Enclosed Switch D4MC CSM_D4MC_DS_E_2_1 Economical, High Utility Enclosed Switch • Enclosed Switches with Built-in Basic Switches for High Repeatability and Durability of 10 Million Operations Minimum. • Panel mount versions have the same operating position as Z Basic Switch. • Suitable for applications demanding higher mechanical strength, dustproof and drip-proof properties than those on basic switches. • Resin molded terminal versions are available. • Approved by UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.) Be sure to read Safety Precautions on page 5 and Safety Precautions for All Limit Switches. Model Number Structure Ordering Information Model Number Legend Actuator D4MC(1) (1) Actuator 5000: Panel mount plunger 5020: Panel mount roller plunger 5040: Panel mount crossroller plunger 1000: Hinge lever 1020: Short hinge lever 2000: Hinge roller lever 2020: Short hinge roller lever 3030: One-way action short hinge roller lever Model Panel mount plunger D4MC-5000 Panel mount roller plunger D4MC-5020 Panel mount crossroller plunger D4MC-5040 Hinge lever D4MC-1000 Short hinge lever D4MC-1020 Hinge roller lever D4MC-2000 Short hinge roller lever D4MC-2020 One-way action short hinge roller lever D4MC-3030 Note: 1. Use Switches with molded terminals in locations subject to dirt, dust, oil drops, or high humidity. Models are available with lead wires on the right, on the left, and from the bottom. 2. Contact your OMRON representative for information on models certified for international standards. Specifications Approved Standards Agency UL * CCC(CQC) Standard UL508, CSA C22.2 No.14 GB14048.5 File No. E76675 2003010303077627 Note: Ask your OMRON representative for information on approved models. * UL certified for CSA C22.2 No. 14. 1 D4MC Ratings Rated voltage 125 VAC 250 VAC 480 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC Inrush current Approved Standard Ratings Non-inductive load (A) Resistive load Lamp load NC NO NC NO 10 3 1.5 10 2.5 1.25 3 1.5 0.75 10 3 1.5 10 3 1.5 6 3 1.5 0.5 0.4 0.4 0.25 0.2 0.2 NC NO UL/CSA A300 Inductive load (A) Inductive load Motor load NC NO NC NO 10 5 2.5 10 3 1.5 2.5 1.5 0.75 6 5 2.5 6 5 2.5 5 5 2.5 0.05 0.05 0.05 0.03 0.03 0.03 120 VAC 3 Break 7,200 720 Engineering Data Electrical Durability 10,000,000 operations min. Electrical 500,000 operations min. Durability (x 104 operations) Mechanical 0.05 mm/s to 0.5 m/s *1 Mechanical 120 operations/min Electrical 20 operations/min 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 15 mΩ max. (initial value for the built-in switch when tested alone) Between terminals of the same polarity 1,000 VAC, 50/60 Hz for 1 min Between each terminal and non-current-carrying part 2,000 VAC, 50/60 Hz for 1 min 125 VAC cosφ=0.4 250 VAC cosφ=1 1,000 700 500 250 VAC cosφ=0.4 100 70 50 Operating temperature: +20±2°C Operating humidity: 65±5%RH Operating frequency: 20 operations/min 10 0 Pollution degree (operating environment) 3 (IEC947-5-1) Protection against electric shock Class II PTI (tracking characteristics) 175 Switch category D (IEC335) Rated operating current (Ie) 10 A Rated operating voltage (Ue) 250 VAC Vibration Malfunction resistance 10 to 55 Hz, 1.5-mm double amplitude *2 1,000 125 VAC cosφ=1 3,000 30 1,000 VAC m/s2 10,000 7,000 5,000 300 Rated insulation voltage (Ui) Destruction Shock resistance Malfunction 30 Make AC-12 10 A/250 VAC IP67 Rated frequency Dielectric strength 6 Applicable category and ratings 2 4 6 8 10 12 Switching Current (A) Mechanical Durability (D4MC-5000) Durability (x 104 operations) Operating frequency 60 Volt-amperes (VA) CCC (GB14048.5) Characteristics Operating speed Break EN60947-5-1 Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp load has an inrush current of 10 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. 