
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
147m/s2
11ms
10~40Hz double amplitude 1.5mm
30N
235
2
3 0.5s
-40~125
85% (at 40 )
65g
100M
min (at 500VDC)
Item 7 of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3 Test Ca
Note: 1). When testing, coil terminals should be connected ,If coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
of IEC255-19-1 and minimum sample size 24.
Dimensions
mm /inch
NVF4-6 C Z 50 a DC12V N D
8
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
1A SPSTNO ,1C
AgSnO 2 , AgNi
1A
100A,150A/12VDC
Max. Switching Power
Max. Switching Voltage
1800W
Max. Switching Current:150A
75VDC
30m
Item 3.12 of IEC255-7
200mV (at Contact rating)
10 5
Item 3.30 of IEC255-7
10 7
Item 3.31 of IEC255-7
Operation
life
Electrical
Mechanical
6.3
0.248
11.5
0.453
15.5
0.610
1
0.8
0.031
9.0
0.354
0.8
0.031
50A
1C
NO: 50A/24VDC,100A/12VDC
NC: 80A,100A/12VDC
33 Max.
1.300max.
35 Max.
1.378max.
35 Max.
0.610max.
32.5max.
1.279max.
9.5
0.374
9
0.354
1.2
0.047
100A
Dimensions
0.354
Contact Resistance or Voltage drop
SPDT(B-M)
34.5max.
1.358max.
0.039
6 Coil rated voltage(V) DC:12,24
7 Contact material N:AgNi NIL: AgSnO 2
8 Coil transient suppression: D: with diode.;
2D:with two diodes.;.
R: with resistance.;
DR: with diode and resistance;
NIL: standard
4.6
7
0.181
6
34.0max.
5
1.339max.
4
0.3
3
11.5
2
Part number NVF4-6
Contact arrangement A:1A C:1C
Enclosure S: Sealed type Z: Dust cover
Contact Current 50A,100A
Terminals a: plug in type
0.453 0.012
1
1
2
3
4
5
Pickup
voltage
VDC(max)
(65%of rated
voltage )
Release
voltage
VDC(min)
(10% of rated
voltage)
Rated
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
Wiring diagram (Bottom view)
0.705
Max.
Coil
resistance
10%
Coil voltage
VDC
0.315
Dash
numbers
0.331
Coil Parameter
0.331
012-2900
12
15.6
50
7.8
1.2
024-2900
24
31.2
195
15.6
2.4
2.9
10
5
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
0.661
Mounting (Bottom view)
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Huaguan Relay Corporation LTD.