MPD MA1224S-15RU 4:1 input range, 12w single & dual output dc/dc con vert er Datasheet

MA1200RU Series
4:1 Input Range, 12W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 12W Output Power
• 4:1 Input Voltage Range
• EN 60950 Approved
• Compact DIP Case
• 1,600 VDC I/O Isolation
• Meets EN 55032 “A”
• Single & Dual Outputs
• Remote On/Off Control
• Wide Temperature Operation
• Industry Standard Pin-Out
Input
Parameter
Conditions
Input Voltage Range
Start Up Time
Input Filter
Input Reflected Ripple Current
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 2
Cross Regulation, Dual Output
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 5
Transient Response Deviation
Output Power Protection
Temperature Coefficient
Output Short Circuit Protection
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off (See Page 3)
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Environmental
Parameter
Operating Temperature Range
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
24 VDC Input
9.0
48 VDC Input 18.0
Nominal VIN & Constant Resistive Load
␲ (Pi) Filter
Typ.
24.0
48.0
20
Max.
36.0
72.0
Min.
VIN = Min to Max
Single Output
Dual Output
See Note 3
See Note 4
Typ.
±1.2
mA P - P
Max.
±0.2
±0.5
±1.0
±5.0
85
250
25% Load Step Change
±3.0
170
±0.02
Continuous (Autorecovery)
Conditions
Input/Output, 60 Seconds
Case/Input, Output, 60 Seconds
500 VDC
100 kHz/1V
Conditions
See Note On Page 3
Min.
1,600
1,600
1,000
Typ.
Max.
Ambient
Case
Min.
-40
%
%
mV P - P
µSec
%
% IOUT
%/ºC
Units
M⍀
pF
kHz
Typ.
Max.
12
1.2
Units
VDC
VDC
mA
Max.
+85
+105
+125
Units
ºC
ºC
ºC
5.0
Referenced to -Input (Pins 2, 3)
Conditions
Units
%
%
VDC
1,500
270
Min.
3.0
0.0
VDC
mS
20.0
Conditions
Units
Typ.
-40
Free Air Convection
RH, Non-condensing
95
%
See Mechanical Diagram (Page 3)
Copper With Nickel Coating (UL94V-0)
0.63 Oz (18g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
UL 60950, EN 62368, EN 60950
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
Typ.
Max.
Units
MHours
Max.
50.0
100.0
260
Units
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MA1224S-03RU
MA1224S-05RU
MA1224S-12RU
MA1224S-15RU
MA1224D-05RU
MA1224D-12RU
MA1224D-15RU
MA1248S-03RU
MA1248S-05RU
MA1248S-12RU
MA1248S-15RU
MA1248D-05RU
MA1248D-12RU
MA1248D-15RU
Voltage (VDC)
Nominal
24
24
24
24
24
24
24
48
48
48
48
48
48
48
Output
Current (mA)
Range
Full-Load No-Load
9.0 - 36.0
573
15
9.0 - 36.0
581
15
9.0 - 36.0
574
15
9.0 - 36.0
574
15
9.0 - 36.0
595
15
9.0 - 36.0
574
15
9.0 - 36.0
574
15
18.0 - 75.0
286
15
18.0 - 75.0
290
15
18.0 - 75.0
287
15
18.0 - 75.0
287
15
18.0 - 75.0
297
15
18.0 - 75.0
287
15
18.0 - 75.0
287
15
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3,500
2,400
1,000
800
±1,200
±500
±400
3,500
2,400
1,000
800
±1,200
±500
±400
Notes:
1. The specified maximum capacitive load is for each output.
2. Load regulation is specified for a load change of 0% to 100%. Load regulation for 3.3V output models is
±1.0% max for a load change of 0% to 100%.
3. When measuring cross regulation, the load on one output is varied from 25% to 100% while the other output
is held at 100%.
4. Output ripple is measured with a 1.0 µF capacitor connected from the +VOUT to the -VOUT pins for single output units
and from each output to common for dual output models. See the typical connection diagram & notes on page 3.
5. Transient recovery is measured to within a 1% error band for a load step change of 75% to 50% to 25%.
6. Operation at no-load will not damage these units. However, they may not meet all specifications.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above
for the correct rating.
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
Over
Max
Rating
Voltage Capacitive Efficiency Fuse
Slow-Blow
Protection
Load
(%, Typ)
(mA)
(VDC)
3.9
6.2
15.0
18.0
±15.0
±15.0
±18.0
3.9
6.2
15.0
18.0
±15.0
±15.0
±18.0
(µF Max)
2,000
2,000
430
300
1,250
200
120
2,000
2,000
430
300
1,250
200
120
87
89
90
90
87
90
90
87
89
90
90
87
90
90
3,500
3,500
3,500
3,500
3,500
3,500
3,500
1,800
1,800
1,800
1,800
1,800
1,800
1,800
Temperature Derating Curve
MPD offers a wide range of DC/DC converters in the
standard 24 pin DIP package. Models range from 1W to
15W and offer wide input ranges, high isolation & tight
regulation. Many are approved to EN 60950. For full information, go to our website or contact the factory.
Efficiency vs Output Load: Single 24 VIN Models
Efficiency vs Output Load: Single 48 VIN Models
Efficiency vs Output Load: Dual 24 VIN Models
Efficiency vs Output Load: Dual 48 VIN Models
Page 2
We Power Your Success - For Less
www.micropowerdirect.com
Typical Connection
To help meet conducted emissions requirements, the filter components (C2, C3 & L1) in the
diagram above should be used. The recommended values are 2.2 µF/100V for C2 & C3 and
12 µH for L1. These components should be mounted as close to the module as possible.
To meet the requirements of EN 61000-4-4 & EN 61000-4-5, an external filter capacitor
(C1 in the diagram above) is required. The recommended value for C1 is 330 µF/100V.
When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from each
output to common for dual output units. For noise sensitive applications, the use of 3.3 µF
capacitors will reduce the output ripple.
The Remote On/Off circuit is referenced to the minus input of the unit (pins 2 & 3). If the
On/Off input (pin 1) is connected to the minus input, the unit is shut off. If pin 1 is left
open, the unit operates normally.
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Standard
EN 55032
EN 55032
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Criteria/Level
Class A
Class A
B
A
A
A
A
A
Mechanical Dimensions
Pin Connections
Pin
Single
1
Remote On/Off
2
-VIN
3
-VIN
9
No Pin
11
NC
14
+VOUT
16
-VOUT
22
+VIN
23
+VIN
NC: No Connection
Dual
Remote On/Off
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
+VIN
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]