5. The above ratings were tested under the following conditions. (1) Ambient temperature: +20±2°C (2) Ambient humidity: 65±5%RH (3) Operating frequency: 20 operations/min Durability Make 10A 240 VAC 30 A max. 15 A max. Degree of protection Current (A) Carry current Rated voltage min. 10,000 Operating temperature: +20±2°C Operating humidity: 65±5%RH No load Operating frequency: 120 operations/min 5,000 2,000 1,000 500 100 m/s2 min. *1 *2 Ambient operating temperature −10°C to +80°C (with no icing) Ambient operating humidity 35% to 95%RH Weight Approx. 71 g (in case of panel mount plunger) 200 100 0.01 0.02 *1. Only for models with plungers. (Contact your OMRON representative for information on other models.) *2. Less than 1 ms under a free state at the operating limits. 0.05 0.1 0.2 0.5 1 2 5 10 OT (mm) Structure and Nomenclature Structure Contact Form Roller Changing the Terminal Protective Cover around allows the cable to be pulled out from either the right or the left. (COM) 1 2 (NC) 4 (NO) Case M4 binding head screws (with toothed washers) are used as the terminal screws. Pushbutton Built-in switch Seal rubber Terminal Protective Cover Common terminal (COM) Normally closed Normally open terminal (NC) terminal (NO) 2 D4MC Dimensions and Operating Characteristics Panel Mount Plunger D4MC-5000 A PT *1 M12 × 1 mounting screw Two hexagon nuts *3 53.4 23.3 (Unit: mm) Panel Mount Roller Plunger D4MC-5020 53.4 A PT 12.7 dia. x 5 *1 23.3 M12 x 1 mounting screw Two hexagon nuts *3 8.4 dia. OP OP 15.8 *2 15.5 *2 14 16 dia. 16 dia. 25 25 23 7 23 7 (10) 22 max.18.3 14 (10) 22 max.18.3 25.4±0.15 *1. Stainless steel plunger *2. The length of the imperfect threads is 1.5 mm maximum. *3. Thickness: 3 width: 17 (21 × 21) 21.7 15 55 Terminal protective cover Two, 4.3±0.1 dia. mounting holes Note: Do not use the M12 mounting screw and the case mounting hole at the same time. Panel Mount Crossroller Plunger D4MC-5040 53.4 A PT 23.3 25.4±0.15 Seal rubber (NBR) 15 55 Terminal protective cover *1. Stainless steel plunger *2. The length of the imperfect threads is 1.5 mm maximum. *3. Thickness: 3 width: 17 (21 x 21) 21.7 Two, 4.3±0.1 dia. mounting holes Seal rubber (NBR) Note: Do not use the M12 mounting screw and the case mounting hole at the same time. Hinge Lever D4MC-1000 14 12.7 dia. × 5 *1 M12 × 1 mounting screw Two hexagon nuts *3 53.4 34.7 t=1 * A 14 72.7R OP 6.4 *2 15.5 16 dia. FP 26.5 22.5 25 19.5 23 7 7 (10) 22 max.18.3 (10) 22 max.18.3 25.4±0.15 25.4±0.15 Terminal protective cover *1. Stainless steel plunger *2. The length of the imperfect threads is 1.5 mm maximum. *3. Thickness: 3 width: 17 (21 × 21) 21.7 15 55 Two, 4.3±0.1 dia. mounting holes Seal rubber (NBR) (21 × 21) 21.7 15 55 Terminal protective cover Two, 4.3±0.1 dia. mounting holes * Stainless steel lever Seal rubber (NBR) Note: Do not use the M12 mounting screw and the case mounting hole at the same time. Short Hinge Lever D4MC-1020 t=1 * OP Hinge Roller Lever D4MC-2000 53.4 34.7 48.6R 53.4 34.7 A 14 A 12.7 dia. × 7.5 *2 14 t=1 *1 6.4 63.7R FP 26.5 22.5 19.5 7 OP FP 26.5 22.5 (10) 22 max.18.3 19.5 7 (10) 22 max.18.3 25.4±0.15 Terminal protective cover OP 55 * Stainless steel lever 15 Two, 4.3±0.1 dia. mounting holes (21 × 21) 21.7 25.4±0.15 Seal rubber (NBR) Terminal protective cover 55 *1. Stainless steel lever *2. Plastic roller 15 Two, 4.3±0.1 dia. mounting holes (21 × 21) 21.7 Seal rubber (NBR) Note: 1. Unless otherwise specified, a tolerance of±0.4 mm applies to all dimensions. 