Omron D4MC-2020 Economical, high utility enclosed switch Datasheet

Enclosed Switch
D4MC
CSM_D4MC_DS_E_2_1
Economical, High Utility Enclosed Switch
• Enclosed Switches with Built-in Basic Switches for High
Repeatability and Durability of 10 Million Operations Minimum.
• Panel mount versions have the same operating position as
Z Basic Switch.
• Suitable for applications demanding higher mechanical
strength, dustproof and drip-proof properties than those
on basic switches.
• Resin molded terminal versions are available.
• Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Be sure to read Safety Precautions on page 5 and Safety Precautions for All
Limit Switches.
Model Number Structure
Ordering Information
Model Number Legend
Actuator
D4MC(1)
(1) Actuator
5000: Panel mount plunger
5020: Panel mount roller plunger
5040: Panel mount crossroller plunger
1000: Hinge lever
1020: Short hinge lever
2000: Hinge roller lever
2020: Short hinge roller lever
3030: One-way action short hinge roller lever
Model
Panel mount plunger
D4MC-5000
Panel mount roller
plunger
D4MC-5020
Panel mount
crossroller plunger
D4MC-5040
Hinge lever
D4MC-1000
Short hinge lever
D4MC-1020
Hinge roller lever
D4MC-2000
Short hinge roller
lever
D4MC-2020
One-way action short
hinge roller lever
D4MC-3030
Note: 1. Use Switches with molded terminals in locations subject to dirt, dust, oil
drops, or high humidity. Models are available with lead wires on the
right, on the left, and from the bottom.
2. Contact your OMRON representative for information on models
certified for international standards.
Specifications
Approved Standards
Agency
UL *
CCC(CQC)
Standard
UL508, CSA C22.2 No.14
GB14048.5
File No.
E76675
2003010303077627
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
1
D4MC
Ratings
Rated
voltage
125 VAC
250 VAC
480 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Inrush
current
Approved Standard Ratings
Non-inductive load (A)
Resistive load
Lamp load
NC
NO
NC
NO
10
3
1.5
10
2.5
1.25
3
1.5
0.75
10
3
1.5
10
3
1.5
6
3
1.5
0.5
0.4
0.4
0.25
0.2
0.2
NC
NO
UL/CSA
A300
Inductive load (A)
Inductive load
Motor load
NC
NO
NC
NO
10
5
2.5
10
3
1.5
2.5
1.5
0.75
6
5
2.5
6
5
2.5
5
5
2.5
0.05
0.05
0.05
0.03
0.03
0.03
120 VAC
3
Break
7,200
720
Engineering Data
Electrical Durability
10,000,000 operations min.
Electrical
500,000 operations min.
Durability (x 104 operations)
Mechanical
0.05 mm/s to 0.5 m/s *1
Mechanical
120 operations/min
Electrical
20 operations/min
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max. (initial value for the built-in
switch when tested alone)
Between terminals of the
same polarity
1,000 VAC, 50/60 Hz for 1 min
Between each terminal and
non-current-carrying part
2,000 VAC, 50/60 Hz for 1 min
125 VAC cosφ=0.4
250 VAC cosφ=1
1,000
700
500
250 VAC cosφ=0.4
100
70
50
Operating temperature: +20±2°C
Operating humidity: 65±5%RH
Operating frequency: 20 operations/min
10
0
Pollution degree
(operating environment)
3 (IEC947-5-1)
Protection against electric shock
Class II
PTI (tracking characteristics)
175
Switch category
D (IEC335)
Rated operating current (Ie)
10 A
Rated operating voltage (Ue)
250 VAC
Vibration
Malfunction
resistance
10 to 55 Hz, 1.5-mm double amplitude *2
1,000
125 VAC cosφ=1
3,000
30
1,000 VAC
m/s2
10,000
7,000
5,000
300
Rated insulation voltage (Ui)
Destruction
Shock
resistance Malfunction
30
Make
AC-12 10 A/250 VAC
IP67
Rated frequency
Dielectric
strength
6
Applicable category and ratings
2
4
6
8
10
12
Switching Current (A)
Mechanical Durability (D4MC-5000)
Durability (x 104 operations)
Operating
frequency
60
Volt-amperes (VA)
CCC (GB14048.5)
Characteristics
Operating speed
Break
EN60947-5-1
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions.
