AIMTEC AMSRO1-7815-NZ Up to 15watt | dc-dc switching regulator Datasheet

Click on Series name for product info on aimtec.com
Series AMSRO1-78-NZ
Up to 15Watt | DC-DC Switching Regulator
FEATURES:
• Short Circuit Protection
• High efficiency up to 96%
• Non-Isolated
•
•
•
Operating temperature -40°C to +85°C
Very low No load input current
Pin Compatible to LM78xx
Models
Single output
Model
Input Voltage
Nom/Range
(V)
Output
Voltage
(V)
Output
Current max
(mA)
Efficiency
Vin Min
(%)
Efficiency
Vin Max
(%)
Max.
Capacitive
load (µF)
90
93
86
96
89
96
89
81
86
82
93
88
94
89
680
680
330
680
330
680
330
AMSRO1-783.3-NZ
24 / 6-36
3.3
1000
24 / 8-36
5
1000
AMSRO1-7805-NZ
12 / 8-27
-5
-300
24 / 16-36
12
1000
AMSRO1-7812-NZ
12 / 8-20
-12
-300
24 / 20-36
15
1000
AMSRO1-7815-NZ
12 / 8-18
-15
-300
NOTE: For Input voltage >30VDC, an input capacitor 22µF/50V is required.
Input Specifications
Parameters
Voltage range
Filter
Quiescent current
Conditions
Typical
Maximum
See the table above
Capacitor
Vin=(LL-HL) at 0% load
Units
VDC
1
mA
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Transient response deviation
Transient Recovery time
Ripple & Noise
Conditions
Typical
Maximum
Units
±2
±4
±3
%
100% load, 3.3V output
100% load, Others
Vin=(LL-HL) at full load
Nominal Input, 10-100% load
-40°C to +85°C ambient
Continuous
Auto recovery
±0.2
±0.4
±0.03
±0.4
±0.6
300
1
75
Nominal Input, 25% load step change
20MHz Bandwidth, 10-100% load
20
%
%
%/oC
mV
mSec
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Weight
Dimensions (L x W x H)
MTBF
Soldering Temperature
Conditions
100% load
With derating above 71oC
Typical
Maximum
Units
100
KHz
o
C
oC
oC
420-780
-40 to +85
-55 to +125
Free air convection
Non condensing
95
2.1
0.45 x 0.30 x 0.69 inches 11.50 x 7.50 x 17.50 mm
>2 000 000 hrs (MIL-HDBK-217F, Ground Benign, t=+25oC)
1.5 mm from case for 10 sec
260
%
g
oC
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R6.J
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMSRO1-78-NZ
Up to 15Watt | DC-DC Switching Regulator
Safety Specifications
Parameters
Approval
UL
IEC/EN/UL60950-1
EN55022, Class B (with recommended circuit)
IEC61000-4-2 (ESD): Contact ±4KV, Perf. Criteria B
IEC61000-4-3 (Radiation Immunity): 10V/m, Perf. Criteria A
IEC61000-4-4 (EFT): ±1KV, Perf. Criteria B (with recommended circuit)
IEC61000-4-5 (Surge): line to line ±1KV, Perf: Criteria B
IEC61000-4-6 (CDI): 3Vrms, Perf: Criteria A
Standards
Dimensions
Pin Out Specifications
7.50
(0.30)
11.50
(0.45)
Right
view
Pin
Positive
Negative
1
2
3
+V Input
Ground
+V Output
+V Input
-V Output
Ground
17.50
(0.69)
Front
view
1 2 3
Ø1.20
(Ø0.05)
2
1
DIV: 2.54 (0.1)
4.10
(0.16)
3
0.64
(0.03)
2.54
(0.10)
0.64
(0.03)
5.40
(0.21)
Dimensions are typical values: mm (inch)
General Tolerance: ± 0.50 (± 0.02)
Pin Tolerance: ± 0.10 (± 0.004)
Derating
Free Air Convection
71º C
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
NOTE: With air convection speed of 0.8m/sec
www.aimtec.com
F 051e R6.J
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMSRO1-78-NZ
Up to 15Watt | DC-DC Switching Regulator
Standard Application circuit – positive output
3
1
+Vin
+Vout
AMSRO1-78-NZ
+
+
C1
10uF
C2
22uF
2
GND
GND
Standard Application circuit – negative output
2
1
+Vin
-Vout
AMSRO1-78-NZ
C2
22uF
+
C1
10uF
+
3
GND
GND
Recommended EMC circuit
1
Vin
Fuse
LDM
82µH
Customer
Selectable
MOV
S20K30
GND
+
C0
680µF
50V
AMSRO- 78XX - NZ
3
Vout
LDM
12µH
C1
4.7µF
50V
C2
10µF
50V
2
C3
22µF
25V
GND
NOTE: This part is not designed for parallel operation
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R6.J
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only