2. Operating characteristics are for when the Switch is operated from direction A. 3. Make sure that the permissible OT position is not exceeded. Operating Characteristics Operating force OF Release force RF Pretravel PT Overtravel OT Movement Differential MD Free Position FP Operating Position OP Model max. min. max. min. max. max. D4MC-5000 5.88 N 0.98 N 1.6 mm 5 mm 0.2 mm --21.8±1.2 mm D4MC-5020 5.88 N 0.98 N 1.6 mm 5 mm 0.2 mm --33.4±1.2 mm D4MC-5040 5.88 N 0.98 N 1.6 mm 5 mm 0.2 mm --33.4±1.2 mm D4MC-1000 1.67 N 0.25 N --4 mm 3 mm 36 mm 25±1 mm D4MC-1020 2.55 N 0.34 N --2.5 mm 1.7 mm 33 mm 25±1mm D4MC-2000 1.96 N 0.39 N --5 mm 3 mm 51 mm 40±1 mm 3 D4MC Short Hinge Roller Lever D4MC-2020 One-way Action Short Hinge Roller Lever D4MC-3030 53.4 34.7 14 A 12.7 dia. × 7.5 *2 t=1 *1 t=1 *1 53.4 34.7 Angle of roller swing: 90° 41R A 14 12.7 dia. × 7.5 *2 46.6R FP OP 26.5 22.5 OP FP 19.5 26.5 7 22.5 19.5 (10) 22 max.18.3 7 (10) 22 max.18.3 25.4±0.15 (21 × 21) 15 55 Terminal protective cover Two, 4.3±0.1 dia. mounting holes *1. Stainless steel lever *2. Plastic roller 21.7 25.4±0.15 Seal rubber (NBR) 55 Terminal protective cover *1. Stainless steel lever *2. Plastic roller (21 × 21) 15 Two, 4.3±0.1 dia. mounting holes 21.7 Seal rubber (NBR) Note: 1. Unless otherwise specified, a tolerance of±0.4 mm applies to all dimensions. 2. Operating characteristics are for when the Switch is operated from direction A. 3. Make sure that the permissible OT position is not exceeded. Operating characteristics Model D4MC-2020 D4MC-3030 2.94 N 0.39 N --2 mm 1.5 mm 2.94 N 0.39 N --2 mm 1.5 mm 47 mm 40±1 mm 57.2 mm 50±1 mm OF max. Operating force RF mim. Release force PT max. Pretravel Overtravel OT min. Movement Differential MD max. Free Position Operating position FP max. OP Molded Terminal Models (Not Approved by UL, CSA, or EN) Use Switches with molded terminals in locations subject to dirt, dust, oil drops, or high humidity. Molded terminals are available with all D4MC models. Dimensions and operating characteristics are the same as the basic models. Suffix by Location of Lead Outlet Model Location of lead outlet (Refer to left figure) COM, NC, and NO (1) Right-hand (2) Left-hand (3) Underside D4MC-@@@1 D4MC-@@@2 D4MC-@@@3 Note: To form the model numbers for molded terminals models, add the numbers 1 to 3 in the table above to the end of the model number in Ordering Information on page 1. Leads Supplied Specifications (1) (2) Leads (3) V.C.T. (Vinyl cabtire cable) Nominal cross-sectional area mm2 1.25 External diameter mm Terminal Cable length connections m Black: COM 3 conductor White: NO 10.5 dia. Red: NC 1, 3 Note: Add the VCT length to the end of the model number when ordering. Consult with your OMRON representative for other types of lead wires and for lead wires longer than 3 m. How to Order Example: Standard type: D4MC-5020 Location of lead outlet: Underside Length of lead: 1 m (V.C.T. lead) When placing your order for the above Switch specify