(1) Ambient temperature: +20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
Durability
Make
10A
240 VAC
30 A max.
15 A max.
Degree of protection
Current (A)
Carry
current
Rated voltage
min.
10,000
Operating temperature: +20±2°C
Operating humidity: 65±5%RH
No load
Operating frequency: 120 operations/min
5,000
2,000
1,000
500
100 m/s2 min. *1 *2
Ambient operating temperature
−10°C to +80°C (with no icing)
Ambient operating humidity
35% to 95%RH
Weight
Approx. 71 g (in case of panel mount plunger)
200
100
0.01 0.02
*1. Only for models with plungers. (Contact your OMRON representative for
information on other models.)
*2. Less than 1 ms under a free state at the operating limits.
0.05 0.1
0.2
0.5
1
2
5
10
OT (mm)
Structure and Nomenclature
Structure
Contact Form
Roller
Changing the Terminal Protective Cover
around allows the cable to be pulled out
from either the right or the left.
(COM) 1
2 (NC)
4 (NO)
Case
M4 binding head screws (with toothed
washers) are used as the terminal screws.
Pushbutton
Built-in switch
Seal rubber
Terminal
Protective
Cover
Common
terminal (COM)
Normally closed
Normally open terminal (NC)
terminal (NO)
2
D4MC
Dimensions and Operating Characteristics
Panel Mount Plunger
D4MC-5000
A
PT
*1
M12 × 1 mounting screw
Two hexagon nuts
*3
53.4
23.3
(Unit: mm)
Panel Mount Roller Plunger
D4MC-5020
53.4
A
PT
12.7 dia. x 5 *1
23.3
M12 x 1 mounting screw
Two hexagon nuts
*3
8.4 dia.
OP
OP
15.8
*2
15.5 *2
14
16 dia.
16 dia.
25
25
23
7
23
7
(10)
22 max.18.3
14
(10)
22 max.18.3
25.4±0.15
*1. Stainless steel plunger
*2. The length of the imperfect
threads is 1.5 mm maximum.
*3. Thickness: 3 width: 17
(21 × 21)
21.7
15
55
Terminal protective cover
Two, 4.3±0.1 dia.
mounting holes
Note: Do not use the M12 mounting screw and
the case mounting hole at the same time.
Panel Mount Crossroller Plunger
D4MC-5040
53.4
A
PT
23.3
25.4±0.15
Seal rubber
(NBR)
15
55
Terminal protective cover
*1. Stainless steel plunger
*2. The length of the imperfect
threads is 1.5 mm maximum.
*3. Thickness: 3 width: 17
(21 x 21)
21.7
Two, 4.3±0.1 dia.
mounting holes
Seal rubber
(NBR)
Note: Do not use the M12 mounting screw and
the case mounting hole at the same time.
Hinge Lever
D4MC-1000
14
12.7 dia. × 5 *1
M12 × 1 mounting screw
Two hexagon nuts
*3
53.4
34.7
t=1 *
A
14
72.7R
OP
6.4
*2
15.5
16 dia.
FP
26.5 22.5
25
19.5
23
7
7
(10)
22 max.18.3
(10)
22 max.18.3
25.4±0.15
25.4±0.15
Terminal protective cover
*1. Stainless steel plunger
*2. The length of the imperfect
threads is 1.5 mm maximum.
*3. Thickness: 3 width: 17
(21 × 21)
21.7
15
55
Two, 4.3±0.1 dia.
mounting holes
Seal rubber
(NBR)
(21 × 21)
21.7
15
55
Terminal protective cover
Two, 4.3±0.1 dia.
mounting holes
* Stainless steel lever
Seal rubber
(NBR)
Note: Do not use the M12 mounting screw and
the case mounting hole at the same time.
