XP Power AEJ50US19 Ac-dc power supply Datasheet

AEJ50 Series
AC-DC Power Supplies
50 Watts
• Energy Efficiency Level VI
• European CoC Tier 2
• <0.15 W Standby Power
• Single Output 12 to 48 V
• 0 °C to 65 °C Operation
• Universal Input
• 3 Year Warranty
Dimensions:
AEJ50:
4.72 x 2.05 x 1.22” (120.0 x 52.0 x 31.0 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
12.0 V
15.0 V
19.0 V
24.0 V
28.0 V
36.0 V
48.0 V
50 W
Total Regulation
Efficiency(1)
±5%
89%
89%
89%
89%
89%
89%
89%
4.20 A
3.36 A
2.65 A
2.10 A
1.80 A
1.40 A
1.05 A
Model Number
AEJ50US12
AEJ50US15
AEJ50US19
AEJ50US24
AEJ50US28
AEJ50US36
AEJ50US48
Notes
1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input.
Mechanical Details
Cable length
12-19 V:
48” (1220 mm) 16 AWG
24-48 V:
48” (1220 mm) 18 AWG
2.09
(53.0)
4.72
(120.0)
0.47
(12.00)
IEC320-C14
1.24
(31.5)
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.60 lbs (300 g) approx.
3. Tolerance is ±0.02 (±0.5) maximum, except output cable length
which is ±2” (±50 mm)
1
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
www.xppower.com
AEJ50 Series
AC-DC Power Supplies
Input
Characteristic
Minimum
Notes & Conditions
Maximum
Units
264
VAC
63
50
350
0.15
Hz
A
A
µA
W
Max.
48
±2
Units
VDC
%
3
20
Full load and 115 VAC
±1
±4
s
ms
ms
%
%
Transient Response
5
%
Maximum deviation, recovering to less than 1% within
500 µs for 25% step load
Ripple and Noise
1
% pk-pk
10
175
125
%
%
%
Input Voltage
90
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
No Load Input Power
Input Protection
47
Typical
1.20
Measured at 100VAC
230 VAC, cold start at 25 °C
264 VAC, 60 Hz
T2.0A/250 VAC internal fuse in line
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Total Regulation
Min.
12
Typ.
8
Overshoot
Overload Protection
Overvoltage Protection
Short Circuit Protection
Temperature Coefficient
115
112
Trip and restart (hiccup), auto resetting
0.05
Notes & Conditions
See Models and Ratings table
At 60% load
No minimum load required
Measured with 20 MHz Bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor.
At turn on / turn off
Recycle mains to reset
%/°C
Environmental
Characteristic
Operating Temperature
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Vibration
Minimum
-20
Natural convection
5
-40
Typical
Maximum
+65
Units
°C
90
%RH
+85
°C
5000
m
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes
Notes & Conditions
Derate from 100% load at 50 °C to 58% load at 65 °C
Non-condensing
Derating Curve
Output Power (%)
100
80
60
40
20
-20
50
Ambient Temperature (ºC)
www.xppower.com
65
2
AEJ50 Series
AC-DC Power Supplies
General
Characteristic
Minimum
Typical
Efficiency
Maximum
Isolation: Input to Output
Input to Ground
Output to Ground
Notes & Conditions
Units
%
89
3000
VAC
1500
VAC
See Models and Ratings table and curves.
Negative output is connected to ground
Switching Frequency
kHz
65
Power Density
W/in3
4.23
Mean Time Between Failure
285
kHrs
Weight
0.60 (300)
MIL-HDBK-217F at 25 °C GB for 24 V version
lb (g)
Efficiency Curves
AEJ50US12
100%
Efficiency
90%
80%
115Vac input
70%
230Vac input
60%
50%
10
20
30
40
50
60
70
80
90
100
Load (%)
AEJ50US24
100%
Efficiency
90%
80%
115Vac input
70%
230Vac input
60%
50%
10
20
30
40
50
60
70
80
90
100
Load (%)
EMC: Emissions
Phenomenon
Emissions
Harmonic Current
Voltage Flicker
Standard
EN55022
EN61000-3-2
EN61000-3-3
Test Level
Level B
Class A
www.xppower.com
Notes & Conditions
Conducted & Radiated
3
AEJ50 Series
AC-DC Power Supplies
EMC: Immunity
Phenomenon
Standard
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
Dips and Interruptions
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level
Criteria
±8 kV Air, ±6 kV contact
3 V/m
2
Installation Class 3
3V
3 A/m
Dip: 30% 500 ms
Dip: 60% 100 ms
Int: 100% 5000 ms
Int: 100% 10 ms
A
A
A
A
A
A
A/B
A/B
B
A
Notes & Conditions
High Line/Low Line
High Line/Low Line
Safety Approvals
Safety Agency
UL
Safety Standard
Notes & Conditions
UL60950-1
TUV
EN60950-1
CB
IEC60950-1
Mechanical Details
Cable length
12-19 V:
48” (1220 mm) 16 AWG
24-48 V:
48” (1220 mm) 18 AWG
2.09
(53.0)
4.72
(120.0)
0.47
(12.00)
IEC320-C14
1.24
(31.5)
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.60 lbs (300 g) approx.
3. Tolerance is ±0.02 (±0.5) maximum, except output cable length
which is ±2” (±50 mm)
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
www.xppower.com