the model number as D4MC-5023 VCT 1M Terminal Protective Cover, Seal Rubber, and Rubber Packing (The Switch is equipped with these 3 items as a standard.) Rubber packing Terminal cover Seal rubber • ZC Terminal Cover (Product code: ZC55-0002H) • ZC Seal Rubber (Product code: SC-1404C) • ZC Rubber Packing (Product code: ZC55-0003F) 4 D4MC Safety Precautions Refer to Safety Precautions for All Limit Switches. Precautions for Use Operating Environment • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. Not Suitable • When mounting the Terminal Protective Cover to the case, align the cover on the case and then press the cover down to mount it firmly. If the cover is pressed down in an inclined position, rubber packing will deform and thus affect the sealing capability. Suitable Rubber packing Rubber packing Mounting • Constantly subjecting a Switch to vibration or shock can result in wear, which can lead to contact interference with contacts, operation failure, reduced durability, and other problems. Excessive vibration or shock can lead to false contact operation or damage. Install Switches in locations not subject to shock and vibration and in orientations that will not produce resonance. • The Switches have physical contacts. Using them in environments containing silicon gas will result in the formation of silicon oxide (SiO2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the Switch, suppress arcing with contact protective circuits (surge killers) or remove the source of silicon gas. Operating Excessive dog angle, operating speed, or overtravel (OT) may damage the actuator. Check that OT has a sufficient margin. The actual OT should be rated OT × 0.7 to 1. • When mounting the Switch with screws on a side surface, fasten the Switch with M4 screws and use washers, spring washers, etc., to ensure secure mounting. Mounting Holes Two, 4.3-dia. or M4 screw holes 25.4±0.15 • When mounting the Panel Mount-type Switch (D4MC-5000, D4MC5020, or D4MC-5040) with screws on a side surface, remove the hexagonal nuts from the actuator. • When mounting the panel mount type on a panel, be careful not to tighten to an excessive torque. Tightening the screws to a torque exceeding 4.91 N·m will cause the plunger to fail. Mounting Hole Dimensions D4MC-5000 D4MC-5020, D4MC-5040 12.5+0.2 0 dia. 12.5+0.2 0 dia. Handling • Do not expose the Switch to water exceeding +60°C or use it in steam. • Do not use the Switch in oil or water. • An 8.5-dia. to 10.5-dia. cable can be applied as seal rubber for the lead wire outlet. (Use two- or three-core cable of VCT1.25 mm2.) • When detaching the Terminal Protective Cover, insert a screwdriver and apply a force in the opening direction. Do not use excess force to remove the cover. Doing so may cause deformation in the fitting section and reduce the holding force. 5+0.2 0 13+0.2 0 Tightening Torque A loose screw may cause malfunctions. Be sure to tighten each screw to the proper tightening torque as shown in the table. Appropriate tightening No. Type torque (1) Terminal screw 0.78 to 1.18 N·m 2.94 to 4.92 N·m (2) Panel mounting screw 1.18 to 1.47 N·m (3) Side mounting screw 5 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS • Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • [email protected] OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu CSM_D4MC_DS_E_2_1 11/08 Note: Specifications are subject to change. © 2010 Omron Electronics LLC