Short Hinge Lever
D4MC-1020
t=1 *
OP
Hinge Roller Lever
D4MC-2000
53.4
34.7
48.6R
53.4
34.7
A
14
A
12.7 dia. × 7.5 *2
14
t=1 *1
6.4
63.7R
FP
26.5 22.5
19.5
7
OP
FP
26.5 22.5
(10)
22 max.18.3
19.5
7
(10)
22 max.18.3
25.4±0.15
Terminal protective cover
OP
55
* Stainless steel lever
15
Two, 4.3±0.1 dia.
mounting holes
(21 × 21)
21.7
25.4±0.15
Seal rubber
(NBR)
Terminal protective cover
55
*1. Stainless steel lever
*2. Plastic roller
15
Two, 4.3±0.1 dia.
mounting holes
(21 × 21)
21.7
Seal rubber
(NBR)
Note: 1. Unless otherwise specified, a tolerance of±0.4 mm applies to all dimensions.
2. Operating characteristics are for when the Switch is operated from direction A.
3. Make sure that the permissible OT position is not exceeded.
Operating Characteristics
Operating force
OF
Release force
RF
Pretravel
PT
Overtravel
OT
Movement Differential MD
Free Position
FP
Operating Position
OP
Model
max.
min.
max.
min.
max.
max.
D4MC-5000
5.88 N
0.98 N
1.6 mm
5 mm
0.2 mm
--21.8±1.2 mm
D4MC-5020
5.88 N
0.98 N
1.6 mm
5 mm
0.2 mm
--33.4±1.2 mm
D4MC-5040
5.88 N
0.98 N
1.6 mm
5 mm
0.2 mm
--33.4±1.2 mm
D4MC-1000
1.67 N
0.25 N
--4 mm
3 mm
36 mm
25±1 mm
D4MC-1020
2.55 N
0.34 N
--2.5 mm
1.7 mm
33 mm
25±1mm
D4MC-2000
1.96 N
0.39 N
--5 mm
3 mm
51 mm
40±1 mm
3
D4MC
Short Hinge Roller Lever
D4MC-2020
One-way Action Short Hinge Roller Lever
D4MC-3030
53.4
34.7
14
A
12.7 dia. × 7.5 *2
t=1 *1
t=1 *1
53.4
34.7
Angle of roller
swing: 90°
41R
A
14
12.7 dia. × 7.5 *2
46.6R
FP
OP
26.5 22.5
OP
FP
19.5
26.5
7
22.5
19.5
(10)
22 max.18.3
7
(10)
22 max.18.3
25.4±0.15
(21 × 21)
15
55
Terminal protective cover
Two, 4.3±0.1 dia.
mounting holes
*1. Stainless steel lever
*2. Plastic roller
21.7
25.4±0.15
Seal rubber
(NBR)
55
Terminal protective cover
*1. Stainless steel lever
*2. Plastic roller
(21 × 21)
15
Two, 4.3±0.1 dia.
mounting holes
21.7
Seal rubber
(NBR)
Note: 1. Unless otherwise specified, a tolerance of±0.4 mm applies to all dimensions.
2. Operating characteristics are for when the Switch is operated from direction A.
3. Make sure that the permissible OT position is not exceeded.
Operating
characteristics
Model
D4MC-2020
D4MC-3030
2.94 N
0.39 N
--2 mm
1.5 mm
2.94 N
0.39 N
--2 mm
1.5 mm
47 mm
40±1 mm
57.2 mm
50±1 mm
OF max.
Operating force
RF mim.
Release force
PT max.
Pretravel
Overtravel
OT min.
Movement Differential MD max.
Free Position
Operating position
FP max.
OP
Molded Terminal Models (Not Approved by UL, CSA, or EN)
Use Switches with molded terminals in locations subject to dirt, dust, oil drops,
or high humidity. Molded terminals are available with all D4MC models.
Dimensions and operating characteristics are the same as the basic models.
Suffix by Location of Lead Outlet
Model
Location of lead outlet
(Refer to left figure)
COM, NC, and NO
(1) Right-hand
(2) Left-hand
(3) Underside
D4MC-@@@1
D4MC-@@@2
D4MC-@@@3
Note: To form the model numbers for molded terminals models, add the
numbers 1 to 3 in the table above to the end of the model number in
Ordering Information on page 1.
Leads Supplied
Specifications
(1)
(2)
Leads
(3)
V.C.T.
(Vinyl cabtire cable)
Nominal
cross-sectional area
mm2
1.25
External
diameter
mm
Terminal
Cable length
connections
m
Black: COM
3 conductor
White: NO
10.5 dia.
Red: NC
1, 3
Note: Add the VCT length to the end of the model number when ordering.
Consult with your OMRON representative for other types of lead wires
and for lead wires longer than 3 m.
How to Order
Example:
Standard type: D4MC-5020
Location of lead outlet: Underside
Length of lead: 1 m (V.C.T. lead)
When placing your order for the above Switch specify the model
number as D4MC-5023 VCT 1M
Terminal Protective Cover, Seal Rubber, and Rubber Packing (The Switch is equipped with these 3 items as a standard.)
Rubber packing
Terminal cover
Seal rubber
• ZC Terminal Cover (Product code: ZC55-0002H)
• ZC Seal Rubber (Product code: SC-1404C)
• ZC Rubber Packing (Product code: ZC55-0003F)
4
D4MC
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Precautions for Use
Operating Environment
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Not Suitable
• When mounting the Terminal Protective Cover to the case, align the
cover on the case and then press the cover down to mount it firmly.
If the cover is pressed down in an inclined position, rubber packing
will deform and thus affect the sealing capability.
Suitable
Rubber packing
Rubber packing
Mounting
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Operating
Excessive dog angle, operating speed, or overtravel (OT) may
damage the actuator. Check that OT has a sufficient margin. The
actual OT should be rated OT × 0.7 to 1.
• When mounting the Switch with screws on a side surface, fasten
the Switch with M4 screws and use washers, spring washers, etc.,
to ensure secure mounting.
Mounting Holes
Two, 4.3-dia.
or M4 screw holes
25.4±0.15
• When mounting the Panel Mount-type Switch (D4MC-5000, D4MC5020, or D4MC-5040) with screws on a side surface, remove the
hexagonal nuts from the actuator.
• When mounting the panel mount type on a panel, be careful not to
tighten to an excessive torque. Tightening the screws to a torque
exceeding 4.91 N·m will cause the plunger to fail.
Mounting Hole Dimensions
D4MC-5000
D4MC-5020, D4MC-5040
12.5+0.2
0 dia.
12.5+0.2
0 dia.
Handling
• Do not expose the Switch to water exceeding +60°C or use it in
steam.
• Do not use the Switch in oil or water.
• An 8.5-dia. to 10.5-dia. cable can be applied as seal rubber for the
lead wire outlet. (Use two- or three-core cable of VCT1.25 mm2.)
• When detaching the Terminal Protective Cover, insert a
screwdriver and apply a force in the opening direction. Do not use
excess force to remove the cover. Doing so may cause deformation
in the fitting section and reduce the holding force.
5+0.2
0
13+0.2
0
Tightening Torque
A loose screw may cause malfunctions. Be sure to tighten each
screw to the proper tightening torque as shown in the table.
Appropriate tightening
No.
Type
torque
(1) Terminal screw
0.78 to 1.18 N·m
2.94 to 4.92 N·m
(2) Panel mounting screw
1.18 to 1.47 N·m
(3) Side mounting screw
5
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the importation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
14.
15.
16.
17.
18.
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for published information.
Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
2.
3.
4.
5.
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS • Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766
www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE
Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • [email protected]
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu
CSM_D4MC_DS_E_2_1
11/08
Note: Specifications are subject to change.
© 2010 Omron Electronics LLC
Similar pages